• Title/Summary/Keyword: 신뢰성 제어

Search Result 1,550, Processing Time 0.027 seconds

Practical Improvement of An Efficient Public-Key framework and Its Application (효율적인 공개키 프레임워크에 대한 실용적 개선과 응용)

  • Yang Jong-Phil;Shin Weon;Rhee Kyung-Hyune
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.4C
    • /
    • pp.472-481
    • /
    • 2006
  • J. Zhou et al. proposed a new public-key framewort in which the maximum lifetime of a certificate is divided into short periods and the certificate could be expired at the end of any period under the control of the certificate owner(or his manager in a corporate environment). However, J. Zhou et al.'s public-key framework is not suitable on implementation in real world. Therefore, we review some security Parameters to change them into more suitable ones for implementation and remove an unnecessary trust party of J. Zhou et al.'s public-key framework. Then, we propose an improved scheme for realistic solution. Moreover, we present a practical application based on the improved framework.

A Study on the Auto Closing Systems Motion Analysis of Door in Smoke Control Zone (제연구역 출입문의 자동폐쇄장치 운동해석에 관한 연구)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.106-112
    • /
    • 2010
  • This study carried out the motion analysis of auto closing systems as basis study for development of auto closing systems for door in smoke control zone. This study established process of auto closing systems and analysis theory based on kinematics mechanism thesis and mechanism modelling of auto closing control units. And this study established engineering data construction and a source technology that can design each element of auto closing control units that choose closing force units through motion analysis simulation based on analysis theory. Therefore, it can give flexibility and elasticity of auto closing units development from this study. Also, it sees that can ready control means and technological countermeasure of smoke by development of auto closing units and secure high reliancity and stability of smoke control systems.

Voltage Sag-Swell Generator for Power Quality Disturbance of Dynamic UPS System (다이나믹 UPS 시스템의 전력품질 외란발생을 위한 전압 Sag-Swell 발생기)

  • Byeon W. Y.;Kim J. W.;Lee K. S.;Nho E. C.;Kim I. D.;Chun T. W.;Kim H. G.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.102-107
    • /
    • 2005
  • This paper describes a new voltage sag-swell generator for the test of custom power devices such as UPS, DVR, DSTATCOM, SSTS, etc. Voltage sag, swell, outage, and unbalance generation mechanism and the operating principle are described for the proposed scheme. The usefulness of the scheme is proved through simulations and experiments. The proposed scheme has good features of simple structure, high reliability, wide range of sag and swell variation, and easy control. Especially, the scheme can provide a cost-effective implementation of a power quality disturbance generator. Therefore, it is expected that the scheme will contribute to the self implementation of the system with low cost in laboratory.

The Comparative Analysis of Water Quality Environment Data of Wando Onshore Seawater Farm and Tidal Observatory (완도 육상 해수 양식장과 조위관측소의 수질 환경 데이터 비교 분석)

  • Ye, Seoung-Bin;Kwon, In-Yeong;Kim, Tae-Ho;Park, Jeong-Seon;Han, Soon-Hee;Ceong, Hee-Taek
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.5
    • /
    • pp.957-968
    • /
    • 2021
  • To improve the data on reliability of the onshore fish farm water quality monitoring system and operate the system efficiently, the water quality data of the onshore seawater fish farms which are progressing test operation, and the marine environmental information network(Wando tidal station) were compared and analyzed. Furthermore, data validation, data range filters, and data displacement checks were applied to analyze the data in a way that eliminates the data errors in water quality monitoring systems and increases the reliability of measurement data.

On the Calibration of Impact Hammer Sensitivity (충격 해머의 감도보정)

