• Title/Summary/Keyword: 시점확인

Search Result 1,683, Processing Time 0.032 seconds

Effect of Octreotide on Patients with Malignant Bowel Obstruction (악성장폐색 환자에서 Octreotide의 치료 효과)

  • Park, Ji-Chan;Jang, Yi-Sun;Jeon, Eun-Kyoung;Kim, Dong-Kyu;Lee, Wook-Hyun;Lee, Guk-Jin;You, Si-Young;Choi, Hyun-Ho;Park, Suk-Young
    • Journal of Hospice and Palliative Care
    • /
    • v.12 no.4
    • /
    • pp.194-198
    • /
    • 2009
  • Department of Internal Medicine, The Catholic University of Korea College of Medicine, Seoul, Korea Purpose: Malignant bowel obstruction causes gastrointestinal symptoms and leads to diminished quality of life in patients with advanced cancer. Several studies have shown the efficacy of octreotide for the relief of malignant bowel obstruction-related symptoms. The aim of this study is to assess the efficacy and safety of octreotide in patients with malignant bowel obstruction. Methods: We retrospectively reviewed medical records of twenty nine patients who had suffered from malignant bowel obstruction without clinical improvement of conservative care and subsequently, received octreotide treatment. Initial dosage of octreotide was 0.1 mg/day, and dose was escalated depending on the clinical effect. For each patient, we assessed visual analogue scale (VAS) of pain, number of vomiting episode, and amount of nasogastric tube drainage. Results: Median dosage of octreotide was 0.2 mg/day (range 0.1~0.6), and median duration from initial medication to death was 20 days (range 2~103). VAS before and after octreotide treatment were 5.6$\pm$1.24, and 2.7$\pm$0.96, respectively. The numbers of vomiting episode before and after octreotide treatment were 3.6/day$\pm$2.5, and 0.4/day$\pm$0.8, respectively. The mean amounts of nasogastric tube drainage before and after octreotide treatment were 975$\pm$1,083 cc/day and 115$\pm$196 cc/day, respectively. Statistically significant reduction in VAS, the number of vomiting episode and the amount of nasogastric tube drainage were observed after octreotide treatment (P<0.05). Conclusion: Administration of octreotide in patients with malignant bowel obstruction, which is uncontrolled by other medication, was effective and safe. In such clinical situations, physicians should consider to add of octreotide for symptomatic control.

  • PDF

End-of-Life Care Practice in Dying Patients with Do-Not-Resuscitate Order: A Single Center Experience (심폐소생술 금지 동의 후 사망한 환자의 현황과 연명의료 실태 조사: 단일 의료기관 경험)

  • Yoon, Sang Eun;Nam, Eun Mi;Lee, Soon Nam
    • Journal of Hospice and Palliative Care
    • /
    • v.21 no.2
    • /
    • pp.51-57
    • /
    • 2018
  • Purpose: End-of-life (EoL) decisions are challenging and multifaceted for patients and physicians. This study was aimed to explore how EoL care is practiced for patients with a do-not-resuscitate (DNR) order. Methods: We retrospectively analyzed medical records of patients who died after agreeing to a DNR order in 2016 at a university hospital. Characteristics including cause of death, intensity of EoL care, and other factors were reviewed and statistically analyzed. Results: Of total 375 patients, 170 patients (45.3%) died with malignancies, and 205 patients (54.6%) with other causes involving the central nervous system (19.2%), pulmonary (14.7%), cardiologic (6.7%) and infectious (6.4%) conditions. Both the cancer and non-cancer patient groups showed a short duration from DNR to death (median 3 days vs 2 days, P=0.629). An intensive care group comprising patients who received one or more intensive treatments such as ventilator (n=205) showed a higher number of non-cancer patients and a shorter duration from DNR to death than a group that withheld treatment before DNR (P<0.05). Conclusion: EoL decisions were made very late by both cancer and non-cancer patients. About half of the patients did not have cancer, and two-thirds of them decided DNR during intensive treatment. To make a good EoL decision, a shared decision making with patients should be done at an earlier stage.

