• Title/Summary/Keyword: 슬러지량

Search Result 511, Processing Time 0.024 seconds

The Treatment of Animal Wastewater by the Combination of Trickling Filter System and Activated Sludge Process (살수여상 활성오니 연계방법에 의한 축산뇨요수 처리)

  • Ryoo J. W.
    • Journal of Animal Environmental Science
    • /
    • v.10 no.2
    • /
    • pp.81-86
    • /
    • 2004
  • This experiment was conducted to evaluate combination system of wood chip trickling system and activated sludge process. The results obtained are summarized as tallows. The trickling filter system using wood chip was used as a biological pre-treatment system for treating piggery wastewater. At pre-treatment the removal efficiencies were BOD $91\%$ CODmn $65\%$, SS $75\%$ T-N $73\%$, T-P $69\%$. After pre-treatment the removal efficiencies in activated sludge process were BOD $99\%$ CODmn $94.6\%$, SS $97.8\%$ T-N $91.1\%$, T-P $91\%$. This study shows a very stable method with pre-treatment of trickling filter using wood chip. These combined treatment system was very useful for piggery wastewater.

  • PDF

PU-AC 고분자 담체를 이용한 염색폐수처리

  • 김서연;신원식;김영훈;송동익
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2004.05a
    • /
    • pp.312-315
    • /
    • 2004
  • 염색가공 공정에서 배출되는 염색폐수는 염색 가공공정이나 사용하는 염료등에 따라 폐수량과 성상의 변화가 심하기 때문에 처리에 많은 어려움이 있다. 일반적인 염색폐수 처리방법으로는 물리화학절인 응집침전법과 생물학적인 활성슬러지법을 단독 또는 조합하여 주로 사용하여 왔다. 그러나 최근에는 기존시설의 처리 향상을 위한 다각적인 기술개발이 시도되고 있으며 그 일환으로 본 연구에서는 활성탄을 담지한 폴리우레탄 담체를 개발하여 염색폐수를 처리하고자 하였다. 본 연구에서는 담체를 이용한 염색폐수의 생물학적 처리 시 여러 인자들, 즉 COD/N 비, DO 농도, 담체의 충진율 등의 영향을 조사하기 위하여 회분식 실험을 수행하였다. 또한 회분식 실험에서 얻은 최적조건을 이용하여 파일럿 실험도 함께 수행하였다. COD/N 비가 COD 제거에 미치는 영향을 살펴보기 위해 COD/N 비를 조절하지 않은 경우와 COD/N 비를 2-3으로 조절한 경우에 대해서 비교하였다. 실험결과 염색폐수의 초기 COD 농도가 1,000 ppm일 때, 처리 후 COD 농도는 COD/N 비를 조절하지 않았을 경우 860 ppm (제거효율 = 18%), COD/N 비가 2일 경우 550ppm (제거효율 = 52%), COD/N 비가 3의 경우 390 ppm (제거효율 = 57%)으로 각각 나타났다. DO 농도가 COB 제거에 미치는 영향을 알아보고자 DO 농도를 1, 6, 7 mg/L로 변화시켰다. 그 결과 DO의 농도가 1 mg/L일 경우 COD 제거효율은 20% 정도였으나, DO 농도가 6 mg/L이상에서는 모두 80%에 가까운 제거효율을 나타내었다. 담체 충진율의 경우, 10% 충진시 40%, 20% 충진시 50%, 30% 충진시 70%의 제거효울을 각각 나타내었다. 회분식 실험에서 얻은 최적조건으로 파일럿 반응기를 100일 이상 운전한 결과 염색폐수의 COD 농도변화는 1,000ppm에서 380ppm로 평균 60%이상 제거되는 높은 효율을 보였다. 또 담체 첨가의 영향을 살펴보기위해, 담체를 충진하지 않은 조건에서 파일럿 반응기를 운전한 결과 평균 COD 제거율은 50%로 비교적 낮은 효율을 보였다.