  • 한상보
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.71-74
    • /
    • 1991
  • 구조물의 진동특성을 파악하기 위한 실험적 모우드 해석법에서 기진력을 제 공하는 한 방법으로 힘 측정기가 부착된 해머를 이용한 충격시험기법이 널 리 사용되고 있다. 충격해머 시험의 유용성은 기진력의 에너지가 정현파 기 진력의 경우처럼 특정 주파수대에 산재해 있는 것이 아니라 가용 주파수 영 역내에 연속적으로 분포해 있다는 점이며 이러한 충격력은 가용 주파수 범 위내에 있는 모든 고유진동형을 여가시킬 수 있다는 장점이 있다. 충격헤머 가 가지고 있는 동적특성은 구조물을 가진시키는 선형충격량의 크기를 결정 하며, 이는 다시 충격력의 크기와 가용 주파수 범위를 결정하게 된다. 일반 적으로 가진주파수 범위는 해머의 질량에 반비례하고 충격해드의 경도에 비 례하는 것으로 알려져 있다. 해머의 질량 자체가 충격력의 크기를 좌우하기 도 하므로, 가진력의 크기를 고려하여 해머의 질량이 선택되며 충격헤드는 충격시간을 조절하기 위하여 적절히 선택된다. 충격해머에 장착된 힘측정기 의 감도는 해머질량과 충격헤드의 질량 변화에 영향을 받게 되는데, 충격 시 험시 측정되는 값은 해머에 부착되어 있는 힘측정기에 가해지는 힘인 반면 구조물에 가해지는 기진력은 충격해드와 구조물사이에 발생되는 힘이다. 이 두 힘의 비는 해머 및 충격해드의 질량효과에 따라 좌우된다. 주어진 충격시 험에서 충격해머의 질량효과를 정확히 조건에 따라 감도보정을 해 주어야 한다. 충격해머의 감도보정에 대해서는 문헌[2]에 잘 나타나 있다. 본 논문에 서는 전압감도에 미치는 영향을 파악하고자 질량 효과를 고려한 수학적 모 형을 제시하고 그 모형의 타당성을 실험을 통해 검정하고자 한다.방법 을 제시하였다. 이와 아울러 제어계의 환경변화에 따른 파라메타의 변화에 적응적으로 응답이 가능해야 하는 적응 소음제어 시스템에서, 음향궤환과 함 께 필히 고려해야 하는 부가적인 전달함수의 영향을 고려한 능동 소음제어 에 대해 연구하였다. 경량화 추세에 따라 지반이나 케이싱이 경량이거나 유연하여 회전축과 동적으로 연성된 경우 회전축-베어링-지반으로 이루어진 2중구조의 회전축 계 동특성을 해석할 수 있는 프로그램을 개발하므로서 회전 기계류의 진동 전반에 걸친 문제점에 대한 그 원인과 현상을 명확히 분석하여 국내의 전기 계류의 보다 신뢰성있는 설계 및 제작자료를 확보하는데 기여할 수 있게 하 였다.존의 small molecular Gd-chelate에 비해 매우 큼을 알 수 있었다. MnPC는 간세포에 흡수된 후 담도계로 배출되는 간특이성 조영제임을 확인하였다. 장비 내에서 반복 시행한 평균값의 차이는 대체적으로 유의한 차이가 없었으나, 다른 장비에서 반복 시행한 장비간의 사이에는 유의한 차이가 있는 경우가 더 많았다. 따라서 , MRS 검사를 소뇌나 뇌교의 어떤 절환에 적용하기 전에 각 장비 마다 정상 기준치를 반드시 얻은 후에 이상여부를 판 정하는 것이 필수적이라고 생각된다.EX> 이상이 적절한 진단기준으로 생각되었다. $0.4{\;}\textrm{cm}^3$ 이상의 좌우 부피차를 보이는 모든 증례에서 육안적으로도 해마위축이 뚜렷이 나타났다. 결론 : MR영상을 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다

  • PDF

Battery Level Calculation and Failure Prediction Algorithm for ESS Optimization and Stable Operation (ESS 최적화 및 안정적인 운영을 위한 배터리 잔량 산출 및 고장 예측 알고리즘)

  • Joo, Jong-Yul;Lee, Young-Jae;Park, Kyoung-Wook;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.1
    • /
    • pp.71-78
    • /
    • 2020
  • In the case of power generation using renewable energy, power production may not be smooth due to the influence of the weather. The energy storage system (ESS) is used to increase the efficiency of solar and wind power generation. ESS has been continuously fired due to a lack of battery protection systems, operation management, and control system, or careless installation, leading to very big casualties and economic losses. ESS stability and battery protection system operation management technology is indispensable. In this paper, we present a battery level calculation algorithm and a failure prediction algorithm for ESS optimization and stable operation. The proposed algorithm calculates the correct battery level by accumulating the current amount in real-time when the battery is charged and discharged, and calculates the battery failure by using the voltage imbalance between battery cells. The proposed algorithms can predict the exact battery level and failure required to operate the ESS optimally. Therefore, accurate status information on ESS battery can be measured and reliably monitored to prevent large accidents.

