• Title/Summary/Keyword: 시험유역

Search Result 411, Processing Time 0.031 seconds

Characteristics of Runoff and Groundwater Quality from a Pasture and Field (방목지와 초지의 지표수 및 지하수 수질 특성)

  • Choe, Jung-Dae;Choe, Ye-Hwan;Kim, Gi-Seong
    • Water for future
    • /
    • v.28 no.3
    • /
    • pp.175-186
    • /
    • 1995
  • Characteristics of runoff and groundwater qualities from a pasture and field were investigated. Flumes and monitoring wells were installed and water qualities of $NO_3$-N, TP and TKN were monitored from Aug. 1993 to Aug. 1994. Runoff from the pasture which was a sandy soil with cobbles mostly formed with seeping water at the bottom of it. But once overland flow occurred because of heavy rainfall, runoff increased sharply. $NO_3$-N concentration in pasture runoff was relatively stable ranging between 0.241-3.962mg/l. TP and TKN concentrations were stable but sharply increased once overland flow occurred. $NO_3$-N concentration in pasture groundwater was relatively stable regardless of depth of monitoring wells but TP and TKN concentrations were smaller in deeper wells. Runoff from the field which was flat and covered well with Sudan grass and surface residue was relatively small and $NO_3$-N, TP and TKN concentrations in runoff were stable and seemed unaffected by flow rate. $NO_3$-N concentration in field groundwater increased at the rate of 2.2mg/l per 100 m during a growing season as groundwater flows through the field. No significant differences in TP and TKN concentrations between the upper and lower areas in field groundwater were detected.

  • PDF

Characteristics of Non-Point Pollutants from Forest Landuse (산림 지역의 비점오염물질 유출 특성)

  • Kim, Ji-Yeon;Kim, Jee-Hyun;Jung, Min-Kyoung;Ji, Yong-Dea;Hwang, Jae-Yup;Park, Soo-Young;Yu, Jay-Jung;Kim, Tae-Seung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.287-287
    • /
    • 2011
  • 모니터링 자료의 부족으로 인하여 다양한 토지이용에서 발생하는 비점오염물질의 관리에 어려움을 겪고 있는 실정이다. 현재 환경부에서는 현행 토지계의 원단위를 세부적으로 분류하여 재산정하기 위하여 지목별로 장기 모니터링이 수행되고 있다. 특히, 산림 지역의 경우 도시 및 축산지역에 비하여 강우유출수의 농도는 낮더라도 유량적인 측면에 보았을 때 전체 수계에 대한 부하량 기여도는 매우 높다고 볼 수 있다. 따라서 본 연구는 장기모니터링의 일환으로 산림지역에 대한 비점오염물질 유출 특성을 파악하기 위하여 모니터링 및 분석을 실시하였으며, 이러한 결과는 향후 비점오염원 평가기반을 마련하고자 한다. 본 연구는 활엽수지역을 대상으로 2010년 4월부터 10월까지 총 16회에 걸쳐 모니터링이 수행되었으며, 시료의 성분 변화를 막기 위해 냉장기능이 있는 자동채수기를 이용하여 시료를 채취하였다. 수질분석항목은 BOD, COD, DOC, SS, T-N, $NO_3$-N, $NH_3$-N, T-P, $PO_4$-P로 총 9가지 항목을 분석하였다. 강우사상에 대한 모니터링 결과, 총강우량은 7.0~76.5mm, 강우지속시간은 1~30hr, 평균 강우강도는 0.88~18.50mm/hr의 범위를 보이고 있으며, EMC(Event Mean Concentration, 유량가중평균농도)결과 BOD는 0.4~2.4mg/L, T-N은 1.156~14.777mg/L, T-P는 0.009~0.562mg/L인 것으로 나타났으며, SS는 1.8~71.9mg/L 로 비교적 높은 값을 나타내는 것으로 분석되었다. 농도 변화 및 유출경향의 패턴을 볼 때, 유량이 증가함에 따라 농도도 점점 증가하여 첨두유량이 발생된 후 감소하는 경향을 나타내는 것으로 분석되었다. 또한 우리나라의 경우, 시험유역을 대개 산지 소유역에 설치하는 경우가 많아서 일반적으로 지연시간이 짧은 경우가 많기 때문에 이 지역 역시 강우가 내린 후 계류유출량의 증가에 영향을 주는 강우의 유출속도는 비교적 빠른 것으로 나타났다. 그리고 단기 수문곡선상에서 강우량이 많을 시 유출이 빠르게 일어나 첨두 유량에 도달하는 시간이 짧고, 강우량이 적을 시에는 첨두 유량의 출현시간이 늦어지는 것을 볼 수 있었다.

