• Title/Summary/Keyword: 신호 검출

Search Result 3,064, Processing Time 0.024 seconds

PSNR Correlation between CR and DR according to Changed KvP (CR과 DR의 kVp 변화에 따른 PSNR 상관관계)

  • Kim, Jisun;Ahn, Byungju
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.417-422
    • /
    • 2014
  • In this study, the influence degree of the scattering of the line depending on the incident energy of the radiation objective was to evaluate a new method of quantitative methods of PSNR is provided.Value of MSE and PSNR of the DR and the Target is placed at the left when there was no change in CR Target, the change appeared to ttaran MSE and PSNR value in tube voltage. Both CR and DR seen that there is a variation of the MSE and PSNR depending on the tube voltage change Computon showed that the scattered radiation effects. If the CR and DR 80 The changes in the MSE and PSNR experience the symptoms suddenly occur in areas kVp was found to affect the optoelectronic Computon E, and at the same time, the scattered radiation detector Computon Computon by scattering due to the photoelectric effect. CR and DR of the imaging device in the future on the basis of the energy bands of the photoelectric effect of 60 kVp 70 kVp, 80 kVp, 90 kVp, compares the value of the PSNR and MSE 100 kVp in accordance with the change of the tube voltage of the CR and device DR proposes jigil scattering study of the degradation of the line quality is achieved.

Image Quality Evaluation in Computed Tomography Using Super-resolution Convolutional Neural Network (Super-resolution Convolutional Neural Network를 이용한 전산화단층상의 화질 평가)

  • Nam, Kibok;Cho, Jeonghyo;Lee, Seungwan;Kim, Burnyoung;Yim, Dobin;Lee, Dahye
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.211-220
    • /
    • 2020
  • High-quality computed tomography (CT) images enable precise lesion detection and accurate diagnosis. A lot of studies have been performed to improve CT image quality while reducing radiation dose. Recently, deep learning-based techniques for improving CT image quality have been developed and show superior performance compared to conventional techniques. In this study, a super-resolution convolutional neural network (SRCNN) model was used to improve the spatial resolution of CT images, and image quality according to the hyperparameters, which determine the performance of the SRCNN model, was evaluated in order to verify the effect of hyperparameters on the SRCNN model. Profile, structural similarity (SSIM), peak signal-to-noise ratio (PSNR), and full-width at half-maximum (FWHM) were measured to evaluate the performance of the SRCNN model. The results showed that the performance of the SRCNN model was improved with an increase of the numbers of epochs and training sets, and the learning rate needed to be optimized for obtaining acceptable image quality. Therefore, the SRCNN model with optimal hyperparameters is able to improve CT image quality.

MR Imaging of Slow-flow Using a Flow Phantom (유동모형을 이용한 저속유동의 자기공명영상)

  • Dae-Cheol Cheong;Kyung-Jae Jung;Young-Hwan Lee;Nak-Kwan Sung;Duck-Soo Chung;Ok-Dong Kim;Jong-Ki Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.2
    • /
    • pp.116-122
    • /
    • 2001
  • Purpose : To find sensitivity of MRI imaging methods to slow flow phantom study was performed with conventional Spin-Echo, gradient echo based Phase Contrast, fast GRASS, and heavily T2-weighted Fast Spin Echo pulse sequences. Materials and Methods : A siphon driven flow phantom was constructed with a ventriculo-peritoneal shunt catheter and a GE phantom to achieve continuous variable flow. Four different pulse sequences including Spin-Echo, Phase Contrast, GRASS and Heavily T2-weighted Fast Spin Echo were evaluated to depict slow flow in the range from 0.08 ml/min to 1.7 ml/min and to compare signal intensities between static fluid and flowing fluid. Results : In the slow flow above 0.17 ml/min conventional Spin-Echo showed superior apparent contrast between static and flowing fluid while GRASS was more sensitive to the very slow flow below 0.17 ml/mim. It was not accurate to calculate flow and velocity below 0.1 ml/min with a modified PC imaging. Conclusion : Four different MR pulse sequences demonstrated different sensitivity to the range of slow flow from 0.08 ml/min to 1.7 ml/min. This finding may be clinically useful to measure CSF shunt flow or detecting CSF collection and thrombosis.

  • PDF

The Performance Comparison of the ISCA and MSCA Algorithm for Adaptive Equalization (적응 등화를 위한 ISCA와 MSCA 알고리즘의 성능 비교)

  • Lim, Seung-Gag;Kang, Dae-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.4
    • /
    • pp.7-13
    • /
    • 2012
  • The performance of blind equalization algorithm ISCA was compared with MSCA that is used for the minimization of the inter symbol interference which occurs in the time dispersive communication channel for digital transmission. Because of the non-linearities of a magnitude and phase transfer characteristics of a communication channel, the transmitting signal will be received that band limited and time dispersived. Therefore the distortion was compensated by using the self adaptive equalizer at the receiving side, then passing through the detector for the decision of "1" or "0". At this time the Constellation Dependent Constant is played an important role in the adaptive equalizer used on the receiver. In order to calculation of this constant, the ISCA and MSCA was used the second order statistics. The ISCA and MSCA which are possible to compensation of mensioned transfer function simulataneously, are improved the performance of original SCA algorithm and then was compared the performance by computer simulation. For this, the recovered constellation, residual isi and MSE was used, and a result of performance comparison, the ISCA algorithm has better than the MSCA in every performance index. But on the steady state of equalizer, the variation of performance due to the CME terms in the MSCA equalization algorithm was less than the ISCA, so MSCA has better stability.

