• Title/Summary/Keyword: 스텐트재협착

Search Result 35, Processing Time 0.03 seconds

A Study on Optimal Shape of Stent by Finite Element Analysis (유한요소 해석을 이용한 스텐트 최적형상 설계)

  • Lee, Tae-Hyun;Yang, Chulho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.1-6
    • /
    • 2017
  • Stents are widely used as the most common method of treating coronary artery disease with implants in the form of a metal mesh. The blood flow is normalized by inserting a stent into the narrowed or clogged areas of the human body. In this study, the mechanical characteristics of a stent are investigated according to the variations of its design parameters by the Taguchi method and finite element analysis. A stent model of the Palmaz-Schatz type was used for the analysis. In the analysis, an elasto-plastic material model was adopted for the stent and a hyper-elastic model was used for the balloon. The main interest of this study is to investigate the effects of the design parameters which reduce the possibility of restenosis by adjusting the recoil amount. A Taguchi orthogonal array was constructed on the model of the stent. The thickness and length and angle of the slot were selected as the design parameters. The amounts of radial recoil and longitudinal recoil were calculated by finite element analysis. The statistical analysis using the Taguchi method showed that optimizing the shape of the stent could reduce the possibility of restenosis. The optimized shape showed improvements of recoil in the radial and longitudinal directions of ~1% and ~0.1%, respectively, compared to the default model.

Ex vivo Morphometric Analysis of Coronary Stent using Micro-Computed Tomography (미세단층촬영기법을 이용한 관상동맥 스텐트의 동물 모델 분석)

  • Bae, In-Ho;Koh, Jeong-Tae;Lim, Kyung-Seob;Park, Dae-Sung;Kim, Jong-Min;Jeong, Myung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.93-98
    • /
    • 2012
  • Micro-computed tomography (microCT) is an important tool for preclinical vascular imaging, with micron-level resolution. This non-destructive means of imaging allows for rapid collection of 2D and 3D reconstructions to visualize specimens prior to destructive analysis such as pathological analysis. Objectives. The aim of this study was to suggest a method for ex vivo, postmortem examination of stented arterial segments with microCT. And ex vivo evaluation of stents such as bare metal or drug eluting stents on in-stent restenosis (ISR) in rabbit model was performed. The bare metal stent (BMS) and drug eluting stent (DES, paclitaxel) were implanted in the left or right iliac arteries alternatively in eight New Zealand white rabbits. After 4 weeks of post-implantation, the part of iliac arteries surrounding the stent were removed carefully and processed for microCT. Prior to microCT analysis, a contrast medium was loaded to lumen of stents. All samples were subjected to an X-ray source operating at 50 kV and 200 ${\mu}A$ by using a 3D isotropic resolution. The region of interest was traced and measured by CTAN analytical software. Objects being exposed to radiation had different Hounsfield unit each other with values of approximately 1.2 at stent area, 0.12 ~ 0.17 at a contrast medium and 0 ~ 0.06 at outer area of stent. Based on above, further analyses were performed. As a result, the difference of lengths and volumes between expanded stents, which may relate to injury score in pathological analysis, was not different significantly. Moreover, ISR area of BMS was 1.6 times higher than that of DES, indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. And ISR area of BMS was higher ($1.52{\pm}0.48mm^2$) than that of DES ($0.94{\pm}0.42mm^2$), indicating that paclitaxel has inhibitory effect on cell proliferation and prevent infiltration of restenosis into lumen of stent. Though it was not statistically significant, it showed that the extent of neointema of mid-region of stents was relatively higher than that of anterior and posterior region in parts of BMS as showing cross-sectional 2-D image. suggest that microCT can be utilized as an accessorial tool for pathological analysis.

Pyloric Obstruction with Advanced Gastric Cancer: Stent vs. Bypass (악성 위출구 폐쇄 치료의 선택: 스텐트 삽입술 혹은 수술적 우회술?)

  • Lee, Beom-Jae;Park, Jong-Jae
    • Journal of Gastric Cancer
    • /
    • v.9 no.1
    • /
    • pp.1-5
    • /
    • 2009
  • In the past, conservative bypass surgery was usually performed for palliation of malignant obstruction of the gastrointestinal tract. However, endoscopic stenting was developed recently, and technical advances and clinical experience have made it possible to establish stent implantation as one of the main treatment options. There are several advantages in stent implantation over bypass surgery, such as high feasibility and technical success rate, non-invasiveness, rapid symptomatic response, short hospitalization, and cost-effect benefits. Complications, such as stent ingrowth, stent injury by bile or acid, and migration, may occur and early re-insertion is frequently needed. Recently, diverse novel stents which are powered to predict stent migration or ingrowth have been developed and are being used in the clinical setting. In general, stent implantation is known to be beneficial in patients who are expected to survive <6 months, and surgical bypass may be more effective in patients who can survive >6 months. In this review, we have compared the technical feasibility, clinical outcomes, complications, and cost-benefit between stent implantation and bypass surgery, and determined the optimal treatment strategy in malignant upper gastrointestinal obstruction.

