• Title/Summary/Keyword: 스테인레스 스틸

Search Result 147, Processing Time 0.031 seconds

Evaluation of frictional forces between orthodontic brackets and archwires (교정용 브라켓과 교정선 사이의 마찰력)

  • Jeong, Tae-Jong;Choie, Mok-Kyun
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.613-623
    • /
    • 2000
  • The purpose of this study was to amount of the frictional forces with the brackets and wires, ligation methods, dry/wet, offsets, interbracket distances, velocity and to compare them each other by different conditions. This study tested 0.018'x0.025' slot sized 8 types of orthodontic bracket systems and 0.016', 0.016'x0.022' sized stainless steel, NiTi, Cu-NiTi orthodontic wires. One cuspid bracket were positioned on the slide glass and archwire was engaged into bracket and ligated with elastomeric modules. The values of frictional forces were measured with the instron universal testing machine. The results were as follows; 1. Polycrystalline ceramic bracket had the highest mean frictional forces and followed and by ceramic reinforced plastic bracket, metal bracket, plastic bracket with metal slot, monocrystalline ceramic bracket, single bracket, self-ligating bracket, friction free bracket in descending order. The self-ligating bracket showed low frictional forces in the round wires and high frictional forces in the rectangular wires. 2. Stainless steel wires had the least frictional forces and followed by NiTi, Cu-NiTi wires in descending order. Round wires had lower frictional forces then that of rectangular wires. 3. The stainless steel ligation method had significantly greater mean frictional forces them the elastomeric module ligation method. 4. Artificial saliva statistically increased the frictional forces in stainless steel wire, NiTi wire and Cu-NiTi wire. 5. There was a statistically significant difference with offset change 6. There was no statistically significant difference with interbracket distance in stainless steel wires but a significant difference in NiTi wires as the interbracket was decreased. 7 There was no statistically significant difference with velocity change. From the above findings, self-ligating bracket, stainless steel wires and the elastomeric module ligation method might be effective than any other materials to reduce the frictional forces in the orthodontic treatment and can be correlated to clinical situations seen in orthodontic patient care.

  • PDF

Fabrication of Soda Borosilicate Class-Coated Electrostatic Chucks (소다붕규산염유리 도포형 정전척의 제조)

  • 방재철
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.9 no.1
    • /
    • pp.49-52
    • /
    • 2002
  • This study demonstrated the feasibility of tape casting method to fabricate soda borosilicate glass-coated stainless steel electrostatic chucks(ESC) for low temperature semiconductor processes. Glass coating on the stainless steel substrate was 125 $\mu\textrm{m}$ thick. The adhesion of glass coating was found to be excellent such that it was able to withstand temperature cycling to over $300^{\circ}C$ without cracking and delamination. The electrostatic clamping pressure generally followed the theoretical voltage-squared curve except at elevated temperatures and high applied voltages. The deviations at elevated temperatures and high applied voltages are due to increased leakage current as the electrical resistivity of glass coating drops.

  • PDF

PEFP 빔라인의 진공 펌프 설계를 위한 압력 프로파일 계산

  • Lee, Hwa-Ryeon;Kim, Han-Seong;Gwon, Hyeok-Jung;Jo, Yong-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.292-292
    • /
    • 2010
  • 양성자기반공학기술개발단에서는 100MeV와 20MeV의 가속기를 개발하고 있으며 빔 이용을 위하여 각 에너지에 5개의 빔라인을 구축 할 계획이다. 빔라인에는 각 마그넷과 빔 계측, 진공 등의 부품이 포함되어 있다. 본 연구에서는 빔라인의 기초 구성품인 진공 부품의 설계를 위한 압력의 계산을 수행하였다. 각 빔라인 재질에 따른 gas load는 표면의 아웃게싱이 주요하게 고려되었으며 고진공용 Cu gasket의 진공 leak는 거의 없다고 가정하였다. 재질은 스테인레스스틸과 알루미늄의 두 가지 경우를 사용하였으며 주 배기 펌프는 이온펌프로 펌핑 스피드 125L/s의 diode 타입이다. 빔튜브의 사이즈는 CF6"의 규격 플랜지를 기본으로 빔 사이즈가 고려된 여러 플랜지의 조합으로 내부 부피를 구할 수 있었다. 빔라인 뿐만 아니라 타겟룸에 위치되어지는 튜브를 합한 경우와 펌프의 개수를 다르게 하였을 때에도 길이에 따른 압력의 프로파일을 계산하였다. 빔을 분배해 주는 AC 마그넷 이전에 이온펌프 한 개를 위치하였을 때 스테인레스스틸 빔 튜브의 경우에 최대값은 1.3E-6 torr, 최소값은 1.7E-6 torr 으로 계산 되었다. 이 결과는 가속기의 아래쪽 3개의 빔라인을 동시에 배기하고 빔 조사가 가능하도록 운영되는 조건이며 운영 마진 2배를 고려한다고 하여도 최소 진공도는 3.4E-6 torr 이다. 이온펌프는 일반적으로 9.0E-6 torr 이하에서 사용이 가능하므로 이온펌프 1개의 진공도로도 운영에 무리가 없으며 이온펌프의 수가 증가됨에 따라서 최대 도달 압력이 낮아짐을 알 수 있다.

