• Title/Summary/Keyword: 신호대 잡음 비

Search Result 1,296, Processing Time 0.031 seconds

A Study on a Robust Voice Activity Detector Under the Noise Environment in the G,723.1 Vocoder (G.723.1 보코더에서 잡음환경에 강인한 음성활동구간 검출기에 관한 연구)

  • 이희원;장경아;배명진
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.173-181
    • /
    • 2002
  • Generally the one of serious problems in Voice Activity Detection (VAD) is speech region detection in noise environment. Therefore, this paper propose the new method using energy, lsp varation. As a result of processing time and speech quality of the proposed algorithm, the processing time is reduced due to the accurate detection of inactive period, and there is almot no difference in the subjective quality test. As a result of bit rate, proposed algorithm measures the number of VAD=1 and the result shows predominant reduction of bit rate as SNR of noisy speech is low (about 5∼10 dB).

Real-time MCG Signal Processing System (실시간 심자도 신호처리 시스템)

  • Chung, D.H.;Lim, J.S.;Kim, P.K.;Ko, K.H.;Lee, D.H.;Kim, H.J.;Ahn, C.B.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2685-2686
    • /
    • 2004
  • 심자도(Magnetocardiography: MCG)는 심장에서 발생하는 자기신호로 크기가 수 pico Tesla에서 수 femto Tesla 정도로 지구 자기에 비하여 $10^{-6}{\sim}10^{-10}$ 정도로 매우 작기 때문에 보통 3층의 차폐 막 구조로 되어 있는 자기차폐실을 사용하여 외부 잡음을 줄인다. 그러나 자기차폐실의 비용이 크기 때문에, 자기차폐실의 비용을 줄이고 다양한 신호처리를 병행하여 신호대 잡음비를 높이고 있다. 본 논문에서는 1Giga FLOPS (FLoating point Operationals Per Second)의 부동 소숫점 연산능력을 가진 TMS320C6701을 사용하여 실시간 신호처리가 가능한 신호처리 시스템을 설계하였다. 개발된 DSP 보드는 PCI-bus 기반으로 설계하여 신호 측정 컴퓨터에 내장이 가능하도록 하였다. 프로그램과 데이터 처리를 위한 외부 메모리를 장착하였고, PCI 콘트롤러를 갖추어 PC 와의 대용량 메모리 공유가 가능하도록 하였다. 제작된 DSP 보드를 사용하여, 심자도 신호에서 실시간으로 적응 잡음 소거 및 필터링을 구현하여 신호대 잡음비의 향상을 확인할 수 있었다.

  • PDF

Voice Activity Detection Algorithm using Wavelet Band Entropy Ensemble Analysis in Car Noisy Environments (자동차 잡음 환경에서 웨이브렛 밴드 엔트로피 앙상블 분석을 이용한 음성구간 검출 알고리즘)

  • Lee, G.H.;Lee, Y.J.;Kim, M.N.
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.9
    • /
    • pp.1005-1017
    • /
    • 2013
  • Voice activity detection is very important process that voice activity separated form noisy speech signal for speech enhance. Over the past few years, many studies have been made on voice activity detection, but it has poor performance in low signal to noise ratio environment or fickle noise such as car noise. In this paper, it proposed new voice activity detection algorithm using ensemble variance based on wavelet band entropy and soft thresholding method. We conduct a survey in a lot of signal to noise ratio environment of car noise to evaluate performance of the proposed algorithm and confirmed performance of the proposed algorithm.

Evaluation of Image Quality When Using Grid During Child Chest X-Ray Examination (소아 흉부검사 시 격자 사용에 따른 영상 화질 평가)

  • Jeung, Seung-Hun;Han, Beom-Hul;Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.371-376
    • /
    • 2017
  • Since in case of children, they are sensitive to the radiation compared to the adult and the potential exposure damage lasts longer, the exposure dose should be managed better than for the adult. Therefore, this study was conducted to observe the change in the chest x-ray image by the use of grid, which eliminates the scattering rays but increases the exposure dose during the child chest x-ray examination. As a research method, SNR, CNR and V. Vuichi were measured at 100 cm and 180 cm with the grid varying the kVp to 70, 90 and 110. In addition, SNR, CNR and V. Vuichi were measured fixing 100 cm and 180cm without grid and varying the dose to 6, 8 and 10 mAs. In the results of measuring them by fixing kVp, SNR, VNR and V. Vuichi were represented high when FID is 100cm. And in the results of meaduring them varying mAs, SNR, VNR and V. Vuichi were represented high when FID is 100cm. Currently in our country, the chest x-ray examination is performed at 180 cm. However, as the image is measured high when FID is 100 cm, in case of child, FID is deemed to be 100 cm.

Comparative assessment of a 1.5T endorectal coil and a 3.0T phased-array coil available for prostate MRI (전립선 MRI에서 사용하는 1.5T 경직장 코일과 3.0T 위상 배열 코일의 성능 비교 평가)

  • Cho, Jae-Hwan
    • Journal of Digital Contents Society
    • /
    • v.11 no.3
    • /
    • pp.283-290
    • /
    • 2010
  • The effectiveness of 3.0T phase array coil images was tested by comparing signal-to-noise ratios for the same coil images relative to 1.5T endorectal coil images. Signal intensities were measured in the three regions of prostate, central and peripheral (right and left) after 40 patients with prostate cancer were imaged during the period between Jan. 2008 and Oct. 2009 with T2 W, T1 W, and DW images obtained respectively using endorectal coil on a 1.5T MR scanner and phase array coil on a 3.0T MR scanner. For quantitative analysis, comparisons of average SNRs for the same ROIs were made between groups scanned with a 1.5T and a 3.0T MR scanner. The signal-to-noise ratios were shown to increase more sharply when using a phase array coil at a 3.0T MR scanner compared to using an endorectal coil at a 1.5T MR scanner.