P2P Streaming Method for QoS-sensitive Multimedia Multicast Applications (QoS에 민감한 멀티미디어 멀티캐스트 응용을 위한 P2P 스트리밍 기법)

  • Park, Seung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.9
    • /
    • pp.68-78
    • /
    • 2010
  • As the IP multicast function is very slowly deployed in Internet due to its scalability problem and inter-domain interoperability problem, interest in the P2P(Peer-to-Peer) streaming technologies for the realtime multimedia multicast applications such as IPTV is highly growing. This paper proposes a P2P streaming method for the QoS-sensitive multimedia multicast applications such as highly-interactive personal IPTV and video conferences. The proposed P2P streaming method allows an application to construct a reliable streaming tree in which a proper number of backup peers are placed according to its reliability requirement. The reliable streaming tree reduces the reconnection delay, occurred in the case of a normal and/or abnormal peer leave, so as to minimize the loss of streaming data. In the proposed P2P streaming method, the join delay of a peer called startup delay is also substantially reduced because the bandwidth and end-to-end delay information of every peer kept in a distributed way allows the target peer for a joining peer to be able to be quickly determined. Moreover, the proposed method's peer admission control mechanism based on the bandwidth and end-to-end delay enables the delay-bounded streaming services to be provided for its corresponding applications.

A study for Secure the Reliability of Automated Guided Vehicle Remote Control System (무인운반차 RCS(Remote Control System)의 신뢰확보를 위한 연구)

  • Jeon, Hyong-Mo;Kang, Sang-Won
    • Journal of Digital Convergence
    • /
    • v.15 no.5
    • /
    • pp.207-215
    • /
    • 2017
  • With rapid development of IT technology and biotechnology, human lifespan is extended rapidly, and we are living in the era where aging becomes the social issue. Due to this aging problem, manpower is mainly replaced by Automated Guided Vehicles (AGV) in manufacturing factories or warehouse logistics transportation. Rate of AGV use increases sharply every year. AGVs, which were used only in Smart Factories, extends its usage into indoor and outdoor operation by changing their usages to container transportation that can carry huge containers in the harbor. With the expansion of AGVs usage, the importance of RCS (Remote Control System) is also increased. In this study, we surveyed and analyzed the characteristics and technology trends of technical features of AGV's RCS that are developing in various ways to establish quality evaluation system of AGV RCS. Based on this, and by referring to international quality assessment standards, ISO/IEC 25000 series, we derived evaluation items on functional suitability and usability to secure reliability of AGV RCS. Also, it is our intention to develop evaluation model using those derived usability and reliability evaluation items.

Performance Evaluation of MAC Protocols Considering Various Input Traffic in WDM Metro Ring Networks (WDM 메트로 링 망에서 다양한 입력 트래픽을 고려한 MAC 프로토콜의 성능분석)

