비평형 습증기 모델을 적용한 증기 응축 유동 해석 (ANALYSIS ON STEAM CONDENSING FLOW USING NON-EQUILIBRIUM WET-STEAM MODEL)

  • 김창현;박재현;고동건;김동일;김영상;백제현
    • 한국전산유체공학회지
    • /
    • 제20권3호
    • /
    • pp.1-7
    • /
    • 2015
  • When the steam is used as working fluid in fluid machinery, different from other gases as air, phase transition (steam condensation) can occur and it affects not only the flow fields, but also machine performance & efficiency. Therefore, considering phase transition phenomena in CFD calculation is required to achieve accurate prediction of steam flow and non-equilibrium wet-steam model is needed to simulate realistic steam condensing flow. In this research, non-equilibrium wet-steam model is implemented on in-house code(T-Flow), the flow fields including phase transition phenomena in convergent-divergent nozzle are studied and compared to results of advance researches.

핀 부착 열교환기에서 습증기(mist)발생 메커니즘의 파악을 위한 실험적 고찰 (An Experimental Study on Understanding of Production Mechanism of a Mist from Fin Adhesion heat Exchanger)

  • 최권삼
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2000년도 춘계학술대회 논문집(Proceeding of the KOSME 2000 Spring Annual Meeting)
    • /
    • pp.146-152
    • /
    • 2000
  • As an improvement in the standard of living and economic growth the demand for air conditioning equipment is increasing rapidly. Nowadays air conditioning equipments are being used for industry large building house and car. Thess equipments was concentrated on improving heat efficiency of economic aspects while they design heat exchanger for cooling and heating,. These air conditioning equipments using heat exchanger cause a discomfort to user due to generating mist at the beginning of operating. Therefore the user demand air of high class and quality. In this experimental study to acquire elementary data for development of heat exchanger which be able to supply air of high quality that is to say possess a restraint effect of mist generation. We estimate an effect on cooling plate kind supply air velocity supply air temperature cooled plate temperature and supply air relative humidity which have an influence on outlet air condition of heat exchanger.

  • PDF

비선형 동특성 모델을 통한 전해막 습증기 함유도 특성 예측 (Prediction of Membrane Water Content Characteristics through Dynamic Nonlinear Model)

  • 이찬희;김영현;유상석
    • 한국수소및신에너지학회논문집
    • /
    • 제32권6호
    • /
    • pp.497-505
    • /
    • 2021
  • Water management is essential to improve the performance of proton exchange membrane fuel cells. This study targets to understand the characteristics of water concentration in proton exchange membrane fuel cells at a dynamic load variable environment. The fuel cell model was developed to simulate nonlinear water transport in membrane by the MATLAB/Simulink® (MathWorks, Natick, MA, USA) platform, and it calculates water content in membrane, ionic conductivity, and predicts fuel cell performance through one-dimensional analysis.

핀-튜브 열교환기에서의 습증기 발생 메커니즘의 파악을 위한 실험적 연구 (An Experimental Study on Understanding of Production Mechanism of a Mist from Fin-Tube Heat Exchanger)

  • 박상균;윤석훈;김경근;김명환;오철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권3호
    • /
    • pp.595-604
    • /
    • 2001
  • As an improvement in the standard of living and economic growth, the demand for air conditioning equipment is increasing rapidly. Nowadays, air conditioning equipments are being used for industry, large building, house and car. There equipments were concentrated on improving heat efficiency of economic aspects while thy design heat exchanger for cooling and heating. These air conditioning equipments using heat exchanger cause a discomfort to user due to generating mist at the beginning of operating. Therefore, the user demand air of high class and quality. In this experimental study, to acquire elementary data for development of heat exchanger which be able to supply air of high quality, that is to say, possess a restraint effect of mist generation. We estimate an effect on cooling plate quality, supply air velocity, supply air temperature, cooled plate temperature and supply air relative humidity which have an influence on outlet air condition of heat exchanger.

  • PDF

원전 2차 계통에서 아민의 pH 제어 특성 연구 (A Study on Characteristics of pH Control with Amines in the Secondary Side of Nuclear Power Plants)

  • 이인형;안현경;박병기;권혁준;송찬호
    • 한국산학기술학회논문지
    • /
    • 제11권8호
    • /
    • pp.3112-3118
    • /
    • 2010
  • 최근 경수로형 원전 2차 계통의 건전성 유지를 위해 수처리제를 암모니아에서 에탄올아민으로 전환하였으나, 적용 후 복수 및 저압급수가열기 영역에서의 pH가 감소하므로 본 연구에서는 최적의 pH 제어제로 사용 할 수 있는 아민을 조사하였다. 대체아민 조사 결과 최적 조건을 만족시키는 단일 아민은 존재하지 않았다. 암모니아는 상대휘발도가 높아 증기에 많이 분포되어 증기 응축수인 복수에서 pH가 높으며, 상대휘발도가 낮은 에탄올아민은 습증기 영역의 pH를 높여 유체가속부식을 억제하므로 증기발생기 철 슬러지 유입을 감소하는데 효과적인 것으로 나타났다. 따라서 복수 및 저압급수계통에서 pH가 높은 암모니아와 습증기영역의 유체가속부식 측면에서 특성이 우수한 에탄올아민(ETA)을 혼합 주입하는 복합아민을 선택하면 2차 계통 재질의 손실을 최소화하여 증기발생기 건전성을 확보할 수 있을 것이다.

