• Title/Summary/Keyword: 시료의 이동과 보관

Search Result 14, Processing Time 0.034 seconds

A Study on the Effect of Transportation and Storage on Sample Disturbance (시료의 이동과 보관이 시료 교란에 미치는 영향에 관한 연구)

  • Kim, Byoung-Il;Lee, Seung-Hyun;Yoo, Wan-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.1159-1165
    • /
    • 2007
  • This study aims to determine the effects of sample movement and storage on sample disturbance. To this end, non-disturbed samples collected from the OOregion, Gwangyang City, Jeonranam-do. Then, unconfined compression and consolidation tests were performed on the samples in the field, Seoul Lab and Seoul Lab after 4 weeks. Based on failure strain rate$(\epsilon_f)$, volume strain rate$(\epsilon_{\nu})$, and void ratio change$({\Delta}e/e_0)$ obtained from the test results, sample disturbance was evaluated. The sample disturbance level was used to compare and analyze the influences of transportation and storage on sample disturbance.

  • PDF

Experimental research trends on Pressure Core Samples (압력 코어를 이용한 현장 가스 하이드레이트 함유 시료 연구 현황)

  • Lee, Joo Yong;Jung, Jaewoong;Ryu, Byung Jae;Lee, Jaehyung;Kim, Sejoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.124.1-124.1
    • /
    • 2011
  • 저온 고압의 환경에서 안정한 하이드레이트 함유 퇴적물 연구를 위하여 현장의 압력을 유지하여 코어를 회수할 수 있는 압력 코어러 (Pressure Corer)가 개발된 이후로 다양한 방법으로 압력코어를 이용한 연구가 진행되어 왔다. 하이드레이트의 안정영역 특성상 일반 코어러 샘플에서는 하이드레이트 함유 퇴적물의 회수가 용이하지 않았던 이유로 압력코어샘플응 이용한 현장 하이드레이트 함유 퇴적물의 연구는 필수적이다. 초기 단계에서는 압력코어를 이용한 비파괴 검사와 단순 감압 시험이 이루어졌다. 비파괴 검사를 통하여서는 X-ray 단면, 감마 밀도 (gamma density), 음파 속도 등이 측정 되었으며 감암 시험을 통하여서는 시료 내 하이드레이트 함유량을 산정하였다. 감압 후 다양한 지화학 분석이 후행되었다. 가스 하이드레이트 함유 퇴적물의 물성과 생산 거동이 점차 부각됨에 따라 압력코어 시료를 순간 감압하여 액체 질소에 보관하였다가 압밀시험, 삼축 압축 시험 등 물성 시험이 수행되었으며 수행 동안 X-ray 단면, 비저항, 음파 속도 등의 물성측정이 이루어졌다. 또한 액체 질소 보관 시료를 이용하여 감압법, 열염수 주입법, 열자극 법 등을 적용하여 생산 실험을 수행하기도 하였다. 이후에 압력코어 시료 절단 및 이동 시스템이 개발됨에 따라 보다 다양하고 많은 연구자 들이 압력코어 시료를 이용할 수 있게 되었으며 물성 연구뿐만 아니라 미생물 연구에 까지 압력코어 시료가 사용되게 되었다. 최근에는 절단 시료를 이용한 생산 실험 연구 또한 진행되었다.

  • PDF

Analysis on Surface of Seed Potato using Nano-Spectrometric Sensor (나노 분광 센서를 이용한 씨감자 표면 표현형 분석)

