• Title/Summary/Keyword: 시공기준

Search Result 1,516, Processing Time 0.032 seconds

Permissible Criteria of the Stiffness of Lightweight Wall by the Horizontal Static Load (정적 수평하중에 의한 경량벽체의 최대변형량 허용기준에 관한 연구)

  • Song, Jung-Hyeon;Kim, Ki-Jun;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.204-205
    • /
    • 2014
  • Among common test methods of assessing structure safety for existing lightweight walls, the criteria of the quality assessment of the horizontal static load resistance has been considered ambiguous. In the current study, therefore, an experiment was conducted to figure out the standardized assessment criteria of the lightweight wall's horizontal static load resistance. Based on the findings of the experiment with gypsum board and ALC block walls, an acceptable amount of each standard and the variables of the stud wall arising from the appropriate load (1000N) on the wall in a daily life were accounted for, arbitrarily setting the maximum deformation amount below 15mm.

  • PDF

Development of the Optimum Condition for Improving Retroreflection of Road Markings (노면표시 반사성능 향상을 위한 최적 조건 개발)

  • 여운웅
    • Proceedings of the KOR-KST Conference
    • /
    • 1998.10a
    • /
    • pp.342-351
    • /
    • 1998
  • 노면표시는 운전자에게 시선유도와 각종 규제 및 지시에 대한 정보를 제공함으로써 교통안전 및 소통에 도움을 주는 시설로써 주야간의 시인성 확보가 중요하며 이를 위해서는 반사화가 필요하다. 노면표시의 반사성능은 유리알 (Glass Bead)의 함량 및 종류, 용융온도, 도료의 색도등 각 영향인자에 의해 결정되지만 현재는 시공법 및 관련 연구의 미흡으로 현행기준의 최하수준을 상회하는 정도로 제공되고 있다. 따라서 본 연구에서는 노면표시의 시공에 관계되는 각 요인중 반사성능가 내구성에 영향을 미치는 주요인자 및 반사성능을 최적화하기 위한 인자별 최적조합을 도출하였다. 연구결과 유리알 살포량이 중량비로 25%-30%, 용융시 온도가 $188^{\circ}C$$\pm$$10^{\circ}C$일 때 노면표면시의 반사성능이 최적화됨을 밝혀내었다. 또한 유리알의 품질개선과 함께 황색 노면표시의 재귀반사 휘도계수 기준을 현재 기준보다 상향조정할 필요성이 있음을 제안하였다.

  • PDF

Safety Diagnosis & Rainforced Countermeasure in Steel Tower (해원철탑 안전진단과 보강대책방안)

  • Park, Won-Chul;Lee, Jae-Kwan
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.819-821
    • /
    • 1997
  • 경제발전에 따른 국민 생활향상과 산업고도화에 의해 전력은 계속하여 수요가 증가하고 대용량화 되어가고 있으며 그와 함께 지속적이고 안정된 전력공급은 그 중요성이 더욱 대두된다. 서남해안 도서지역은 전력수요가 96년대에는 13.5%증가하였으며 전선로의 설비는 가공해월청탑과 해저케이블, 공급방식은 수지상식의 취약선로이다. 폭풍이나 태풍에 의해 해월청탑의 도괴된 사례가 발생하여 가공송전선을 설계 기준중 기준풍속을 지역별로 구분, 상향조정(87.6)되었으며 기존 해월청탑 설비에 대한 안정성 검토의 필요성이 대두되었다. 태풍 또는 폭퐁에 의한 해월청탑 지지물의 도괴, 또는 파손 등의 피해를 방지기존철탑 및 기초안전도를 검토하고 보강필요시 우리 실정에 맞는 경제적이고 안정된 보강방범 및 공법을 연구 개발하여 이에 의한 설계 및 시공기준을 수립하고자 한다.

  • PDF

연구원_연구과제 ③ - 기계설비공사 시공상세도 작성비 산정의 문제점 및 개선방안

  • O, Chi-Don;Lee, Yeong-Jun
    • 월간 기계설비
    • /
    • s.308
    • /
    • pp.44-45
    • /
    • 2016
  • 대한기계설비산업연구원(원장 이언구)은 지난해 4월 연구심의위원회에서 선정된 ${\triangle}$기계설비건설업 동향분석 ${\triangle}$기계설비건설업체의 부도예측 모형 연구 ${\triangle}$기계설비건설공사 시공상세도면 작성비 산정기준 연구 ${\triangle}$플랜트 건설 현장 외국인력 고용 개선방안 ${\triangle}$녹색기술 기준에 근거한 연구과제 도출을 위한 기초연구 ${\triangle}$대용량 지열설비 이용을 위한 지중열교환기 용량 설계 툴 개발 ${\triangle}$기계설비배관 및 장비 단열 기준 연구 등의 기본과제와 외부기관과 공동으로 수행한 ${\triangle}$플랜트 건설현장 외국인력 고용 개선방안 ${\triangle}$기계설비건설업 관련법류 개선방안 연구를 추진했다. 본지는 지난 2월호부터 연구결과 요약 보고서를 연재하고 있다.