습냉매를 적용한 증기-증기 이젝터용 OTEC 시스템의 성능비교 (The performance comparison of vapor-vapor ejector OTEC system using wet refrigerants)

  • 윤정인;손창효;김영복;예병효;하수정;이호생;김현주
    • 한국태양에너지학회 논문집
    • /
    • 제34권4호
    • /
    • pp.51-56
    • /
    • 2014
  • In this paper, OTEC(Ocean Thermal Energy Conversion) system with vapor-vapor ejector is newly proposed. And 6 wet refrigerants are applied into the proposed OTEC system for performance comparison. The results of comparison performance are as follows. In the view of system efficiency, R32/R744(90:10) has the highest efficiency among the 6 refrigerants. In case of evaporation capacity, pump work and mass flow rate of working fluid, R744, R717 and R717 is lowest value, respectively. As this results, the vapor-vapor ejector is able to increase the efficiency of system. And It is necessary to select the optimized working fluid considering environmental and economic factors.

습증기 투입 조건에 따른 가습용 중공사막 튜브 수분 투과 특성 (Moisture Permeation Characteristics of Hollow Fiber Membrane Tube for Humidification According to Input Conditions of Wet Steam)

  • 채종민;유상석
    • 한국수소및신에너지학회논문집
    • /
    • 제29권6호
    • /
    • pp.620-626
    • /
    • 2018
  • Recently, fuel cell field is receiving much attention as an environmentally friendly energy in the world. Among the various types of fuel cells, in the case of PEMFC, ions move through the membrane in the middle of the unit cell. Therefore, proper moisture is required inside the PEMFC. In the case of membrane type humidifier, flat membrane or hollow fiber membrane is mainly used. Since various parameters can change the performance, the performance investigation has to be carried out with parameters. In this study, water transport of hollow fiber membrane was investigated in terms of principle operating conditions such as temperature and flow rate.

터빈 운전 신뢰성 향상을 위한 응력부식균열 평가 (The Evaluation of the Stress Corrosion Cracking for Improvement of Reliability in Turbine Operation and Maintenance)

  • 강용호;송정일
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.280-287
    • /
    • 2008
  • In case of low pressure steam turbine used in power plant, it was operated in wet steam and high stress condition. Therefore, it is possible that the corrosion damage of low pressure was induced by this condition. According to previous study, about 30% of total blade failure correspond to corrosion fatigue or SCC(stress corrosion cracking) in low pressure turbine. Especially, LSB(last stage bucket) of low pressure turbine has a higher hardness to prevent erosion damage due to water droplet however, generally this is more dangerous for SCC damage. Therefore, to improve reliability of turbine blade. various methods for SCC evaluation has been developed. In this study, the crack found in LSB during in-service inspection was evaluated using microstructure analysis and stress analysis. From the stress analysis, the optimum size of fillet to remove the crack was proposed. And also, the reliability was evaluated for modified LSB using GOODMAN diagram.

  • PDF

한국형 지열발전 타당성 연구 (A Feasibility Study on Geothermal Power Plant in Korea)

  • 임효재;권정태;김금수;장기창
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.39-44
    • /
    • 2009
  • Geothermal energy is the heat contained in the earth and its internal fluids. Geothermal energy is stored as sensible or latent heat. Supplied by both internal and external sources, it represents a vast supply which is only started to be tapped for generation of electric power. In general, this is natural dry or wet medium to high enthalpy steam at temperatures above $150^{\circ}C$. For some time, binary systems employing substances with a lower boiling point than water in a secondary circuit have been used to generate vapor for driving turbines at a lower temperature level. The utilization of binary plants and the possibility of production from enhanced geothermal systems can expand its availability on a worldwide basis. The geothermal electricity installed capacity is approaching the 10,000GW threshold. Geothermal energy is not present everywhere, but its baseload capability is a very important factor for its success.

  • PDF

대기 증기압차가 참외 발효과 발생에 미치는 영향 (Influence of Atmospheric Vapor Pressure Deficit on Fruit Fermentation of Oriental Melon(Cucumis melo L. var makuwa Makino))

  • 신용습;서영진;최충돈;박소득;최경배;윤재탁;김병수
    • 생물환경조절학회지
    • /
    • 제16권3호
    • /
    • pp.174-179
    • /
    • 2007
  • 참외 발효과 발생에 영향을 미치는 증산과 관련된 몇 가지 요인을 검토한 결과는 다음과 같다. 참외의 증산율은 지온이 높고 토양수분 함량이 많을수록 높았으며, 광도가 약하여 온도가 낮을 경우 증산율과 기공 전도도가 낮아졌고, 저온 다습한 기상조건에 의한 증산의 억제는 식물체와 대기사이의 증기압기울기가 낮아지는 것으로 생각된다. 발효과 발생은 과실의 비대가 느린 착색기 이후에 토양수분이 -10 kPa로 많고, 저온 다습하여 참외와 대기 사이에 증기압기울기가 낮게 형성되어 증산이 억제될 때 발생하였다. 따라서 참외의 발효과 발생은 착색기 이후 참외의 과실 비대가 지연되는 반면 지온이 높아 뿌리로부터 지상부로 수분의 공급이 원활하고, 저온 다습한 기상조건하에 수분의 증산이 억제되어 수분이 태좌부로 유입되면 발효과가 발생되는 것으로 생각된다.