• Title/Summary/Keyword: 시준

Search Result 83, Processing Time 0.024 seconds

A Study on Measurement Accuracy of Theodolite System(III) - A Measurement System Accuracy depending on a Distance of Scale Bar on the Distance 3 m between two Theodolites (데오드라이트 시스템의 측정 정확도에 대한 연구(III) - 시준거리 3 m에서 기준자 거리에 따른 측정 정도)

  • Yoon Yong Sik;Lee Dong Ju;Yoon In Jin
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.2
    • /
    • pp.48-54
    • /
    • 2005
  • The theodolite system consists of two theodolites, a scale bar and a target bu. A measurement accuracy of theodolite system is affected by a measurement distance of each equipment. This study was performed fir measuring an accuracy when the distance from theodolite to scale bar was changed 2~ 6 m on two theodolites distance 3 a The results showed thai the measurement accuracy could be $\pm$0.021 mm when the distance from theodolite to target was 2,3 and 6 n Specially, it was found that the maximum measurement accuracy was 10.017mm on theodolite collimation distance 3m and the distance 4 m of the theodolite and scale bar.

Improvement of Positioning Accuracy using Site Calibration and Monitoring System of GPS (GPS의 현장 Calibration과 Monitoring System을 이용한 위치결정 정확도 향상)

  • Ahn Won-Tae;Moon Young-Hyun;Choi Seok-Keun;Lee Jae-Kee
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2006.04a
    • /
    • pp.21-26
    • /
    • 2006
  • 기존 해상구조물의 위치결정은 조류나 바람, 안개, 비, 눈, 일조시간 등의 기상조건으로 인한 장해요인과 지상 기준점 좌표값을 쉽게 이용하기가 곤란하기 때문에 정확한 위치결정을 할 수 있는 기법이 필요하다. 기존의 측량방법은 해상의 가설측량대 설치 및 철거에 따른 시간과 예산이 소요되고, 기상조건에 따라 시준이 불가능하여 작업 중단과 공기가 지연되며, 시준오차와 자료 오기오차 등이 발생하는 문제점을 가지고 있다. 본 연구에서는 GPS측량방법을 이용하여 현장 Calibration을 수행하여 위치정확도를 향상시키고, 해상에서의 기상조건에 따른 문제점과 상시 Monitoring에 의한 자동제어시스템을 개발함으로써 측량 정확도 향상과 해상구조물 공사기간 단축, 공사비 절감 등의 효과를 가져 올 수 있도록 하였다.

  • PDF

Study on Measurement Accuracy by Auto-Collimation using Theodolite (데오드라이트를 이용한 자동 시준에 의한 측정 정확도에 관한 연구)

  • Lee Byoung-Gi;Kwon Jae-Wook;Yoon Yong-Sik
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1793-1796
    • /
    • 2005
  • The auto-collimation by using theodolite has been accomplished for the straight measurement and the horizontality adjustment. But according to the procedure of auto-collimation or composition of the measurement equipment, an error of the measurement can be occurred. Therefore, this paper accomplished the research for enhancement of measurement accuracy according to measurement procedure of auto-collimation. For that, it has been compared the study of the combination of several precise measurement equipment with using of several theodolite.

  • PDF

A Study on Measurement System Accuracy of Theodolite System(IV) - A Measurement System Accuracy depending on a Distance of Scale Bar on the Distance 4m between two Theodolites (데오드라이트 시스템의 측정 정확도에 대한 연구(IV) - 시준거리 4m에서의 기준자 거리에 따른 측정 정도)

  • Yoon Yong-Sik;Lee Dong-Ju;Park Yo-Chang
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.3
    • /
    • pp.67-73
    • /
    • 2005
  • An accuracy of theodolite system may be affected by a measurement environment and a measurement distance change from theodolite to scale bar and/or targets. This study was performed for measuring an accuracy when the distance from thodolite system to scale bar was changed $2\~6m$ on the distance 4m between two theodolites. The results showed that an accuracy was ${\pm}0.025mm$ or better when the distance from theodolite system to targets was 3, 4 and 5m. According to the results, it was found that the best distance from theodolite system to scale bar was $3\~4m$ when the collimation distance was $3\~4m$.

Measurement of Long Radius of Curvature by Using Bidirectional Shearing Interferometer (양방향 층밀리기 간섭계를 이용한 긴 곡률반경 측정)

  • 이윤우;조현무;이인원
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.198-203
    • /
    • 1994
  • An improved method for the measuement of very long radius of curvature by using a bidirectional shearing interferometer in a noncollimated light beam is given. This method can be used for both lenses and surfaces with positive or negative power. Detailed analyses for optical arrangements and achievable accuracy are presented.sented.

  • PDF

Micro lens system design for the optical fiber communication (광통신 변조기용 미세광학소자의 설계)

  • 홍경희
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.4
    • /
    • pp.217-221
    • /
    • 1992
  • A micro lens system was designed for the modulator in optical fiber communication. One was the collimating lens which transferred the diffracted beam from optical fiber to the modulator. The other was the coupling lens which connected the modulated collimating beam to the optical fiber. The light source was He-Ne laser beam. The lens would be made of optical glass BK-7. We determined the tolerance of curvature radius, thickness and conic constant.

  • PDF