• Title/Summary/Keyword: 스크린도어

Search Result 87, Processing Time 0.026 seconds

Commercialization of Integrated DCU for the Platform Screen Door (승강장 스크린도어를 위한 통합형 제어기의 상품화)

  • Woo, Chun-Hee;Kim, Jin-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.3
    • /
    • pp.110-113
    • /
    • 2011
  • Platform Screen Door, PSD, is a device that seeks to prevent accidents with regards to falling off the platform and getting trapped between the trains, achieve improvements on the cleanliness of the air, address the accessibility issue of the disabled and the elderly and provide fresher environment on the platform in general. This is achieved by preventing health hazards and accidents from occurring through installation of fixed and moving doors between rail, tram and subway platforms and the railway. Domestic firms have achieved domestic production to a large degree in various Control Units including the Overall Control Unit and RF devices through investments in technology. Despite this, full domestic production of the core of the PSD system, Door Control Unit, DCU, is not yet achieved, having to install PSDs in a relatively short period of time. Currently, controllers with DC motors are developed for installation or one is faced with having to import foreign produced controllers. In this research, the control unit prototype using the BLDC motor was domestically produced. The performance of the control unit was rigorously tested through installation on Eun-Ha Rail on Wol-Mi Island.

A Study on the Unification of the Grounding System of SeoulMetro (서울메트로 접지설비 표준화 방안 연구)

  • Kim, Gyun-Sig;Park, Han-Yeong;Back, Yu-Ho
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1027-1036
    • /
    • 2007
  • Since the opening of the Seoul Metro in 1974, the electric railway passengers have been increased rapidly and as the advanced equipments(OC,PSD) were introduced, additional power facilities were built in a limited area for the comfortable transportation environment. Present grounding system were built according to old Electric equipment standards and all the electric signal, communication and electronic equipments were built only for the purposes of protecting building structure, people and electronic equipments. Grounding system which was additionally built in the limited area caused problems with the building structure and it caused secondary damages when earth fault happens. One of the problems is grounding system of the building structure; grounding system does not work properly since grounding equipments are not separated from each other. So, existing grounding system needs to be improved and unified grounding system in the building should be established. The purposed of this study is to analyze all the grounding systems that had been built in different year and to establish unified grounding system of Seoul Metro.

  • PDF

Fire Risk Assessment for Subway Station According to Supply and Exhaust Conditions (지하철 승강장 급배기 조건에 따른 화재 위험성 평가)

  • Kim, Ha-Young;Rie, Dong-Ho;Kim, Jung-Yup
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.29-34
    • /
    • 2008
  • In this research, to establish the emission for the people who are clearing out, through the numerical analysis using the CFD model, the dangerousness has been investigated in the various emission conditions in a station platform. As a result of research, it is found out that the temperature variation falls between 65.37% and 74.97% to compare without installation of platform screen doors. In the addition, with the supply mode or push-pull mode, the warm current is generated in the platform so the temperature and the layer of smoke are stirred up and felled off. It will make the dangerousness when the people escape. Therefore, when the capacity of emission and the space of platform is set up, the design regards the properties of the fire emission.

A Study of Smoke Exhaust Facility Operation of Subway Platform with Installation of Platform Screen Door (승강장 스크린도어 설치에 따른 배연설비운영에 대한 연구)

  • Rie, Dong-Ho;Ko, Jae-Woong;Kim, Ha-Young
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.1 s.73
    • /
    • pp.35-40
    • /
    • 2006
  • A study on fire phenomena in a subway transit mass station has been carried out as a part of disaster prevention plan at the subway station. The ventilation facilities installed in both the platform and the trackway are designed to convert into a smoke exhaust system in emergency situation, creating such an environment as necessary for evacuation. 3 dimensional Numerical Simulations based on the CFD are carried out using a simulation tool, Fire Dynamic Simulator. Additionally, four different vent modes are made and performances are compared with the original design mode and each other to find better operation of vents at both the platform and the trackway in case of fire. From the result, an vent operational characteristics under the condition of installed PSD is clarified for the effective smoke and heat removal from the platform area compared with non installed PSD.

A Study on Signal Interlocking for Screen Door System (스크린도어 시스템 제어를 위한 신호 인터로킹 연구)

  • Kang, Dae-Yun
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.811-820
    • /
    • 2006
  • The Platform Screen Door system(PSD) is scheduled to be installed on the platform of some subway stations in Seoul, Pusan, Kwang-Ju, Daejun and Daegu and all stations of Seoul Subway No 9. will equipped with PSD. On the other hand Seoul Metropolitan Rapid Speed(SMRT) that has operated the train automatically had finished the basic desic design and the execution drawing of PSD and installed successfully the PSD on the platforms in the Kimpo Airport station in Subway Line No 5. at dec. 2005. The exhibition operations of PSD has made the major contribution to build up the safe and optimum subway for the increasing customers. Nowadays PSD has operated on ATO sections and ATS sections. But in the case of closing the door manually in ATO sections, it would be delayed about 5 seconds in closing the door of PSD. Although the interface of PSD, train and the signal system is established automatically, we have to supplement technically on the interface between train, PSD and the ground signal interface equipments. Therefore I will center on the optimizing methods about the interfacing system between the train and the PSD, train and the signal system to overcome the above problems in this study.

