• Title/Summary/Keyword: 시간정확도

Search Result 2,795, Processing Time 0.045 seconds

Development of 2.5D Electron Dose Calculation Algorithm (2.5D 전자선 선량계산 알고리즘 개발)

  • 조병철;고영은;오도훈;배훈식
    • Progress in Medical Physics
    • /
    • v.10 no.3
    • /
    • pp.133-140
    • /
    • 1999
  • In this paper, as a preliminary study for developing a full 3D electron dose calculation algorithm, We developed 2.5D electron dose calculation algorithm by extending 2D pencil-beam model to consider three dimensional geometry such as air-gap and obliquity appropriately. The dose calculation algorithm was implemented using the IDL5.2(Research Systems Inc., USA), For calculation of the Hogstrom's pencil-beam algorithm, the measured data of the central-axis depth-dose for 12 MeV(Siemens M6740) and the linear stopping power and the linear scattering power of water and air from ICRU report 35 was used. To evaluate the accuracy of the implemented program, we compared the calculated dose distribution with the film measurements in the three situations; the normal incident beam, the 45$^{\circ}$ oblique incident beam, and the beam incident on the pit-shaped phantom. As results, about 120 seconds had been required on the PC (Pentium III 450MHz) to calculate dose distribution of a single beam. It needs some optimizing methods to speed up the dose calculation. For the accuracy of dose calculation, in the case of the normal incident beam of the regular and irregular shaped field, at the rapid dose gradient region of penumbra, the errors were within $\pm$3 mm and the dose profiles were agreed within 5%. However, the discrepancy between the calculation and the measurement were about 10% for the oblique incident beam and the beam incident on the pit-shaped phantom. In conclusions, we expended 2D pencil-beam algorithm to take into account the three dimensional geometry of the patient. And also, as well as the dose calculation of irregular field, the irregular shaped body contour and the air-gap could be considered appropriately in the implemented program. In the near future, the more accurate algorithm will be implemented considering inhomogeneity correction using CT, and at that time, the program can be used as a tool for educational and research purpose. This study was supported by a grant (#HMP-98-G-1-016) of the HAN(Highly Advanced National) Project, Ministry of Health & Welfare, R.O.K.

  • PDF

Radiation Dose during Transmission Measurement in Whole Body PET/CT Scan (전신 PET/CT 영상 획득 시 투과 스캔에서의 방사선 선량)

  • Son Hye-Kyung;Lee Sang-Hoon;Nam So-Ra;Kim Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.89-95
    • /
    • 2006
  • The purpose of this study was to evaluate the radiation doses during CT transmission scan by changing tube voltage and tube current, and to estimate the radiation dose during our clinical whole body $^{137}Cs$ transmission scan and high quality CT scan. Radiation doses were evaluated for Philips GEMINI 16 slices PET/CT system. Radiation dose was measured with standard CTDI head and body phantoms in a variety of CT tube voltage and tube current. A pencil ionization chamber with an active length of 100 mm and electrometer were used for radiation dose measurement. The measurement is carried out at the free-in-air, at the center, and at the periphery. The averaged absorbed dose was calculated by the weighted CTDI ($CTDI_w=1/3CTDI_{100,c}+2/3CTDI_{100,p}$) and then equivalent dose were calculated with $CTDI_w$. Specific organ dose was measured with our clinical whole body $^{137}Cs$ transmission scan and high quality CT scan using Alderson phantom and TLDs. The TLDs used for measurements were selected for an accuracy of ${\pm}5%$ and calibrated in 10 MeV X-ray radiation field. The organ or tissue was selected by the recommendations of ICRP 60. The radiation dose during CT scan is affected by the tube voltage and the tube current. The effective dose for $^{137}Cs$ transmission scan and high qualify CT scan are 0.14 mSv and 29.49 mSv, respectively. Radiation dose during transmission scan in the PET/CT system can measure using CTDI phantom with ionization chamber and anthropomorphic phantom with TLDs. further study need to be peformed to find optimal PET/CT acquisition protocols for reducing the patient exposure with same image qualify.

