• Title/Summary/Keyword: 신장 기능

Search Result 765, Processing Time 0.027 seconds

The Quantitative Assessment of Renal Function and Size by Differences of Acquisition Counts in $^{99m}Tc$-DMSA Renal Scan ($^{99m}Tc$-DMSA 신장검사에서 획득 계수의 차이에 따른 기능 및 형태 평가)

  • Shim, Dong-Oh;Kim, Ho-Sung;Chung, Eun-Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.117-121
    • /
    • 2010
  • Purpose: In nuclear medicine study, there are two methods, preset count method and preset time method, to acquire static images. We usually use preset count method for static image in $^{99m}Tc$-DMSA renal scan, but occasionally use preset time method. In case of using preset count method, we always acquire same counts but it causes a difference of scan time. In case of using preset time method, it takes same scan time to acquire images but it causes different counts. Therefore, the purpose of this study is to investigate any differences of function and formal information in both kidney by acquisition counts Materials and Methods: From January 11, 2010 to March 31, 2010, we analyzed the 30 patients (M: 11, W: 19). who were examined by $^{99m}Tc$-DMSA scan and have one side of functioning kidney relatively between 40~60%. And the patients who have cold and hot region in image were analyzed but we did not accept images of patients when it was hard to divide kidney into cortex. There was no division between subjects and age of subjects is $14.83{\pm}22.07$ old. We used the BrightView gamma camera from PHILIPS. To analyze function and formal of kidney, we used JET stream release 3.0 version from PHILIPS. Using SPSS 12.0 program, we compared descriptive statistics and paired T-test. Images were acquired sequentially in the same parameters, but there are three methods which different from acquisition time and scan time, 100 kcounts, 300 kcounts and 7 minutes method (exceed 300 kcounts). To assess function and formal information of kidney, we measured renal relative function, geometric mean and size of kidney and analyzed each difference. Results: In case of renal relative function in both kidney, 100 kcounts method was $50.52{\pm}3.64%$. 300 kcounts method was $50.38{\pm}3.66%$ and 7 minutes method was $49.91{\pm}3.40%$ and there were no statistical significant differences between each method. In case of geometric mean, 100 kcounts method was $50.08{\pm}3.25%$. 300 kcounts method was $49.89{\pm}3.40%$ and 7 minutes method was $49.91{\pm}3.24%$. And also, there were no statistical significant differences. When comparing size of kidney, 100 kcounts method was $8.23{\pm}1.96$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.35{\pm}1.97$ cm. In case of right kidney, 100 kcounts method was $7.91{\pm}1.88$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.25{\pm}1.96$ cm. From those values, we recognized that there were significant differences each method (p<0.05). Conclusion: From results of this study, there were no statistical differences in renal relative function and geometric mean by acquisition counts. However, in shape of kidney, the more acquisition counts are increasing, the more size of kidney is getting big. And there were statistical significant differences. Therefore, to perform reliable quantitative result, preset count method is more desirable than preset time method. Especially, in case of a follow-up test, if we use preset time method, it will cause differences of formal results in kidney due to acquisition counts each time we examine patients.

  • PDF

A Novel Method of Measuring the state of Kidney by Analysing the Color and Gloss of the Patient's Face (안면 색윤(色潤) 분석을 통한 신장 기능 측정 방법 제안)

  • Lee, Se-Hwan;Cho, Dong-Uk;Kang, Eung-Taek
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.7C
    • /
    • pp.634-641
    • /
    • 2010
  • End Stage Renal Disease resulting from complications of the 4 top causes of death including diabetes and hyperpiesia becomes one of the major social problems these days in the context that this disease unaffordably increases the medical cost and decreases the quality of life. For a kidney disease, it is hard to diagnose, cure and recover as there are few subjective symptoms. Therefore, the prevention is very important. In this paper, we propose a method, which checks the abnormal state of the kidney, using the patient's face color and gloss which is employed for diagnosis in the oriental medicine. This method composes of two processes. The first is to acquire the patient's face data applying a polarizing filter and the next is to analyse relations between kidney disease and this data.

