• Title/Summary/Keyword: 시운전

Search Result 385, Processing Time 0.026 seconds

A Study on Tail Vibration Reduction for the Next Generation High Speed EMU (차세대 분산형 고속열차의 후미진동 저감에 관한 연구)

  • Jeon, Chang-Sung;Kim, Young-Guk;Kim, Seok-Won;Kim, Sang-Soo;Choi, Sung-Hoon;Park, Tae-Won
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.6
    • /
    • pp.543-549
    • /
    • 2012
  • This study describes the tail vibration reduction for the next generation high speed EMU(HEMU-430X). The model of 6 cars was generated and the calculation was performed using VAMPIRE(railway vehicle dynamic software). In view of ride characteristics, HEMU-430X was expected to sway at the tail because of the yaw damper direction. The lateral acceleration of vehicle body exceeded the criteria because of hunting. To reduce this hunting motion, some methods such as wheel profile change, the change of damping coefficient for the 2nd lateral damper, the damping coefficient change of yaw damper were tested, but had little effect. Finally, the yaw damper direction was changed and the tail vibration disappeared. In real running test, the tail vibration appeared at the speed of 150km/h and the yaw damper direction change made the vehicle stable at the speed of 300km/h. The maximum test speed of HEMU-430X is 430km/h. If the tail vibration appears at higher speed, some other methods in this study may be considered to reduce it.

A Study on Establishment of Technical Guideline of the Installation and Operation for the Efficient Bio-gasification Facility of Pig Manure and Food Waste(III): Design and Operation Guideline (가축분뇨 병합처리 바이오가스화를 위한 설계 및 운전 기술지침 마련 연구(III) 설계 및 운전 지침(안) 중심으로)

  • Lee, Dongjin;Moon, HeeSung;Son, Jihwan;Bae, Jisu
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.3
    • /
    • pp.99-111
    • /
    • 2017
  • The purpose of this study is to provide a design and operation technical guideline for meeting the appropriate design criteria to bio-gasification facilities treating organic wastes. Based on the results obtained during the field surveys, the overall design and operation guidelines for bio-gasification facilities, monitoring items, cycle and commissioning period were presented. According to the flow of anaerobic digestion process, Various design factors for bio-gasification facilities were proposed in this study. When designing the initial anaerobic digestion capacity, 10 ~ 30% of the treatment capacity was applied considering the discharge characteristics by the incoming organic wastes. At the import storage hopper process, limit concentration of transporting organic wastes was limited to TS 10 % or less, and limit concentration of inhibiting factor was suggested in operation of anaerobic digester. In addition, organic loading rate (OLR) was shown as $1.5{\sim}4.0kgVS_{in}/(m^3{\cdot}day)$ for the combined bio-gasification facilities of animal manure and food wastes. Desulfurization and dehumidification methods of biogas from anaerobic digestor and proper periods of liquifization tank were suggested in design guideline. It is recommended that the operating parameters of the biogasification facilities to be maintained at pH (acid fermentation tank 4.5~6.5, methane fermentation tank 6.0~8.0), temperature variation range within $2^{\circ}C$, management of volatile fatty acid and ammonia concentration less than 3,000 mg/L, respectively.

Review for Applying Spent Fuel Pool Island (SFPI) during Decommissioning in Korea (원전해체시 독립된 사용후핵연료저장조 국내 적용 검토)

  • Baik, Jun-ki;Kim, Chang-Lak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.2
    • /
    • pp.163-169
    • /
    • 2015
  • In many nuclear power plant sites in Korea, high density storage racks were installed in the spent fuel pool to expand the spent fuel storage capacity. Nevertheless, the capability of the Hanbit nuclear site will be saturated by 2024. Also, 10 NPPs will reach their design life expiration date by 2029. In the case of the US, SFPI (Spent Fuel Pool Island) operated temporarily as a spent fuel storage option before spent nuclear fuels were transported to an interim storage facility or a final disposal facility. As a spent fuel storage option after shutdown during decommissioning, the SFPI concept can be expected to have the following effects: reduced occupational exposure, lower cost of operation, strengthened safety, and so on. This paper presents a case study associated with the regulations, operating experiences, and systems of SFPI in the US. In conclusion, the following steps are recommended for applying SFPI during decommissioning in Korea: confirmation of design change scope of SFPI and expected final cost, the submission of a decommissioning plan which is reflected in SFPI improvement plans, safety assessment using PSR, application of an operating license change for design change, regulatory body review and approval, design change, inspection by the regulatory body, education and commissioning for SFPI, SFPI operation and periodic inspection, and dismantling of SFPI.

