• Title/Summary/Keyword: 시스템 운전 방식

Search Result 468, Processing Time 0.026 seconds

A Characteristic Improvement for the Parallel Operation of Z-source Inverters (Z-소스 인버터의 병렬운전 특성 개선)

  • Kim, Yoon-Ho;Lee, Woog-Young;Seo, Kang-Moon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.56-61
    • /
    • 2007
  • In this paper, a circulating current reduction approach for the parallel operation of fuelcell systems with Z-source inverters is investigated. The carrier phase shifted SPWM(Sinusoidal Pulse Width Modulation) is used as a modulation method since it has an advantage in reducing output current harmonics. However, when this technique is applied to the parallel operation of Z-source inverters, it additionally produces circulating currents. A coupled circulating current reactor is used to reduce circulating current generated by the parallel operation of Z-source inverters and to reduce output current harmonics. The proposed circulating current reduction approach using coupled circulating current reactors is verified through simulation and experiment.

Droop Method For Parallel Inverters In High-Capacity Islanded Microgrid Using Virtual Inductance (대용량 마이크로그리드 독립 운전 모드시 가상 인덕터를 활용한 인버터 병렬운전 제어 연구)

  • Jung, Kyosun;Kim, Donghwan;choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.459-460
    • /
    • 2014
  • 여러 가지 분산 발전 시스템들은 마이크로그리드의 형태를 지니고 있다. 하나의 분산 발전 시스템과 비교하여 마이크로 그리드는 더 좋은 시스템 신뢰성과 제어 적응성을 가지고 있다. 이 마이크로그리드는 계통연계모드에서 부하의 수요를 담당하게 되고, 계통 사고가 발생할 시 단독운전모드로 동작을 해야 한다. 드룹제어방식은 이 때 각각의 분산발전시스템에서의 유효전력과 무효전력 부하 sharing을 통해 안정적으로 전력을 공급 할 수 있다. 본 논문에서는 드룹제어를 활용한 100KW급 대용량 인버터 병렬 운전 시스템을 제안하였다. 그리고 P-Q decoupling을 위한 가상 인덕터를 이용하여 개선된 전력 sharing에 대해 연구하고 PSIM을 통해 이를 검증하였다.

  • PDF

PC Based-Proto Type 고장검출 프로그램에 의한 중수로 안전계통(SDS#1, SDS #2)주기시험 시스템 개발

  • 김석남;장익호;김항배;한재복;이상용
    • Nuclear Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.894-897
    • /
    • 1995
  • 원자력 발전소의 안전계통은 요구된 신뢰도를 확보하기 위하여 각 트립 변수(공정계통 및 핵관련 총11개)회로의 센서 및 트립로직으로 구성된 각자의 채널에 대하여 주기적으로 운전중에 운전원에 의해 수동으로 수행하므로 안전계통에 대한 신뢰도를 화보하고 있다. 안전계통에 대한 시험자동화는 컴퓨터에 의해 시험 신호의 발생과 시험 결과의 표시 및 기록이 자동적으로 프로그램에 의해서 수행되는 것을 의미하며, 시험 자동화에 의해 주기 시험에 따른 시험시간 단축과 운전원의 심리적 부담을 경감하여 운전원에 의한 인적 실수 방지 및 계통 신뢰도 향상에 기여하는 것은 물론 계통을 단순화하고 기기경비의 절감 효과를 가져온다. 현재 기존 중수로 발전소는 직접 시험 방식에 의해 모의 신호를 시험 대상 채널의 센서부분에 보내어 안전 계통을 시험하여 해당 루프에 대한 건전성을 점검하고 있는데, 이 방식은 시험회로가 복잡하여 이로인한 기기의 설치 경비 상승, 유지 보수의 부담 증가 및 운전원의 주기 시험에 대한부담감으로 인적 실수를 유발하는등 계통 신뢰도 저하의 문제점이 지적되어 개선이 요구된다.

  • PDF

A Comparative Study of the Flexible Moving Block System and the Fixed Block System in Urban Railway (도시철도에 있어 이동폐색방식과 고정폐색방식의 상호비교 연구)

  • Jeong, Gwangseop;Park, Jeongsoo;Won, Jaimu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5D
    • /
    • pp.723-730
    • /
    • 2006
  • Recently, The flexible moving block system in train operation has been introduced to the worldwide rail transportation markets. This paper is a comparative study of the conventional fixed block systems effects and the flexible moving block system on train operating time saving. Based on the literature review, the new algorithm is developed. It is to calculate the optimum headway time of the train. The proposed algorithm can overcome some of the existing algorithm problems, such as the limits of the data and unaware of the rail characteristic. The total travel time saving effect has been analyzed by applying the skip stop scheduling system to the each block system. The results of this study indicated that the total travel time is approximately 40% decreased and the schedule velocity is approximately 24% improved when the moving block system is applied. The results of this study could be used as a theoretical basis for the selection of rail signal system in Seoul's subway number 2 line.

Control strategy for economic operation of an ice-storage system considering cooling load variation (냉방부하 변동을 고려한 빙축열시스템의 경제적 운전방식)

  • 정성훈;이대영;강병하;김우승
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.2
    • /
    • pp.140-149
    • /
    • 2000
  • A comparative analysis was peformed on the operation cost at partial loads between ice storage systems with the two conventional control strategies, i.e., storage priority and chiller priority. The storage priority control is shown to be more economic for small cooling loads, while the chiller priority control is superior when the cooling load is as large as the design value. Based on this finding, a new control strategy is devised for an ice-storage system to minimize the operation cost at any cooling load. The new control strategy is found to be comparable to the chiller priority for large cooling loads, while it is more economic for small loads compared to the conventional control strategies. The practicality of the new control strategy is also confirmed through a performance test applying the new control strategy to an existing ice-storage system.

