Optimization of the Passenger Safety Door(PSD) Part using Response Surface Method (반응표면법에 의한 승강장 안전문(PSD) 부재의 최적화)

  • Lee, Jae-Hwan;Kim, Jin-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.1
    • /
    • pp.73-79
    • /
    • 2009
  • In this paper, the structural analysis and optimization of the door supporting rail structure in the header box located at the top of the aluminum passenger safety door(PSD) at the subway station, which opens and closes regularly, is performed. In case the simple fixed boundary condition is used for the bolt fixture on the supporting rail where the glass door is moving, excessive stresses are obtained. Therefore, more realistic finite element modeling of the bolts is used at the bolt fixture in the whole structure in order to obtain the more physically acceptable FEM results. As a result, fatigue life of twenty years of the structure is obtained to satisfy the design object. Also the optimal design of cross section of the rail part is performed using the response surface method and 15% of weight of the supporting rail part on the door is reduced.

A Study on a Elevator Emergency Call Device System and Performance Evaluation based on ICT for Efficient Handling in Emergency Situation (위급상황 시 효율적인 대처를 위한 ICT 기반의 엘리베이터 비상통화장치 시스템 및 성능 비교 연구)

  • Jung, Se-Hoon;Park, Sung-Kyun;Park, Hong-Jun;So, Won-Ho;Park, Dong-Kook;Sim, Chun-Bo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.4
    • /
    • pp.449-459
    • /
    • 2015
  • A lot of people were trapped in elevators without power supply when BLACK-OUT situation occurred in 2011. The telephone network of control room connected to the elevators had problem operating poorly. In this paper we propose an ICT based elevator emergency call device prototype system and evaluate the performance of the system. The proposed system quickly responds in emergency situation to guarantee passenger safety. For the goal, firstly the system tries to connect to a control room. If it fails the system attempts to call numbers for emergency contact and a rescue team sequentially. The system is designed to quickly support emergency contact as well. Finally, the information of elevator failure is rapidly transferred to the failure process device by the proposed system.

A Study on the Improvement of a Damageability and Repairability by Improving Mounting Structure of a Bumper for Passenger Cars (범퍼체결구조 개선을 통한 손상성.수리성 향상방안에 관한 연구)

  • Kim, Ji-Won;Park, In-Song;Lee, Chang-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • The purpose of this study is to analyze the bumper mounting structure of passenger vehicles at low speed collision. In order to improve the repairability and damageability of the vehicle, the low speed crash tests of RCAR(Research Council for Automobile Repairs) standard(front & rear 15km/h 40% offset crash test) were carried out for analysis of 3 different types of bumper mounting structures. The results of experiments show that the impact energy absorbing ability of bumper stay with rectangular crash box type vehicle which is inserted into the bumper rail was superior to another two different bumper mounting structures that are applied to many passenger vehicles. In this thesis, well designed bumper mounting structure such as rectangular crash box type can enhance the safety of occupants as well as contribute to reduce repair cost at low collision accident by improving repairability and damageability of vehicle.

Comparative Studies of Evacuation Time According to the Distribution Characteristics of Training Ship's Personnels (운항실습선 승선자의 분포특성에 따른 대피시간 비교)

  • Hwang, Kwang-Il
    • Journal of Navigation and Port Research
    • /
    • v.35 no.3
    • /
    • pp.213-218
    • /
    • 2011
  • This study simulates and compares the evacuation time and characteristics according to the living patterns on board a training ship which was launched in Dec. 2005, on the viewpoint of the various activities being possible on board a cruise ship. Based on interviews with personnels on board, 3 living patterns are set as representative living conditions; Pattern A(all personnels are positioned at their cabins), Pattern B(all personnels are positioned at lecture rooms, offices or else), Pattern C(all personnels are positioned at restaurant or cafeteria). The simulation results show that Pattern B is comparatively ideal because the evacuation time is short and there is less delay of personnels' movement on each deck. On the contrary, Pattern C is evaluated as the worst because the average evacuation time took more than 360 seconds and the bottle-neck happened at Upper deck. As a result, this study proposes the needs of various countermeasures against the fire and/or disaster, considering the various living patterns on cruiser(s) and/or passenger ship(s).

An Efficient AP Selection Strategy in Wi-Fi based Vechicle-to-Infrastructure Communications (Wi-Fi 기반의 차량과 기지국간 통신에서 효과적인 AP 선택에 관한 연구)

  • Hwang, Jae-Ryong;Lee, Hwa-Ryong;Choi, Jae-Hyuk;Yoo, Joon;Kim, Chong-Kwon
    • The KIPS Transactions:PartC
    • /
    • v.17C no.6
    • /
    • pp.491-498
    • /
    • 2010
  • Wi-Fi based vehicle-to-infrastructure (V2I) communication is an emerging solution to improve the safety, traffic efficiency, and comfort of passengers. However, due to the high mobility of vehicles and the limited coverage of Wi-Fi APs, the V2I system may suffer from frequent handoffs although roadside APs can support cost effective Internet connectivity. Such problem of V2I systems can be overcome with Mobile AP (MAP) platform. The MAPs yield longer service duration by moving along with vehicles, yet they provide a lower link capacities than the roadside APs. In this paper, we propose a new association control mechanism that effectively determines whether the vehicle will select a fixed roadside-AP or a nearby MAP in mobile vehicular network environments. We consider both the achievable link bandwidth and available connection duration as a selection criterion and provide their run-time estimation method. Extensive simulation using real traces show significant performance improvements.