  • PDF

Contactor Coupled Sequencing Batch Reactor for Nitrogen Removal (접촉조 결합형 연속회분식반응조를 이용한 질소제거)

  • Nam, Se-Yong;Lee, Sang-Min;Kim, Dong-Wook;Seo, Yong-Chan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.11
    • /
    • pp.1141-1145
    • /
    • 2005
  • A contactor coupled sequencing batch reactor composed of pre-anoxic contact zone and intermittently aerated zone was proposed and operated for nitrogen removal. Emphasis was placed on the fact that the contactor can be operated in a rapid reaction mode that results In biological uptake but incomplete metabolism of organic matter. Consequently, 61.2% of the sewage SCOD was adsorbed to activated sludge by 30-minute contact reaction. The specific uptake of organic matter was 22.3 mg SCOD/g MLVSS that enhanced the denitrification efficiency in the following denitrification stage. The removal efficiencies of the organic matter(SCOD) and the total nitrogen(T-N) were 86% and about 60% at the TCOD/TKN ratio as low as 6.0, respectively.

Treatment of Livestock Wastewater with Coagulant-loess (황토를 이용한 축산폐수의 처리에 관한 연구)

  • Park, Jin-Hee;Kim, Bo-Guk;Won, Chan-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1799-1808
    • /
    • 2000
  • To investigate the applicability of loess as a coagulant. the optimum conditions of coagulation and efficiency comparison of several coagulants (PAC, PACS, LAS) in chemical treatment of livestock wastewater were performed. As a result, the optimum mixing ratio of loess and lime(CaO) was 3:7. The optimum dosage of the mixed coagulant was 30 g/L. The optimum speed for rapid mixing of the mixed coagulant was 200 rpm at 1 min. and the optimum speed for slow mixing was 50 rpm at 10 min. The mixed coagulant showed the removal efficiency of turbidity, SS, BOD, $COD_{cr}$. T-P and TKN to 95.8%, 92.5%, 71.6%, 71.1%, 98.2% and 32.5%, respectively, which was better than other several coagulants. The mixed coagulant was possible to use as substitutional coagulants of traditional coagulant, and the producted sludge can use as a soil amendments.

  • PDF

Parameters Affecting Nitrite Accumulation in Submerged Biofilm Reactor (생물막 반응기에서 아질산성 질소의 축척에 미치는 영향인자)

  • Hwang, Byung-Ho;Hwang, Kyung-Yub;Choi, Eui-So
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1789-1797
    • /
    • 2000
  • The objective of this study was to assess parameters affecting nitrite accumulation, which offers advantages in terms of less aeration energy and carbon consumption for denitrification. The influence of the alkalinity to $NH_4{^+}-N$ concentration ratio, pH, FA(free ammonia) concentration and temperature on nitrite accumulation was investigated. The experiment was performed with supernatant from dewatering process of anaerobic digested sludge using a submerged biofilm reactor. The influent contains high strength of ammonium nitrogen and the alkalinity was insufficient for complete nitrification. An increased nitrite accumulation was observed with increase in alkalinity to $NH_4{^+}-N$ concentration ratio. The increase in alkalinity to $NH_4{^+}-N$ concentration ratio has been a maior reason for the high pH value and FA concentration in the reactor. It can be considered that selective inhibition of Nitrobacter can be causes of nitrite accumulation. The nitrite accumulation increased with increment of temperature at fixed alkalinity to $NH_4{^+}-N$ concentration ratio.

  • PDF

A Study on Treatment Characteristics and Design of Ultra High Rate Method (Ultra High Rate(UHR) 법의 처리특성 및 설계에 관한 연구)

  • Lee, Jeoung-Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.12
    • /
    • pp.2239-2245
    • /
    • 2000
  • For the treatment of wastewater being discharged in large quantities as in these modern times, qualitative and quantitative concepts should be introduced in consideration of the recycling. In view of a qualitative concept, high rate aeration process is known as the most effective process up to now. However, Lee suggested UHR process showing the superiority over high rate process in treatment rate and quantity. Therefore, this study was performed to investigate the basic sphere of design and treatment quality, such as applicable $BOD_5$-loading and influent wastewater concentration of UHR process, based on Lee's suggestions1). Consequently, this process showed applicable $BOD_5$-loading of $2.2{\sim}7.0kg-BOD_5/kg-MLSS{\cdot}day$, exceeding three times or more of high rate process with maximum applicable loading of $2.25kg-BOD_5/kg-MLSS{\cdot}day$. Meanwhile, with the range of influent wastewater concentration from 200 to 450 mg/L. it showed the treatment rate from 94.7 to 97.3%, it indicated very good condition. In view of quantitative concept of treatment, UHR process is considered an epoch-making treatment process being superior to existing ones.

