• Title/Summary/Keyword: 순환정지

Search Result 166, Processing Time 0.028 seconds

Analysis on Temperature Change of Ground by Long-term Performance of Energy Pile (수치해석을 통한 에너지 파일의 장기 운용에 따른 지반의 온도변화 분석)

  • Kim, Beom-Jun;Yune, Chan-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.10
    • /
    • pp.5-15
    • /
    • 2019
  • In this study, to investigate the effect of long-term performance of energy pile on ground temperature, a numerical analysis was conducted by simulating the ground where an energy pile was installed. In the analysis, a changing distance from the outer perimeter of a heat circulation pipe to the surface of concrete pile for an intermittent operation (8-hour operation, 16-hour stop) was considered. Simulation results showed that long-term heat exchange under the intermittent operation of energy pile reduced a thermal recovery in the ground and increased the ground temperature through the residual thermal energy. In addition, the ground temperature became higher as it got closer to the energy pile and increased as the distance from the outer perimeter of heat circulation pipe to the surface of concrete pile decreased.

Experimental Fetal Cardiopulmonary Bypass in the Fetal Lamb Model (태아양 모델을 이용한 실험적 태아 심폐우회술)

  • 이정렬;임홍국;김원곤;김종성;최정연;김용진
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.495-503
    • /
    • 1999
  • Background: We tested the technical feasibility of fetal cardiac bypass and collected baseline data on the fetal hemodynamics and placental functions related to the cardiopulmonary bypass in the fetal lamb model. Material and Method: Eleven fetuses at 120 to 150 days of gestation were subjected to bypass via trans-sternal approach with a 12 G pulmonary arterial cannula and 14 to 18 F venous cannula for 30 minutes. All ewes received general anesthesia with ketamine. In all the fetuses, no anesthetic agents were used except muscle relaxant. Eight served as a group in which placenta was excluded from the extracorporeal circulation by clamping the umbilical cord during the bypass(the oxygenator group) and in the remaining three, the placenta worked as the only source of oxygen supply(the placenta group). Observations were made every 10 minute during a 30-minute bypass and 30-minute post bypass period. No prostaglandin inhibitors were used both in ewes and in fetuses. Result: Weights of the fetuses ranged from 1.9 to 5.2 kg. In the oxygenator group, means of arterial pressure, PaO2, atrial pressure, heart rate, and bypass flow rate ranged 69.8 to 82.6 mmHg, 201.7 to 220.9 mmHg, 4.1 to 4.3 mmHg, 169 to 182/min, and 140.3 to 164.0 ml/kg/min, respectively during bypass, but rapid deterioration of the fetal cardiac functions and the placental gas exchange was observed after the cessation of bypass. In the placenta group, means of arterial pressure decreased from 44.7 to 14.4 mmHg and means of PaCO2 increased from 61.9 to 129.6 mmHg during bypass. Flow rate was suboptimal(74.3 to 97.0 ml/kg/min) during bypass. All hearts fibrillated immediately after the discontinuation of bypass. Conclusion: In this study, the technical feasibility of fetal cardiopulmonary bypass was confirmed in the fetal lamb model. However, further studies with modifications of the bypass including an addition of prostaglandin inhibitor, an application of the total spinal anesthesia on the fetus, a creation of more concise bypass circuit, and a use of active pump are mandatory to improve the outcome.

  • PDF

Noncardiac Applications of Cardiopulmonary Bypass (비심장질환에서의 심폐바이패스 적용)

  • Kim, Won-Gon;Oh, Sam-Sae;Kim, Ki-Bong;Ahn, Hyuk;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.31 no.9
    • /
    • pp.877-883
    • /
    • 1998
  • Background: Cardiopulmonary bypass(CPB), a standard adjunct for open heart surgery, can also play an important role in treating patients with noncardiac diseases. Material and Method: We report a collective analysis of noncardiac applications of cardiopulmonary bypass experienced at Seoul National University Hospital from 1969 to 1996. Out of a total of 20 patients, 8 were treated for membranous obstruction of inferior vena cava(MOVC), 5 for malignant melanoma, 3 for pulmonary embolism, 1 for double lung transplantation, 1 for intracranial giant aneurysm(GA), 1 for renal cell carcinoma(RC), and 1 for liposarcoma. CPB was used to induce profound hypothermia with circulatory arrest in 6 patients(MOVC 4, GA 1, RC 1). Result: CPB time was 113 mins on average for MOVC, 161 mins for GA, and 156 mins for RC, while the lowest rectal temperature was 26$^{\circ}C$ on average in MOVC, and 19$^{\circ}C$ in GA and RC. Postoperative recovery was good in all MOVC patients. The patient with GA, who underwent reoperation for the removal of hematoma, died 14 days postoperatively. The patient with RC recovered from the operation in a good condition but died from metastatic spread 6 months later. CPB was instituted for pulmonary embolectomy in 3 patients, in whom postoperative courses were uneventful, except in 1 patient who showed transient neurologic symptoms. CPB was used in a patient with double-lung transplantation for hemodynamic and ventilatory support. The patient was weaned successfully from CPB but died from low output and septicemia 19 days postoperatively. CPB without circulatory arrest was used to treat in 4 patients with MOVC. These patients showed good postoperative courses. CPB was used to administer high concentrations of chemotherapeutic agents to the extremities in 6 patients(malignant melanoma 5, recurrent liposarcoma 1). CPB time was 153 mins on average. No complications such as edema and neurologic disability were found. Conclusion: Although CPB has a limited indication in noncardiac diseases, if properly applied, it can be a very useful adjunct in a variety of surgical cases.