Evaluation of Filtration and Backwash Efficiency of Non-point Source Pollution Reduction Facility (장치형 비점오염원 저감시설의 여과 및 역세 효율 평가)

  • Yun, Sangleen;Lee, Yong-Jae;Ahn, Jae-Hwan;Choi, Won-Suk;Lee, Jungwoo;Oh, Hye-Cheol;Kim, Seog-Ku
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.12
    • /
    • pp.664-671
    • /
    • 2017
  • Non-point source pollution is the emission source that unspecifically releases pollutants to water system from unspecific places such as cities, agricultural lands, mountains, and construction sites and its discharge path is not easily identified. Also, it is difficult to design and manage the reduction facilities for the emission quantity is primarily affected from weather conditions like rainfall. Since 2006, the significance of non-point source pollution reduction has been grown in Republic of Korea and this reinforces needs for the installation of reduction facilities. However, because the standards for the installation details and reduction efficiency are not clarified by law, people are preferring technologies that do not require particular maintenance and high expenses. The purpose of this study is to examine and maintain the efficiency of non-point source pollutants reduction facility which uses expended polypropylene as a media. The higher the depth of the media, the less range of variations in the reduction efficiency was observed and the final efficiency was also increased. When the media depth was 60 cm, the average reduction efficiency was 94% and 90% where linear velocities were 10 m/hr and 20 m/hr respectively. The results from 180 minutes operation in 10 m/hr and 20 m/hr of linear velocities were slightly different in head loss changes which were caused by media depth variations. The backwash experiments which were conducted in triplicate showed the reduction efficiency decreased as the time went on because of the media clogging. However, it was found that after the backwashing the reduction efficiency was increased as effective as the efficiency of the initial filtration.

Concentration Levels and Distribution Characteristics of Polycyclic Aromatic Hydrocarbons (PAHs) at Ambient Air in Industrial Complex Area (공단지역 대기 중 다환방향족탄화수소화합물(PAHs)의 농도수준 및 분포특성)

  • Jung, Jong-Hyeon;Phee, Young-Gyu;Cho, Sang-Won;Ok, Gon;Shon, Byung-Hyun;Lee, Kwan;Lim, Hyun-Sul
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.379-388
    • /
    • 2011
  • The purpose of this study was to investigate the concentration levels, distribution characteristics and blood concentration of Polycyclic Aromatic Hydrocarbons (PAHs) at ambient air in Industrial Complex Area. The samples were collected at 4 sites in Industrial Complex Area and its vicinities. The result indicated that there was the difference of PAHs concentration as followed local characteristics. The level of average concentration of PAHs in the air in Industrial Complex Area was $14.52{\sim}193.48ng/m^3$. The level of average concentration of six materials with possibility of cancer creation was $1.65{\sim}13.44ng/m^3$. The concentrations of PAHs were generally low, but Jechul-dong is considered an area where consistent monitoring of PAHs is required. In addition, benzo(a)pyrene was detected in every atmospheric sample, however the concentration was not high. The level of concentration of benzo(a)pyrene in the air in the Jechul-dong was $2.89ng/m^3$. But, the concentration of the PAHs in Jechul-dong showed that the Benzo(a)pyrene concentration is above $1ng/m^3$ of air quality standard(EU). The results of the concentration level of PAHs in the blood from 240 persons who were exposed directly were surveyed, it was $1.12{\sim}11.45ng/m^3$ for man and $1.20{\sim}26.89ng/m^3$ for woman. It was indicated that the difference between the genders was very little. The accumulation inside human was anticipated as the PAHs concentration in the blood for the aged was very high. Industrial Complex Area and its vicinities are an area which has been greatly influenced by PAHs and environmental contaminants. It is necessary to control the emission sources of PAHs and to construct an observation system at Industrial Complex Area from now on. It is time to reduce the risk factors for health and environmental disease to protect the health of resident in Industrial Complex Area and its vicinities.