  • PDF

폐비닐 재생메디아를 이용한 생물막공정에서의 하수처리 특성

  • Jang, Seong-Ho;Seo, Jong-Hwan;Park, Jin-Sik
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2007.05a
    • /
    • pp.375-379
    • /
    • 2007
  • 폐비닐 여재(Synthetic Waste Polyethylene Media)를 적용한 부착성장식 공정의 유기물 및 질소${\cdot}$인 제거특성에 관한 Pilot Plant 실험 결과 다음과 같은 결론을 얻을 수 있었다. 1) 제거효율은 $RUNI1{\sim}3$에서 $COD_{cr}$ 91.4, 92.4, 93.9%, T-N 56.9, 61.4, 65.1%, T-P는 모든 단계에서 약 45%이상 제거되어 부하변동시에 강한 대처능력을 나타내었다. 2) BOD용적부하 $0.18{\sim}0.40kg/m^3{\cdot}d$, COD용적부하 $0.28{\sim}0.53kg/m^3{\cdot}d$, ${NH_4}^{+}-N$용적부하 $0.12kg/m^3{\cdot}d$을 나타내었다. 3) 도시하수 처리를 위한 생물학적 질소 및 인 제거공법을 본 여재를 이용하여 공정설계시 고려할 사항들과 적절한 대처방법을 다음과 같이 제시할 수 있다. - 1차 침전지에서 유기질소 및 유기인 농도가 높다면 유기질소 및 인 부하량을 감소시키기 위하여 1차 침전지를 설치하되 질소 및 인제거에 유리한 $BOD_5/T-N$, $BOD_5/T-P$를 유지할 수 있도록 체류시간을 1시간미만으로 설계하는 것이 경제적이라고 판단된다. 만일 유기질소와 유기인의 함량이 낮다면 1차 침전지는 제외하는 것이 유리할 것이다. - 여재의 배치는 폭기조에서 용존산소의 균일분포와 슬러지의 적정탈리를 위해 여재를 상하로 배치하거나 또는 여재끼리 일정 간격을 두어 배치하는 것이 바람직하다. 농촌에서의 처분이 문제시 되고 있는 폐비닐을 적용한 본 연구에서의 수처리특성은 기존 하수처리공정에서의 제거효율에 상응하는 처리특성을 나타내었다. 또한 폐비닐 처분의 문제를 해결할 수 있을뿐만 아니라 하수처리시에도 부하변동 등에 강한 대처능력을 나타내어 기존의 하수처리공정에 대체가능성을 나타내었다.

  • PDF

Leaching Properties of Hexavalent Chromium in Sintering Condition of Clinker material (클링커 원료의 소성 조건에 따른 6가 크롬 용출 특성)

  • Lee, Jung-Hui;Park, Nam-Kyu;Jung, Yon-Jo;Chu, Yong-Sik;Song, Hun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.549-552
    • /
    • 2008
  • The cement is accomplished with CaO, SiO2, Al2O3 and Fe2O3, etc. After pulverizing materials of the limestone, the sand and the clay(shale), iron ore, the cement becomes clinker materials sintering from the rotary kiln of oxidizing atmosphere. The part in the materials of the clinker is substituted with slag, sludge etc. and it is used. because The chromium which is to be included in the clinker materials, in sintering process hexavalent chromium is converted with the chrome. Consequently it changed the type and a content of clinker materials and test hexavalent chromium of the clinkers which is manufactured.

