An Experimental Study on the Elasto-Plastic Behavior of High Strength Column to Beam Welded Connection (고강도강 기둥(SM570) 보 용접접합부의 탄소성거동에 관한 실험적 연구 -스캘럽상세와 패널강성을 중심으로-)

  • Kim, Jong Rak;Kim, Sung Bae
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.5 s.48
    • /
    • pp.487-494
    • /
    • 2000
  • This paper intends to propose design information with the result or comparing the deformation capacity with different panel stiffness specimens and estimating the plastic deformation capacity, toughness and strength of welded joint connection according to the different scallop types. The test results of the beam to column unit structure are as follow: the non-scalloped and the low stiffness panel specimen have more desirable result values than the scalloped and the high stiffness one in plastic deformation. Comparing the scallop types shows very unlikely tendency as follows, second cracking occurs at the very edge of scallop in the scalloped specimen otherwise cracking occurs bond area of welded beam flange in the non-scalloped one.

  • PDF

Evaluation of Fatigue Strength in Scallop at Field Bolted Joints of Longitudinal Rib and Deck Plate in Orthotropic Steel Decks (강바닥판 데크플레이트와 종리브 현장연결 스캘럽부의 피로강도 평가)

  • Choi, Dong Ho;Choi, Hang Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.6
    • /
    • pp.683-690
    • /
    • 2002
  • Static and fatigue tests were performed to evaluate fatigue strength in scallop at field bolted joints of longitudinal rib and deck plate in orthotropic steel decks. Numerical parametric studies using finite elemtn analysis were also conducted to show the influence of parameters such as length and radius of scallop, and thickness of deckplate on the stress concentration at the scallop. In the low stress level, fatigue tests yielded cracks at the scallop while in the high stress level, catastrophic failure of longitudinal rib occurred following the failure of handhole cover plate. Fatigue strength was compared with JSSC specification and the predicted S-N curves using Shigley and Juvinall methods, and a satisfactory result was obtatined.

Study on Elasto-Plastic Behavior of Column to Beam Connection with 600MPa High Performance Steel(SM 570 TMC) (기둥-보 용접접합부의 보단부 스캘럽형상과 탄소성 거동에 관한 실험적 연구 - 600MPa(SM570TMC)의 경우 -)

  • Kim, Jong Rak;Kim, Seung Bae;Kwon, June Yeop
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.6
    • /
    • pp.691-700
    • /
    • 2008
  • Contemporary architectural structures have diverse and complex forms. Such structural variety demands requisite performance from the connections in the steel structure so that the latter could resist a horizontal force, such as an earthquake. The connections are the all-important components that create the discontinuous form and that support stress concentration, determining the stiffness and toughness of the entire steel frame. In this study, a real-scale column-to-beam connection was constructed in the 600MPa-grade high-strength and high-performance steel, to test its behavior. Its material and welding characteristics were examined in this study, and its structural performance was analyzed by conducting seismic-resistance tests on the full-scale, cross-shaped column-to-beam welded connections with non-scallop, ordinary-scallop, and reinforced-scallop details. The weld ability of the high-strength, high-performance steel was also evaluated, and data regarding the seismic design for practical application were provided.

Stress Concentration at Connection and Cut-Out Parts according to Existence of Scallop and Diaphragms on Orthotropic Steel Decks (강바닥판의 스캘럽·다이아프램 설치 유무에 따른 교차부·컷아웃부 응력집중)

  • Shin, Jae Choul
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.3
    • /
    • pp.289-299
    • /
    • 2006
  • Orthotropic steel decks are manufactured by welding thin plates therefore it is inevitable that there are abundant works of welding process. On connection of transverse rib web, crossing point of longitudinal rib, transverse rib and deck plate and cut-out parts of transverse rib are the significant position of stress concentration phenomenon because of out of plane and oil-caning deformation caused by longitudinal rib distortion with shear force and distortion. In order to reduce the stress concentration phenomenon and improving fatigue performance at the crosing point and cut-out, structural analysis was performed considering the existence of scalop at conection and diaphragm which have same plane with transverse rib placed inside of longitudinal rib. Result o f the analysis show that there are the largest efect of stres concentration reduction when diaphragms are installed without scallop at connection, therefore these detail can improve the fatigue performance of orthotropic steel decks.

An Experimental Study on Behavior of Field Splice Joints of Longitudinal Rib in Orthotropic Steel Decks (강상판 종리브 현장연결부의 실험적 거동 특성)

  • Choi, Dong Ho;Choi, Hang Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.6
    • /
    • pp.621-629
    • /
    • 2001
  • This study consists of static and fatigue tests to evaluate the behavior on the field splice joint of longitudinal rib in orthotropic steel deck specimens. Specifically, static and influence surface tests are performed for the stress distribution at the scallop area and high-strength bolt connection of longitudinal rib to examine the existence of handhole cover plate and the effect of eccentric loads. The ultimate strength of the field splice joint of longitudinal rib is obtained. In fatigue tests, cracks are observed at the scallop in the lower level test and the catastrophic failure of longitudinal rib is occurred following the failure of handhole cover plate in the higher level test. This study gives a basis for the better understanding of the field splice joint of longitudinal rib.

