• Title/Summary/Keyword: 시도주파수

Search Result 180, Processing Time 0.029 seconds

Correlation Analysis of Signal to Noise Ratio (SNR) and Suspended Sediment Concentration (SSC) in Laboratory Conditions (실험수로에서 신호대잡음비와 부유사농도의 상관관계 분석)

  • Seo, Kanghyeon;Kim, Dongsu;Son, Geunsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.5
    • /
    • pp.775-786
    • /
    • 2017
  • Monitoring sediment flux is crucial especially for maintaining river systems to understand morphological behaviors. Recently, hydroacoustic backscatter (or SNR) as a surrogate to empirically estimate suspended sediment concentration has been increasingly highlighted for more efficient acquisition of sediment dataset, which is difficult throughout direct sediment sampling. However, relevant contemporary researches have focused on wide range solution applicable for large natural rivers where H-ADCPs with relatively low acoustic frequency have been widely utilized to seamlessly measure streamflow discharge. In this regard, this study aimed at investigating hydroacoustical characteristics based on a very recently released H-ADCP (SonTek SL-3000) with high acoustic frequency of 3 MHz in order to capitalize its capacity to be applied for suspended sediment monitoring in laboratory conditions. SL-3000 was tested in a laboratory flume to collect SNR in conjunction with LISST-100X for actual sediment concentration and particle distribution in both sand and silt sediment injection in various amount. Conventional algorithms to correct signal attenuations for water and sediment were carefully tested to validate whether they can be applied for SL-3000. As result of analyzing the SNR-SSC correlation trand, through further study in the future, it is confirmed that SSC can be observed indirectly by using the SNR.

Comparison of the Effect of the Interpolation Function on the Performance of the Noise Source Imaging Technology (소음원 영상화 기술의 성능에 보간 함수가 미치는 영향 비교)

  • Park, Kyu-Chil;Yoon, Jong Rak
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.2
    • /
    • pp.268-274
    • /
    • 2016
  • To find the location of a random noise source present in the three-dimensional space is required at least four microphones. Using four microphones distributed in a three-dimensional space, noise source imaging technique was applied and evaluated on their performance. To compensate resolution problem which comes from both the position of the sensor array is fixed and the sampling frequency is low, up-sampling technique and interpolation function were applied. Five different interpolation methods were applied such as zero-padding, zero-order hold, first-order hold, spline function, and random signal padding. The up-sampling rate were chosen by two, four, eight times, and counting up 16 times. As a result, it was possible to more accurately estimate the position of the noise source according to the higher of the up-sampling rate. It also found that the first-order hold and the spline function's performance were slightly falling relative to other methods.

Sterilization of Yakju(Rice Wine) on a Serial Multiple Electrode Pulsed Electric Field Treatment System (직렬배열 다중전극 고전압 펄스 전기장 처리장치를 이용한 약주의 살균)

  • Mok, Chull-Kyoon;Lee, Sang-Ki
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.356-362
    • /
    • 2000
  • Yakju(rice wine) was sterilized with high-voltage square-wave pulses of $1\;{\mu}s$ duration at various electric field strengths and frequencies on a serial multiple electrode pulsed electric field(PEF) treatment system consisted of 7 electrodes connected in series. The initial microbial counts of Yakju were $1.88{\times}10^3{\sim}2.13{\times}10^4$ CFU/mL for total aerobes, $1.55{\times}10^3{\sim}2.85{\times}10^4$ CFU/mL for lactic acid bacteria and $1.72{\times}10^3{\sim}2.39{\times}10^4$ CFU/mL for yeasts. The sterilization of microorganisms in Yakju was a first order reaction and the sterilization effect increased as the field strength and the frequency increased. The $D_{Hz}-value$ and the $D_{PEF}-value$ decreased with the electric field strength. Yeast showed lower $D_{PEF}-value$ than bacteria. Lactic acid bacteria showed lower $D_{PEF}-value$ than general aerobic bacteria under the electric field strength below 30 kV/cm, but higher ones under that above 40 kV/cm. The $Z_{PEF}-value$ of general aerobic bacteria, lactic acid bacteria and yeast in Yakju were 39.4, 49.3 and 47.6 kV/cm, respectively. The PEF sterilization resulted in less changes in color and sensory properties than heat sterilization, and the PEF treated Yakju showed superior quality to the heat treated one. The commercial sterilization of Yakju was accomplished with 2-cycle treatment on the tested serial PEF treatment system.