  • PDF

Analysis of Hydraulic effects on Piers and Transverse Overflow Type Structures in Urban Stream (도시하천의 교각 및 횡단 월류형 구조물에 의한 수리영향 분석)

  • Yoon, Sun-Kwon;Chun, Si-Young;Kim, Jong-Suk;Moon, Young-Il
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.2
    • /
    • pp.197-212
    • /
    • 2008
  • Recently, stream flow analysis has been accomplished by one or two dimensional equations and was applied by simple momentum equations and fixed energy conservations which contain many condition limits. In this study, FLOW-3D using CFD (Computational Fluid Dynamics) was applied to stream flow analysis which can solve three dimensional RANS (Reynolds Averaged Navier-Stokes Equation) control equation to find out physical behaviors and the effect of hydraulic structures. Numerical simulation accomplished those results was compared by using turbulence models such as ${\kappa}-{\varepsilon}$, RNG (Renormalized Group) ${\kappa}-{\varepsilon}$ and LES (Large Eddy Simulation). Numerical analysis results have been illustrated by the turbulence energy effects, velocity of flow, water level pressure and eddy flows around the piers and transverse overflow type structures. These results will be able to used by basis data that catch hold of effects on long-term bed elevation changes, sediment accumulations, scours and water aggravations by removal of obsolete transverse over flow type structures in urban stream.

Selection of Irrigation Structures which Effected by Wastewater by GIS (하수처리수에 영향을 받는 관개용 수리시설 선정과 GIS 자료구축)

