• Title/Summary/Keyword: 시표 대비도

Search Result 8, Processing Time 0.02 seconds

Minimal Illumination to Identify the Chart in Each Visual Acuity and Deviation of Identification Capability According to Illumination and Chart Contrast (시력 단계별 시표 식별 최소조도 및 대비도와 조도에 따른 시표 식별능력의 차이)

  • Kim, Sang-Yeob;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.549-554
    • /
    • 2013
  • Purpose: To determine the minimal illumination for visual acuity with the decimal vision chart and individual difference with varying contrast and illumination. Methods: Landolt's vision chart with 10 different grade of contrast was made. Minimal illumination was measured for 69 eyes using 100% contrast vision chart. Minimal contrast for identifying the chart was measured in conditions of the minimal illumination and 230 lx, respectively. Results: Minimal illumination was gradually increased with decrease of the chart size. Mean of minimal illumination to identify the 1.0 visual acuity was $74.39{\pm}25.90$ lx with range of 17~107 lx. In conditions of the minimal illumination and 230 lx, the minimal contrast for identifying the chart were gradually increased with decrease of the chart size in both conditions, the those deviation for 69 eyes was also increased. Conclusions: For refractive correction, examiners need to consider the individual difference for identifying the visual chart according to illumination and contrast.

Change of Fixation Disparity and Accommodation when the Fusion Contrast Varied (융합대비에 따른 주시시차와 조절의 변화)

  • Seo, Jae-Myoung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: To study the change of fixation disparity and accommodation as fusion contrast is deteriorated. Methods: 16 subjects who had above 20/20 and stereopsis took part. Monocular and binocular refraction were done with Zeiss Polatest Classic whereas the critical angle for stereopsis was done with TNO. A computer programmed with Random-Dot stereogram and vernier test managed a precise change of the fusion contrast and exposure time. Results: The fixation disparity was influenced by reduction of fusion contrast and had tendancy to exophoria (p=0.0004), especially it is considerably higher when uncrossed disparity was shown to exophoric subjects. Although accommodation was not influenced by a change of fusion contrast (p=0.803), vernier acuity was influenced (p=0.0000). Conclusions: Exophoric trend arose as the fusion contrast was reduced, nevertheless there was no accommadative change.

  • PDF

Individual Difference in the Decrease of Visual Acuity and the Change in Contrast Threshold According to the Level of Optically Induced Retinal Defocus (광학적으로 유발된 망막흐림의 정도에 따른 시력감소의 개인차와 인식 대비도의 변화)

  • Kim, Sang-Yeob;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.93-98
    • /
    • 2014
  • Purpose: We were aim to investigate individual difference of visual acuity (VA) decrease and the change of contrast threshold (CT) according to the level of optically induced retinal defocus. Methods: A total of 69 eyes were examined using consist of ten-graded decimal vision chart (Landolt's ring). After conducted full correction of subject's refractive error, a monocular VA and CT were measured according to sequential increase by 0.25 D each time. Results: VA gradually decreased according to the increase of retinal defocus level. Individual difference of VA decrease was range from 1.2 to 0.6 in retinal defocus induced by +0.25 D. When retinal defocus was induced as much as +0.50 D and +0.75 D, it was in the range of 1.0 to 0.3 and 0.9 to 0.1 respectively. With +1.00 D, some participants didn't even recognize the 0.1 in the chart. With +1.75 D, whole participant did not recognize the 0.1. Also, CT was gradually decreased with increase of the retinal defocus level. Conclusions: Examiners should consider individual difference in the decrease of VA according to the level of residual refractive error when determining final prescription of a patient.

Change of Contrast Sensitivity According to Light Transmittance of Color Lens (색렌즈의 광투과율에 따른 대비감도 변화)

  • Lee, Sun-Haeng;Lee, Yoon-Jeong;Cho, Hyun-Gug
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.925-929
    • /
    • 2009
  • 본 연구는 착색렌즈의 광투과율에 따른 명소시 대비감도의 변화를 분석하여 색렌즈를 착용할 때 색상에 따른 적절한 광투과율 기준을 제시하고자 하였다. 정상 시기능을 가진 남자 24명과 여자 13명을 대상으로, 광투과율 80~90%, 60~80%, 43~60%, 30~43%로 착색된 4개의 색렌즈(회색, 갈색, 적색, 녹색)를 순서대로 착용시키고 F.A.C.T. 시표를 이용하여 대비감도 검사를 실시하였다. 검사 결과, 광투과율이 감소될수록 대비감도는 감소되었고, 시감도는 갈색이 가장 높은 것으로 나타났고, 반대로 적색이 가장 낮은 것으로 나타났다. 대비감도 검사결과를 고려한 색상별 권장 광투과율은 갈색, 회색과 녹색 38% 이상, 적색 52% 이상인 것으로 나타났다. 이러한 결과들로 보아 일상생활에서 눈을 보호할 목적으로 색렌즈를 선택할 때 색상과 그 색상에 적절한 광투과율이 고려되어야 한다.