  • Choi, Il Soo;Oh, Jong-woo;Um, Tae-Un;Lee, DongHoon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.87-87
    • /
    • 2017
  • 농산물의 품질 및 성분을 측정하는데 있어 기존의 화학적 분석 방식은 정밀도가 높으나 측정에 소요되는 시간과 비용이 많이 들어, 현장 적용하기에는 한계가 있다. 일반적으로 근적외선 분광 분석(Near Infra Red Spectroscopy, NIRS) 방법은 가공 과정에 따라 빠르게 변화되는 단백질 조성 및 수분함량 측정 등에 이용되고 있다. 분석에 소요 시간이 많이 걸리는 켈달법(Kjeldahi method)에 비해 NIR 분광 분석을 통한 보정으로 연속적인 모니터링이 가능하다. 본 연구에서 사용된 시료를 고정시키기 위한 프레임을 제작한 후 NIR센서와 광원인 LED의 각도를 고정시키고 측정 대상체인 사절된 감자 크기에 따라 시료를 고정시킬 수 있는 프레임을 반사면에 위치시켰다. 확산 반사법을 이용하여 프레임에 씨감자 시료를 고정 시킨 후 백색 LED를 이용하여 감자 표면에 빛을 반사시켜 3일 동안 12시간 마다 해당 시료들(열처리, 비누용액 침지, 생감자)의 스펙트럼을 측정하였다. 해당 시료들은 측정 기간 동안 저온상태($4^{\circ}C$)와 실온상태($20^{\circ}C$)에서 보관되었다. 실험 결과는 파장대 145nm에서 저온상태에서 보관된 생감자는 시간경과에 따른 흡광도의 결정 계수값($r^2$)은 0.98 이었다. 이는 감자가 저온에서 생감자의 상태 변화가 일어나고 있다는 것을 의미하고 파장대 145nm에서 시간에 따른 저온상태에서 보관한 감자의 상태 변화 예측이 가능함을 의미한다. 비누용액에 침지시킨 후 실온에 보관한 감자는 시간이 경과함에 따라 파장이 증가함에 따라 흡광도가 증가하였다. 이는 감자에 들어있는 Polyphenol Oxidase 함량 변화로 갈변 현상이 일어난 것을 알 수 있다. 또한 실온에서 보관한 생감자도 시간 경과에 따라 갈변 현상이 일어났지만 용액에 침지시킨 감자보다는 갈변 현상이 36시간 이후로 발견되었다. 열처리 후 실온에서 보관한 감자의 경우에는 갈변현상이 나타나지 않았다. 저온상태에서 보관한 감자시료들 모두 갈변형상이 나타나지 않았지만, 24시간이 지난 후 용액에 침지시킨 감자는 갈변 현상이 발생되었다. 생감자와 열처리한 감자는 시간 경과에 따른 갈변현상이 일어나지 않았으므로, 감자의 갈변현상은 감자의 표면 처리 방법에 국한되지 않고 온도에 영향을 더 많이 받는다는 것을 나타내고 있다. 본 연구는 향후 감자의 품질 및 성분 측정에서 간편하게 사용될 수 있는 감자의 품질 계측 기술에 기여할 것으로 판단된다.

  • PDF

Evaluation of Liquefaction Resistance of Sandy Soil Layer in Songlim-park, Pohang, Using Undisturbed Sample (불교란시료를 활용한 포항시 송림공원 사질토층의 액상화저항강도 평가)

  • Kim, Jongkwan;Han, Jin-Tae;Park, Ka-hyun;Lee, Seokhyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.12
    • /
    • pp.107-116
    • /
    • 2021
  • In this study, a set of laboratory liquefaction test has been conducted using undisturbed samples collected from Songlim-park, Pohang where liquefaction phenomenon had been observed in 2017. Soil samples were frozen right after tube sampling to minimize the disturbances during transport, storage, and test preparation. Cyclic triaxial test has been carried out to evaluate the liquefaction resistance ratio of undisturbed soil samples. As a result, the liquefaction resistance ratio of samples collected from 8.0~8.8 m and 11.0~11.8 m were almost similar, and these values were approximately 0.04~0.07 larger than values estimated by simplified assessment method using field test results. It is expected that the application of undisturbed sample for the evaluation of liquefaction resistance could contribute to the economical design of geotechnical structures.