  • PDF

Relationship between Stomach Volume and Tumor Location in Radiation Treatment for Hepatic Tumors (간 종양의 방사선치료에서 위내용적과 종양 위치 간의 관계)

  • Jeon, Mi-Jin;Lee, Chang-Geol;Lee, Ik-Jae;Choi, Won-Hoon;Choi, Yun-Sun;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Ha, Jin-Suk;Cho, Yoon-Jin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.75-83
    • /
    • 2010
  • Purpose: It aims to evaluate the location change and tendency of hepatic and intrahepatic tumors according to gastric volume and change of location. Materials and Methods: It studied 9 patients with hepatic tumors who visited Gangnam Severance Hospital from March 2009 to April 2010 and who underwent CT or PET (Positron Emission Tomography) within 2 weeks before CT-simulation. The patients fasted for 6 hours before CT-simulation and drank 240~250 cc of water just before CT or PET for image fusion. Those two types of images were fused to RTP (Radiation Treatment Planning, Pinnacle 8.0h) focusing on bone structure of individual patients. Results: They drank 240~260 cc of water but their stomach volume after drinking water varied from 259.3 cc to 495.4 cc. Even though individual differences existed in the change of stomach volume before and after drinking water, the volume was increased by 130 cc (174%) on average. The change in absolute distance between the centers of tumors ranged from 0.52 cm to 3.04 cm (1.52 cm on average); from 0.1 cm to 1.35 cm (0.44 cm on average) in cranial-caudal direction; from 0.05 cm to 2.75 cm (1.22 cm on average) in left-right direction; and from 0.05 cm to 1.85 cm (0.33 cm on average) in ventral-dorsal direction. Conclusion: It is hard to predict the movement of tumors by observing stomach movement, due to great individual differences; however, it was observed that the location of hepatic tumors was right-sided as the stomach was filled with water. Thus, it is recommended to maintain the fastened state to secure the accuracy of hepatic tumor treatment. If it cannot maintain the fastened state, it is recommended to measure stomach volumes and movement in the patient to consider the movement of hepatic tumors before radiation treatment.

  • PDF

The Association of Growth Rate with Body Weight or Shank Length at Birth in Broiler Chickens (육용계의 부하시 체중 혹은 정강이 길이와 성장률과의 상관관계에 관한 연구)

  • Suk Y. O.
    • Korean Journal of Poultry Science
    • /
    • v.31 no.3
    • /
    • pp.157-164
    • /
    • 2004
  • The objective of this study was to investigate the association of growth rate with body weight or shank length at birth in broiler chickens. Cobb and Ross breeds were used as experimental stocks and four groups were assigned in each breed; thirteen-male and twelve-female chicks(25 birds) were allocated in each group. The heavier body weight group(HBW) and the lighter body weight group(LBW) were established by birth weight. Whereas, the longer shank length group(LSL) and the shorter shank length group(SSL) were established by shank length at birth. The heavier group chicks in birth weight were significantly(P < 0.05) the longer in shank length at birth. The differences between HBW and LSL or between LBW and SSL in the mean 5-wk body weight of Cobb were not significantly different in each other; however, HBW and LSL were significantly(P < 0.05) heavier than LBW or SSL. Whereas, there were no significant differences in the mean 5-wk body weight of Ross although HBW was heavier by 13.1 g than LBW and LSL was heavier by 68.0 g than SSL. In the mean 5-wk shank length, the LSL of Cobb and Ross was longer by 2.9 mm and 1.3 mm than SSL, respectively; however, the significant(P < 0.05) difference was showed in Cobb only. In both breeds, the differences in the mean 5-wk shank length between HBW and LBW were not great. By the results of correlation analysis, the associations of the overall mean birth weights with the overall mean shank length at birth or the association of the 0~5 wk growth rate with the change of shank length during 0~5 wk showed highly significant(P < 0.01~0.001) in both breeds. The present study suggested that the selection based on birth weight could be at advantage due to easier and more accurate tool in using for the improvement growth rate in broiler chickens because the measurement of shank length takes individually longer and less accurate than the measurement of body weight.

Predicting the Progression of Chronic Renal Failure using Serum Creatinine factored for Height (소아 만성신부전의 진행 예측에 관한 연구)

  • Kim, Kyo-Sun;We, Harmon
    • Childhood Kidney Diseases
    • /
    • v.4 no.2
    • /
    • pp.144-153
    • /
    • 2000
  • Purpose : Effects to predict tile progression of chronic renal failure (CRF) in children, using mathematical models based on transformations of serum creatinine (Scr) concentration, have failed. Error may be introduced by age-related variations in creatinine production rate. Height (Ht) is a reliable reference for creatinine production in children. Thus, Scr, factored for Ht, could provide a more accurate predictive model. We examined this hypothesis. Methods : The progression of of was detected in 63 children who proceeded to end-stage renal disease. Derivatives of Scr, including 1/Scr, log Scr & Ht/Scr, were defined fir the period Scr was between 2 and 5 mg/dl. Regression equation were used to predict the time, in months, to Scr > 10 mg/dl. The prediction error (PE) was defined as the predicted time minus actual time for each Scr transformation. Result : The PE for Ht/Scr was lower than the PE for either 1/Scr or log Scr (median: -0.01, -2.0 & +10.6 mos respectively; P<0.0001). For children with congenital renal diseases, the PE for Ht/Scr was also lower than for the other two transformations (median: -1.2, -3.2 & +8.2 mos respectively; P<0.0001). However, the PEs for children with glomerular diseases was not as clearly different (median: +0.9, +0.5 & +9.9 respectively). In children < 13 yrs, PE for Ht/Scr was tile lowest, while in older children, 1/Scr provided the lowest PE but not significantly different from that for Ht/Scr. The logarithmic transformation tended to predict a slower progression of CRF than actually occurred. Conclusion : Scr, floored for Ht, appears to be a useful model to predict the rate of progression of CRF, particularly in the prepubertal child with congenital renal disease.