  • Kim, Hae-Do;Lee, Kwang-Ya;Chung, Kwang-Kun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.273-277
    • /
    • 2007
  • 하수처리장 현황은 2005년을 기준으로 271개소이며 2006년에는 23개소(526.1천톤/일)가 완공되어 총 294개소(22백만톤/일)의 하수처리장이 운영중에 있다. 또한 2006년내에 완공예정인 처리장은 68개소(693.5천톤/일)로서 2007년도에는 총 362개소(23,087천톤/일)로 예상하고 있다. 하수처리수를 년간으로 환산하면 약 84억톤 정도이며 이는 전체 수자원이용량 331억톤의 25%에 해당하는 수치이며, 농업용수이용량인 158억톤의 53%를 차지하는 규모이다. 이처럼 매년 $5{\sim}7%$씩 하수처리수가 늘어나고 있으며 더욱이 대부분 기존의 관개용 수리시설에 인접하여 방류되어 직 간접적으로 재이용되고 있는 실정이다. 본 연구에서는 기존 농업기반시설에 인접한 하수처리수가 얼마큼 농업에 영향을 주고 있는지를 파악하기 위해 GIS 기법을 이용하여 하수처리장으로부터 일정한 거리에 인접하거나 방류지점 하류에 위치한 관개용 수리시설을 찾아내어 재이용 관리지역으로 선정하였고 현장조사를 실시하여 재이용정보를 DB로 구축하였다. 연구결과 전국 271개소 하수처리장중 관개용 수리시설보다 상류측에 있으면서 반경 1.5km 이내에 위치한 하수처리장은 127개소로 나타났으며 현장조사결과 많은 지역에서 하수처리수를 농업용으로 직접 또는 간접적으로 이용하고 있었다. 이처럼 주변상황으로 인해 하수처리수를 농촌용수로 이용할 수밖에 없는 지역이 발생하고 있고 앞으로도 하수처리장이 계속 증설되고 있는 한 기존의 농업수리시설물은 하수처리수의 영향이 더욱 커질 것으로 판단되므로 하수처리장 주변의 농업기반시설에 대한 지속적인 관리가 필요하다.의(2005년 10월 19일)에서는 농업용수 10% 절약 대책과 유역단위의 통합적 물 관리를 요구하게 되었다. 우리나라는 현실적으로 매년 홍수 피해가 발생하고 있지만, 다른 한편 인구밀도가 높고 1인당 가용 수자원이 상대적으로 적기 때문에 국지적 물 부족 문제를 경험하고 있다. 최근 국제적으로도 농업용수의 물 낭비 최소화와 절약 노력 및 타 분야 물 수요 증대에 대한 대응 능력 제고가 매우 중요한 과제로 부각되고 있다. 2006년 3월 멕시코에서 개최된 제4차 세계 물 포럼에서 국제 강 네트워크는 "세계 물 위기의 주범은 농경지", "농민들은 모든 물 위기 논의에서 핵심"이라고 주장하고, 전 프랑스 총리 미셀 로카르는 "...관개시설에 큰 문제점이 있고 덜 조방적 농업을 하도록 농민들을 설득해야 한다. 이는 전체 농경법을 바꾸는 문제..."(segye.com, 2006. 3. 19)라고 주장하는 등 세계 물 문제 해결을 위해서는 농업용수의 효율적 이용 관리가 중요함을 강조하였다. 본 연구는 이러한 국내외 여건 및 정책 환경 변화에 적극적으로 대처하고 물 분쟁에 따른 갈등해소 전략 수립과 효율적인 물 배분 및 이용을 위한 기초연구로서 농업용수 수리권과 관련된 법 및 제도를 분석하였다.. 삼요소의 시용 시험결과 그 적량은 10a당 질소 10kg, 인산 5kg, 및 가리 6kg 정도였으며 질소는 8kg 이상의 경우에는 분시할수록 비효가 높았으며 특히 벼의 후기 중점시비에 의하여 1수영화수와 결실율의 증대가 크게 이루어졌다. 3. 파종기와 파종량에 관한 시험결과는 공시품종선단의 파종적기는 4월 25일부터 5월 10일경까지 인데 이 기간중 일찍 파종하는 경우에 파종적

  • PDF

Sensitivity Analysis of the MUSIC Model Parameters (MUSIC모형의 매개변수에 관한 민감도 분석)