  • PDF

A Study on the Vulcanization Reaction of Modified NR Blends by In-Situ Electrical Property Measurement (전기적 특성의 in-situ 측정에 의한 개질된 NR 블랜드의 가황 반응에 관한 연구)

  • Ha, Ki-Ryong;Suh, Soong-Hyuck;Rho, Seung-Baik;Lee, Seung-Hyun;Ahn, Won-Sool
    • Elastomers and Composites
    • /
    • v.38 no.3
    • /
    • pp.235-242
    • /
    • 2003
  • A vulcanization reaction characteristics of an isoprene rubber (IR)-modified natural rubber/carbon black (NR/CB) composite was studied using in-situ electrical property measuring technique. Since the electrical conductivity of the sample composite would be changed continuously during the vulcanization reaction by rearranging of the carbon black particles within the sample, volume resistivity (${\rho}$) might be obtained as a function or reaction time. A stabilization time ($t_i$), maximum reaction speed time ($t_p$), and volume resistivity at that time(${\rho}_p$) were defined from the data for the Arrhenius analysis. Volume resistivity ${\rho}$ showed a comparatively high value of ${\sim}10^8$ order before the reaction started, and dramatically decreased to be stabilized within $1{\sim}2$ minutes as soon as the reaction started. As the more time elapsed, thereafter, ${\rho}$ decreased monotonously to a certain constant value through a peak, ${\rho}_p$ at time $t_p$, which was considered as the maximum reaction rate. As a result, while $t_i$ values were comparatively constant as $1{\sim}2$ minutes, $t_p$ values showed to become shorter and shorter as the reaction temperature.

A Study on Flow Induced Vibration of Cantilever Plate with Angle of Attack (받음각을 갖는 평판보의 유동 여기진동에 관한 연구)

  • 이기백;손창민;김봉환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.1919-1932
    • /
    • 1991
  • Experimental studies are conducted to investigate the Flow-Induced Vibration mechanism for cantilever plate model with the angle of attack (.alpha.=10.deg., 20.deg., 30.deg.). Research is divided into two parts. First, the flow fields around two dimensional flat plate model are investigated using LDV system. Second, the vortex shedding frequency and response spectra of cantilever plate are obtained experimentally using gap sensor and hot wire anemometer. Finite element method program was used in order to predict the flow field and pressure field around thin flat plate. And some predicted results were compared with the experimental data. The aspect ration of test model is d/t=25 (d; width, t; thickness). From the measurement of the flow field it was found that in the case of small inclined (.alpha.=10.deg., 20.deg.) relatively, the separated boundary layer at sharp leading edge developed smoothly downstream. With increasing the angle of attack of the plate, stagnation region was appeared on the back side of the plate and separated boundary layer was extended downstream. These trends are a good agreement with the computational results. It was found by analysis of response spectra of cantilever plate that the influences of vortex shedding frequency were important at the large of attack (.alpha.=30.deg.), and two peak values appear in entire test model at 24Hz, 150Hz.

Design of $H_{\infty}$Controller for the inverted pendulum system (도립진자 시스템의 $H_{\infty}$ 제어기 설계)

  • Seo, Kang-Myun;Kang, Moon-Sung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.10
    • /
    • pp.1796-1803
    • /
    • 2006
  • This Paper describes a systematic method for designing the $H_{\infty}$ controller for the inverted pendulum which is a nonlinear and single-input double-outputs system. In particular, the open-loop system is conbined with a pre-filter to shape the open-loop transfer function for the sensitivity function ind the complementary sensitivity function to be kept the desirable frequency characteristics. Consequently, the loop shaping technique of the open-loop transfer function reduces the impacts of the model uncertainties, measurement noises and exogenous disterbances on the dynamic characteristics of the inverted pendulum. The results of simulation and experiment show the efficiency of the proposed control method comparing with conventional PID control method.

Aeroelastic Behaviors of Self-anchored Suspension Bridge with Lateral Sag of Main Cable(II) - Focused on the Behavior of Tower - (횡방향 새그를 가진 자정식 현수교의 공탄성 거동(II) - 주탑의 거동을 중심으로 -)

  • Kwon, Soon Duck;Chang, Sung Pil
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.2 s.31
    • /
    • pp.269-275
    • /
    • 1997
  • Wind tunnel test results and their interpretations, which were performed to study the aerodynamic stability of tower of self-anchored suspension bridge, are presented in this paper. Tower and full models were tested under smooth and turbulent flow conditions. In the case of the tower with inclined two columns, the vibration due to wakes were occurred at wide velocity zone because the wakes with various frequencies were generated by inclined upstream column. It has to be emphasized that the vibration characteristics of the tower in the self-anchored suspension bridge may be very sensitive to the longitudinal boundary conditions of the girder at the supports. Because of the two natural frequency of the tower, out-of-plane bending and torsional, were not well separated, coupled motions were observed in a wide range of wind velocity. The effectiveness of corner cut, countermeasure to reduce the tower vibrations, was also studied. It has been found that 1:10, comer cut size to column width, may be the most effective ratio for reducing the vibrations.

  • PDF

The fabrication of a slanted IDT Transducer for the passband filter (경사진 빗살무늬 변환기를 이용한 대역통과 필터 제작)

  • You Ilhyun;Kwon Heedoo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.2
    • /
    • pp.307-315
    • /
    • 2005
  • We have studied to obtain the SAW filter for the passband was formed on the Langasite substrate and was evaporated by Aluminum-Copper alloy and then we performed computer-simulated by simulator. We can fabricate that the block weighted type IDT as an input transducer of the filter and the withdrawal weighted type IDT as an output transducer of the filter from the results of our computer-simulation. Also, we have performed to obtain the properly design conditions about phase shift of the SAW filter for WCDMA. We have employed that the number of pairs of the input and output IDT are 50 pairs and the thickness and the width of reflector are 5000$\AA$ and 3.6$mu$m, respectively. Frequency response of the fabricated SAW filter has the property that the center frequency is about 190MHz and bandwidth at the 3dB is probably 8.2MHz. And we could obtain that return loss is less then 16dB, ripple characteristics is probably 4dB and triple transit echo is less then 18dB after when we have matched impedance.

