• Title/Summary/Keyword: 시험 시공

Search Result 1,721, Processing Time 0.031 seconds

Lateral Earth Pressures and Displacements through Full Scaled Lateral Loading Test of Concrete Electric Pole Embedded in Ground (지중에 근입된 콘크리트전주의 실물 수평재하실험에 의한 수평토압과 변위특성)

  • Ahn, Tae-Bong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.4
    • /
    • pp.43-51
    • /
    • 2011
  • Many electric poles in the softground have been collapsed due to external load. In this study, 10 types of tests were performed with variation of location, numbers and depths of anchor blocks as well as depth of poles to find horizontal earth pressure through full scale pull-out tests. The horizontal earth pressure increased with embedded depth of electric pole, and earth pressure of lower passive zone decreased. The deeper of anchor block, earth pressure of passive zone becomes less. lateral displacements showed differences depending on location, numbers and depth of poles. The bending is generated in the upper part at the initial load, but it moved to central part as load increased. The maximum horizontal displacement decreased to 1/1.6 at -0.5m depth of anchor block and 1.3m additional laying depth of poles into ground.

Application of Grouting for Liquefaction Resistance Using Automatic Grouting System (그라우팅자동관리시스템을 이용한 액상화 방지 그라우팅의 적용)

  • Kong, Jinyoung;Kang, JunO;Cho, Hyunsoo;Kim, Jinchun;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.9
    • /
    • pp.79-87
    • /
    • 2011
  • This study conducted the research on the method of grouting quality management and the improvement effect by applying grouting construction's quality management technology to automatic injection management equipment through measure of liquefaction based on the case of reinforcement applying grouting at the region where liquefaction happened at section 12 site of highway construction. The pressure(p), speed(q), grouting penetration radius(R) value from injection pressure, injection speed, characteristics of grain size, and characteristics of viscosity through p-q-t chart analysis was applied to the automatic grouting system which could improve the quality management of grouting. Standard penetration test results after injection showed that N values represented 5-20 and the prevention of liquefaction became possible.

Water Purification Properties of Porous Zeolite Concrete (다공성 제올라이트 콘크리트의 수질정화 특성)

  • Choi, Min Ji;Sung, Nack Kook;Park, Sung Jae;Lee, Jung Ah;Yun, Hong Su;Hong, In Kwon
    • Applied Chemistry for Engineering
    • /
    • v.22 no.3
    • /
    • pp.332-335
    • /
    • 2011
  • As our interests in eco-friendly materials have been significantly increased, the utilization of porous zeolite concrete that has structural functionality and permeability has been increased. In this paper, the mixture of porous concrete and zeolite, which can be used as multirole boulders, was investigated for the suitability of an environment-friendly product by evaluating of the water purification ability. The contamination removal rates of BOD, TOC, T-N, and T-P in stagnant water tank were 70.6, 67.0, 57.7, and 50.6%, respectively. Also for the non-point source pollution with the inflow and the outflow, the removal rates of Zn, Pb, BOD, and COD were 99.9, 90.0, 69.2, and 33.5%, respectively. The performance of the heavy metal contamination removal for the porous zeolite showed better than that of stagnant system. Therefore, it is expected that the installation of the porous zeolite concrete can play a role as an eco-friendly products by its high contamination removal.

A Study on the Quality Control Method for Geotechnical Information Using AI (AI를 이용한 지반정보 품질관리 방안에 관한 연구)

  • Park, Ka-Hyun;Kim, Jongkwan;Lee, Seokhyung;Kim, Min-Ki;Lee, Kyung-Ryoon;Han, Jin-Tae
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.11
    • /
    • pp.87-95
    • /
    • 2022
  • The geotechnical information constructed in the National Geotechnical Information DB System has been extensively used in design, construction, underground safety management, and disaster assessment. However, it is necessary to refine the geotechnical information because it has nearly 300,000 established cases containing a lot of missing or incorrect information. This research proposes a method for automatic quality control of geotechnical information using a fully connected neural network. Significantly, the anomalies in geotechnical information were detected using a database combining the standard penetration test results and strata information of Seoul. Consequently, the misclassification rate for the verification data is confirmed as 5.4%. Overall, the studied algorithm is expected to detect outliers of geotechnical information effectively.

Characteristics of the floor impact sound by water to binder ratio of mortar (마감모르타르 물결합재비에 따른 바닥충격음 특성 변화)

  • Lee, Won-Hak;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.671-677
    • /
    • 2021
  • The present study aims to investigate the influence of the water to binder ratio of finishing mortar on the floor impact sound of apartments. For this, same resilient materials Expanded Polystyrene (EPS) with constant dynamic stiffness and different mortar layers with 52 %, 66 % and 72 % water to binder ratio respectively were used to build floating floor structures on which floor impact sounds were measured in standard testing facilities. As a result, it was found that light-weight floor impact sound was transmitted well when the water to binder ratio was 52% due to the high density. In case of heavy-weight floor impact sounds, since water to binder ratio of finishing mortar becomes higher as the weight of upper layer of resilient material lighter, it was shown that the natural frequency of floating floor structure moves to 63 Hz bandwidth which eventually cause a higher sound pressure level of floor impact sound. Thus, effect of water to binder ratio of mortar on the heavy-weight floor impact sounds was investigated.