  • Im, Jang-Hyuk;Yeoun, Ji-Woong;Park, Sung-Sik;Song, Jai-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.236-240
    • /
    • 2007
  • 최근 집중호우에 의한 피해가 증가함에 따라 도시화에 따른 불투수 면적이 유출량 증가의 주요한 원인으로 지목되고 있으며 도시의 인구집중으로 인한 지하수의 난개발로 지하수 오염 및 고갈이 빠르게 진행되고 있다. 이에 도시의 지속적이고 건전한 물 관리를 위하여 우수유출저감시설이 고려되고 있으며, 정량적인 저감효과의 분석방법이 요구되고 있다. 따라서, 본 연구에서는 호주에서 물관리 및 우수유출저감을 고려한 도시유역계획을 위해 이용되고 있는 모형에 대한 민감도 분석을 실시하였으며, 이러한 결과를 바탕으로 MUSIC 향후 국내 우수유출저감시설에 관한 수문 해석시 MUSIC의 적용이 가능할 것으로 판단된다. MUSIC의 매개변수 중 불투수율과 토양특성이 매우 중요한 매개변수로 고려되고 있으므로, 본 연구에서는 투수지역의 최대저류깊이, Soil storage(mm), 강우초기 최대저류깊이의 포화정도 Initial storage(%), 지하수위에 도달할 수 있는 Field capacity(mm), 최대 침투율에 영향을 미치는 건조토양상태의 침투율을 정의하는 계수 a와 함수비 증가에 따른 최대 침투율 감소를 정의하는 지수 b 등의 매개변수에 대해 초기값을 중심으로 일정비율로 각 매개변수를 10단계로 구분하여 민감도 분석을 실시하였다. 주요 매개변수의 민감도 분석 결과로부터 MUSIC의 모의를 위해서는 불투수율의 민감도 변화 범위가 가장 넓고 첨두유출량과 총유출량 변화가 함께 일어나므로, 이를 가장 우선적으로 조정하고 이와 함께 토양특성을 반영하는 Soil storage와 Initial storage를 고려한다면 MUSIC을 이용하여 개발에 의한 유출변화와 다양한 우수침투시설 설치에 따른 저감효과를 합리적으로 예측할 수 있을 것으로 판단된다. 물 관리를 요구하게 되었다. 우리나라는 현실적으로 매년 홍수 피해가 발생하고 있지만, 다른 한편 인구밀도가 높고 1인당 가용 수자원이 상대적으로 적기 때문에 국지적 물 부족 문제를 경험하고 있다. 최근 국제적으로도 농업용수의 물 낭비 최소화와 절약 노력 및 타 분야 물 수요 증대에 대한 대응 능력 제고가 매우 중요한 과제로 부각되고 있다. 2006년 3월 멕시코에서 개최된 제4차 세계 물 포럼에서 국제 강 네트워크는 "세계 물 위기의 주범은 농경지", "농민들은 모든 물 위기 논의에서 핵심"이라고 주장하고, 전 프랑스 총리 미셀 로카르는 "...관개시설에 큰 문제점이 있고 덜 조방적 농업을 하도록 농민들을 설득해야 한다. 이는 전체 농경법을 바꾸는 문제..."(segye.com, 2006. 3. 19)라고 주장하는 등 세계 물 문제 해결을 위해서는 농업용수의 효율적 이용 관리가 중요함을 강조하였다. 본 연구는 이러한 국내외 여건 및 정책 환경 변화에 적극적으로 대처하고 물 분쟁에 따른 갈등해소 전략 수립과 효율적인 물 배분 및 이용을 위한 기초연구로서 농업용수 수리권과 관련된 법 및 제도를 분석하였다.. 삼요소의 시용 시험결과 그 적량은 10a당 질소 10kg, 인산 5kg, 및 가리 6kg 정도였으며 질소는 8kg 이상의 경우에는 분시할수록 비효가 높았으며 특히 벼의 후기 중점시비에 의하여 1수영화수와 결실율의 증대가 크게 이루어졌다. 3. 파종기와 파종량에 관한 시험결과는 공시품종선단의 파종적기는 4월 25일부터 5월 10일경까지 인데 이 기간중 일찍 파종하는 경우에 파종적량은 10a당 약 8${\ell}$이고 늦은 경우에는 12${\ell}$ 정도였다. 여기서 늦게 파종한 경우 감수의 가장

  • PDF

Developing an On-Line Monitoring System for a Forest Hydrological Environment - Development of Hardware - (산림수문환경(山林水文環境) 모니터링을 위(爲)한 원거리(遠距離) 자동관측(自動觀測)시스템의 개발(開發) - 하드웨어를 중심(中心)으로 -)

