• Title/Summary/Keyword: 스팀 가스화

Search Result 48, Processing Time 0.025 seconds

A Study on Establishment of Technical Guideline of the Installation and Operation for the Biogas Utilization of Power generation and Stream - Design and Operation Guideline (바이오가스 이용 기술지침 마련을 위한 연구(III) - 기술지침(안) 중심으로)

  • Moon, HeeSung;Bae, Jisu;Pack, Hoyeun;Jeon, Taewan;Lee, Younggi;Lee, Dongjin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.2
    • /
    • pp.95-103
    • /
    • 2018
  • As a guideline for desulfurization and dehumidification pretreatment facility for optimizing utilization of biogas, the $H_2S$ concentration is set at 150 % which can be treated with iron salts, dehumidification is the optimum value for generator operation, and the relative humidity applied at the utilization of biogas in EU is set at 60 %. We have set up the generator facility guidelines to optimize utilization of biogas. The appropriate amount of biogas should be at least 90 % of the total gas generation, and the capacity of generator facility should be set at 20~30 %. In order to equalize the pressure of the incoming gas the generator, a gas equalization tank should be installed and the generator room average temperature should be kept at $45^{\circ}C$ or less. Since the gas is not produced at a certain methane concentration in the digester, the efficiency is lowered. Therefore, it is required to install an air fuel ratio control system according to the change in methane concentration. Therefore, it is necessary to compensate for the disadvantages of biogasification facilities of organic waste resources and optimize utilization of biogas and improve operation of facilities. This study was conducted to optimize biogas utilization of type of organic waste(containing sewage sludge and food waste, animal manure), investigate the facilities problem and propose design, operation guidelines such as pre-treatment facilities and generators.

SNG Production from CO2-Rich Syngas in a Pilot Scale SNG Process (파일럿 규모의 공정에서 CO2가 함유된 합성가스로부터 합성천연가스(SNG) 생산)

  • Kang, Suk-Hwan;Ryu, Jae-Hong;Kim, Jin-Ho;Kim, Hyo-Sik;Yoo, Young-Don;Kim, Jun-Woo;Koh, Dong-Jun;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • v.57 no.3
    • /
    • pp.420-424
    • /
    • 2019
  • In SNG (synthetic natural gas) process by proposed RIST(Research Institute of Industrial Science & Technology)-IAE(Institute for Advanced Engineering) (including three adiabatic reactors and one isothermal reactor), the methanation reaction and water gas shift (WGS) reaction take place simultaneously, and the supply of steam with syngas might control the temperature in catalyst bed and deactivate the catalyst. In this study for development of SNG process, the characteristics of the methanation reaction with a Ni-based catalyst by prepared RIST and using a low $H_2/CO$ mole ratio (including $CO_2$ 22%) are evaluated. The operating conditions ($H_2O/CO$ ratio of the $1^{st}$ adiabatic reactor, operating temperature range of $4^{th}$ isothermal reactor, etc.) were reflected the results from previous studies and in the same condition a pilot scale SNG process is carried out. As a results, the pilot scale SNG process is stable and the CO conversion and $CH_4$ selectivity are 100% and 96.9%, respectively, while the maximum $CH_4$ productivity is $660ml/g_{cat}{\cdot}h$.

Analysis on the Heat Exchange Efficiency of Kraft Recovery Boiler by Nose Arch Structure Using CFD (CFD를 활용한 크래프트 회수보일러 내부 노즈 아치 구조에 따른 열교환 효율 분석)