  • PDF

Examining and Refining the Code for Durability Design Criteria of Concrete Carbonation (개정 콘크리트 탄산화 내구성 설계기준의 적용상 문제점 분석)

  • Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.3
    • /
    • pp.285-293
    • /
    • 2023
  • In this research, we embarked on a meticulous analysis of the challenges inherent in real-world scenarios relating to the durability design standards of engineered concrete structures and the assessment of carbonation durability in concrete guidelines. Our investigation brought to light substantial issues concerning constructability and quality assurance. The genesis of these problems is the exclusive application of prescribed strength to exterior walls, neglecting other elements to facilitate smoother licensing procedures. While this methodology aims to mitigate financial constraints in alignment with enhanced standards, it invariably invites complications. Furthermore, it is imperative to resolve the uncertainty surrounding durability evaluations by establishing a clear and definitive objective. Alongside this, actionable steps must be formulated to forestall the emergence of fissures between the floors of residential buildings, particularly apartment complexes. It is equally essential to tackle issues connected to application by devising a comprehensive management strategy for potential cracking during the phase of maintenance.

A Study on Rational Design and Construction of High-Tension-Bolt Friction Joints (고장력볼트 마찰이음의 합리적 설계 및 시공에 관한 연구)

  • Lee, Seung Yong;Kyung, Kab Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3A
    • /
    • pp.513-521
    • /
    • 2006
  • Many studies have been conducted on the high tension bolt friction connection in the view of the field practice. Those effort, however, unfortunately have not been appropriately applied in the design specifications. Recently, particularly for steel bridges, rationalization of design takes greater attention from designers and hence, demand on rationalization of high tension connection becomes more significant. The purpose of this study is to suggest direction for the rationalization of high tension bolt connection and to also provide fundamental information for the improvement of the design specifications. In order to accomplish the purposes, the design specifications in Korea was analyzed and compared with other specification from abroad, and was studied one of the most important factors including slip coefficient, and the specifications on the size of bolt holes. The effect of over-sized bolt hole and the reduction of axial force on bolt was evaluated through the experimental studies on the slippage of the high tension bolt connections. Other research topics included herein includes the difference of slip coefficients, the effect of over-sized bolt holes and the gap distance of members, and the application of filler plate and corrosion protected bolts. From the research results, it is known that the specifications in Korea apply a constant slip coefficient with respect to the contacted surface conditions while various coefficients are available depending on the contacted surface conditions. Therefore, it is recommended that the specifications in Korea also develop and detail the slip coefficient which can appropriately take account of the variation of the contacted surface conditions. It is also suggested that the limitation abroad on the over-sized bolt hole may be applied for enhancing the effectiveness of construction.

Proposal of BIM Quality Management Standard by Analyzing Domestic and International BIM Guides (국내외 BIM가이드 분석을 통한 BIM 품질관리기준의 제안)

  • Kwon, O-Cheol;Jo, Chan-Won
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.3
    • /
    • pp.265-275
    • /
    • 2011
  • As BIM is now being accepted and broadly expanded in the building industry, the demand for developing, managing, submitting, and checking the BIM models has increased. To meet this demand, it is necessary to develop and spread BIM guidelines, standards, and manuals. Meanwhile, as the number of public construction projects increases, the importance of quantifying the BIM quality checking and evaluation also grows. This study aims to enhance our understanding of the definition and characteristics of BIM quality management, and review the current situation of BIM standards worldwide. In particular, by focusing on BIM quality control and its relevant subjects, the minimum standards for BIM quality management are suggested.

Development of Model Requirements Checklist for Utilizing BIM in Construction Phase - Focused on the MEP - (시공단계 BIM 활용을 위한 모델 요구조건 체크리스트 개발 - MEP를 중심으로 -)

  • Kim, Woojin;Park, Jinho;Cha, Yongwoon;Hyun, Changtaek;Han, Sangwon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.1
    • /
    • pp.22-31
    • /
    • 2019
  • The application of BIM that can manage and integrate information generated during the entire life cycle of buildings in domestic and overseas construction projects is becoming active. When BIM is utilized in the construction phase, it can shorten the construction period, reduce the occurrence of reworks and improve collaboration capability. However, there are limitations in applying BIM to the construction phase due to the insufficient definition level of domestic BIM guidelines and inadequate design standards. In this regard, this study developed BIM model requirements checklist for the application of BIM in the construction phase. To develop the checklists, 21 domestic and overseas BIM guidelines, three public construction projects and four private construction projects to which construction BIM was applied, were analyzed. Based on the guidelines and cases, a total of 62 construction BIM model requirements (31 model objects and 31 attribute rules) and proposed construction BIM model requirement checklists by dividing the 61 requirements according to the requirement and purpose for utilization were identified. It is expected that the practical applications of the checklists proposed in this study will improve the level of BIM model in construction phase. In addition, this study has its significance as a basic research that can be used in the development of standardized guidelines for BIM model in construction phase from academic aspects.