  • PDF

A Study on The Sign System Following Installation of Screen Doors in Subway Platforms (지하철 승강장 스크린도어 설치에 따른 사인시스템에 관한 연구)

  • Shin, Hong-Jae;Park, Hee-Myeon
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1567-1574
    • /
    • 2006
  • To prevent safety accidents such as injury or death from falling by blocking platforms from trains, the Seoul Metropolitan Subway Corp. have gradually installed screen doors in platforms of 115 subway stations in Seoul on lines 1, 2, 3, and 4. Installation in nine areas among those has been completed and screen doors are being operated as a model operation. Traffic signs should be clear for users. The essential functions of signs should be fully investigated from the aspect of user as well as the visual beauty and recognition. Signs should be able to provide users with information regarding location, position, directions, etc. Particularly, safety and convenient signs should be visually and sensually correlated. However, the entire screen doors in platforms installed in line 2 subway in Seoul are used for commercial advertisement, consequently, the functions and roles as public signs are not fulfilled aggravating inconvenience for users. In this study, cases have been studied to investigate requirements for user-oriented sign system in platform and public sign space to fulfill the functions of sign system in platform. Using an anthropometry approach, the study aimed to obtain the space to install the sign system and to systemize necessary and sufficient conditions for user-oriented system for platform in which screen doors have been installed using. The study suggests fundamental information to obtain the space of public sign system on the entire screen door.

  • PDF

Simulation of Fluid Flow Inside the Subway Station with PSD (PSD 설치에 따른 지하철 내부 유동장 계산)

  • Jeong, Hae-Kwon;Ha, Man-Yeong;Kim, Kyung-Chun;Jeon, Chung-Hwan;Choi, Ho-Jin;Joo, Jae-Chun;Mun, Jeong-Man;Hwang, Seong-Ki
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1430-1435
    • /
    • 2004
  • According to the development of the economy and to the improvement in life quality, it is increased for the desire for the comfortable circumstance in the underground subway station. And recently, an accident, fire, suicide and so on have been risen. An advanced countries have introduced PSD, and they satisfies with the effect of PSD. The optimum design standard to set up PSD have to satisfy the by train wind beyond the maximum static pressure. This paper includes the maximum static pressure what can be applied to the PSD installation design.

  • PDF

Development of High Reliability Monitoring and Control System for Platform Screen Door (승강장 스크린 도어(PSD)에 대한 고 신뢰성의 감시 및 제어 시스템 개발)

  • Kim, Jin-Sik;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.158-162
    • /
    • 2010
  • PSD is automatically opened and closed when subway train arrive on the station. This system was designed to control electric automatic system. These doors will provide passenger safety, energy saving and a good environment in subway. The monitoring and control systems of PSD are configured so that they can be operated in automatic mode in connection with ATO through the composite control panel in the station control room. The objective of this paper is to obtain high reliability that is essential for monitoring and control systems of PSD. The power supply is based on protection circuit using DC power bridge from two UPS. Also, stable communication system consists of CAN communication line redundancy and RF cross protection algorithm. Monitoring state display results show the validity of the proposed high reliability monitoring and control systems of PSD.

A study of improvement of uncertainty by repeated measurement for PSD(Platform Screen Door) Performance Test (승강장 스크린 도어 시스템 특성 시험의 반복 측정에 의한 불확도 개선 고찰)

  • Ohn, Jung-Ghun;Kim, Myung-Yong;Yun, Myung-Sang;Kim, Won-Kyong;Won, Si-Tae
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1671-1674
    • /
    • 2007
  • A PSD system has a lot of characteristic for safety. Trust of performance test is very important. But PSD performance test has an effect on trust by proficiency of test staff because it is difficult to automate. In that specially the effort test, manual opening and shutting test and abrasion measurement, test staff is demanded for proficiency. Therefore the paper repeated measurement in same condition and studied proficient factor of examiner according to increased measurement counter. As a result, measurement uncertainty has improved.

  • PDF

Modeling of BLDC Motor Driving System for Platform Screen Door Control applied Fuel Cell Power Generation System (연료전지 발전시스템을 이용한 승강장 스크린 도어 제어용 BLDC 전동기 구동 모델링)

  • Yoon, Yong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.6
    • /
    • pp.968-974
    • /
    • 2017
  • In this paper, modeling of brushless DC motor (BLDC) driving system for platform screen door control applied fuel cell power generation system has been proposed. At first the system configuration and operational principle of the developed fuel cell simulator has been investigated and the design of BLDC motor driving system is studied and the overall performance and dynamics of the proposed system could be effectively examined by simulation. PSIM simulation program is implemented to verify the performance and compatibility of the fuel cell power generation system and BLDC motor control system modeling.