  • Jang, Yongho;Park, Hyundo;Lim, Kyung pil;Park, Hansin;Kim, Junghwan;Cho, Hyungtae
    • Applied Chemistry for Engineering
    • /
    • v.32 no.2
    • /
    • pp.149-156
    • /
    • 2021
  • A kraft recovery boiler produces steam for power generation by the combustion of black liquor from the kraft pulping process. Since saturated steam became superheated in a superheater above the furnace, it is important to increase the heat exchange efficiency for the superheated steam production and power generation. A nose arch at the bottom of the superheater is important for blocking radiation from the furnace which causes corrosion of the superheater. But the nose arch is the main reason for creating a recirculation region and then decreasing the heat exchange efficiency by holding cold flue gas after the heat transfer to saturated steam. In this study, the size of recirculation region and the temperature of flue gas at the outlet were analyzed by the nose arch structure using computational fluid dynamics (CFD). As a result, when the nose arch angle changed from 106.5° (case 1) to 150° (case4), the recirculation region of flue gas decreased and the heat exchange efficiency between the flue gas and the steam increased by 10.3%.

Biomass Energy in the USA: A Literature Review (II) - Marketing and Policies for Green Power Production with Environmental Attributes - (미국 에너지 시장에 공급되는 바이오에너지에 관한 연구(II) - 환경친화적 녹색전기의 마케팅 및 정부지원책에 대하여 -)

  • Kim, Yeong-Suk;Gorman, Thomas
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.1 s.129
    • /
    • pp.97-110
    • /
    • 2005
  • This paper is the second part of a literature review describing the current status of biomass energy use in the USA. The bioenergy technologies that convert biomass resources to a form of energy were presented, in particular focused on existing coal fired boiler, high efficiency gasification combined cycle. We presented latest biomass power energy supply, economic issues such as its production and plant investment cost in the Part I. In the Part II, our review summarized policy and market issues for electricity consumers, benefits from biomass power which could offer an alternative to conventional energy sources in the form of environmental, rural economic growth, and national energy security in the USA.

Auto Tuning of Position Controller for Proportional Flow Control Solenoid Valve (비례유량제어밸브 위치제어기 자동조정)

  • Jung, Gyu-Hong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.7
    • /
    • pp.797-803
    • /
    • 2012
  • Proportional solenoid valves are a modulating type that can control the displacement of valves continuously by means of electromagnetic forces proportional to the solenoid coil current. Because the solenoid-type modulating valves have the advantages of fast response and compact design over air-operated or motor-operated valves, they have been gaining acceptance in chemical and power plants to control the flow of fluids such as water, steam, and gas. This paper deals with the auto tuning of the position controller that can provide the proportional and integral gain automatically based on the dynamic system identification. The process characteristics of the solenoid valve are estimated with critical gain and critical period at a stability limit based on implemented relay feedback, and the controller parameters are determined by the classical Ziegler-Nichols design method. The auto-tuning algorithm was verified with experiments, and the effects of the operating point at which the relay control is activated as well as the relay amplitude were investigated.

Degradation of Aqueous Monoethanolamine Absorbent (모노에탄올아민 흡수제의 열화특성 분석)

  • Cho, Youngmin;Nam, Sung-Chan;Yoon, Yeo-Il;Moon, Sungjun;Baek, Il Hyun
    • Applied Chemistry for Engineering
    • /
    • v.21 no.2
    • /
    • pp.195-199
    • /
    • 2010
  • The reversible chemical absorption using MEA (monoethanolamine), one of alkanolamine, is generally used as a conventionally method for $CO_{2}$ capture. Even MEA absorbent has excellent reactivity with $CO_{2}$, it has been known to have the decrease of absorption capacity caused by $CO_{2}$, $O_{2}$ or other acid gases in flue gas, corrosion and thermal degradation. In this study, MEA solutions degraded in the steam reforming process of refinery used and the absorption performance were compared for the used of conventional MEA solution. In case of 30 wt% MEA and mixture of 20 wt% thermal degraded absorbent (DP) and 10 wt% PZ, the absorption capacities were $0.5365mol-CO_{2}$/mol-absorbent and $0.5939mol-CO_{2}$/mol-absorbent respectively. PZ added thermally degraded absorbent showed the enhanced absorption capacity. On the contrary, the absorption rates were $1.1610kg_{f}/cm^2{\cdot}min$ for 30 wt% MEA, $0.5310kg_{f}/cm^2{\cdot}min$ for mixture of 20 wt% thermal degraded absorbent (DP) and 10 wt% PZ and $0.3525kg_{f}/cm^2{\cdot}min$ for 30 wt% thermally degraded absorbent only. The absorption rates of PZ added thermally degraded absorbent was higher than that of thermally degraded absorbent only. Therefore, it can be confirmed that thermally degraded absorbent can be reused as an absorbent for $CO_{2}$ by the addition of suitable additives.