A Study on AC Modeling of the ESD Protection Devices (정전기 보호용 소자의 AC 모델링에 관한 연구)

  • Choi, Jin-Young
    • Journal of IKEEE
    • /
    • v.8 no.1 s.14
    • /
    • pp.136-144
    • /
    • 2004
  • From the AC analysis results utilizing a two dimensional device simulator, the ac equivalent-circuit modeling of the ESD protection devices is executed. It is explained that the ac equivalent circuit of the NMOS protection transistor is modeled by a rather complicated form and that, depending on the frequency range, the error can be large if it is modeled by a simple RC serial circuit. It is also shown that the ac equivalent circuit of the thyristor-type pnpn protection device can be modeled by a simple RC serial circuit. Based on the circuit simulations utilizing the extracted equivalent circuits, the effects of the parasitics in the protection device on the characteristics of LNA are examined when the LNA, which is one of the important RF circuits, is equipped with the protection device. It is explained that a large error can result in estimating the circuit characteristics if the NMOS protection transistor is modeled by a simple capacitor. It is also confirmed that the degradation of the LNA characteristics by incorporating the ESD protection device can be reduced a lot by adopting the suggested pnpn device.

  • PDF

음성통신을 위한 잡음처리 기술

  • Sin, Jong-Won;Jang, Jun-Hyeok;Kim, Nam-Su
    • Information and Communications Magazine
    • /
    • v.24 no.4
    • /
    • pp.27-35
    • /
    • 2007
  • 음성 통신을 할 때 배경 잡음이 존재하게 되면 일반적으로 음질이 저하된다. 이것은 잡음 자체가 듣기 싫다거나 음성을 더 작게 들리게 만들기 때문이기도 하고 음성 코덱이 잡음이 섞이지 않은 깨끗한 음성에 최적화되어 있어서 잡음이 섞인 음성에 대한 코딩 효율이 떨어지기 때문이기도 하다. 이 논문에서는 잡음에 의한 음성 통신의 품질 저하를 막기 위한 방법으로서 음성 향상(speech enhancement) 기술과 음성 강화(speech reinforcement) 기술에 대해 소개한다. 음성 향상 기술이란 전송부의 마이크에서 녹음된 잡음과 음성이 섞인 입력 음성으로부터 깨끗한 음성을 추정하는 기술을 말한다. 음성 향상 기술은 상당히 오랜 기간 동안 연구되어 온 기술이며, 최근에는 각 파라미터의 분포에 의존하는 방법보다 확률 모델에 기반한 방법이 각광을 받고 있으며 인간의 청각 특성을 고려한 음성 향상 방법도 제안되고 있다. 음성 강화 기술이란 수신단에서 주변 잡음에 따라 전송되어 온 음성을 주파수별로 증폭하여 더 잘 들리도록 만드는 기술이다. 음성 향상이 내 주위의 잡음이 상대방에게 들리는 음성에 미치는 영향 혹은 상대방 주변의 잡음이 나에게 들리는 소리에 미치는 영향을 줄여주는 기술이라면 음성 강화는 내 주위의 잡음이 나에게 들리는 음성에 미치는 영향을 상쇄해 주는 기술이다. 이 경우 주변 잡음은 어떤 전자 시스템도 거치지 않고 귀로 직접 들어오기 때문에 잡음 자체를 줄여 주는 것은 힘들고 전송되어 온 음성을 적절히 증폭 혹은 변형함으로써 귀에 들리는 음질 또는 명료성을 개선하게 된다. 이 논문에서는 통계 모델을 기반으로 한 음성 향상 기법과 인간의 청각 특성을 고려한 음성 향상 기법, 그리고 음성 강화 기법에 대해 설명한다.을 시도한 결과 안정적이고 반복 가능한 급성 심부전 모델을 얻을 수 있었다. bench scale실험결과와 같이 AOC는 배수관망에서의 박테리아 증식과 크게 상관관계를 갖고 있는 것으로 밝혀졌다.)', 'have a headache (2.10±0.79)', 'poor memory (2.09±0.83)', 'no appetite (1.99±0.85)', As for the correlation between iron parameter and clinical symptoms related to anemia, the hematocrit rate was negatively correlated with 'get a cold easily', 'pale face', 'feeling blue', 'difficult digestion' (p<0.05). The level of iron was negatively correlated with 'tired out easily', 'get a cold easily' (p<0.05) and TS (%) were negatively correlated with 'tired out easily (p<0.05)', 'get a cold easily (p<0.01). Our study resulted that the prevalence of a iron deficiency of a middle school girl is very high, therefore the guidelines for iron supplementation and nutritional education to improve their iron status should be provided.한 질소제거를 N-balance로부터