A Study on Signal-to-Noise Ratio of Delta Modulation for a First-Order Gauss-Markov Signal (First-Order Gauss-Markov 신호에 대한 Delta 변조방식의 신호대 잡음비에 관한 연구)

  • Moon, Sang-Jae;Son, Hyun
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.17 no.3
    • /
    • pp.52-56
    • /
    • 1980
  • The Signal -to- Noise Ratio of delta modulation for a fi rEt -order Gauss -Markov signal is derived and an approximate expreession of SND is discussed, in the case that only granular noise arises. Cross covariance of input and error signals are negligible when the adjacent correlation of input signal is larger than the difference between the adjacent correlation and the prediction coefficient of local decoder. The approximately derived SNR is available for any value of adjacent correlation.

  • PDF

De-Noising of Electroretinogram Signal Using Wavelet Transforms (웨이브렛 변환을 이용한 망막전도 신호의 잡음제거)

  • Seo, Jung-Ick;Park, Eun-Kyoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.203-207
    • /
    • 2012
  • Purpose: Electroretinogram(ERG) signal noise as well as conducting other bio-signal measurement were generated. It was intened to enhance the accuracy of retinal-related diagnosis with removing signal noise. Methods: Sampling signal was made with generating 60 Hz noise and white noise. The noise were removed using wavelet transforms and bandpass filter. De-noising frequency was compared with Fourier transform spectrum. Removed noises were compared numerically using SNR(signal to noise ratio). Results: The result compared Fourier transform spectrum was showed that 60 Hz noise removed completely and most of white noise was removed by wavelet transforms. 60 Hz and the white noise remained using bandpass filters. The result compared SNR showed that wavelet transforms was 22.8638 and bandpass filter was 4.0961. Conclusions: Wavelet transform showed less signal distortion in removing noise. ERG signal is expected to improve the accuracy of retinal-related diagnosis.

Study on the Change of Absorbed Dose and Image Quality according to X-ray Condition of Detector in Digital Radiography(DR) (Digital Radiography(DR)에서 검출기의 X선 조건에 따른 흡수선량 및 영상화질 변화에 관한 연구)

  • Hwang, Jun-Ho;Jeong, Jae-Ho;Kim, Hyun-Soo;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.9
    • /
    • pp.99-106
    • /
    • 2017
  • This study focused on the issue that when a diagnostic detector is found to have a defect, a patient would be exposed to radiation and image quality would be degraded. Though dose analysis, an experiment was conducted to evaluate detector performance as Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR). Absorbed dose, SNR and CNR were measured using a dosimeter and a tissue equivalent phantom. The experiment was conducted to compare whether the dose value shown after being attached to the back side of the phantom matches the dose value attached behind the detector, where in the conditions of skull, chest and abdomen were set at 75 kVp, 25 mAs, 110 kVp, 8 mAs, and 80 kVp, 20 mAs, respectively. As a result, there was a difference in that the dose values attached to the back side of the detector were 0.004 mGy, 0.006 mGy, 0.003 mGy, whereas those of the back side of the phantom were 0.006 mGy, 0.016 mGy, 0.017 mGy. In order to match both values, the condition was increased and SNR and CNR also increased from 88.32, 88.10, 4.09, 1.63, 87.94, 79.97 to 93.87, 93.75, 4.91, 4.03, 92.02, 84.92. Though this study, we found that when a detector is found to have a aging, it shortens the life of equipment and increases the dose of a patient, also the improvement effect of image quality is inadequate.

A Turbo Coded Multicarrier DS/CDMA System with Unequal Diversity Order Assignment to Coded Symbols (부호심벌에 다양성 차수를 다르게 둔 터보 부호화 여러반송파 직접수열 부호분할 다중접속 시스템)

  • 김윤희;권형문;송익호;정창용
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.10A
    • /
    • pp.1782-1793
    • /
    • 2001
  • 터보부호 심벌비트들을 서로 다른 부호율로 반복부호화한 뒤 여러 부채널로 나란히 보내는 터보 부호화 여러반송파 직접수열 부호분할 다중접속 시스템을 제안한다. 레일리 감쇄채널에서 신호대잡음비가 높을 때에는 이 시스템의 성능 한계를 얻었고, 신호대잡음비가 낮아 한계를 적용할 수 없을 때에는 모의실험에서 성능을 살펴보았다. 신호대잡음비가 낮을 때 성능 손실이 조금 있지만 홀짝 검사(parity check) 심벌에 다양성 차수를 크게 주어 오류 마루를 (error floor) 낮출 수 있음을 보였다.

  • PDF

Estimation of Wide-Band Acoustic Measurement Accuracy Based on Confidence as Variation of Signal-to-Noise Ratio (신호대잡음비에 따른 신뢰도 기반의 광대역 음향측정 정확도 예측)

  • 도경철;최재용;손경식
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.8
    • /
    • pp.93-97
    • /
    • 1998
  • 미지신호에 대한 측정에서는 오차분산의 명확한 표현이 어렵다. 본 연구에서는 이와 같은 수동측정에서의 측정정확도를 예측하기 위한 방법을 정립한다. 제안된 예측 방법은 신 뢰도를 기반으로 신호대잡음비 및 주파수대역폭과 시간적분과의 곱에 의해 정확도를 표현한 다. 본 논문에서는 배경소음 환경에서의 측정음향을 그대로 분석하는 경우와 배경소음을 예 측하여 측정음향에서 제거시키는 경우를 구분하여 광대역 음향측정시의 성능예측 기준을 시 뮬레이션하고 정확도를 예측한다.

  • PDF