An Experimental Study on Sidewalk on the Bridge Bracket Section to Optimize (교량 보도부 브라켓 단면의 최적화를 위한 실험적 연구)

  • Park, Sungrak;Oh, Hongseob;Nam, Kiwook
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.158-158
    • /
    • 2011
  • 통상 교량구조물은 차도부와 보도부 및 그 부속시설로서 난간 및 연석부 등으로 구성되는데, 자동차 전용도로의 경우 보도부가 설치되지 않게 되고, 국내의 국도 및 지방도상의 많은 교량이 차도부와 보도부의 별도의 구분이 없이 보행자가 연석부 위로 통행하거나 여의치 않을 경우 난간에 기대어 통행하는 경우가 일반적이어서 안전사고의 위험에 직접 노출되는 경우가 많다. 이에 국토해양부에서는 최근 "도로의 구조 및 시설기준에 관한 규칙"을 개정하여 국내의 보행자 관련 교통사고로 인한 사망자가 전체 교통사고 사망자의 약 절반을 차지하는 실정을 고려하여 보행자의 안전한 통행로 확보를 통해 보행공간의 근본적인 개선이 불가피한 실정임을 시사 하였다. 이에 국내에서는 교량 보도부의 확장에 대한 관심이 높은 실정이며, 현재 보도부 확장에 대한 시공이 활발하게 이뤄지고 있다. 그러나 기존 교량에 보도부를 신설 혹은 확장함에 있어서 보도부 부재의 설치 간격 및 필요한 앵커볼트의 수량 및 부재의 성능 평가에 대한 기준이 명확하게 이뤄지지 않은 상태에서 설치되어져 왔었다. 기존에 시공되던 H-형강의 브라켓 단면의 경우 브라켓 단면의 중량이 커서 안정성 및 시공성이 떨어지며 과다한 앵커볼트의 체결 및 브라켓 단면의 과다설계로 인한 공사기간 및 비용의 증대를 가져오는 문제점이 있었다. 이에 본 연구에서는 교량 보도부의 확장 및 신설에 있어서 보도부 부재의 설치간격의 적정성 및 브라켓의 최적화를 위한 브라켓의 성능평가 시험을 수행하였다. 브라켓의 성능평가 시험은 1차 2차 3차 시험으로 나누어 진행되었으며, 1차시험은 H-형강의 브라켓단면을 원형강관으로서의 대체 가능성을 확인하였고, 2차 시험에서는 원형강관의 브라켓 단면의 앵커볼트수량의 최적화에 대한 시험을 수행하였으며, 3차 시험은 최적화된 브라켓 단면에 프리스트레싱의 도입으로 반력 및 인발력의 감소효과를 확인하는 연구를 수행하였다. 본 연구의 수행결과 기존의 설계 및 시공방법이 과다 설계가 이뤄졌음을 판단하였고, 브라켓 단면의 최적화를 통하여 기존 시공방법에 비해 시공성, 안전성, 경제성을 높일수 있을 것으로 판단된다.

  • PDF

A Case Study on Behavior of High-Raised Reinforced Soil Wall (고성토 보강토옹벽의 거동에 관한 사례연구)

  • Cho, Sam-Deok;Lee, Kwang-Wu;Lee, Hoon-Yeon;Chang, Ki-Soo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.5 no.4
    • /
    • pp.35-42
    • /
    • 2006
  • This paper describes a field experience on geogrid-reinforced soil walls rising up to 29.5m in height. Since experiences of design and construction on very high-raised geogrid reinforced soil wall were limited, thorough design and construction management was performed for safe construction of the wall. Regarding design of the wall, both internal and external stabilities were examined based on the design guideline specified by FHWA and overall slope stability analyses were performed by using Bishop simplified method. Moreover, a series of instrumentations were performed. The results of instrumentation for two tiered reinforced soil wall showed that not only the deformations of both the wall face and the reinforcement but also the horizontal earth pressures acting on the wall facing were very small. These results indicate that the reinforced soil wall technology can be applied successfully for high-raised tiered wall more than 20m heights and FHWA design guideline is very conservative for that large wall.

  • PDF