  • PDF

Study on the Recycled Compositing System for Reducing Bulking Agent Cost (부자재 비용절감을 위한 순환퇴비화 시스템에 관한 연구)

  • 최명환;홍지형;박금주;최원춘
    • Journal of Animal Environmental Science
    • /
    • v.6 no.3
    • /
    • pp.191-199
    • /
    • 2000
  • This study was initiated to investigate the influence of biophysical condition on the composting characteristics, and conducted to develop technology for using recycled compost as a bulking agent cost to reduce operating cost. To methods of aeration, continuous aeration (CA: run No. I) and intermittent aeration (IA: run No. 2) were performed with three 12.3 liter laboratory scale vessels for ten days. Manure and rice hulls were mixed for thirst trial (I), rice hulls and recycled compost after first trial were mixed for second trial (II), dairy manure and only recycled compost after second trial were mixed for third trial (III). During the composting process, temperatures of the compost mass and ammonia emissions were measured. The quality and maturity of compost were ascertained by examining the characteristics and composition of the compost. Also, loss of mass was determined by measuring the mass of materials in the vessels before and after composting. The results in this study are as follows: 1. The periods of optimum temperature ($>55^{\circ}C$) to kill pathogens were maintained from 38 to 78 hours for CA and from 60 to 98 hours for IA. 2. The more recycled compost mixed, the more ammonia emitted. The maximum ammonia emissions were 287 ppm at CA and 420 ppm at IA. 3. Biofiltration system was required for the compo sting system using only recycled compost as an amendment, because the ammonia emissions was produced above 100 ppm at the end of composting process. 4. The quality and maturity of compost: - Fresh compost, were required drying, because moisture contents of the compost were approximately 70% in all tests. - The pH values were observed to rise smoothly, from 7.9 to 8.3 at CA and from 8.4 to 8.6 at IA. The CfN ratios of the fresh compost were ranged form 21.05 to 16.42 for CA and from 22.81 to 14.75 for IA. The final C/N ratios for test II and III were below 20.were below 20.

  • PDF

A Study on Location Selection for Rainwater Circulation System Elements at a City Level - Focusing on the Application of the Environmental and Ecological Plan of a Development - (도시차원의 빗물순환체계 요소별 입지선정에 관한 연구 - 개발예정지역의 환경생태계획 적용방안을 중심으로 -)

  • Kim, Hyo-Min;Kim, Kwi-Gon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.3
    • /
    • pp.1-11
    • /
    • 2012
  • This study focused on establishing a natural rainwater circulation system using rainwater meant for relatively large urban development projects such as a new town development. In particular, when the location selection techniques for individual elements of a natural rainwater circulation system are developed for the integrated rainwater management, changes in hydrological environment will be minimized and the natural water circulation would be restored to realize the low impact development (LID). In that case, not only the excess will be reduced but water space and green areas in a city would also increase to improve the urban sustainability. First of all, there were five elements selected for the location selection of a rainwater circulation system intended for the integrated rainwater management: rainwater collection, infiltration, filtration, retention and movement spaces. After generating these items, the location selection items and criteria were defined for each of the five elements. For a technique to apply the generated evaluation items and criteria, a grid cell analysis was conducted based m the suitability index theory, and thematic maps were overlapped through suitability assessment of each element and graded based on the suitability index. The priority areas were identified for each element. The developed technique was applied to a site where Gim-cheon Innovation City development is planned to review its feasibility and limitations. The combined score of the overlapped map for each element was separated into five levels: very low, low, moderate, high and very high. Finally, it was concluded that creating a rainwater circulation system conceptual map m the current land use plan based on the outcome of the application would be useful in building a water circulation system at the de1ailed space planning stage after environmental and ecological planning. Furthermore, we use the results of this study as a means for environment-friendly urban planning for sustainable urban development.

(A study on the fuel economy in the vehicle using variable cylinder system) (가변실린더시스템을 이용한 차량의 연비향상에 관한 연구)

  • 이태표;김종부;박준훈
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.1
    • /
    • pp.71-76
    • /
    • 2002
  • Because the driving time is increased under the low speed by rapidly increasing of vehicles, this paper is presented a new ignition control system for improvement the fuel economy, which only some of cylinders are using under the idle status or low speed and preserving the engine rpm. is applicable to effective in fuel economy. An actual hardware was made to prove this new control system. The developed variable cylinder engine concentrated the heat neat the cylinders in idle status or low speed, so there was a problem in re-ignition. It was the reason of a lot of exhaust gas, high fuel consumption and instability of engine revolution. In this paper, in order to solve above problem to show the improvement fuel economy using the new ignition control system and valve opening period at idle status of low speed.