Program Development on the Thermofluidodynamic Analysis of LNG Storage Tanks (LNG 저장탱크의 종합 열유동 해석프로그램 개발)

  • Kim Hoyeon;Choi Sunghee;Bak Young;Lee Junghwan;Yoon Ikkeun;Kim Donghyuk;Ha Jongmann;Joo Sangwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.2 s.14
    • /
    • pp.52-61
    • /
    • 2001
  • Cryogenic LNG(Liquefied Natural Gas) which is stored in the cylindrical storage tanks of $100,000m^3$ has very complex flow phenomena and the changes of thermal properties with exterior conditions and operation modes. These complex thermofluid behaviors are affected by the storage, exterior conditions of LNG, design specifications and heat transfer characteristics of tanks. Also, those have influence on the stable storage and supply of LNG in the storage tanks. Thus this study peformed the analysis on the 2-D heat transfer of the tank with exterior conditions, on the Cool Down Process in order to cool down the LNG Storage Tank at the initial normal state, and on the Filling Process considered for incoming and rising of LNG. The analysis on the Mixing LNG Storage was studied too. At last, the visualized program on the complex thermofluidodynamic analysis was developed on the basis of the above analyses. The development of this program becomes to be used to the basic design of the commercial tanks as well as to assure technical skill of the analysis on the thermal stability of the stored LNG in the LNG Storage Tank.

  • PDF

A Survey on the Heavy Metal Concentration of Soil Samples around Onsan Industrial Complex (온산공단(溫山工團)주변토양의 중금속(重金屬) 농도조사)

  • Lee, Su-Rae;Song, Ki-Joon
    • Korean Journal of Environmental Agriculture
    • /
    • v.4 no.2
    • /
    • pp.88-94
    • /
    • 1985
  • In order to investigate the pollution potential of soils after the construction of Onsan Industrial Complex(non-ferrous metal refineries), concentrations of hazardous heavy metals were analyzed for soil samples collected from paddy, upland, orchard and forest soils around the Complex during the period of March 1978 to May 1979. The results are summarized as follows. 1) The concentrations of heavy metals (air-dry basis) for cultivated soil samples from 46 sites were obtained in the range of trace-9.3 ppm As, trace-0.6 ppm Cd, 4${\sim}$22 ppm Cu, trace-0.37 ppm Hg, 6${\sim}$43 ppm Pb and 27${\sim}$93 ppm Zn, which were regarded as non-polluted when compared with the whole Korea data for non-polluted paddy soils. 2) When the heavy metal concentrations were compared with respect to paddy, upland and orchard soils, no significant difference was observed in As, Cd, Cu and Zn whereas significant difference was observed in Hg and Pb. When they were compared with respect to region surrounding the Complex, no significant difference was observed in As, Cd, Hg whereas significant difference was observed in Cu and Pb. 3) Soil samples from several sites near Korea Zinc Refinery were contaminated with Cd, Pb and Zn, due to the accidental emission during its testing operation. Any further contamination was not observed after regular operation of the Refinery.

  • PDF

A study on the Vibration Reduction of the Commercial High-speed Train (운영 중인 고속열차의 진동저감에 관한 연구)

  • Jeon, Chang-Sung;Choi, Sunghoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.697-704
    • /
    • 2017
  • This study was carried out to investigate and alleviate the vibration problem of commercial high-speed trains. First, the measurement of the carbody vibration was performed, in order to determine the vibration level of the high-speed train. The measurement result showed that the vibration level of the driver cab was higher than that of the passenger car and that the vibration became bigger toward the trailing end of the train. The vertical vibration of the driver cab and passenger car was larger than the transverse vibration, and the maximum value of the vibration in the ballast section was larger than that in the concrete section. A dynamic analysis was carried out to improve the vibration of the KTX-Sancheon train. The results of the analysis showed that it is necessary to reduce the vibration of the driver cab and both ends of the passenger cars. To reduce the vibration of the driver cab, it was recommended that the stiffness of the secondary coil spring be reduced and the damping coefficient of the secondary vertical damper be increased. It was found that the failure of the suspension system could be the origin of the vibration problem of the high-speed train. The proper management of wheel wear plays an important role in the improvement of the operation efficiency and reduction of the carbody vibration of high-speed trains, and research is underway to change the present wheel profile to increase the mileage between wheel turning.