Assessment of Rockmass Damage around a Tunnel Using P Wave Velocity Tomography (P파 속도 토모그래피를 이용한 터널 주변의 암반손상 평가)

  • Park, Chul-Soo;SaGong, Myung;Mok, Young-Jin;Kim, Dae-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.11
    • /
    • pp.53-60
    • /
    • 2009
  • Construction of a tunnel induces rock masses damage around the tunnel. The degree of damage produced on rock masses will affect on the mechanical and hydraulic behaviors of the rock masses. In this paper, P wave velocity measured by cross-hole test was used to assess rock masses damage around the test tunnel. Initiation of source signal was carried out using mechanical impact at the source installed borehole. In consequence, the generated P wave signal was low noise and apparent wave form, which allows accurate pick-up of first arrival time. From the test, the region where rock damage is expected shows relatively low P wave velocity. In addition, with multiple points of P wave velocity measurement along each cross-hole, two dimensional P wave tomography was obtained. The tomography provides apparent view of the rock damage behind the tunnel. The measured P wave velocity was correlated with features of rock masses, porosity and Q value.

Deformation Analysis of Shallow Tunnel Using Tunnel Model Test and Computational Analysis (모형시험과 수치해석을 이용한 저토피 터널의 변형거동에 관한 연구)

  • Lee, Jae-Ho;Kim, Young-Su;Moon, Hong-Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.1
    • /
    • pp.61-70
    • /
    • 2008
  • The control and prediction of surface settlement, gradient and ground displacement are the main factors in shallow tunnel design and construction in urban area. For deformation analysis of shallow tunnel due to excavation it is important to identify possible deformation mechanism of shear bands developing from tunnel shoulder to the ground surface. This paper investigaties quantitatively the deformation behavior of shallow tunneling by model tunnel test and strain softening analysis Incorporating the reduction of shear stiffness and strength parameters. The comparison of model tunnel test result and numerical simulation using strain softening analysis showed good agreement in crown settlement, normalized subsidence settlement and developing shear bands above tunnel shoulder. In this study, it is blown that the strain softening modeling is applicable to the nonlinear deformation analysis of shallow tunnel.

Estimating Maximum Past Pressures for Dredged and Reclaimed Ground (준설매립지반의 선행압밀하중 산정)

  • Baek, Won-Jin;Lee, Song;Jeong, Yong-Eun;Noh, Tae-Gil;Yang, Tae-Seon;Kim, Ju-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.8
    • /
    • pp.61-79
    • /
    • 2008
  • Consolidation settlements on marine dredged clays are often greatly and potentially damaging to structures. Currently, large-scale projects are in planning or progressing in Korea. These projects have been performed on thick and soft clay layers. So, the evaluation of consolidation characteristics for dredged and reclaimed ground is very important in design and construction. Therefore, in this study, a series of conventional consolidation tests were performed to investigate the consolidation characteristics of marine dredged clays near Gwang-yang Port. Preconsolidation pressures were evaluated by applying previously proposed 8 methods for the conventional tests results in order to evaluate the legitimacy of these methods. In these methods, when estimating maximum past pressures for dredged and reclaimed ground, it was proved that Becker (1987), Silva (1970), Sridharan (1991)'s methods are excellent in legitimacy.

A Study on Shell Foundation Behaviour in Cohesionless Soil (사질토 지반에서 Shell 기초 거동에 대한 연구)

  • Kim, Sang-Hwan;Jung, Yong-Su;Ko, Dong-Pil;Kang, So-Ra
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.7
    • /
    • pp.51-60
    • /
    • 2008
  • In this paper, the behaviour of shell foundation was studied. In the theoretical program, the general shallow foundation theories and failure mechanism developed by Terzaghi, Mayerhof and others were reviewed and compared. In the numerical study, the 2 and 3 dimensional FEM simulations were carried out using an uncoupled-analysis approach. The results obtained from the model test show that the bearing capacity of shell foundation was about 25% to 30% larger than that of general foundation. Due to the cases of shell angle, the maximum bearing capacity of shell foundation shows when the shell angle of foundation was $60^{\circ}$. In addition, even if the shell foundation has various advantages compared with the general foundations as described above, the practical verifications in full scale size will be necessary to use in the field and will be helpful in the technical development of other special foundations.

Applicability of CPT-based Toe Bearing Capacity of PHC Driven Piles (PHC 항타말뚝에 대한 CPT 선단 지지력 산정식의 적용성)

  • Le, Chi Hung;Chung, Sung-Gyo;Kim, Sung-Ryul
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.12
    • /
    • pp.107-118
    • /
    • 2009
  • As CPT penetration tends to show a similar behavior to that of pile driving, a number of methods for estimating the toe bearing capacity of piles based on CPT data have been proposed. To evaluate the applicability of the methods in this country, a total of 172 dynamic load tests data on PHC piles and 82 CPT data at a site in the Nakdong River estuary were collected. A specific four-step procedure was adopted for the selection of the reliable data, and statistical techniques were then applied to the analysis of the applicability. The results indicated that among a total of 10 CPT-based methods applied, the best one is the Aoki method (1975), followed by the LCPC (1982), ICP (2005) methods and others.