Durability Evaluation on Doorstep Equipments Used for Low and High Level Platforms at Railway Vehicle (철도차량의 저상 및 고상 승강장 겸용 승강문 스텝에 대한 내구성 평가)

  • Kim, Chul-Su;Park, Min-Heung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.3889-3894
    • /
    • 2012
  • The platform of railroad station for domestic passenger train has been operated at two categories like the platforms if low level(500mm, mainline) and high level(1,135mm, metropolitan subway line). To operate both metropolitan subway line and mainline railroad safely, it is essential to develop the doorstep equipment of railway vehicle regardless of low and high level platforms. On the other hand, the domestic test standard at durability and reliability of doorstep equipment has not been existed until now. This study aims at the development on doorstep equipment of telescopic sliding type for low and high level platforms. Durability analysis with VPD(Virtual Product Development) techniques are performed and the durability standard & qualification life through the rig test during no failure test time is examined in accordance with reliability qualification test.

Interior Noise Characteristics of the Electric Trains in Gyeongchun Line (경춘선 전동열차의 실내 소음 특성)

  • Ann, Yong Chan;Lee, Jung Hyeok;Kim, Seock Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.7
    • /
    • pp.817-822
    • /
    • 2014
  • Since the opening of the double-track railway for the Gyeongchun local electric train and the semi-high speed train ITX, floating population between Seoul and Chuncheon has rapidly increased. This is attributable to the competitiveness of the railway service in terms of punctuality and safety of operation, mass transportation and low fare. However, many passengers have expressed strong dissatisfaction and displeasure towards the interior noise and its high rate of increase, particularly in tunnel sections. In this study, the interior noise characteristics of Gyeongchun local electric train and ITX were analyzed and compared. Noise levels, frequency spectrum and sound quality indices were compared for the open land, tunnel and bridge. Finally, from the noise levels depending on the location in the vehicle compartment, the noise transmission path was determined and a basic strategy for reducing the interior noise was developed.

Nonlinear Analysis of Rubber Bellows for the High Speed Railway Vehicle (고속철도차량 갱웨이 벨로우즈의 비선형 해석)

  • Kang, Gil-Hyun;Kim, Chul-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.8
    • /
    • pp.3631-3637
    • /
    • 2013
  • Gangway bellows in this study is the double wrinkled neoprene rubber component to accept various deviations between the carriage end parts of the articulated type high speed railway vehicle(HSRV). The fatigue failure of the bellows has a harmful effect on the riding comfort for the passengers with the increase of noise and ringing in the ears due to air-tightness failure during pass through a long tunnel. In this study, to assure the safety of gangway bellows of the HSRV, non-linear analysis of the gangway bellows considering triaxial angular displacement(rolling /yawing/pitching) between the carriage end parts are performed. The non-linear properties of the rubber are determined by uniaxial tension and equi-biaxial tension test. Moreover, from the results of non-linear analysis, the effects of the angular displacements and frictional coefficients are evaluated.

The Wind Pressure Stability Analysis of the Platform Screen Door in Urban Railway (도시철도 승강장 스크린 도어의 풍압 안정성 해석)

  • Song, Moon-Shuk;Lee, Seung-Il
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.1
    • /
    • pp.17-22
    • /
    • 2012
  • Installation of screen doors at platform ensures safety of passengers by separating platform from tracks. Besides, it reduces drought and air pressure caused by train conserves heating and cooling energy in the station. In order to guarantee safety of platform screen doors, design considering evaluation of wind pressure requires. In this study, Sosa station, semisealed screen door and EMU are analyzed to estimate the wind pressure of platform screen doors model. Also Sosa station is influenced by climatic condition because it exposed to outside. Therefore, analysis on the wind pressure of platform screen doors is performed under the worst weather condition such as typhoon. The results of analysis, Maximum inside pressure 287 Pa, and consideration of outside pressure as typhoon to the maximum design pressure of 865 Pa 2756.25 Pa conditions approximately 3.1 times the difference can be seen that ensure stability.

Design and Development of Electromagnetic Launcher for Low-High Velocity Impact Test (중고속 충돌 실험을 위한 전자기력 발사장치의 설계와 제작)

  • Kim, Hong Kyo;Noh, Hak Gon;Kang, Beom Soo;Kim, Jeong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.10
    • /
    • pp.857-864
    • /
    • 2016
  • Many plane, UAV and drone fly in the sky as development of aviation industry. Plane and UAV fly and drone's propellers rotate so fast. Impact between flying objects which have high velocity threats passengers. Also the impact damages people, building and various property. Plane's operating speed is near sound velocity(340m/s), and propeller's rotating speed is less than that. Until now, impact experiment uses gas gun to get speed and the gun needs large space to entirely air expansion. Electromagnetic launcher, especially railgun, needs smaller space than gas gun to get enough speed about 500m/s. This paper explains electromagnetic launcher's operating principle, shows making electromagnetic launcher design guide line and suggests that it is a better apparatus to get low-high velocity.