Quality Characteristics of Topokki Garaedduk Added with Ginseng Powder (인삼분말을 첨가한 떡볶이용 가래떡의 품질특성)

  • Lee, Joon-Kyoung;Jeong, Jie-Hye;Lim, Jae-Kag
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.3
    • /
    • pp.426-434
    • /
    • 2011
  • In order to increase the use of rice, ginseng Garaedduks and Topokki were made and the physicochemical and sensory properties were investigated. Topokki and Garaedduks were added with 0, 1, 3 and 5% ginseng powder and stored at $20^{\circ}C$ for 48 hours. The moisture contents were not different to the increasing amount of ginseng powder and increasing storage time for 48 hours. The moisture content of Garaedduks for control and 5% added ginseng powder were 48.08% and 49.62%, respectively. The L value in color of uncooked ginseng Garaedduk decreased according to the added amount of ginseng powder, and the b value in color increased significantly according to the added amount of ginseng powder and during 48 hours storage at $20^{\circ}C$. Textural analysis, measured using a texture analyzer, of Garaedduk revealed that hardness, cohesiveness, chewiness decreased significantly and adhesiveness increased according to the added amount of ginseng powder. In sensory evaluation, 5% ginseng Garaedduk (uncooked, cooked) scored higher in overall acceptability than those of the other samples. In cooking properties, water absorption and solid contents increased according to the added amount of ginseng powder. Therefore, Garaedduk containing 5% ginseng powder was the most preferable. These results implied that the degree of retrogradation of ginseng Garaedduk might be low due to its high dietary fiber content.

Evaluation of Countermeasures Effectiveness in a Radioactively Contaminated Urban Area Using METRO-K : The Implementation of Scenarios Designed by the EMRAS II Urban Areas Working Group (METRO-K를 사용한 방사능으로 오염된 도시지역에서 대응행위효과 평가 : EMRAS II 도시오염평가분과 시나리오의 이행)

  • Hwang, Won-Tae;Jeong, Hae-Sun;Jeong, Hyo-Joon;Kim, Eun-Han;Han, Moon-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.3
    • /
    • pp.108-115
    • /
    • 2012
  • The Urban Areas Working Group within the EMRAS-2 ($\underline{E}$nvironmental $\underline{M}$odelling for $\underline{RA}$diation $\underline{S}$afety, Phase 2), which has been supported by the IAEA (International Atomic Energy Agency), has designed some types of accidental scenarios to test and improve the capabilities of models used for evaluation of radioactive contamination in urban areas. For the comparison of the results predicted from the different models, the absorbed doses in air were analyzed as a function of time following the accident with consideration of countermeasures to be taken. Two kinds of considerations were performed to find the dependency of the predicted results. One is the 'accidental season', i.e. summer and winter, in which an event of radioactive contamination takes place in a specified urban area. Likewise, the 'rainfall intensity' on the day of an event was also considered with the option of 1) no rain, 2) light rain, and 3) heavy rain. The results predicted using a domestic model of METRO-K have been submitted to the Urban Areas Working Group for the intercomparison with those of other models. In this study, as a part of these results using METRO-K, the countermeasures effectiveness in terms of dose reduction was analyzed and presented for the ground floor of a 24-story business building in a specified urban area. As a result, it was found that the countermeasures effectiveness is distinctly dependent on the rainfall intensity on the day of an event, and season when an event takes place. It is related to the different deposition amount of the radionuclides to the surfaces and different behavior on the surfaces following a deposition, and different effectiveness from countermeasures. In conclusion, a selection of appropriate countermeasures with consideration of various environmental conditions may be important to minimize and optimize the socio-economic costs as well as radiation-induced health detriments.

A Study on the Legal Aspects of International Express Courier Business (현행 항공법상 상업서류 송달업의 문제점과 입법방향)

  • Lee, Chang-Jae
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.26 no.2
    • /
    • pp.125-147
    • /
    • 2011
  • Considering a trend of logistics and transport industry in these days, it can be said that international express courier service is one of the most familiar transport type to the general public. Especially in Korea, due to development of electronic commercial transaction and the popularity of television home shopping, it can easily anticipated that express courier business will continuously grown in the future. However, the legal basis for international express courier is not properly set up so far. The only clause about this can be found on Korean Aviation Law said as 'commercial documents delivery business'. The origin of the commercial documents delivery business in Aviation Law is to make exception from public postal services which has been exclusive status as monopoly based on the Korean Postal Law. Basically, according to this regulation, all the private postal delivery is prohibited except some sort of commercial documents such as consignment notes, packing list, invoice etc. Thus, those documents could be delivered not only by public postal services but also by private courier company according to the Korean Postal Law. This waiver has probably come from under developing condition of Korean postal circumstances, however it should be revised according to the modernized business practice. Reflecting these revisions, the articles of Korean Postal Law adopted 'international express courier document' as the exception of postal service. Therefore, Korean Aviation Law also needs to be revised as Postal Law in due course. In addition to revision of Korean Aviation Law, some sort of new legislation is required to govern the private legal aspects such as legal liabilities, duties and rights of each parties on international express courier. This should be governed by 'law' not by 'terms and conditions' provided by business operators. Furthermore, to support and develop the current domestic logistics companies as international express courier company, it is required to regulate with the separate express courier law.

