• Title/Summary/Keyword: 시공성개선

Search Result 777, Processing Time 0.026 seconds

A Study on Field Change Case of Tunnel Concrete Lining Designs Using GLI(Ground Lining Interaction) Model (GLI(Ground-Lining Interaction)모델을 이용한 터널 콘크리트라이닝의 현장 설계변경 사례에 대한 연구)

  • Chang, Seok-Bue;Lee, Soo-Yul;Suh, Young-Ho;Yun, Ki-Hang;Park, Yeon-Jun;Kim, Su-Man
    • Tunnel and Underground Space
    • /
    • v.20 no.1
    • /
    • pp.58-64
    • /
    • 2010
  • GLI model was verified to consider the interaction between a ground and a tunnel lining and to rationally reduce the ground load acting on the secondary lining(concrete lining) of a tunnel. In this study, the economy and the construction condition of tunnel concrete linings designed by a conventional frame model at Lot O of OO line were highly enhanced through a field design change using GLI model. For a few safe considerations, not only about 50% saving of reinforcing steel could reduce the material cost but also the wide space between bars could make it easy to pour concrete mix without voids. There was large saving effect of reinforcing steel for poor ground conditions because Terzaghi's load used in the conventional frame model produces too much high loads for those conditions.

Performance Test of Corner Rigid Joint for Modular Structure using Channel and Coupler (채널과 커플러를 사용한 모듈식 구조체 우각부 연결구조의 성능검증 실험)

  • Lee, Jun-Kyoung;Lee, Jong-Soon;Lee, Sung-Hyung;Kim, Hee-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2255-2262
    • /
    • 2015
  • Recent study about near-surface is proposed to overcome non-economic of underground railway and to reduce people's complaints of ground elevated railway. In this report, precast modular structure system replacing temporary facilities is applied to ensure the construction ability and economic feasibility. To verify the performance of connection joint between permanent structural wall and upper slab, loading test is carried out. As a result of the test, wall replacing temporary structure to slab connection is possible to transfer bending moment. By 30% increase of bending resistant performance for connection joint using coupler, coupler connection joint is more advantageous to resist bending moment compared to channel connection.

Early-Age Behavior Monitoring of Bus-Stop-Section Pavement Constructed Employing Precast Concrete Pavement Method (조립식포장 공법을 적용한 버스정거장 포장 초기 거동 추적조사)

  • Oh, Han-Jin;Kim, Seong-Min;Hwang, Ju-Hwan;Park, Won-Joo
    • International Journal of Highway Engineering
    • /
    • v.13 no.1
    • /
    • pp.229-237
    • /
    • 2011
  • This study was conducted to investigate the early-age performance of precast pavements constructed by replacing existing asphalt pavements for a bus stop section in urban bus only lanes. The behavior monitoring items included the differences in the levels between asphalt and precast pavements at the entrance and exit of the precast pavement, joint widths and level differences between precast slabs, slab settlement, and skid resistance at the slab surface. The applicability of diamond grinding techniques was also investigated. The results of this study showed that the slab level, joint width, settlement, and skid resistance were not much changed as time passed, which implied that the precast pavements stably sustained vehicle loads. It was also found that employing diamond grinding could much improve the leveling between precast slabs and the surface skid resistance.

Comparison of Behaviors for Underground Flexible Pipes with Installation Gap (관로 이격거리에 따른 지중매설관의 거동특성 비교)

  • 이대수;상현규;김경열;홍성연
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.79-87
    • /
    • 2003
  • Underground flexible pipes for electric cables are subject to external loads and surrounding soil pressure. Particularly, strain of flexible pipes is of great concern in terms of safety and maintenance of electric cables. In this paper, stress and strain of flexible pipes with two types of installation gap, ie, l0cm and naught, were compared to investigate the structural integrity of pipes from actual field test. The effect of degree of compaction and burial depth were also investigated to simulate the variety of construction situation. The results of the field test show that the strain criteria were satisfied under the burial depths of 80cm, 100cm and 120cm regardless of installation gap.

Evaluation of Structural Performance of Precast Modular Pier Cap (프리캐스트 모듈러 피어캡의 구조성능 평가)

  • Kim, Dong Wook;Shim, Chang Su
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.1
    • /
    • pp.55-63
    • /
    • 2015
  • Prefabrication technologies are making bridge construction safer and less disruptive to the environment and traveling public, making bridge designs more constructible and, improving the quality and durability by shifting site work to a more controllable environment. Modular bridge substructures with concrete-filled steel tube (CFT) piers and composite pier caps were suggested to realize accelerated bridge construction. The precast segmental pier cap consists of a composite pier table and precast prestressed segments on the table. The pier table has embedded steel section to mitigate stress concentration at the connection by small tubes. Each bridge pier has four or six CFT columns which connect to the pier cap. Shear strength of the pier cap was obtained by extending vertical reinforcing bars from the table to the precast segment. Transverse prestressing was introduced to control tensile stresses by service loadings. Structural performance of the proposed modular system was evaluated by static tests. Design requirements of the composite pier cap were satisfied by continuous reinforcing bars and prestressing tendons. Standardized modular substructures can be effectively utilized for the fast replacement or construction of bridges.