QA/QC for 222Rn analysis in groundwater (지하수 중 222Rn 분석을 위한 정도관리)

  • Jeong, Do Hwan;Kim, Moon Su;Kim, Hyun Koo;Kim, Hye Jin;Park, Sun Hwa;Han, Jin Seok;Ju, Byoung Kyu;Jeon, Sang Ho;Kim, Tae Seung
    • Analytical Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.86-90
    • /
    • 2013
  • $^{222}Rn$ concentrations in the groundwater samples without standard material due to the short half-life (3.82 day) were measured through the establishment of the counting efficiency of LSC (Liquid Scintillation Counter) using a standard source of $^{226}Ra$. This study for Quality Assurance/Quality Control (QA/QC) of $^{222}Rn$ analysis was performed to analyze blank samples, duplicate samples, samples of groundwater sampling before and after. In-situ blank samples collected were in the range of 0.44~6.28 pCi/L and laboratory samples were in the range of 1.66~4.95 pCi/L. Their correlation coefficient was 0.9691 and the source contamination from sampling, migration and keeping of samples were not identified. The correlation coefficient between original and duplicate samples from 65 areas was 0.9987. Because radon is an inert gas, in case of groundwater sampling, it is considered to affect the radon concentration. We analyzed samples separately by groundwater sampling before and after using distilled water, but there is no significant difference for $^{222}Rn$ concentrations in distilled waters of two types.

Effects of Fining Treatments on Color and Clearness of Apple Wine (청징방법에 따른 사과와인의 색과 투명도에 미치는 영향)

  • Bang, Byung-Ho;Jeong, Eun-Ja;Kang, Hyeran;Rhee, Moon-Soo;Yi, Dong-Heui;Paik, Jean Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.3
    • /
    • pp.368-373
    • /
    • 2017
  • Comparative fining trials were conducted in a laboratory to study the effects of fining treatments including polyvinylpolypyrrolidone (PVPP) and bentonite on the color and clearness of apple wine. The wines were subjected to three different fining treatments: PVPP, PVPP+bentonite (applied at the same time), and PVPP+bentonite (24 h later). Based on the results, all treatments induced noticeable decreases in wine color (APHA value) and turbidity. The treatment including PVPP and bentonite at the same time provided the best results in relation to wine color and clearness. PVPP was the most effective in the reduction of phenolic compounds, which means it helped wine obtain a paler color. Organic acids and aromatic profile were not altered by the fining treatments.

Concentration of Formaldehyde and Acetaldehyde depending on the Time of Storage into Mineral Water (먹는샘물의 보관 기간에 따른 formaldehyde 및 acetaldehyde의 농도 변화)

  • Lee, Youn-Hee;Lee, Jun-Bae;Park, Ju-Hyun;Choi, Ja-Yoon;Ahn, Kyung-Hee;Ahn, Hye-Sil;Kwon, Oh-Sang;Kim, Tae-Seung;Han, Jin-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.3
    • /
    • pp.281-287
    • /
    • 2011
  • BACKGROUND: According to Korean regulations, bottled waters (BWs) can not be treated with chemical disinfectants like chlorine, so UV and ozone disinfection is applied. During the past several years, chemicals were detected in some BWs, and the public was concerned about the safety of BWs. METHODS AND RESULTS: Mineral waters were stored for 180 days at $25^{\circ}C$ and $50^{\circ}C$, tested acetaldehyde and formaldehyde by HPLC. When mineral waters were put in a PET bottles, the formaldehyde level ranged from 5 to $66{\mu}g/L$ during 180 days at $50^{\circ}C$. While the acetaldehyde level ranged from 31 to $221{\mu}g/L$, it was low than $16{\mu}g/L$ in glass bottle. CONCLUSION(s): This result showed that formaldehyde and acetaldehyde were detected higher in PET bottles than glass bottles, these also increased depending on the time of storage. Concentration of formaldehyde and acetaldehyde could be significantly influenced by the time of storage and temperature.