  • PDF

Ocean Outfall과 폐수처리 공정의 비용분석을 이용한 수영만의 수질관리

  • Park, Hae-Sik;Park, Cheong-Gil;Lee, Seok-Mo
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 1997.10a
    • /
    • pp.52-53
    • /
    • 1997
  • 수역의 유기오염 개선을 위하여 생활하수, 산업폐수 등의 저하시키는데 주안점을 두어왔으나 공공수역에서의 제거되지 않은 질소와 인의 유입으로 부영양화가 진행되어 하천에는 남조류가 대량발생하고 해역에는 적조가 광역에서 발생하여 큰 사회문제가 되고 있고, 질소와 인의 유입으로 인한 자생 COD가 전체COD의 약 절반을 차지하고 있는 실정이다. 따라서 앞으로의 수질을 개선하기 위해서는 조류증식의 제한인자인 질소와 인의 규제가 필요할 뿐만아니라 하수처리장에 고차처리를 적용하거나, 해양의 회석자용을 이용한 Ocean을 적용하여 연안해역 수질을 관리해야 할 것이다. 따라서 본 연구는 수영만을 대상으로 Ocean Outfall과 폐수처리시절을 적절하게 조합하기 위해서 3차원 생태계모델을 적용하여 유기물질 뿐만 아니라 영양염류인 질소와 인의 농도를 예측하여 환경기준을 만족시키고 비용을 최소화 할 수 있는 폐수처리공법과 해중방류관의 위치를 선정하고자 하였다. 본 연구결과 수영만의 1994년 COD는 II등급, DIN과 DIP는 III등급이었다. 현재의 활성슬러지공법으로 질소와 인을 제거하지 않고 방류할 경우 2001년에 는 하수처리량의 증가로 인해 COD의 경우 1994년 보다 조금 감소하지만 DIN 과 DIP는 1994년과 같은 III등급을 유지하였다. 고도처리공법을 도입할 경우 COD의 농도는 광안리와 해운대해수욕장에서 I등급을 보이고, DIP의 농도도 수영만 전체에서 강등급을 보이지만, DM의 농도는 광안리해수욕장에서 II등급, 해운대해수욕장에서 IH등급을 보였다 하수처리장 유출수를 Ocean Outfall을 이용하여 하수처리장으로부터 4km에 서 방류할 경우의 COD농도는 I등급을 보이고, DE 농도도 광안리와 해운대해 수욕장에서는 I등급을 보이고, DU의 농도는 ll등급을 보여 수질이 개선된 것 을 볼 수 있다. 이상에서와 같이 광안리와 해운대해수욕장의 해역환경기준 ll등급을 만족 하는 하수처리방법은 Ocean Outfall이었다. 수영하수처리장에 인을 처리하기 위한 화학적 침전법의 경우 956억원이 소요되고, 질소를 제거하기 위한 질소제거공정을 추가 건설 할 경우는 2181억원이 전요된다. 그리고 두공정을 같이 건설할 경우에는 3137억원의 비용이 소요된다 수영하수처리장에서 4km 거리와 관경을 2m의 Ocean Outfall 건설비용은 325 억원 정도가 소요되는 것으로 산출되었다. 고차처리시 증가되는 비용으로 건설할 수 있는 Ocean Outfall의 길이는 인 제거공정을 첨가하는 경우에는 18km을 건설할 수 있고, 질소제거공정을 첨가 하는 경우에는 46km를 건설할 수 있는 것으로 산출되었다.

  • PDF

Removal of Nutrients Using an Upflow Septic Tank(UST) - Aerobic Filter(AF) System (부패조와 호기성 여과공정을 이용한 영양염류 제거)

  • Park, Sang-Min;Jun, Hang-Bae; Bae, Jong-Hun;Park, Woo-Kyun;Park, Noh-Back
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.3
    • /
    • pp.232-238
    • /
    • 2010
  • The objective of this study was to investigate a small sewage treatment system. This system was developed to improve a nitrogen and phosphorus removal efficiency and generate less solid using upflow septic tank(UST) - aerobic filter(AF) system. The UST equipped with an aerobic filter, the filter was fed with both raw sewage and recycled effluent from the UST to induce the denitrification and solid reduction simultaneously. Overall removal efficiencies of COD and total nitrogen(TN) were above 96% and 73% at recycle ratio of 200%, respectively. Critical coagulant dose without the biochemical activity was found to be 40 mg/L. Removal efficiency of total phosphorus(TP) in influent was above 90% by chemical and biological reactions. Although the phosphorus concentration was low under the high alkalinity in raw sewage, the pH value was unchanged by the coagulant dose.