Development of Image Reconstruction Algorithm for Chest Digital Tomosynthesis System (CDT) and Evaluation of Dose and Image Quality (흉부 디지털 단층영상합성 시스템의 영상 재구성 알고리즘 개발 및 선량과 화질 평가)

  • Kim, Min Kyoung;Kwak, Hyeng Ju;Kim, Jong Hun;Choe, Won-Ho;Ha, Yun Kyung;Lee, So Jung;Kim, Dae Ho;Lee, Yong-Gu;Lee, Youngjin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.9
    • /
    • pp.143-147
    • /
    • 2016
  • Recently, digital tomosynthesis system (DTS) has been developed to reduce overlap using conventional X-ray and to overcome high patient dose problem using computed tomography (CT). The purpose of this study was to develop image reconstruction algorithm and to evaluate image characteristics and dose with chest digital tomosynthesis (CDT) system. Image reconstruction was used for filtered back-projection (FBP) methods and system geometry was constructed ${\pm}10^{\circ}$, ${\pm}15^{\circ}$, ${\pm}20^{\circ}$, and ${\pm}30^{\circ}$ angular range for acquiring phantom images. Image characteristics carried out root mean square error (RMSE) and signal difference-to-noise ratio (SDNR), and dose is evaluated effective dose with ${\pm}20^{\circ}$ angular range. According to the results, the phantom image with slice thickness filter has superb RMSE and SDNR, and effective dose was 0.166 mSv. In conclusion, we demonstrated usefulness of developed CDT image reconstruction algorithm and we constructed CDT basic output data with measuring effective dose.

A Study on The Design of China DSRC System SoC (중국형 DSRC 시스템 SoC 설계에 대한 연구)

  • Shin, Dae-Kyo;Choi, Jong-Chan;Lim, Ki-Taeg;Lee, Je-Hyun
    • 전자공학회논문지 IE
    • /
    • v.46 no.4
    • /
    • pp.1-7
    • /
    • 2009
  • The final goal of ITS and ETC will be to improve the traffic efficiency and mobile safety without new road construction. DSRC system is emerging nowadays as a solution of them. China DSRC standard which was released in May 2007 has low bit rate, short message and simple MAC control. The DSRC system users want a long lifetime over 1 year with just one battery. In this paper, we propose the SoC of very low power consumption architecture. Several digital logic concept and analog power control logics were used for very low power consumption. The SoC operation mode and clock speed, operation voltage range, wakeup signal detector, analog comparator and Internal Voltage Regulator & External Power Switch were designed. We confirmed that the SoC power consumption is under 8.5mA@20Mhz, 0.9mA@1Mhz in active mode, and under 5uA in power down mode, by computer simulation. The design of SoC was finished on Aug. 2008, and fabricated on Nov. 2008 with $0.18{\mu}m$ CMOS process.

Influence of ACLSV-infection on Fruit Quality of 'Hongro' Apples (ACLSV(Apple chlorotic leafspot virus) 감염이 사과 '홍로' 품종의 과실품질에 미치는 영향)

  • Kim, Hyun-Ran;Kim, Jeong-Soo;Hwang, Jeong-Hwan;Lee, Sin-Ho;Choi, Gug-Seon;Choi, Yong-Mun
    • Research in Plant Disease
    • /
    • v.10 no.2
    • /
    • pp.145-149
    • /
    • 2004
  • 'Hongro' is one of the most important apple cultivars whose growing area is increasing because of its good quality. Recently fruit shrinking symptom causing decrease of fruit size, juice, and quality, appears in some commercial 'Hongro' orchards. The average frequency of occurrence of fruit shrinking symptom was 12 % of total trees investigated and Apple chlorotic leaf spot virus (ACLSV) was detected from all the trees showing fruit shrinking symptom by ELISA. A typical virus infection symptom of leaf epinasty and stem necrosis appeared on woody indicators, Spy227 and Virginia crab grafted with infected trees and all the grafted trees showed positive reaction to ACLSV antiserum by ELISA. It was proved that ACLSV can be easily transmitted by grafting. ACLSV was also isolated from the leaves of C. quinoa inoculated with sprouting leaf sap of infected trees. To prove that the fruit shrinking symptom was caused by ACLSV infection, ACLSV-infected scion was grafted on virus-free 'Hongro/M9' and the fruit characteristics were investigated. Consequently the same symptoms of fruit size and juice decreasing were observed from the trees grafted with ACLSV-infected scion. Therefore, it is suggested that the fruit shrinking symptom is caused by ACLSV infection and 'Hongro' can be classified as sensitive cultivar to ACLSV.