Long-term Changes in Polycyclic Aromatic Hydrocarbon Content of Paddy Soils in Youngnam area (영남지역 논토양에서 다핵방향족탄화수소 농도의 장기변동)

  • Nam, Jae-Jak;Hong, Suk-Young;Lee, Hee-Dong;Park, Chang-Young;Lee, Sang-Hak
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.40 no.3
    • /
    • pp.196-200
    • /
    • 2007
  • This study was to determine long-term changes of polycyclic aromatic hydrocarbons (PAHs) in paddy soils. To do this, we analyzed 16 PAHs in soil samples which were stored in the archive of Yeoungnam Agricultural Research Institute, Milyang, Kyeoungnam province, Korea. The samples used in this study were collected every year from 1978 to 2001 at the plough layer (0-12cm). In average, total PAHs accumulated in paddy soil was continuously decreased since 1980 when it peaked to be $237g\;kg^{-1}$. No significant changes were observed for PAHs having 5-6 phenyl rings for the past two decades, whereas PAHs with 3-4 phenyl rings were greatly decreased, reaching at about a half levels of the 1980's. It is worthy to be noted that the large reduction in PAHs with 3-4 phenyl rings has mainly been attributed to the decrease of PAHs in paddy soils for last 20 years. The major compounds accumulated were: phenanthrene > fluoroanthene > chrysene/benzo(b)fluoroanthene. The present results suggest that the switch of main fuels used in Korea from coal to petroleum around at the end of 1970's is likely contributed to decrease in PAH accumulation in paddy soils.

Rapid and Simple Analytical Method for Removing Patulin from Apple Juice Using Solid Phase Extraction (고체상 추출법(SPE: Solid Phase Extraction)을 이용한 국내 사과주스 중 Patulin 간편.신속 분석방법)

  • Yim, Jong-Gab;Jang, Hae-Won;Lee, Kwang-Geun
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.3
    • /
    • pp.257-262
    • /
    • 2010
  • Patulin, a secondary metabolite of mold, is commonly found in rotten apples. Many countries regulate patulin at levels ranging from 30 to $50\;{\mu}g/L$. Most analytical methods for removing patulin from apple juice include liquid-liquid extraction (LLE), which is time and labor intensive. To replace the LLE method, a solid-phase extraction (SPE) method has been developed for apple juice and unfiltered apple juice. A portion of the test sample was applied to a macroporous copolymer cartridge and washed with 5 mL of 1% sodium bicarbonate, followed by 5 mL of 1% acetic acid. Patulin was eluted with 5 mL of 2% acetonitrile in anhydrous ethyl ether. The mobile phase was tetrahydrofuran in water (0.8:99.2) and was detected with a UV detector at 276 nm. Recoveries ranged from 95 to 101% in test samples, and the minimum detectable level was 30 ppb. Because this SPE method is fast, easy, reliable, and inexpensive, it could be applicable for companies or analytical agencies to analyze patulin concentrations in apple juice.

A study on development of CRM by means of XRF analysis for fine ceramic ($BaTiO_3$) (티탄산바륨 소재의 XRF 분석용 CRM 개발에 관한 연구)

  • Kim, Young Man;Jeong, Chan Yee;Lim, Chang Ho;Song, Taek Yong;Lee, Dong Soo
    • Analytical Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.382-391
    • /
    • 1996
  • In this study, 12 different chemical species of fine ceramic($BaTiO_3$) were synthesized as the standard materials for the fast and accurate measurements of X-ray fluorescence spectrometry. Samples were diluted to sixteen times with the filling compound ($Li_2B_4O_7+LiBO_2$) in order to remove the matrix effect, and to get the convenient storage and homogeneity of ingredients. The matrix effects among the ingredients were corrected by the empirical coefficient method based on the Lucas-Tooth and Price model. The standard curve on 12 standard materials containing 15 elements were obtained by using X-ray fluorescence spectrometry at three different laboratories. The correlation factors of BaO, PbO, SrO, $Fe_2O_3$, $La_2O_3$, $SnO_2$, ZnO, $ZrO_2$, CaO indicated the relati vely good agreement over 0.995 among the three different laboratories. $SiO_2$ and $Al_2O_3$ showed the poor linearity because of their low fluorescence intensities.

  • PDF