  • PDF

Establishment of PCR Conditions for the Identification of Stenotrophomonas maltophilia Isolated from Boar Semen and Antimicrobial Susceptibility Patterns of the Isolates (돼지 정액에서 분리된 Stenotrophomonas maltophilia 확인을 위한 PCR 기법 개발 및 분리 균주의 항생제 감수성 양상)

  • Jung, Byeong-Yeal;Park, Bum-Soo;Kim, Ha-Young;Byun, Jae-Won;Kim, Ae-Ran;Jeon, Albert Byung-Yun;Kim, In-Cheul;Chung, Ki-Hwa
    • Journal of Life Science
    • /
    • v.22 no.8
    • /
    • pp.1114-1119
    • /
    • 2012
  • Bacteria are frequently contaminated during the collection and processing procedures of boar semen. Of the contaminants, Stenotrophomonas (S.) maltophilia is a Gram-negative bacterium that is widely distributed in a variety of habitats. Although PCR assays have been developed for the detection of S. maltophilia, they cross-react with some species of Xanthomonas. In this study, we designed a primer set for the detection of S. maltophilia in order to target the chiA (GenBank accession no. NC_010943) gene. The specific PCR products were amplified from S. maltophilia only, not from other tested strains that are frequently found in semen. The detection limit of the PCR was $1.5{\times}10^3$ CFU/ml with pure-cultured S. maltophilia and $1.5{\times}10^4$ CFU/ml with S. maltophilia spiked in semen. Twenty-six (5.9%) S. maltophilia were isolated from 440 semen samples. The PCR results exhibited 98.9% agreement with a comparison of S. maltophilia isolation. Also, the sensitivity and specificity of the PCR were 100% and 98.7%, respectively. In the antimicrobial susceptibility test, S. maltophilia isolates were highly susceptible to enrofloxacin and florfenicol, while the majority of them were resistant to amoxicillin/clavulanic acid, apramycin, ceftiofur, penicillin, and spectinomycin. These results indicated that the PCR using the chiA gene was proven to be reliable and effective for the detection of S. maltophilia with high levels of sensitivity and specificity.

Estimation of river discharge using satellite-derived flow signals and artificial neural network model: application to imjin river (Satellite-derived flow 시그널 및 인공신경망 모형을 활용한 임진강 유역 유출량 산정)

  • Li, Li;Kim, Hyunglok;Jun, Kyungsoo;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.7
    • /
    • pp.589-597
    • /
    • 2016
  • In this study, we investigated the use of satellite-derived flow (SDF) signals and a data-based model for the estimation of outflow for the river reach where in situ measurements are either completely unavailable or are difficult to access for hydraulic and hydrology analysis such as the upper basin of Imjin River. It has been demonstrated by many studies that the SDF signals can be used as the river width estimates and the correlation between SDF signals and river width is related to the shape of cross sections. To extract the nonlinear relationship between SDF signals and river outflow, Artificial Neural Network (ANN) model with SDF signals as its inputs were applied for the computation of flow discharge at Imjin Bridge located in Imjin River. 15 pixels were considered to extract SDF signals and Partial Mutual Information (PMI) algorithm was applied to identify the most relevant input variables among 150 candidate SDF signals (including 0~10 day lagged observations). The estimated discharges by ANN model were compared with the measured ones at Imjin Bridge gauging station and correlation coefficients of the training and validation were 0.86 and 0.72, respectively. It was found that if the 1 day previous discharge at Imjin bridge is considered as an input variable for ANN model, the correlation coefficients were improved to 0.90 and 0.83, respectively. Based on the results in this study, SDF signals along with some local measured data can play an useful role in river flow estimation and especially in flood forecasting for data-scarce regions as it can simulate the peak discharge and peak time of flood events with satisfactory accuracy.