  • Lee, Kyu-Jeong;So, Won-Ho
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.10d
    • /
    • pp.24-29
    • /
    • 2006
  • 본 논문에서는 광대역 통신 방송 융합 서비스 제공을 고려한 WDM 메트로 링 망을 위한 매체 접근 제어(Medium Access Control; MAC) 프로토콜의 성능을 분석한다. 현재 인터넷은 통신 방송 융합 망으로 진화하고 있으며 다양한 트래픽 특성을 갖는 서비스가 액세스 망에서 메트로 망으로 유입되고 있다. 그러나 기존 메트로 망의 MAC 프로토콜은 이러한 망 환경 변화를 고려하지 않고 단순하고 동일한 트래픽만을 고려하여 성능을 분석하였다. 따라서 본 논문에서는 메트로 링에 연결된 액세스 노드의 입력 트래픽을 Self-Similar와 Poisson 트래픽으로 분류하여 기존 MAC 프로토콜의 성능을 분석하고 평가한다. 메트로 링 망에 연결된 액세스 노드는 이 두 종류의 트래픽 중에서 하나를 망에 유입하며 채널을 공유하는 노드 수에 따라서 다양한 트래픽 환경이 고려된다. WDM 메트로 링망의 기본 MAC 프로토콜은 CSMA/CA(Carrier Sense Multiple Access with Collision Avoidance)이며, 패킷을 빈 슬롯에 전송하고 송신지에서 패킷을 제거하는 SS (Source-Stripping) 기반으로 운용된다. 본 논문에서는 SS 방식으로 생성된 빈 슬롯을 바로 패킷 전송에 이용하는 방식과 그렇지 않은 방식을 각각 1-Persistent와 non-Persistent로 분류하고 MAC 프로토콜을 분석하여 기존 방식의 장 단점을 비교한다. 또한 전송 공정성과 처리율을 같이 고려하여 적용할 수 있는 확률 기반 p-Persistent MAC 프로토콜도 분석하였으며 시뮬레이션을 통하여 각 프로토콜을 노드 처리율, 전송 지연, 패킷 손실률, 전송 공정성 관점에서 비교하고 평가한다.y 수행을 여러 서버로 분산처리하게 함으로써 성능에 대한 신뢰성을 향상 시킬 수 있는 Load Balancing System을 제안한다.할 때 가장 효과적인 라우팅 프로토콜이라고 할 수 있다.iRNA 상의 의존관계를 분석할 수 있었다.수안보 등 지역에서 나타난다 이러한 이상대 주변에는 대개 온천이 발달되어 있었거나 새로 개발되어 있는 곳이다. 온천에 이용하고 있는 시추공의 자료는 배제하였으나 온천이응으로 직접적으로 영향을 받지 않은 시추공의 자료는 사용하였다 이러한 온천 주변 지역이라 하더라도 실제는 온천의 pumping 으로 인한 대류현상으로 주변 일대의 온도를 올려놓았기 때문에 비교적 높은 지열류량 값을 보인다. 한편 한반도 남동부 일대는 이번 추가된 자료에 의해 새로운 지열류량 분포 변화가 나타났다 강원 북부 오색온천지역 부근에서 높은 지열류량 분포를 보이며 또한 우리나라 대단층 중의 하나인 양산단층과 같은 방향으로 발달한 밀양단층, 모량단층, 동래단층 등 주변부로 NNE-SSW 방향의 지열류량 이상대가 발달한다. 이것으로 볼 때 지열류량은 지질구조와 무관하지 않음을 파악할 수 있다. 특히 이러한 단층대 주변은 지열수의 순환이 깊은 심도까지 가능하므로 이러한 대류현상으로 지표부근까지 높은 지온 전달이 되어 나타나는 것으로 판단된다.의 안정된 방사성표지효율을 보였다. $^{99m}Tc$-transferrin을 이용한 감염영상을 성공적으로 얻을 수 있었으며, $^{67}Ga$-citrate 영상과 비교하여 더 빠른 시간 안에 우수한 영상을 얻을 수 있었다. 그러므로 $^{99m}Tc$-transierrin이 감염 병소의 영상진단에 사용될 수 있을 것으로 기대된

  • PDF

A RFID-Based Multi-Robot Management System Available in Indoor Environments (실내 환경에서 운영 가능한 RFID 기반 멀티 로봇 관리 시스템)

  • An, Sang-Sun;Shin, Sung-Oog;Lee, Jeong-Oog;Baik, Doo-Kwon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.6
    • /
    • pp.13-24
    • /
    • 2008
  • The multi robot operation technique has emerged as one of the most important research subjects that focus on minimizing redundancy in space exploration and maximizing the efficiency of operation. For an efficient operation of the multi robot systems, the movement of each Single robot in the multi robot systems should be properly observed and controlled. This paper suggests Multi Robot Management System to minimize redundancy in space exploration by assigning exploration space to each robot efficiently to take advantage of the RFID. Also, this paper has suggested fault tolerance technique that detects disable Single robot and substitute it by activated Single robot in order to ensure overall exploration and improve efficiency of exploration. Proposed system overcomes previous fault that it is difficult for central server to detect exact position of robot by using RFID system and Home Robot. Designated Home robot manages each Single robot efficiently and assigns the best suited space to Single robot by using RFID Tag Information. Proposed multi robot management system uses RFID for space assignment, Localization and Mapping efficiently and not only maximizes the efficiency of operation, but also ensures reliability by supporting fault-tolerance, compared with Single robot system. Also, through simulation, this paper proves efficiency of spending time and redundancy rates between multi robot management applied by proposed system and not applied by proposed system.

  • PDF