  • PDF

A Study of Drug Content and Cell Cytotoxicity of Paclitaxel-eluting Stents Coated with Various Biopolymer (다양한 생체고분자로 코팅된 Paclitaxel Eluting Stent의 약물함량과 세포독성 연구)

  • Kim, Dong-Gon;Shin, Il-Gyun;Kim, Gi-Han;Kim, Seong-Hyeon;Lee, Ju-Ho;Ki, Byoyng-Yun;Nah, Jae-Woon;Suh, Tae-Suk;Kim, Sang-Ho
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.125-131
    • /
    • 2009
  • In this study, the paclitaxel eluting stent (PES) was prepared by coating a biliary stent with paclitaxel using various biopolymer such as poly (vinyl acetate) (PVAc), poly (lactic-co-glycolic acid) (PLGA), Silicone rubber for restenosis prevention in gastrointestinal disease by a dip-coating method. Drug contents of PES were increased as surface area of stent, concentration and molecular weight of coating polymer increase. In $^1H-NMR$ specta, we know that drug did not change by confirming specific peaks of paclitaxel in PES. As shown in SEM image, PES prepared using various biopolymer is coated clearly and regularly except Silicone rubber coating polymer. In in vitro cell cytotoxicity test, bare stent showed low cytotoxic effect against CT-26 colon carcinoma cell line on 3 day. However, PES coated with PLGA 502H showed the highest cytotoxicity because PLGA 502H is biodegradable polymer and has less molecular weight than other coating polymer. These results suggest that PES coated various biopolymer can be prevented restenosis in gastrointestinal disease.

  • PDF

The Developing Trend in Bioresorbable Stent for Treatment of Coronary Artery Disease (관상동맥질환 치료를 위한 생체흡수형스텐트의 개발 동향)

  • Jeong, Gyeong-Won;Kim, Tae-Hoon;Nah, Jae-Woon;Park, Jun-Kyu
    • Applied Chemistry for Engineering
    • /
    • v.29 no.5
    • /
    • pp.497-502
    • /
    • 2018
  • The coronary artery disease (CAD) is rapidly increasing such as angina pectoris and atherosclerosis. The CAD is induce by cholesterol and calcium like plaque absortion to artery wall. The percutaneouss coronary intervention is non-invasive treatment that narrowed-artery is expand by using balloon catheter and bare metallic stent. The metallic stents have been effective in reducing the dead by coronary artery disease, but the permanent presence of the metallic stent has been associated with persistent inflammation, and incidence of late thrombosis. Therefore, development bioresorbable vascular scaffold (BRS) is rapidly increasing for treatment of long-term complications and arterial restenosis by permanentmetal prosthesis such as stent. The review discusses the BRS trend for successfully development.

Posterior Cerebral Artery Territorial Hemorrhage Including Thalamus After Carotid Artery Stenting : A Case Report (목동맥 스텐트 삽입술 후 시상을 포함한 후대뇌동맥 영역에 발생한 뇌출혈 : 증례보고)

  • Yi, SangHak;Hwang, Yong;Lee, Hak Seung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.456-461
    • /
    • 2018
  • Carotid artery stenting (CAS) has emerged as an alternative treatment for carotid stenosis in patients poorly suited for endarterectomy. Intracerebral hemorrhage following carotid revascularization (endarterectomy, angioplasty, artery stenting) is rare and thought to be related to reperfusion injury in most cases. Early experience suggests an increased incidence of hemorrhage following CAS as compared to endarterectomy. In this study, data were obtained through a case report on an 80-year-old male patient with cerebral infarction. The 80-year-old hypertensive man developed sudden monoparesis in the left arm. He underwent CAS for 90% stenosis of the left proximal internal carotid artery. Brain CT after procedure showed acute hematoma with left posterior cerebral artery territorial hemorrhage, including the upper thalamus with extended intraventricular hemorrhage (IVH). Since this hemorrhage occurred in vascular territory unlikely to have been supplied by the treated artery, this case suggests that the mechanism of intracerebral hemorrhage following CAS may in some cases be different from hyperperfusion hemorrhage classically described following endarterectomy.