The Effectiveness of CT and MRI Contrast Agent for SUV in 18F-FDG PET/CT Scanning (18F-FDG PET/CT 검사에서 정량분석에 관한 CT와 MRI 조영제의 효과)

  • Cha, Sangyoung;Cho, Yonggwi;Lee, Yongki;Song, Jongnam;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.255-261
    • /
    • 2016
  • In this study, among various factors having influence on SUV, we intended to compare and analyze the change of SUV using CT(4 type) and MRI(3 type) contrast agents which are commercialized now. We used Discovery 690 PET/CT(GE) and NEMA NU2 - 1994 PET phantom as experimental equipment. We have conducted a study as follows; first, we filled distilled water to phantom about two-thirds and injected radioisotope(18F-FDG 37 MBq), contrast agent. Second, we mixed CT contrast agent with distilled water and MRI contrast agent with that water separately. And then, we stirred the fluid and filled distilled water fully not to make air bubble. In emission scan, we had 15minutes scanning time after 40 minutes mixing contrast agent with distilled water. In transmission scan, we used CT scanning and its measurement conditions were tube voltage 120 kVp, tube current 40 mA, rotation time 0.5 sec, slice thickness 3.27 mm, DFOV 30 cm. Analyzing results, we set up some ROIs in 10th, 15th, 20th, 25th, 30th slice and measured SUVmean, SUVmax. Consequently, all images mixed 3 types of MRI contrast agent with distilled water have high SUVmean as compared with pure FDG image but there was no statistical significance. In SUVmax, they have high score and there was statistical significance. And other 4 images mixed 4 types of CT contrast agent with distilled water have significance in both SUVmean and SUVmax. Attenuation correction in PET/CT has been executed through various methods to make high quality image. But we figured out that using CT and MRI contrast agents before PET/CT scanning could make distortion of image and decrease diagnostic value. In that reason, we have to sort out the priority of examination in hospital not to disturb other examination's results. Through this process, we will be able to give superior medical service to our customers.

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

The Clinical Value of Dual Time Point F-18 FDG PET/CT Imaging for the Differentiation of Colonic Focal Uptake Lesions (장관 내 국소 섭취증가 병소의 감별에 있어 추가 지연 F-18 FDG PET/CT의 임상적 유용성)

  • Kim, Jin-Suk;Lim, Seok-Tae;Jeong, Young-Jin;Kim, Dong-Wook;Jeong, Hwan-Jeong;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.309-316
    • /
    • 2009
  • Purpose: F-18 FDG can be accumulated in the liver, bowel, kidney, urinary tract, and muscles physiologically. The aim of this study was to evaluate the clinical value of dual time point 18F-FDG PET /8 imaging for the differentiation of the colonic focal uptake lesions. Materials and Methods: One hundred thirty two patients (M:F = 77:55, Age 62.8$\pm$11.6 years) underwent $^{18}$F-FDG PET/CT at two time points, prospectively: early image at 50-60 min and delayed image at 4-4.5 hours after the intravenous injection of $^{18}$F-FDG. Focally increased uptake lesions on early images but disappeared or shifted on delayed images defined a physiological uptake. For the differential evaluation of persistent focal uptake lesions on delayed images, colonoscopy and histopathologic examination were performed. SUVmax changes between early and delayed images were also compared. Results: Among the 132 patients, 153 lesions of focal colonic uptake were detected on early images of $^{18}$F-FDG PET/CT. Of these, 72 (47.1%) lesions were able to judge with physiological uptake because the focal increased uptake disappeared from delayed image. Among 81 lesions which was showed persistent increased uptake in delayed image, 61 (75.3%) lesions were confirmed as the malignant tumor and 14 (17.3%) lesions were confirmed as the benign lesions including adenoma and inflammatory disease. Remaining 6 (7.4%) lesions were confirmed as the physiological uptake because there was no particular lesion in the colonoscopy. In the malignant lesions, the calculated dual time point change for SUVmax ($\Delta$%SUVmax) was 20.8$\pm$18.7%, indicating a significant increase in SUVmax between the two point (p<0.01). In contrast, the change in SUVmax for the non-malignant lesions including benign lesions and physiological uptake was -13.7%$\pm$24.2%. For the differentiation of the malignant and non-malignant focal colonic uptake lesions, $\Delta$%SUVmax was the most effective parameter, and the cut-off value using -5% provided the best sensitivity, specificity, and accuracy. Conclusion: The dual time point $^{18}$F-FDG PET/CT imaging with SUVmax change evaluation could be an important noninvasive method for the differentiation of malignant and benign focal colonic uptake lesions including physiologic uptake.