  • PDF

Control Method for Parallel Operation of Grid-connected 3-Level NPC Inverters (계통연계형 3-레벨 NPC 인버터의 병렬운전 제어기법)

  • Kim, Jooha;Jung, Sanghyuk;Yang, Seokhyun;Choi, Sewan;Kim, Kwangseob
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.378-379
    • /
    • 2013
  • 마이크로그리드 내의 ESS는 독립운전 및 계통연계 두 가지 운전모드가 가능해야 하며 인버터는 용량의 확장성, 시스템의 보수 편리, 신뢰성 향상 등의 장점 때문에 주로 모듈화 한다. 이때 모듈간의 오차, 비동기 된 PWM의 문제로 순환전류가 발생하기 때문에 병렬운전 제어기법이 필요하다. 본 논문에서는 3-레벨 NPC인버터 병렬연결 시 순환전류 제거에 적합하고 독립운전에서 계통연계로 모드전환이 가능하며 PWM동기화 기능을 갖는 마스터-슬레이브 방식의 병렬운전 시스템을 제안하였고 실험을 통해 타당성을 검증하였다.

  • PDF

Development of generator excitation system with main/standby controller in Inchun thermal power plant #4 (인천화력 4호기 발전기용 주/부 제어기를 갖는 정지형 여자시스템 개발)

  • 류호선;김수열;김장목;임익헌
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.507-514
    • /
    • 1999
  • 한국전력에서는 인천화력 4호기 수명연장의 일환으로 여자시스템 교체가 이루어졌다. 기존의 회전형 여자 시스템은 발전기축에 부여자기와 교류여자기가 부착되어 회전하는 형태로 과거 스위칭소자 용량의 한계를 극복하기 위하여 설계된 시스템으로 전력연구원에는 회전형 여자시스템을 새롭게 개발된 아날로그와 디지털의 하이브리드 제어기와 대용량 사이리스터 제어정류기를 가지고 잇는 정지형 이중화 여자시스템으로 교체하였다. 설비의 신뢰성을 높이기 위하여 정지형 여자시스템의 상태를 순시 감시하기 위한 데이터 취득 시스템이 설치 되었고 위상제어정류기는 운전시 1대가 고장이 발생하더라도 발전기의 전부하 능력을 유지하기 위하여 3대가 병렬로 운전되는 N+1 방식을 채택하였다. 시스템의 신뢰성 시험은 성능평가를 위한 시운전시에 검증되었으며 성공적으로 운전중에 있다.

  • PDF

A Method of Detecting the Aggressive Driving of Elderly Driver (노인 운전자의 공격적인 운전 상태 검출 기법)

  • Koh, Dong-Woo;Kang, Hang-Bong
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.11
    • /
    • pp.537-542
    • /
    • 2017
  • Aggressive driving is a major cause of car accidents. Previous studies have mainly analyzed young driver's aggressive driving tendency, yet they were only done through pure clustering or classification technique of machine learning. However, since elderly people have different driving habits due to their fragile physical conditions, it is necessary to develop a new method such as enhancing the characteristics of driving data to properly analyze aggressive driving of elderly drivers. In this study, acceleration data collected from a smartphone of a driving vehicle is analyzed by a newly proposed ECA(Enhanced Clustering method for Acceleration data) technique, coupled with a conventional clustering technique (K-means Clustering, Expectation-maximization algorithm). ECA selects high-intensity data among the data of the cluster group detected through K-means and EM in all of the subjects' data and models the characteristic data through the scaled value. Using this method, the aggressive driving data of all youth and elderly experiment participants were collected, unlike the pure clustering method. We further found that the K-means clustering has higher detection efficiency than EM method. Also, the results of K-means clustering demonstrate that a young driver has a driving strength 1.29 times higher than that of an elderly driver. In conclusion, the proposed method of our research is able to detect aggressive driving maneuvers from data of the elderly having low operating intensity. The proposed method is able to construct a customized safe driving system for the elderly driver. In the future, it will be possible to detect abnormal driving conditions and to use the collected data for early warning to drivers.

A Study on Stair Case Wave PWM Inverter System by Microprocessor (마이크로프로세서에 의한 계단파 PWM 인버어터 시스템에 관한 연구)

  • 이종수;김영길;이철우
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.2 no.4
    • /
    • pp.70-74
    • /
    • 1988
  • 계단파 5전위 PWM 출력전압은 CTI회로를 구성하는 스위칭 소자의 구동신호에 의하여 이루어진다. 이 CTI회로를 구동시키기 위한 구동신호는 Natural Sampling 방식의 변조신호를 10-6 범위인 변환 오차로 디지틀 변환하고, 이 신호의 데이터에 의한 마이크로프로세서 운전 시스템을 구성하였다. 이 방식에 의하면, CTI회로의 V/F제어를 위한 1[Hz]~60[Hz]의 시스템에 소요되는 메모리의 용량은 어드레스 카운터방식에 비하여 0.8%이었다.

  • PDF

Active Power Filter with Z-Source Network (Z-소스 네트워크를 갖는 능동전력필터)

  • Kim, J.H.;Jung, Y.G.;Lim, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.223-226
    • /
    • 2007
  • 본 연구에서는 Z-소스 네트워크를 갖는 능동전력필터 시스템을 제안하였다. 제안된 방식의 동작원리는 종전의 V-소스 능동전력필터와 동일하나, 고조파 보상 전류가 Z-소스 인버터에 의하여 발생된다는 점이 차이가 있다. 또 제안된 시스템을 서로 병렬 운전하는 경우와 종전의 능동전력필터와 병렬 운전하는 방법을 제안하였다. 제안된 시스템은 PSIM 시뮬레이션에 의하여 타당성이 입증되었다.

  • PDF