Abstract
The brittle failure where is occurred the welding position of column-beam flange of WUF-B connection that consider about a seismic detail possess a superior ductility capacity before Northridge earthquake 1994, require newly study about WUF-B connection. SAC Steel Project suggests a seismic detail to FEMA-350 by supporting of FEMA. It revise shape of weld access holes of WUF-B connection, welding processand welding material etc, In spite of these revision, AISC Seismic Provisions (2005) prescribe WUF-B connection using an only OMF. Recently in Korea, as the earthquake of about seismic intensity 5 occur, the necessity of revision for connection seismic detail comes to the front in Korea and FEMA-350 connection seismic details are going to include in KBC-2008 as it is. In this study, two column-beam connection specimens were marked by using SM490, SN490 built-up H-section, and based on WUF-B detail prescription of FEMA350. The parameters of the specimens are types of steel (SM, SN), and evaluate the capacities of structure and seismic by experiment. Finally we confirm a superior ductility capacity aboutspecimens JB-1 and JB-2, using SM490 and SN490,and these specimens had sufficient OMF and SMF seismic capacity, as indicated in AISC Seismic Provisions (2005).
Keywords
Moment resistanceframe; WUF-B Connection; SN490; Seismic Behavior;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 권기업, 한상환 WUF-B접합부의 내진성능 평가, 대한건축학회, 2003
2 이세정, 이성희, 김진호, 채흥석, 최성모,(2007) 삼각판으로 보강된 엔드플레이트 기둥-보 접합부의 연성능력과 구조내력 개선 연구, 강구조학회학술발표대회
3 한상환, 정지은, 문기훈(2007), 지진 하중에 대한 WUF-B 접합부 골조의 성능평가, 대한건축학회논문집 구조계, v.23 no.9, pp.115-123
4 FEMA(2000), Recommended seismic design criteria for new steel moment-frame buildings; FEMA-350, SAC Joint Venture
5 AISC(2005), Seismic provisions for structural steel buildings, American Institute of Steel Construction Ins
6 김선희, 이성희, 채흥석, 김용환, 촤성모(2007), 고연성 엔드플레이트 항복형 철골기둥-보 접합부의 설계 개념과 절차, 대한건축학회 학술발표대회 논문집, pp.13-16
7 강구조내진기준(2008 안) 한국강구조학회 2007. 06
8 FEMA(2000), State of the Art Report on Connection Performance; FEMA-355D, SAC Joint Venture
9 한상완, 권건업(2003), WUF-B 접합부의 내진성능 평가, 대한건축학회논문집 구조계, v.19 n.11, pp.33-40
10 이성희, 이세정, 채흥석, 김진호, 최성모(2008), SN 강재를 이용한 엔드플레이트 항복형 보-기둥 접합부의 구조 거동, 강구조학술발표대회
11 한상완, 문기훈, 정지훈, 이기학(2007), Post-Northridge WUF-B 접합부 골조의 내진 성능 평가, v.19 n.6, pp. 751-760