A Case of Biphasic Flow-volume Loop in Left Mainstem Bronchial Stenosis (이상성 기류유량곡선(biphasic flow-volume loop)을 보인 결핵에 기인한 좌주기관지협착 1예)

  • Choi, Soo-Jeon;Jo, Moon-Suk;Lee, Hyuk-Pyo;Kim, Joo-In;Yum, Ho-Kkee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.2
    • /
    • pp.416-420
    • /
    • 1998
  • Flow-volume loop is known to be useful in the diagnosis of upper airway obstruction. In cases of tracheal obstruction, characteristic features such as fixed or variable upper airway obstruction patterns give clue to the diagnosis. But the flow-volume loop of unilateral mainstem bronchial stenosis is not known well. There is controversy in patterns of flow-volume loop in unilateral mainstem bronchial stenosis (restrictive pattern or biphasic pattern). We report a case of biphasic flow-volume loop in left mainstem bronchial stenosis(4-5 mm in diameter) as a sequela of endobronchial tuberculosis, which recovered normal flow-volume loop after metallic stent insertion and 2 months later showed reappearance of biphasic pattern because of restenosis of left mainstem bronchus due to growth of granulation tissue at the stent site.

  • PDF

Clinical Outcomes of Stent Thrombosis after Drug-Eluting Coronary Stent Implantation (약물방출 관상동맥 스텐트 시술 후 스텐트 혈전증 발생 환자의 임상경과)

  • Kim, In-Soo;Jeong, Myoung-Ho;Han, Jae-Bok;Jang, Young Ill;Jang, Seong-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.12
    • /
    • pp.880-892
    • /
    • 2013
  • Stent thrombosis after successful drug-eluting stent(DES) implantation has been reported in around 1% of patients in clinical trials. However, the increased risk of ST associated with DES remains a matter of concern. From 1 June 2003 to 30 June 2013, we investigated clinical characteristics, in-hospital outcomes in 10,273 patients who underwent percutaneous coronary intervention in the Heart Center of CNUH. Overall incidence of ST was 1.30% (134 patients). The incidence of ST according to the stent generations and the timing of ST (n=total, early vs. late vs. very late) were 0.79% (n=81, 26 vs. 12 vs. 43) in first-generation, 0.38% (n=39, 21 vs. 9 vs. 9) in second-generation and 0.14% (n=14, 8 vs 3 vs. 3) in third-generation, (p=0.70). The mortality from ST was significantly higher in early ST group compared to the late and very late ST groups (18.2% vs. 8.3% vs. 3.6%, p=0.042). Overall incidence of ST after DES implantation was 1.30% (134 patients). The in-hospital mortality was significantly higher in early ST group compared to the late and very late ST groups.

Development of Microneedles for Cardiovascular Drug Delivery (심혈관 질환치료용 약물전달을 위한 위한 마이크로 니들 개발)

  • Ryu, Won-Hyeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.122.1-122.1
    • /
    • 2016
  • 관상동맥 경화나 말초 혈관 동맥 경화 등이 발생한 경우 스텐트를 이용한 치료나 혈관 접합술(bypass grafting surgery)에 의한 치료를 하게 된다. 그러나 많은 경우 치료 부위에 발생한 혈관 조직에의 손상으로 인해 재협착(restenosis)이나 폐색(occlusion)이 일어나 환자의 생명을 위협하는 치명적인 결과를 유발하는 경우가 종종 발생한다. 이러한 재협착이나 폐색은 혈관민무니근세포(smooth muscle cells)의 이상성장(abnormal growth) 때문인데, 이를 억제하기 위한 다양한 약물이 개발되어 왔으나 치료 대상 부위에 높은 효율로 2~3 주간의 기간 동안 약물 전달하기가 어려운 실정이다. 최근 혈관접합 부위 (anastomosis site)등에 적용할 수 있는 메쉬나 실린더 형상의 약물전달 디바이스들이 개발되어 왔으나 약물 전달의 효율 등에서 더 개선이 절실히 필요한 실정이다. 본 발표에서는 혈관 외벽에 장착되어 혈관 중간막 (tunica media) 조직으로의 약물 전달 효율을 높이기 위해 마이크로니들(microneedles)을 이용한 디바이스들을 개발하고 약물 전달 성능과 치료효과를 소개하고자 한다. 열인장 공정 (thermal drawing)과 트랜스포 몰딩(transfer molding) 등의 마이크로 니들 제작공정을 설명하고 이를 바탕으로 제작된 커프(cuff) 형 및 유연 메쉬 (flexible mesh) 형의 디바이스 개발 과정을 소개하고자 한다. 특히, 이 디바이스들의 동물실험을 통한 약물 전달 효율의 향상 및 치료 효과의 증대에 대한 논의를 하고자 한다.

  • PDF