  • PDF

A Study on the Fatigue Design of Joint Detail of Vertical Stiffener in Two-Girder Bridge (2거더교의 수직보강재 연결상세부의 피로설계에 관한 연구)

  • Kwon, Soon Cheol;Kyung, Kab Soo;Park, Jin Eun
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.1
    • /
    • pp.93-103
    • /
    • 2009
  • Two-girder bridge is composed of primary members such as deck slab and main girder, and secondary member such as cross beam, vertical and horizontal stiffeners etc,. Two-girder bridge is prescribed as a non-redundant load path structure in the ASSHTO and the Korean Highway Bridge Design Code. Such structure is that if one girder is damaged, problems of function and safety of the bridge are caused. From the reasons, fatigue cracks in two-girder bridge can affect safety of the bridge seriously. Therefore, in this paper, fatigue evaluation was performed at connection parts of vertical stiffener and web with radius of curvature of scallop of vertical stiffener and thickness of web as variables. Such joint is known as a detail which has high possibility of fatigue crack in the bridge. Based upon the analytical results, preferable joint detail in terms of fatigue and simple empirical formula for fatigue evaluation of the detail were suggested.

Improvement of the Design and Construction Technique of Orthotropic Steel Deck Bridges : Fatigue Strength of Three Dimensional Full-scaled Model (강바닥판교의 설계 및 시공성 향상방안 : 강바닥판교 3차원 실물 모형체의 피로강도)

  • Oh, Soon Taek
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.1
    • /
    • pp.23-32
    • /
    • 2006
  • This study was conducted to improve the design and construction technique of orthotropic steel-deck bridges. After conducting an F.E.M. analysis of the various rib types of the connection details, static and fatigue tests were conducted, using a three-dimensional, full-scaled, orthotropic, steel-deck-plate model with internal diaphrams, to check the fatigue strength depending on the types of details. The model structure was made of two types of longitudinal ribs: the domestic standard and the European rabbit types. The fatigue strength of the steel-deck system was found to have improved through the installation of an internal diaphram, as no cracks were found on the bottom round part of the scallop with a diaphram. There were no differences between the domestic and the European types of details in terms of strength may be partially influenced by the shape of the scallop and by the installation of an internal diaphram, but it can be improved more significantly according to the quality of the welding that will be done.

The Effect of Diaphragm inside Trough Rib on Fatigue Behavior of Trough Rib and Cross Beam Connections in Orthotropic Steel Decks (강바닥판 종리브와 횡리브 교차부의 피로거동에 대한 종리브내 다이아프램의 영향)

  • Choi, Dong Ho;Choi, Hang Yong;Choi, Jun Hyeok
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.3 s.46
    • /
    • pp.239-250
    • /
    • 2000
  • This study investigates the mechanical behavior on trough rib to crossbeam joint in orthotropic steel plate decks, specially emphasizing on the effect of diaphragm inside trough rib on the fatigue behavior of slit by static and fatigue tests. In particular, the effects of diaphragm on in-plane stress and out-of-plane stress, stress concentration, propagation of fatigue cracks at the silt are studied. With the result of experiment and numerical analysis, we have estimated the fatigue strength using the nominal stress and hot-sport stress. The details with diaphragm have occurred about 50% stress reduction at trough rib part of trough rib to crossbeam joint than the detail without diaphragm, however, the lower parts of crossbeam have occurred much more stress. Initial crack size or slit have an considerable influence on the propagation of fatigue cracks due to V-notch. The fatigue strength category of the details without diaphragm has higher value than fatigue limit, whereas that of the details with diaphragm is estimated lower than fatigue limit.

  • PDF

Seismic Design and Testing of Reduced Beam Section Steel Moment Connections with Bolted Web Attachment (웨브를 볼트로 접합한 보 플랜지 절취형(RBS) 철골모멘트접합부의 내진설계 및 성능평가)

  • Lee, Cheol Ho;Kim, Jae Hoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.6 s.79
    • /
    • pp.689-697
    • /
    • 2005
  • Recent test results on reduced beam section (RBS) steel moment connections show that specimens with a bolted web connection tend to perform poorly due to premature brittle fracture of the beam flange at the weld access hole. A review of previous test results indicates that the higher incidence of base metal fracture in bolted-web specimens is related, at least in part, to the web bolt slippage and the high stress concentration at the weld access hole with the lowest material toughness. The practice of providing web bolts uniformly along the beam depth based on the classical beam theory is questioned in this paper. A new seismic design procedure, which is more consistent with the actual load path identified from the analytical and experimental studies, is proposed together with improved connection details. A test specimen designed following the proposed procedure exhibited a cyclic connection rotation capacity sufficient for special moment frames without fracture.

An Experimental Study on the Hysteresis Behavior of WUF-B Beam-Column Connection using SN Steel (건축구조용강재(SN490) 조립 H형강 기둥-보 접합부의 이력거동에 관한 실험적 연구)

  • Kim, Sun Hee;Lee, Seong Hui;Kim, Jin Ho;Kim, Dae Jung;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.6
    • /
    • pp.807-815
    • /
    • 2008
  • The brittle failure where is occurred the welding position of column-beam flange of WUF-B connection that consider about a seismic detail possess a superior ductility capacity before Northridge earthquake 1994, require newly study about WUF-B connection. SAC Steel Project suggests a seismic detail to FEMA-350 by supporting of FEMA. It revise shape of weld access holes of WUF-B connection, welding processand welding material etc, In spite of these revision, AISC Seismic Provisions (2005) prescribe WUF-B connection using an only OMF. Recently in Korea, as the earthquake of about seismic intensity 5 occur, the necessity of revision for connection seismic detail comes to the front in Korea and FEMA-350 connection seismic details are going to include in KBC-2008 as it is. In this study, two column-beam connection specimens were marked by using SM490, SN490 built-up H-section, and based on WUF-B detail prescription of FEMA350. The parameters of the specimens are types of steel (SM, SN), and evaluate the capacities of structure and seismic by experiment. Finally we confirm a superior ductility capacity aboutspecimens JB-1 and JB-2, using SM490 and SN490,and these specimens had sufficient OMF and SMF seismic capacity, as indicated in AISC Seismic Provisions (2005).