A Study on the Invigoration of BIM Design of Public Institutions : Focused on the Case of LH (공공기관의 BIM 설계 활성화 방안 연구: LH 사례를 중심으로)

  • Yang, Dong-Suk;Lee, Ji-Eun
    • Land and Housing Review
    • /
    • v.7 no.4
    • /
    • pp.291-297
    • /
    • 2016
  • Recently, foreign construction companies through the BIM-design have the effect of improving productivity and quality construction. On the other hand, domestic BIM-design is a little depressed because of lack of additional costs and professional personnel problem. The construction industry of recession, as reasons of construction market is downsizing. First must, enabling the design in public institutions, mainly BIM.. Design for BIM the construction sector, as well as an early stage actively introducing and spreading of the performance of him and domestic BIM technology should be able to promote the development. Public institutions in accordance with this study presented measures that can stimulate the BIM design on LH. To that end, the public agency's design were analyzed, and suggested the Improvement and Application of the four aspects for Modular Coordination BIM Design. Also, gradually formulate a "road map for public institutions applied design bim" in order to carry out the plans put forward and presented the expected effect of him. The proposed work was public institutions will be used as a pilot project in Korea Land Housing Corporation.

Application of Pay Adjustment Regulation for Highway Flexible Pavements (도로 포장의 초기상태에 따른 공사비 차등지급규정의 시험적용)

  • Seo, Young-Guk
    • International Journal of Highway Engineering
    • /
    • v.11 no.3
    • /
    • pp.111-120
    • /
    • 2009
  • Recently, pay adjustment regulation (PAR) has been developed to induce better performing road pavements around the country. This regulation was successfully applied during rehabilitation of highway flexible pavements for the first time, and their results are the focus of this paper. For highway pavements, a lot has been defined by typical amount of works a day. This lot was further divided into several sublots depending on field conditions. According to AASHTO Quality Assurance Guide Specification, pay factors for each lot were statistically determined with field measurements of five performance indicators. And composite pay factors were calculated by accounting for the impact of individual performance indicators on a long-term performance of pavement. In 2008, the PAR was tested with asphalt overlays conducted at all six local headquarters of Korea Expressway Corporation. Also, concerns raised during implementation are discussed in this paper. Limited data used in this study showed that if all performance indicators fall within the construction limits with less variances final construction costs may increase by 50%, whereas 10% reduction in construction costs could be necessary if key performance indicators such as density do not meet the construction quality requirements.

  • PDF

A Study on the Prevention for Differing Site Conditions Claims - Focused on Design-Build Project in Public Sector - (현장여건상이로 인한 클레임의 예방에 관한 연구 -공공부문의 설계$\cdot$시공일괄공사를 중심으로-)

  • Chung Myung-Woo;Lee Hwa-Young;Seo Yong-Chil;Hyun Chang-Taek
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.46-53
    • /
    • 2001
  • Differing Site Conditions('DSC') Claims among construction claims are on the increase as a direct result of the steady construction of Social Overhead Capital Facilities initiated by Government. As DSC claims generally became apparent during the intial stage of the construction project, it is necessary to timely review and study the proposal on the prevention of DSC claims because delayed settlement will incur more substantial damages to all parties concerned. This research is focused on the identification and analysis of the causes for DSC claims as applicable to design-build project in public sector and it presents the possible short term, medium and long term proposals on the improvement of causes related with DSC claims. The major results of this research are summarized as follows: 1. Improvement of contractor's tender practice 2. Contractor's division of responsibility on the site survey 3. Improvement of owner's exculpatory clause 4. Flexibility on the adjustment of contract amount The proposals stated above could be useful in resolving the DSC claims between owner and contractors.

  • PDF

An Analysis and Improvement of Progress Payment Regulations in Korea Using System Dynamics - Focusing on Public Construction Industry - (시스템다이내믹스를 이용한 국내 기성금 제도 현황 분석 및 개선방안 제시 - 공공건설분야를 중심으로 -)

  • Park, Moon-Seo;Lee, Jeoung-Hoon;Lee, Hyun-Soo;Hwang, Sung-Joo;Kim, Soo-Young
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.1
    • /
    • pp.148-159
    • /
    • 2012
  • Recently construction companies' capital condition has been aggravated due to low profit, fierce competition and market contraction. For this reason, the companies rely on public construction projects that protect construction fee by regulations. Despite these regulations, problems regarding progress payment are constantly happening. Also, insufficient analysis on interaction between contractors makes policy making difficult. Thus, in this study, interaction between contractors are quantitatively determined according to delay of application and payment based on current public construction regulations on construction stage. A system dynamics model is used, which analyzes the problems based on an interaction between contractors, and solutions for progress payment application and payment delay are suggested according to the research results.

Experimental Study for Consolidation by Electric Heating Systems (전기가열장치를 이용한 압밀촉진에 관한 실험적 연구)

  • Park, Min-Cheol;Im, Eun-Sang;Lee, Kum-Sung;Han, Heui-Soo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.10
    • /
    • pp.43-53
    • /
    • 2012
  • This study deals with the conventional consolidation methods like preloading and vertical drains. For it, Two different mechanism, i.e., increasing of permeability and evaporating of pore water were studied. The marine clays excavated in Incheon were heated at low temperature($90^{\circ}C$) to increase the permeability. Also, Microwave oven and high-temperature electric heater were used for pore water evaporation. Several points raised from the experiments. To fix them, the electric heating system was revised to upgrade the field application and drain efficiency of pore water, and the marine clays were heated by revised electric heater at high temperature($250^{\circ}C$). From Experimental result showed that results, high-temperature heater induced the pore water evaporation and displayed the excellent consolidation behavior. In addition, the cone index of heated clays were increased about 19 times, which suggested that electric heating system could be applied for ensuring the trafficability of heavy equipments.