Model Development for the Surface Discharge of Heated Water using Turbulence Model (난류모델을 이용한 표면 온배수 확산모형의 개발)

  • 최흥식;이길성
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 1989.07a
    • /
    • pp.113-114
    • /
    • 1989
  • 원자력, 화력발전소, 제철소 등의 다양한 임해 공업시설로부터 방출되는 냉각용 온배수는 연안일대 해수의 열균형을 파괴시켜 생태계의 보존 및 환경관리에 좋지 못한 영향을 야기케 된다. 이러한 영향은 해안 또는 만내의 수중온도를 전반적으로 높일뿐 아니라 가동중단시 갑자기 수온을 떨어뜨려 해양생물상에 피해를 줄수도 있다. 또한 온배수에 의하여 온도가 상승된 해수가 취수구를 통하여 재순환되어 냉각기능의 부진을 초래하게되면 발전효율 또는 기계가동율을 저하시키게 된다. 이러한 측면에서 온배수의 확산에 대한 정성, 정량적인 예측은 환경영향평가, 취.배수구 설계조건의 산정 등에 매우 중요한 문제라 하겠다. 본 연구는 정지수역으로 유입하는 3차원 정상류 표면온배수 해석모형의 개발로서 개발된 모형의 수치실험을 통하여 온배수 확산의 물리적 특성을 규명한다. 지배방정식에 나타나는 Reynolds 응력항($)과 온도유동 프럭스항($)의 해석에서 필요한 난류모델은 k-$\varepsilon$ 모형에 난류 평균자승 온도유동($) 및 그 감쇄방정식을 추가한 4-방정식 모델로서 구성하였다. 아울러 3차원 정상류 모형에서 야기되는 타원형 방정식을 포물형 방정식의 형태로 전환하여 효과적으로 해석할 수 있도록 모델의 특성을 정리하였다. 본 모델의 검증을 위하여 Lal 및 Rajaratnam(1977)의 물리적 실험값과 비교해본 결과 온배수 거동의 물리적현상이 잘 일치하였다. 또한 McGuirk 및 Rodi(1979)에 의해 개발된 2-방정식 k-$\varepsilon$ 난류모형의 해석결과에 대하여 비교분석을 실시하였다.

  • PDF

The Development of the Data Error Inspection Algorithm for the Remote Sensing by Wireless Communication (원격계측을 위한 무선 통신 에러 검사 알고리즘 개발)

  • 김희식;김영일;설대연;남철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.993-997
    • /
    • 2004
  • A data error inspection algorithm for wireless digital data communication was developed. Original data converted By wireless digital data error inspection algorithm. Wireless digital data is high possibility to get distortion and lose by noise and barrier on wireless. If the data check damaged and lost at receiver, can't make it clear and can't judge whether this data is right or not. Therefore, by wireless transmission data need the data error inspection algorithm in order to decrease the data distortion and lose and to monitoring the transmission data as real time. This study consists of RF station for wireless transmission, Water Level Meter station for water level measurement and Error inspection algorithm for error check of transmission data. This study is also that investigation and search for error inspection algorithm in order to wireless digital data transmission in condition of the least data's damage and lose. Designed transmitter and receiver with one - chip micro process to protect to swell the volume of circuit. Had designed RF transmitter - receiver station simply by means of ATMEL one - chip micro processing the systems. Used 10mW of the best RF power and 448MHz-449MHz on frequency band which is open to public touse free within the limited power.

  • PDF

Ruptured Penetrating Atherosclerotic Ulcer of the Aortic Arch in a Patient with a Previous History of Replacing the Descending Thoracic Aorta (하행대동맥 수술의 기왕력을 가진 환자에서 발생한 대동맥궁 침투성 궤양의 파열)

  • Kim, Jae-Bum;Choi, Sae-Young;Park, Nam-Hee
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.647-650
    • /
    • 2008
  • Aortic disease usually recurs after aortic surgery in the form a new aneurysm distal to the previous operation site, and finding a penetrating atherosclerotic ulcer proximal to the previous operation site has rarely been reported. We report here on a case of successful patch repair of a ruptured penetrating ulcer in the distal aortic arch, and this developed late after replacement of the descending thoracic aorta.

One-stage Replacement of the Total Thoracic Aorta (전 흉부 대동맥 동시 치환술 -1례 보고-)

  • 김관민;김성철;박표원
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.595-598
    • /
    • 1999
  • Some extensive thoracic aortic aneurysms are not amenable to staged repair, such as extremely large distal aortic aneurysms that are unsuitable for an elephant trunk anastomosis, or aneurysms that are accompanied by complications such as ruptured descending thoracic aneurysm. We report here a case of successful replacement of the aorta from the ascending to the descending aorta in one operation. The patient was 65-year-old man who had an aneurysm which involved the entire thoracic aorta and ruptured in the descending aorta. The operation was performed via transverse thoracosternotomy, and under the deep hypothermic circulatory arrest with retrograde cerebral perfusion. The patient recovered uneventfully and was discharged without any neurologic complications.

  • PDF