  • Lee, Heon Ho;Suk, Soo Il
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.3
    • /
    • pp.405-413
    • /
    • 2000
  • This study was conducted to develop an on-line monitoring system for a forest hydrological environment and its meteorological condition, such as temperature, wind direction and speed, rainfall and water level on V-notch, electrical conductivity(EC), potential of hydrogen(PH) by the motor drive sensor unit and measurement with a single-chip microprocessor as controller. These results are summarized as follows ; 1. The monitoring system consists of a signal process unit, motor drive sensor unit, radio modem unit and power supply. 2. The motor drive sensor unit protects the sensor from swift current or freezing and can constantly maintain fixed water level during measurements. 3. This monitoring system can transfer the data by radio modem. Additionally, this system can monitor hydrological conditions in real time. 4. The hardware was made of several modules with an independent CPU. They can be mounted, removed, repaired and added to. Their function can be changed and expanded. 5. These are the result of an accuracy test, the values of temperature, EC and pH measured within an error range of ${\pm}0.2^{\circ}C$, ${\pm}1{\mu}S$ and ${\pm}0.1pH$ respectively. 6. This monitoring system proved to be able to measure various factors for a forest hydrological environment in various experimental stations.

  • PDF

A Comparative Study on Direct Instrument Methods in Open Channel for Measuring River Water Usage (하천수 사용량 계측을 위한 개수로에서의 직접 계측방법 비교 연구)

  • Baek, Jongseok;Kim, Chiyoung;Lee, Kisung;Kang, Hyunwoong;Song, Jaehyun
    • Journal of Korean Society of Disaster and Security
    • /
    • v.13 no.4
    • /
    • pp.65-74
    • /
    • 2020
  • Continuous and accurate instrument of river water usage is needed for sustainable river water management. Although the instrument methods applicable to each point of use of river water are different, more precise direct instrument methods are required at the point of major open channel. Users of river water should select appropriate direct instrument methods to measure usage, but there is a lack of standards and verification research. In this study, the H-Q rating curve method, ultrasonic method, and microwave method were applied directly to the test basin in the upper basin of Mangyeong river, and the accuracy of measurement data was evaluated by comparing absolute error between discharge data calculated by instrument method. When comparing the calculated discharge of point units, the ultrasonic method showed the best results of the actual measurement. Through continuous instrument, the sum of the daily and monthly units was compared, and the ultrasonic and microwave methods were shown to be highly accurate. Based on the results of this study, it is hoped that the appropriate direct measurement method can be selected according to the importance of the river water use facility, considering that the ultrasonic method and the microwave method are relatively costly compared to the water level-flow relationship method.

Unconfined Compressive Strength of Fiber-reinforced Cemented Sands by Fiber Reinforcement Form (섬유의 보강 형태에 따른 섬유-시멘트 혼합토의 일축압축강도특성)

  • Park, Sung-Sik;Kim, Young-Su;Lee, Jong-Cheon
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.8
    • /
    • pp.159-169
    • /
    • 2007
  • The behavior of fiber-reinforced cemented sands (FRCS) was studied to improve a brittle failure mode observed in cemented sands. Nak-dong River sand was mixed with ordinary Portland cement and a Polyvinyl alcohol (PVA) fiber. A PVA fiber is widely used in concrete and cement reinforcement. It has a good adhesive property to cement and a specific gravity of 1.3. A PVA fiber has a diameter of 0.1 mm that is thicker than general PVA fiber for reinforced cement. Clean Nak-dong River sand, cement and fiber at optimum water content were compacted in 5 layers giving 55 blows per layer. They were cured for 7 days. Cemented sands with a cement/sand ratio of 4% were fiber-reinforced at different locations and tested for unconfined compression tests. The effect of fiber reinforcement form and distribution on strength was investigated. A specimen with evenly distributed fiber showed two times more strength than not-evenly reinforced specimen. The strength of fiber-reinforced cemented sands increases as fiber reinforcement ratio increases. A fully reinforced specimen was 1.5 times stronger than a specimen reinforced at only middle part. FRCS behavior was controlled not only by a dosage of fiber but also by fiber distribution methods or fiber types.