Development of a Pre-treating Equipment and the Carcass Disposal System for Infected Poultry (감염가금 전처리 및 폐사가축 처리시스템 개발)

  • Hong, J.T.;Kim, H.J.;Yu, B.K.;Lee, S.H.;Hyun, C.S.;Ryu, I.S.;Oh, K.Y.;Kim, S.;Kwon, J.H.;Tack, D.S.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.2
    • /
    • pp.81-92
    • /
    • 2011
  • When we bury the infected poultry into the ground, we have many problems such as the difficulty of making sufficient area for burying, environmental contamination by the leachate, unpleasant ordor. Also, in case of burning the carcass of the infected poultry, there are some problems such as high cost, dust, unpleasant odor, etc. It could cause environmental contamination which many peoples and environmental organization complains about. In this study, we develop a treating system which treats the infected poultry carcass in a environmental method preventing the environment contamination. This system is composed of many processes. The euthanasia system uses rigid vinyl to trap and to do a euthanasia the infected poultry with lethal gas, carbon dioxide. And then, with the tractor attached grappler infected poultry carcass could be put into the carcass treating system. The euthanasia system uses rigid vinyl to trap the infected birds and to confine lethal gas, carbon dioxide. Infected poultry carcass are moved to carcass disposal system by collecting device which is attached at tractor. The carcass treatment system (capacity of disposal : 6.3 $m^3$) is installed on a truck and do one pass work, which is input, crush, stir, sterilize, and discharge treated carcass. 1,000 chickens was killed within 9.7min by $CO_2$ (300L/min) in the tent (10 $m^3$). The collecting device could carry 142 chickens at a time, and the movable carcass treatment system could sterilize 2 tons carcass per hour (at one time). This treatment systems was eco-friendly because it reduced the volume of carcass by 31.9% with no wastewater generation.

0.1 MW Test Bed CO2 Capture Studies with New Absorbent (KoSol-5) (신 흡수제(KoSol-5)를 적용한 0.1 MW급 Test Bed CO2 포집 성능시험)

  • Lee, Junghyun;Kim, Beom-Ju;Shin, Su Hyun;kwak, No-Sang;Lee, Dong Woog;Lee, Ji Hyun;Shim, Jae-Goo
    • Applied Chemistry for Engineering
    • /
    • v.27 no.4
    • /
    • pp.391-396
    • /
    • 2016
  • The absorption efficiency of amine $CO_2$ absorbent (KoSol-5) developed by KEPCO research institute was evaluated using a 0.1 MW test bed. The performance of post-combustion technology to capture two tons of $CO_2$ per day from a slipstream of the flue gas from a 500 MW coal-fired power station was first confirmed in Korea. Also the analysis of the absorbent regeneration energy was conducted to suggest the reliable data for the KoSol-5 absorbent performance. And we tested energy reduction effects by improving the absorption tower inter-cooling system. Overall results showed that the $CO_2$ removal rate met the technical guideline ($CO_2$ removal rate : 90%) suggested by IEA-GHG. Also the regeneration energy of the KoSol-5 showed about $3.05GJ/tonCO_2$ which was about 25% reduction in the regeneration energy compared to that of using the commercial absorbent MEA (Monoethanolamine). Based on current experiments, the KoSol-5 absorbent showed high efficiency for $CO_2$ capture. It is expected that the application of KoSol-5 to commercial scale $CO_2$ capture plants could dramatically reduce $CO_2$ capture costs.