A Study on the Remote Control System for Outboard Engine (선외기 원격제어시스템에 관한 연구)

  • An, Byeong-Won;Jeong, Gap-Dong;Kim, Hyeon-Su;Bae, Cheol-Oh
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.71-74
    • /
    • 2006
  • Currently offshore fisheries are one of shrinking industries and fishermen are getting older. Moreover it is difficult to work fisheries for decreasing fishermen as the time goes. Two people per a boat work together at least for proper fisheries. If the unskilled fisherman boards on boat, it will make some troubles to speak each other and diminish the efficiency of working because one person should control the boat. So it need to study the remote control system for leasure and outboard engine that can control and work at the same time. The remote control system is consisted of engine revolution, steering gear and forward reverse neutral gear controls. These three controls are made by position and speed control using DC motor, and microprocessor is used to communicate and control the engine speed This system can be controled and worked alone and we tested the system at sea and confirmed that the system works properly.

  • PDF

Safety Evaluation of the Dynamic Behavior of HEMU-430X using the Accelerometers of UIC 518 OR (UIC 518 OR의 가속도계를 이용한 차세대고속열차(HEMU-430X) 동적 거동 안전성 평가)

  • Ryu, Sang-Hyun;Kim, Sang-Soo;Hong, June-Hee;Song, Doo-Sang;Guo, Yang-Yang
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.1
    • /
    • pp.32-39
    • /
    • 2013
  • The next generation high-speed train(HEMU-430X) is Korea's first electric multiple unit type, high speed vehicle resulting from a national R&D project. Tests have been conducted on the Kyungbu High Speed Line running at speeds up to 354.64km/h, and analysis of the dynamic behavior of the train was carried out to evaluate its safety. In this study, a simplified method using an accelerometer(the method specified in UIC 518 OR) was chosen to analyze the safety of the train's dynamic behavior. The section chosen for analysis section was ${\pm}10{\sim}20km/h$ with respect to the maximum speed point. In addition, we analyzed the trend of this dynamic behavior with increasing speed by comparing the analyzed values with those of UIC 518 OR. The dynamic behavior results met the limit values of UIC 518 OR and the study indicates that this trend is predicted to continue at speeds above 354km/h.

Development and its Application for Energy Efficiency Operation Indicator and Energy Efficiency Design Index Monitoring System on the Ship (선박의 에너지효율운전지표와 에너지효율설계지수의 모니터링 시스템 개발과 그 응용)

  • Lee, Don-Chool;Kim, Eoue-Sek;Joo, Ki-Se;Nam, Jeong-Gil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.500-507
    • /
    • 2010
  • Regard to the global warming, the shipping industries are progressed the dedicated endeavor to reduce greenhouse gas. As the study results of 2009 GHG study team, the $CO_2$ emission of shipping industries exceeded slightly 1.0 billion ton during one year(2007) and it is 3.3% of total $CO_2$ amount exhausted from all industries. This paper are introduced the energy efficiency design index / operation indicator monitoring system(EDiMS) which matched with EVAMOS software released by the dynamics laboratory of Mokpo maritime university. EDiMS can continuously be monitored amounts of $CO_2$, NOx, SOx, and PM emitted from ship and it can be applied as the useful tool of the inventory work of air pollution and the ship energy management plan for the mitigation or reduction of ship emission.

A study on an instantaneous angular velocity and torque fluctuation for marine diesel engine (선박용 디젤 기관의 순간 각속도와 토크 변동에 관한 연구)

  • Jung, Gyun-sik;Lee, Ji-woong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.7
    • /
    • pp.722-728
    • /
    • 2015
  • The demand for shipboard energy management is expected to gradually increase based on ship energy efficiency management plans (SEEMPs), which have been in use since January 1, 2013. Therefore, the fuel consumption of the main engine, which occupies the greatest portion of the energy used, along with elements related to the engine power, should be strictly monitored. There are many different methods for indicating the engine power. However, this study performed an experiment to monitor the status of a ship's engine power in real time using an encoder and a proximate switch, which are economical to purchase and easy to install. In the experiment, the angular velocity during one cycle of a two-stroke low-speed engine was measured, and the measured data were converted to the torque fluctuation. The angular velocity during an abnormal firing condition in the cylinder was also measured, and the torque fluctuation as a result of a misfire was considered. The results were compared with sea trial data to determine the reliability. In this study, the status of the engine power was determined using the torque fluctuation of the main engine in an operating ship.