  • PDF

Comparison of Service Quality between Local and Global Coffee Brand Shops (국내와 국외브랜드 커피전문점의 서비스품질 비교)

  • Ryu, Si-Hyun;Lee, Ju-Young;Kim, Dong-Gun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.8
    • /
    • pp.1164-1171
    • /
    • 2011
  • The purpose of this study was to compare service quality between local and global coffee brand shops and to investigate improvement. Of 350 questionnaires distributed to customers of six brand coffee shops (three local brands, three global brands) located in Daejeon, 330 complete questionnaires (94.3%) were analyzed. The questionnaire included a seven-point multiple-item scale for measuring service quality. The 21 items measuring service quality were grouped into four factors, and the mean scores for the levels of "representativeness", "coffee sensory and beverage features", "employee attitude" and "physical environment" were 5.42, 4.77, 4.74, and 4.13, respectively. The levels of "coffee sensory and beverage features" and "employee attitude" of the high income customers were significantly lower than those of the low income customers. The results showed that the levels of "employee attitude" of local coffee brand shops was significantly higher (p=0.050) than that of global coffee brand shops. Whereas, the levels of "representativeness" of global coffee brand shops was significantly higher (p=0.003) than that of local coffee brand shops. Based on the results, the global coffee brand shops should pay attention to internal marketing and the local coffee brand shops must strive to improve service quality through strategies such as improving brand awareness and developing representative beverages and foods.

Impact Resistance Reliability of Sn-1.2Ag-0.5Cu-0.4In Solder Joints (Sn-1.2Ag-0.5Cu-0.4In 조성 솔더 접합부의 내 충격 신뢰성 평가)