Introduction of a New Method for Total Organic Carbon and Total Nitrogen Stable Isotope Analysis of Dissolved Organic Matter in Aquatic Environments (수환경 내 용존성 유기물질의 총 유기탄소 및 총 질소 안정동위원소 신규 분석법 소개)

  • Si-yeong Park;Heeju Choi;Seoyeon Hong;Bo Ra Lim;Seoyeong Choi;Eun-Mi Kim;Yujeong Huh;Soohyung Lee;Min-Seob Kim
    • Korean Journal of Ecology and Environment
    • /
    • v.56 no.4
    • /
    • pp.339-347
    • /
    • 2023
  • Dissolved organic matter (DOM) is a key component in the biogeochemical cycling in freshwater ecosystem. However, it has been rarely explored, particularly complex river watershed dominated by natural and anthropogenic sources, such as various effluent facility and livestock. The current research developed a new analytical method for TOC/TN (Total Organic Carbon/Total Nitrogen) stable isotope ratio, and distinguish DOM source using stable isotope value (δ13C-DOC) and spectroscopic indices (fluorescence index [FI] and biological index [BIX]). The TOC/TN-IR/MS analytical system was optimized and precision and accuracy were secured using two international standards (IAEA-600 Caffein, IAEA-CH-6 Sucrose). As a result of controlling the instrumental conditions to enable TOC stable isotope analysis even in low-concentration environmental samples (<1 mgC L-1), the minimum detection limit was improved. The 12 potential DOM source were collected from watershed, which includes top-soils, groundwater, plant group (fallen leaves, riparian plants, suspended algae) and effluent group (pig and cow livestock, agricultural land, urban, industry facility, swine facility and wastewater treatment facilities). As a result of comparing characteristics between 12 sources using spectroscopic indices and δ13C-DOC values, it were divided into four groups according to their characteristics as a respective DOM sources. The current study established the TOC/TN stable isotope analyses system for the first time in Korea, and found that spectroscopic indices and δ13C-DOC are very useful tool to trace the origin of organic matter in the aquatic environments through library database.

Studies on the Overflow from Torrential Stream -A Case Study at the Samsung-cheon in Mt. Kwanak- (야계(野溪)의 월류발생(越流發生)에 관(關)한 연구(硏究) -관악산(冠岳山) 삼성천(三聖川)에서의 시험사례(試驗事例)-)

  • Woo, Bo Myeong;Kim, Kyong Ha;Jeong, Do Hyeon
    • Journal of Korean Society of Forest Science
    • /
    • v.77 no.3
    • /
    • pp.269-275
    • /
    • 1988
  • To investigate the cause of overflow in the torrential stream, the estimated peak flow of run-off and the maximum tarring capacity of the stream were measured at the upstream of Samsung-cheon located in Kwanak Aboretum during July, 1987. The results obtained from this study could be summarized as follows : 1. The surveyed catchment area was 477ha, which was 116 of the designed area (410ha) by the plan. 2. The maximum rainfall intensity measured was 99.5mm/hr and was almost same as the designed intensity(100mm/hr). 3. The surveyed run-off coefficient was 0.672 that was about twice as much as designed one(0.35). 4. The surveyed peak flow of run-off was $88.59m^3/sec$, 222% as large the designed one($39.9m^3/sec$). 5. The designed cross-sectional area of the stream was $17.25m^2$, which was 68% of the designed one$25.43m^2$. 6. The surveyed hydraulic mean radius was 0.94m, which was shorter than the designed one(1.28m). 7. The surveyed mean stream-bed gradient(0.998%) was almost the same as the designed one(1.00%). 8 The surveyed maximum velocity of flow passing through the stream was 2.87m/sec, 78.0 of the designed one(3.68m/sec). 9 The surveyed run-off capacity of the stream was $49.51m^3/sec$, 53% of the designed one ($93.5m^3/sec$).

  • PDF