  • PDF

The Study of Visual Fatigue by Monitor Letter Contrast with an Eye Tracker (아이트래커를 이용한 모니터 글자 대비도에 따른 눈의 피로도 연구)

  • Kim, Ha-Rim;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.533-538
    • /
    • 2014
  • Purpose: This study is to investigate correlation between eye fatigue and letter contrast according to letter contrast changes on monitor display. Methods: Reading speed test were carried out for 53 subjects (mean age: $22.68{\pm}1.85$ years) who have over Best-corrected visual acuity (BCVA) 1.0, and 45 subjects, who could read over 123 out of 163 letters among 53 subjects were selected. They were asked to read the letters which were composed of Black (contrast 100%), Dark gray (contrast 80%), Gray (contrast 80%), Light gray (contrast 30%) randomly. The change of their eye fatigue by letter contrast on monitor display was measured by monitoring their eyes with an eye-tracker while they were reading letters. Results: Event Duration (sec) was 33.635 for Black, 32.266 Dark gray, 33.936 for Gray, and 34.848 for Light gray. Average of Fixation Duration (sec) was 0.224 for Black, 0.218 for Dark gray, 0.239 for Gray and 0.243 for Light gray. Average of Pupil diameter (mm) was 41.133 mm for Black, 41.160 mm for Dark gray, 40.880 mm for Gray and 40.459 mm for Light gray. Frequency (blinks/sec) was 0.211 for Black, 0.206 for Dark gray, 0.221 for Gray, and 0.238 for Light gray. Conclusions: Event Duration and average of Fixation Duration were the shortest for Dark gray and the longest for Light gray. In average Pupil diameter was the biggest Dark gray and the smallest for Light gray. Blink Frequency (blinks/sec) was the lowest for Dark gray and the highest for Light gray. Visual fatigue by brightness of letters on monitor display was the least for Dark gray followed by Black, Gray and Light gray.

Changes of Contrast Sensitivity According to Light Transmittance of Color Lenses (색렌즈의 광투과율에 따른 대비감도 변화)

  • Lee, Sun-Haeng;Lee, Yoon-Jeong;Cho, Hyun-Gug
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3427-3433
    • /
    • 2009
  • This paper attempted to suggest the standards of light transmittance based on the analysis of the changes in contrast sensitivity of photopic condition according to the light transmittance of tinted lenses. The subjects of the experiment were 24 male and 13 female adults with normal ocular functions. They were asked to wear four tinted lenses (gray, brown, red, and green) in turn. The light transmittance of the lenses were 80~90%, 60~80%, 43~60%, and 30~43%, respectively. Contrast sensitivities were measured by using F.A.C.T. chart. The results showed that contrast sensitivities were decreased in proportion to the decrease of the light transmittance, and visual sensitivity of brown lenses were the highest and that of red lenses were the lowest. The results of the experiments suggested that the light transmittance should be over 38% for brown, gray and green lenses, and over 52% for red lenses. Accordingly the appropriate light transmittance should be considered when tinted lenses are selected for the purpose of eye protection in everyday life.

Changes of Contrast Sensitivity with Decreasing Luminance in Photopic Conditions (명소시 상태에서 휘도 감소에 따른 대비감도 변화)

  • Lee, Eun Jin;Yoon, Moon Joo;Kim, Soo-Hyun;Yang, Gye Tak;Jeong, Ju-Hyun;Kim, Hyun Jung;Kim, Hyun Il;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.411-417
    • /
    • 2012
  • Purpose: To investigate changes of contrast sensitivity with decreasing luminance in photopic conditions. Methods: Contrast sensitivities for 63 university students were investigated at 5 different luminance levels using FACT chart. Results: All contrast sensitivities measured were in the normal range. The peak of contrast sensitivity function was observed to move from 6 to 3 cpd between 40 and $10cd/m^2$. From an intersection point of two hypothetical lines related with contrast sensitivity for 6 and 3 cpd, we could evaluated that the peak moved from 6 to 3 cpd at about $25cd/m^2$. When luminance decreases from 120 to $10cd/m^2$, contrast sensitivity loss at 6 cpd was most, while contrast sensitivity at 1.5 cpd changed little. We could evaluate that at luminance of more than $25cd/m^2$ evaluated approximately, contrast sensitivity was high in the following order of spatial frequency: 18< 12<1.5<3<6 cpd, while at luminance of less than about $25cd/m^2$ as follows: 18<12<1.5<6<3 cpd. Contrast sensitivity losses with decreasing luminance were also evaluated using the decrements and decrement rates of contrast sensitivity. The decrement of contrast sensitivity was the greatest at 6 cpd, while the decrement rate was the greatest at 8 cpd. Conclusions: We propose that evaluation methods used in this research may be available as another methods to evaluate the changes of contrast sensitivity.

Comparison of Contrast Sensitivity at Near Between Functional Progressive Addition Lenses and Sigle Vision Lenses (기능성 누진가입도렌즈와 단초점렌즈의 근거리 대비감도 비교)

  • Kim, Chang-Jin;Kim, Hyun Jung;Kim, Jai Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.381-388
    • /
    • 2010
  • Purpose: This study was to compare the contrast sensitivity evaluated the visual ability at near wearing functional lenses for pre-presbyopes altered their single vision lenses to functional progressive addition lenses with low addition for 2 months. Methods: Healthy 32 subjects aged 24.03${\pm}$1.87 (male 23, female 9) who were recruited from university students wore functional progressive addition lenses(EYE-T, Chemilens Co., Korea, ADD 0.75D) for 2 months. Corrected visual acuity at distance and near and contrast sensitivity at near were tested right after wearing functional progressive addition lenses to compare wearing single vision lenses. And we had second test after 2 months later. Results: Comparing between test and retest, contrast sensitivity at near wearing functional progressive addition lenses was improved more than wearing single vision lenses at all spatial frequency of right, left and both eyes. Conclusions: There was considered that contrast sensitivity test is useful to evaluate the visual ability as well as quality of near work and can be applied variously.