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

Discrepancy and Correlation in the renal length between Kidney CT and 99mTc-DMSA Renal scan (신장 CT 검사와 99mTc-DMSA Renal Scan 검사에서 측정한 신장 길이의 차이 및 상관분석)

  • Jung, Woo-Young;Shim, Dong-Oh;Lee, Dong-Hun;Choi, Jae-Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.1
    • /
    • pp.15-20
    • /
    • 2021
  • Purpose This article studies the relationship between the length of a kidney measured by two scanning methods: Kidney Computed Tomography (CT) and 99mTc-Dimercaptosuccinic acid (DMSA) renal scan. Kidney CT provides a better anatomic assessment, while 99mTc-DMSA renal scan is superior in the kidney function test. Materials and Methods From January to December of 2019, two hundred patients who had Kidney CT and Tc99m-DMSA renal scan were chosen for this study. SPSS17.0 was selected for statistical analysis. Results Due to the effect of the breathing and resolution of 99mTc-DMSA renal scan, it showed the kidney's relatively longer length than the length of Kidney CT. For the same kidney, the length comparison among different brands' Gamma cameras was negligible. The length difference within the same age group did not show a noticeable discrepancy. However, there was a length difference between the radio technologists. Kidney CT and 99mTc-DMSA renal scan indicated a strong positive correlation between the length of the left and right kidney. Conclusion It is necessary to establish a standardized measurement method for measuring kidney length using 99mTc-DMSA renal scan. The kidney's functional changes and length changes are indications of Kidney diseases. Especially, pediatric patients tend to use 99mTc-DMSA renal scan for assessing the kidney's shape and the function to avoid potential radiation exposure during the Kidney CT. Therefore, it is significant to provide not only the kidney's functional information but also an anatomic analysis, including the kidney's size, length, and location through the 99mTc-DMSA renal scan.

당뇨병환자의 신장이야기-당뇨병환자의 신장합병증 치료

  • Gang, Jong-Myeong
    • The Monthly Diabetes
    • /
    • s.214
    • /
    • pp.15-18
    • /
    • 2007
  • 당뇨병은 혈액 속에 포도당이 높아져 이에 따른 각종 합병증 때문에 심각한 후유증을 초래할 수 있는 질환이다. 이 중에서 신장 합병증은 중요한 당뇨병 합병증 가운데 하나이다. 당뇨병성 신증은 거의 모든 당뇨병환자에게서 나타난다. 당뇨병성 신증의 마지막은 신장 기능이 거의 다 망가져 혈액투석이나 복막투석을 받는 말기신부전 환자의 가장 흔한 원인이 바로 당뇨병이므로 당뇨병의 신장 합병증을 줄이는 것이 환자의 삶의 질과 직결되는 문제라 할 수 있다. 신장합병증은 초기에는 증상이 잘 나타나지 않아 항상 주의가 필요하다. 신장이 손상되기 시작하면 단백뇨가 계속 나오고 혈압이 오르며 빈혈이 발생하고 몸이 붓는다. 이런 현상은 포도당의 대사물질이 사구체에 쌓이기 때문이다. '사구체'란 신장 안에서 오줌을 거르는 일을 하는 모세혈관 조직으로 일단 손상되면 회복되지 않고 진행되며 이 상태를 그대로두면 결국 더 이상 신장에서 혈액의 노폐물을 걸러내지 못하는 만성 신부전증으로 진행하게 되는 것이다.

  • PDF

'어디가 피로한가에 따라 건강 확인하기'<1>

  • Korea Environmental Engineers Federation
    • Environmental engineer
    • /
    • v.22 s.230
    • /
    • pp.98-99
    • /
    • 2005
  • 아침에 일어날 때 피로하다면 신경계 이상에 의한 피로일 수 있다. 과로도 안했는데 오후만 되면 움직이지 못하게 피곤하다면 질병일 수 있다. 이렇듯 피로한 부위가 어딘가에 따라 건강을 확인해볼 수 있다. 눈이 피곤하다면 간이 약한 것이다. 또 눈 주위에 붉은 핏줄이 선다면 심장이 약한 것이다. 눈꺼풀이 붓고 눈물이 많아지며 집중력이 떨어진다면 비장에 이상이 있다고 볼 수 있다. 아래 눈꺼풀이 붓고 눈이 침침하며 어지럽다면 신장기능을 점검해볼 필요가 있다. 이가 들뜨고 시큰거리며 피로하다면 위가 나쁜 것이고, 손발이 나른하며 붓고 움직이기 싫다면 비장이 나쁘다고 할 수 있다. 또 팔 다리 관절 및 허리와 무릎 관절이 쑤시고 피로하다면 비장과 신장이 약한 것이다. 목소리에 힘이 없으면 기가 허한 것이고 방광기능도 살펴야 한다. 목소리가 자주 가라앉고 잘 쉬면 신장기능을 점검해야 한다. 또 목소리가 몹시 조급한 느낌이 들면 폐기능 장애를 의심해볼 수 있다.