  • Yu, A-Mi;Lee, Chang-Woo;Kim, Jeong-Han;Kim, Mok-Soon;Lee, Jong-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.226-226
    • /
    • 2008
  • 지난 10여년 동안 Sn-3.0Ag-0.5(wt%)Cu 합금은 대표 무연솔더 조성으로 다양한 전자제품의 실장 및 접합에 적용되어 왔으며, 그 신뢰성 역시 충분히 검증된 바 있다. 그러나 최근 Ag 가격의 급격한 상승과 솔더 접합부의 내 충격 신뢰성을 보다 향상시키고자 하는 업계의 동향은 Ag의 함량이 낮은 무연솔더 조성의 적용 확대를 유도하고 있다. 이에 따라 본 연구자들은 저 Ag 함유 무연슬더로 Sn-1.2Ag-0.5Cu-0.4In 조성을 제안한 바 있는데, 이는 Sn-3.0Ag-0.5Cu 조성 이상의 solderability를 가지면서도 그 금속원료 가격이 약 20% 가량 저렴한 특징을 가진다. 또한 열 싸이클링 (cycling) 테스트를 통한 슬더 조인트의 신뢰성을 평가한 결과, Sn-3.0Ag-0.5Cu에 크게 뒤떨어지지 않는 양호한 특성이 관찰되었다. 따라서 본 연구에서는 열 싸이클링 테스트와 더불어 최근 그 중요성이 지속적으로 커지고 있는 내 충격 신뢰성 평가 시험을 실시하여 개발된 4원계 무연솔더 조성의 기계적 특성을 기존 무연솔더 조성과 비교, 분석해 보았다. 각 솔더 조성은 솔더 볼 형태로 제조되어 CSP(Chip Scale Package) 상에 범핑 (bumping)되었으며, CSP를 PCB(Printed Circuit Board) 상에 실장하는 공정에서도 Sn-3.0Ag-0.5Cu 및 Sn-1.2Ag-0.5Cu-0.4In의 두 종류의 솔더 페이스트가 사용되었다. 본 연구에서의 내 충격 신뢰성 시험에는 자체 제작한 rod drop 시험기를 사용하였는데, 고정된 CSP 실장 board의 후면 부위를 일정한 높이에서 추를 반복적으로 자유 낙하시켜 급격한 충격을 주는 방식으로 실험을 실시하였다. 이 때 추의 무게는 30g, 낙하 높이는 10cm 였으며, 추의 낙하 시 측정된 board 의 휨 변위량은 약 0.7mm로 측정되었다. 사용된 CSP와 PCB 는 모두 daisy chain 방식으로 연결되어 있기 때문에 저항측정기를 사용한 간단한 실시간 저항 측정 방법으로 시험 이력에 따른 파단부의 발생 시점과 대략의 위치를 손쉽게 확인할 수 있었다. 솔더 조인트의 파단 기준 저항값으로 $1000\Omega$을 설정하였으며. 각 조건 당 5 개 이상의 샘플에 대해 평가를 실시한 후 그 평균값을 조사하였다. 시험 결과 제안된 Sn-1.2Ag-0.5Cu-0.4In 조성은 대표적인 저 Ag 함유 조성인 Sn-1.0Ag-0.5Cu에 비해서는 떨어지는 내 충격 신뢰성을 나타내었지만, 우수한 연성에 기인하여 Sn-3.0Ag-0.5Cu 조성에 비해서는 약 2 배 이상 우수한 신뢰성이 관찰되었다. 또한 CSP의 실장 시 Sn-3.0Ag-0.5Cu보다 Sn-1.2Ag-0.5Cu-0.4In 조성 솔더 페이스트를 적용한 경우에서 보다 우수한 내 충격 신뢰성을 나타내어 기본적으로 개발된 Sn-1.2Ag-0.5Cu-0.4In 솔더 페이스트가 Sn-3.0Ag-0.5Cu 조성의 기존 솔더 페이스트 보다 내 충격 신뢰성이 우수함을 검증할 수 있었다. 각 조성의 솔더 조인트를 $150^{\circ}C$ 에서 500시간 aging한 후 실시한 내 충격 신뢰성 평가에서는 모든 조성에서 그 신뢰성이 급감하는 경항을 나타내었으나, Sn-1.2Ag-0.5Cu-0.4In가 Sn-l.0Ag-0.5Cu보다도 그 상대적인 신뢰성이 우수한 것으로 관찰되었다. 이와 같이 aging 후 실시하는 충격시험은 가장 실제적인 상황과 유사한 조건이므로 상기의 실험 결과는 매우 고무적이었으며, 이에 대한 보다 면밀한 분석이 요청되었다. 마지막으로 파면 및 미세조직 관찰을 통하여 각 조성에서의 충격 파단 특성을 비교, 분석해 보았다.

  • PDF

Optimization of Microbial Production of Ethanol form Carbon Monoxide (미생물을 이용한 일산화탄소로부터 에탄올 생산공정 최적화)

  • 강환구;이충렬
    • KSBB Journal
    • /
    • v.17 no.1
    • /
    • pp.73-79
    • /
    • 2002
  • The method to optimize the microbial production of ethanol from CO using Clostridium ljungdahlii was developed. The kinetic parameter study on CO conversion with Clostridium ljungdahlii was carried out and maximum CO conversion rate of 37.14 mmol/L-hr-O.D. and $K_{m}$ / of 0.9516 atm were obtained. It was observed that method of two stage fermentation, which consists of cell growth stage and ethanol production stage, was effective to produce ethanol. When pH was shifted from 5.5 to 4.5 and ammonium solution was supplied to culture media as nitrogen source at ethanol production stage, the concentration of ethanol produced was increased 20 times higher than that without shift. Ethanol production from CO in a fermenter with Clostridium ljungdahlii was optimized and the concentration of ethanol produced was 45 g/L and maximun ethanol productivity was 0.75 g ethanol/L-hr.