• Title/Summary/Keyword: 쉐브론각

Search Result 6, Processing Time 0.024 seconds

Investigation of Flow and Heat Transfer Characteristics of Plate Heat Exchanger Taking into Account Entrance Effects and Variation in Corrugation Height (입구영향 및 주름높이의 변화를 고려한 판형열교환기의 유동 및 열전달 특성)

  • Moh, Jeong-Hah
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.11
    • /
    • pp.965-973
    • /
    • 2010
  • Numerical analysis has been carried out to investigate the heat transfer characteristics of a plate heat exchanger. The multi-cell models with inlet part and outlet part are used for performing numerical simulation. The plate heat exchanger is characterized by chevron angle of $15^{\circ}$, corrugation pitch of 24mm and corrugation height 6~12mm. The length of the inlet-part considered in the analysis ranges from 24.8 to 124mm and Reynolds numbers range from 1,000 to 10,000. The correlations such as friction factor and Colburn factor are compared with previous experimental data. The results can be utilized for designing the plate heat exchanger.

Numerical Simulation of the Fully Developed Flow and Heat Transfer of a Plate Heat Exchanger Taking into Account Variation in the Corrugation Height (주름높이의 변화를 고려한 판형열교환기의 완전발달유동 및 열전달 수치해석)

  • Moh, Jeong-Hah
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • Numerical analysis has been carried out to investigate the fully developed flow and heat transfer characteristics of a plate heat exchanger. Multi-cell models with an inlet part and outlet part are used to perform the numerical simulation. The plate heat exchanger is characterized by a chevron angle of $20^{\circ}$ and a P/H ratio of 2.0~4.0. The working fluid is water and the Reynolds numbers range from 300 to 1,500. The correlation is given in the form of $f=CRe^m$ for the friction factor and $j=CRe^m$ for the Colburn factor. It is found that the fully developed flow starts from the third cell and the Nusselt number increases with decreasing P/H ratios.

Performance Evaluation of plate heat exchanger with chevron angle variation (쉐브론 각도변화에 따른 판형 용액열교환기의 성능평가)

  • Kwon, Oh-Kyung;Cha, Dong-An;Yun, Jae-Ho;Kim, Hyo-Sang
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2363-2368
    • /
    • 2008
  • The objectives of this paper are to measure the heat transfer and pressure drop of the plate heat exchangers for absorption system applications. Three types of plate heat exchangers with different chevron angles are tested in the present experiment. Heat transfer and pressure drop performance of plate heat exchangers are measured in various operating conditions, and compared each other. The results show that the heat transfer rate of high theta ($120^{\circ}$) and mixed theta plate heat exchanger increases about 118% and 98% at the solution flow rate 350 kg/h compared to that of low theta ($60^{\circ}$), respectively. The effectiveness of high theta was evaluated about $0.70{\sim}0.83$ in this experimental range.

  • PDF

An Experimental Study on the Performance of a Brazed Plate Heat Exchanger (용접식 판형 열교환기의 성능에 관한 실험적 연구)

  • 김종하;권오경;윤재호;이창식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.1
    • /
    • pp.83-90
    • /
    • 2002
  • An experimental study on the performance evaluation of a brazed plate heat exchanger with 10USRT of normal cooling capacity has been carried out. In the present study, a brazed plate heat exchanger was tested at a chevron angle $25^{\circ}$with refrigerant R-22. Refrigerant mass flux was ranged from 23 to 58 kg/$m^2$s in condensation, and from 22 to 53 kg/$m^2$s in evaporation. The heat transfer coefficients and pressure drops are increased as the mass flux increases. The water side pressure drop is increased as the cooling water flow rate and chilled water flow rate increase, while mass flux has little effect. It is also shown that the system performance can be improved by enlarging condensation heat transfer area.

Study on Design Factor and Design-code Development for Plate Type Heat Exchangers (판형 열교환기의 주요 설계인자와 설계프로그램 개발에 관한 고찰)

  • Ko, Jea-Hyun;Park, Kweon-Ha;Song, Young-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.8
    • /
    • pp.1003-1009
    • /
    • 2012
  • Heat exchanger has been widely used in the industry which needs energy transport, and the application of the plate type heat exchanger having high efficiency has been greatly increased. In this study main design parameters are analyzed and new equations are induced. The induced formulation was compared with a commercial program in order to design an optimal heat exchanger. The equations of heat transfer coefficient and pressure drop for Chevron angles are introduced as functions of Reynolds number. The program implemented the equations is tested with Chevron angle variation. The results show that the convective heat transfer coefficients take errors within 8% and the pressure drops have errors within 5% in the analysis conditions.

Performance Evaluation of Plate Heat Exchanger with Chevron Angle Variations (쉐브론 각도변화에 따른 판형 고온 용액열교환기의 성능평가)

  • Kwon, Oh-Kyung;Cha, Dong-An;Yun, Jae-Ho;Kim, Hyo-Sang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.7
    • /
    • pp.520-526
    • /
    • 2009
  • The objectives of this paper are to measure the heat transfer and pressure drop of the plate heat exchangers for absorption system applications. Three types of plate heat exchangers with different chevron angles are tested in the present experiment. Heat transfer and pressure drop performance of plate heat exchangers are measured in various operating conditions, and compared each other. The results show that the heat transfer rate of high theta ($120^{\circ}$) and mixed theta plate heat exchanger increases about 118% and 98% at the solution flow rate 350 kg/h compared to that of low theta ($60^{\circ}$), respectively. The effectiveness of high theta was evaluated about $0.53{\sim}0.85$ in this experimental range. The experimental correlations of the Nu and f were developed with error bands of ${\pm}7%$ and ${\pm}12%$.