Effects of Field Configuration Shielding Area and Changing of Density and Sensitivity on Tube Current and Image Quality in Automatic Exposure Control System (자동노출제어장치의 채광창 차폐정도와 농도, 감도의 변화가 관전류량과 영상품질에 미치는 영향)

  • Jeong, Min-Gyu;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.635-642
    • /
    • 2020
  • The purpose of this study was to analysis the effects of shielding area of field configuration with changing of sensitivity and density on tube current (milliampere-seconds, mAs) and image quality in automatic exposure control (AEC) system. The equipment used a digital radiography device (Digital Diagnost, Philips, Netherlands), which has a integral type with an X-ray tube and an indirect digital detector. The AEC system conditions were consisted of 9 setting environments, that mode changing of the sensitivity (S200, S400, S800) and the density (+2.5, 0, -2.5). The tube current evaluated automatically exposed mAs under 81 combination conditions crossed by AEC conditions in fixed at 40 kVp. The image quality evaluated the radiographic images that selected valid images by visual assessment the radiographic images of the self-produced conical pyramid phantom and then measured their signal to noise ratio (SNR). As a result, the maximum tube current was 60.0 mAs that automatically exposed conditions were the 100% of shielding area and the sensitivity of S200 and the density of +2.5. The minimum tube current was 0.9 mAs with non-shielding area and the sensitivity of S800 and the density of -2.5. When the shielded area 0% with the sensitivity of S200 and the density of +2.5, the maximum SNR was the highest as 25.2. But when the shielded area 25% with the sensitivity of S800 and the density of -2.5, the minimum SNR was the lowest as 4.7.

Implementation of the Digital Current Control System for an Induction Motor Using FPGA (FPGA를 이용한 유도 전동기의 디지털 전류 제어 시스템 구현)

  • Yang, Oh
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.11
    • /
    • pp.21-30
    • /
    • 1998
  • In this paper, a digital current control system using a FPGA(Field Programmable Gate Array) was implemented, and the system was applied to an induction motor widely used as an industrial driving machine. The FPGA designed by VHDL(VHSIC Hardware Description Language) consists of a PWM(Pulse Width Modulation) generation block, a PWM protection block, a speed measuring block, a watch dog timer block, an interrupt control block, a decoder logic block, a wait control block and digital input and output blocks respectively. Dedicated clock inputs on the FPGA were used for high-speed execution, and an up-down counter and a latch block were designed in parallel, in order that the triangle wave could be operated at 40 MHz clock. When triangle wave is compared with many registers respectively, gate delay occurs from excessive fan-outs. To reduce the delay, two triangle wave registers were implemented in parallel. Amplitude and frequency of the triangle wave, and dead time of PWM could be changed by software. This FPGA was synthesized by pASIC 2SpDE and Synplify-Lite synthesis tool of Quick Logic company. The final simulation for worst cases was successfully performed under a Verilog HDL simulation environment. And the FPGA programmed for an 84 pin PLCC package was applied to digital current control system for 3-phase induction motor. The digital current control system of the 3 phase induction motor was configured using the DSP(TMS320C31-40 MHz), FPGA, A/D converter and Hall CT etc., and experimental results showed the effectiveness of the digital current control system.

  • PDF

Clinical Usefulness of 99mTc-DMSA Renal SPECT Using High Sensitivity-All Purpose Collimator for Pediatric Patients (고감도 범용성 콜리메이터를 이용한 소아 환자 99mTc-DMSA 신장 SPECT의 유용성)

  • Kim, Jin-Eui;Kim, Jung-Soo;Han, Jae-Bok;Choi, Nam-Gil
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.3
    • /
    • pp.219-231
    • /
    • 2016
  • $^{99m}Tc$-DMSA planar scan that can analyze the functions of kidney quantitatively provides less information on a lesion than tomography scanning. Therefore, this study applied a high sensitivity all-purpose collimator that is sensitive to photonic signals to $^{99m}Tc$-DMSA and carried out a clinical scan with single photon emission computed tomography (SPECT). And diagnostic accuracy and time requirement of were analyzed to know the clinical usefulness of the applied scanning method. 10 subjects were intravenously injected with radiopharmaceutical product (1.0-1.2 MBq/kg) and scanned by a gamma camera with planar scanner (high resolution (HR)-mode, $256{\times}256$, 50 kcts/view, 4 image) and SPECT (HR / high sensitive (HS)-mode, $128{\times}128$, step and shoot, $180^{\circ}$, variable sec/angle, total 64 frame, OSEM reconstruction), respectively. The collected data was compared with an analysis program. The results showed that HS-mode SPECT detected total counts 1.8-5.6 times more than planar scan. Relative renal function evaluated based on the counts was not significantly different by two scanning methods (p=0.96) and it turned out that test time was shortened by 39% when HS-mode SPECT was used. Therefore, SPECT using HR, HS-mode collimator could analyze renal function more quantitatively than using planar scan and the former could diagnose the location information of a lesion more accurately than the latter as well as shortened test time requirement, which demonstrated the clinical usefulness of $^{99m}Tc$-DMSA renal SPECT using high sensitivity all purpose collimator.