  • PDF

EFFICIENCY OF DENTIN CUTTING AND ROOT -END RETROCAVITY PREPARATION USING ULTRASONIC DIAMOND INSTRUMENTS AND THEIR INFLUENCE ON TOOTH STRUCTURE (초음파 다이아몬드 기구의 상아질 삭제 효과, 치근단 역충전 와동 형성효율 및 치질에의 영향)

  • Lim, Choon-Hee;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.54-67
    • /
    • 1998
  • The purposes of this study were to evaluate the efficiency of dentin cutting and root-end cavity preparation, and to determine the incidence of tooth crack when root-end retrograde cavity preparation was done with. ultrasonic diamond instruments. To evaluate the efficiency of dentin cutting, ultrasonic diamond and stainless steel instruments were applied to 20 exposed bovine dentin surfaces perpendicularly or parallely at the low, and medium power settings for 1 minute ($Miniendo^{TM}$, EIE, CA, U.S.A.). The resultant cavity depth was measured. To evaluate the efficiency of cavity preparation and to investigate the incidence of tooth crack, 165 mesiobuccal, distobuccal and palatal root-ends of extracted human maxillary first molars were resected by 3 mm perpendicularly to the long axis of tooth using a slow speed diamond saw after root canal preparation and filling. Retrocavities were prepared using a ultrasonic diamond instrument or a stainless steel one of the low- or medium power settings of 2 or 6. Time consumed and the number of strokes used for the cavity preparation were measured and the incidence of tooth cracks was evaluated under a stereomicroscope. The results were as follows: Both at the low and medium power settings, and both with perpendicularly- and parallely applied tips to dentin, diamond instruments showed higher dentin cutting efficiency than stainless steel ones did (p<0.01). When tips were applied to dentin perpendicularly, both diamond instrument and stainless steel one showed higher cutting efficiency with medium power setting than with low power one (p<0.01). Both at the low- and medium power settings, both diamond instrument and stainless steel one showed higher cutting efficiency when tips were applied perpendicularly to dentin surface than applied parallely (p<0.01). At the medium power setting, the number of stroke and time consumed were less with diamond instrument than with stainless steel one (p<0.05) for the retrograde cavity preparation. At the low power setting, diamond instrument induced less tooth cracks than stainless steel one did (p<0.01).

  • PDF

Preparation of Activated Carbon Screen Using Stainless Steel Mesh and Cellulose Fiber (스테인레스 망과 섬유를 이용한 활성탄소 망의 제조)

  • Shin, Jinhwan;Kim, Taeyoung;Jeoung, Youngdo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.3
    • /
    • pp.45-50
    • /
    • 2008
  • In this work, stainless steel mesh-supported activated carbons were prepared using phenolic resin and cellulose fiber. $ZnCl_2$ was used as a activation reagent in this work. $ZnCl_2$-chemical activation method has been proposed to produce highly porous activated carbons. The objectives of this work were to develop an optimal condition for manufacturing activated carbon assemblies screen from stainless steel mesh and phenolic resin. The iodine number was more increased over activation temperature of $450^{\circ}C$. Iodine number was 657 mg/g at activation temperature of $550^{\circ}C$, penolic resin concentration 20% and $ZnCl_2$ concentration 15%. Iodine number was 1359.4 mg/g when 10% cellulose added to these conditions.

  • PDF

LOMI 제염제의 전기화학적 제조시 전극재료의 영향

  • 박상윤;문제권;심준보;오원진
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.980-986
    • /
    • 1995
  • LOMI(Low Oxidation State Metal Ion) 재염제의 구성성분 중 가장 중요한 성분인 $V^{2+}$-formate 를 formic acid 내에서 VO$^{2+}$ 이온을 전기화학적으로 환원시켜 제조하였다. 산성용액 내에서의 전기화학반응은 목적반응인 바나듐이온의 환원반응과 부반응인 수소이온의 환원반응이 경쟁적으로 일어나며 이는 전극재료의 영향을 크게 받는다. 따라서 본 연구에서는 Cyclic Voltammetry(CV) 방법으로 여러 가지 전극재료의 특성을 조사하여 공업적 활용이 가능한 전극으로 수은, 납 및 스테인레스 스틸을 선정하였다. 선정된 전극을 이용하여 제조실증시험을 수행한 결과 소량의 고순도 제염제의 제조에는 수은전극을 대략의 공업용 제염제가 필요한 경우에는 스태인레스 스틸 전극을 음극재료로 사용하는 것이 효과적임을 알 수 있었다.

  • PDF

Characteristics of TiN/Al, TiCN/Al films deposited by DC reactive magnetron sputtering (DC 반응성 마그네트론 스퍼터링법으로 TiN/Al, TiCN/Al 박막의 물성 평가)

  • Lee, Hyeon-Jun;Song, Pung-Geun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.11a
    • /
    • pp.107-107
    • /
    • 2012
  • 연료전지 분리판용 모재로서 사용되고 있는 스테인레스 스틸에 대해서는 많은 연구가 진행되어 왔으나, 알루미늄은 거의 연구가 진행되지 않고 있다. 따라서 이번 연구는 DC 반응성 마그네트론 스퍼터링법으로 알루미늄 기판 위에 TiN, TiCN 박막을 반응성 가스 유량별로 증착하여, 기계적 특성 및 내부식성 특성을 비교 검토하였다.

  • PDF