  • PDF

Development of Automated Region of Interest for the Evaluation of Renal Scintigraphy : Study on the Inter-operator Variability (신장 핵의학 영상의 정량적 분석을 위한 관심영역 자동설정 기능 개발 및 사용자별 분석결과의 변화도 감소효과 분석)

  • 이형구;송주영;서태석;최보영;신경섭
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.41-50
    • /
    • 2001
  • The quantification analysis of renal scintigraphy is strongly affected by the location, shape and size of region of interest(ROI). When ROIs are drawn manually, these ROIs are not reproducible due to the operators' subjective point of view, and may lead to inconsistent results even if the same data were analyzed. In this study, the effect of the ROI variation on the analysis of renal scintigraphy when the ROIs are drawn manually was investigated, and in order to obtain more consistent results, methods for automated ROI definition were developed and the results from the application of the developed methods were analyzed. Relative renal function, glomerular filtration rate and mean transit time were selected as clinical parameters for the analysis of the effect of ROI and the analysis tools were designed with the programming language of IDL5.2. To obtain renal scintigraphy, $^{99m}$Tc-DTPA was injected to the 11 adults of normal condition and to study the inter-operator variability, 9 researchers executed the analyses. The calculation of threshold using the gradient value of pixels and border tracing technique were used to define renal ROI and then the background ROI and aorta ROI were defined automatically considering anatomical information and pixel value. The automatic methods to define renal ROI were classified to 4 groups according to the exclusion of operator's subjectiveness. These automatic methods reduced the inter-operator variability remarkably in comparison with manual method and proved the effective tool to obtain reasonable and consistent results in analyzing the renal scintigraphy quantitatively.

  • PDF

A Holistic Study of the Physiology of the Kidney and its Symptom (신장생리(腎臟生理)의 유기적 통일성과 그 병후(病候)에 관한 고찰)

  • Suh, Man-Wan;Kim, Gil-Whon
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.7 no.2
    • /
    • pp.1-8
    • /
    • 1999
  • This paper documents a holistic study of the kidney and its symptom. To this end, the relationship between internal organs and its diseases have been studied from th e viewpoint of the connecting role of the kidney channel of foot-shaoyin. The results of this study are as follows; The function of the kidney has specific re lations with the liver, lung, heart, urinary bladder, throat, tongue, chest, sole of the foot, inside of the thigh and waist. These mutual relations reflect the pathological changes of the kidney. So physiological function and symptom of the kidney can be better understood throu gh the connecting role of the kidney channel of foot-shaoyin on the concept of the organism as a whole. This is the key of the clinical treatment based on the precept sof oriental medicine.

  • PDF

Comparison for Glomerular Filtration Rate in Gamma Camera Systems Using Dynamic Renal Phantom System (동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교)

  • Kang, Chun Goo;Park, Hoon-Hee;Oh, Shin Hyun;Lee, Han Wool;Kim, Jung Yul;Oh, Joo Yung;Lee, Ju Young;Kim, Jae Sam;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.3-9
    • /
    • 2013
  • Purpose: Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desire to evaluate the usefulness of nuclear medicine imaging. Materials and Methods: The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc-pertechnate$. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn ten times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Results: Under the same conditions infusion rate 40 mL/min fixed to adjust the pressure of the pump when the radiopharmaceuticals between 2-3 minutes in the most integrated in the kidney phantom was excreted inthe bladder. Glomerular filtration rate (GFR), respectively, by each device SYMBIA 1,091 mL/min, FORTE 1,232 mL/min, ARGUS 1,264 mL/min, INFINIA 1,302 mL/min in that there isno statistically significant difference was found, Tmax values and T1/2 values stars from all equipment with no statistically significant difference was found. CV values of the coefficient of variation less than 5% was found to be repeatable, and to 2.67% of the lowest SYMBIA appeared, INFINIA was the highest in the 4.86%. Conclusion: Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF