• Title/Summary/Keyword: 순환여과식 양식장

Search Result 20, Processing Time 0.035 seconds

Implementation of an Automated In-line Water Quality Measurement System of Recirculation Fish Farm with IoT (IoT에 의한 순환여과식 양식장 자동 수질 측정 시스템 구현)

  • Kim, Sun-Woo;Choi, Yeon-Sung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.3
    • /
    • pp.477-484
    • /
    • 2017
  • In the conventional recirculation fish farms, there is a lot of difficulties due to lack of professional manpower and high reliance on imported measurement equipment. In this paper, we implement an automatic water quality measurement system which can measure the pollution degree in a water tank of fish farms using an optical sensor(pH, DO) with the IoT technology. The problem with existing systems is that the fish tank should be checked by means of human, or put the measuring equipment into the water tank of fish farms and measurement directly. But, it has a bad influence on the growth of fish. In this paper, we propose a method of indirect measurement without immersing the measurement equipment in a water tank of fish farm and develop a sustainable measurement system in an environment containing salt and lots of pollutants without affecting the growth of fish within the water tank of fish farms.

A study on machine learning-based anomaly detection algorithm using current data of fish-farm pump motor (양식장 펌프 모터 전류 데이터를 이용한 머신러닝 기반 이상 감지 알고리즘에 관한 연구)

  • Sae-yong Park;Tae Uk chang;Taeho Im
    • Journal of Internet Computing and Services
    • /
    • v.24 no.2
    • /
    • pp.37-45
    • /
    • 2023
  • In line with the 4th Industrial Revolution, facility maintenance technologies for building smart factories are receiving attention and are being advanced. In addition, technology is being applied to smart farms and smart fisheries following smart factories. Among them, in the case of a recirculating aquaculture system, there is a motor pump that circulates water for a stable quality environment in the tank. Motor pump maintenance activities for recirculating aquaculture system are carried out based on preventive maintenance and data obtained from vibration sensor. Preventive maintenance cannot cope with abnormalities that occur before prior planning, and vibration sensors are affected by the external environment. This paper proposes an anomaly detection algorithm that utilizes ADTK, a Python open source, for motor pump anomaly detection based on data collected through current sensors that are less affected by the external environment than noise, temperature and vibration sensors.

Water Quality Control in the Semiclosed Culture System Growing a Flounder, Paralichthys Olivaceus (반폐쇄 순환여과식 넙치양식장의 수질제어에 관한 연구)

  • YANG Byung-Soo;LEE Heon-Mo;JEONG Byung-Gon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.25 no.3
    • /
    • pp.197-204
    • /
    • 1992
  • A comparative evaluation of water quality in the existing semiclosed fish culture system was made to improve the system management. From the comparison of water quality between the flow-through mode and the recycle mode of the semiclosed system, the malfunctioning of the settling channel deteriorated water quality and reduce the nitrification rate in the recycle mode. The peak concentrations of COD, $PO_4-P$ and SS in the fish tanks appeared just after feeding, and then decreased to normal levels within two hours. However, the $NH_4-N$ concentration increased slightly after two hours of feeding in the recycle mode. The water exchange rate was directly related to the water quality in the semiclosed fish culture system.

  • PDF

IBK 순환여과식 시설 내 펌프장에서의 baffle 깊이에 따른 산소전달 효과

  • 조재윤;김인배;박정환;이진환;서근학
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2000.05a
    • /
    • pp.239-240
    • /
    • 2000
  • 용존산소는 양식 시설 내 생산량을 결정짓는 중요한 수질 조건으로서, 시설 내 용존산소를 충분히 공급하기 위해 많은 연구자들이 여러 가지 형태의 에어레이터의 고안(Boyd and Tucker, 1979)및 순수산소의 이용에 관해 연구해왔다. 그러나 에어레이터 또는 순수 산소의 이용은 추가 에너지가 필요한데, 송어 양식장에는 전체비용의 13∼15%, 부화장의 경우에는 23%(Petit, 1990) 및 순환여과식 시설에서는 8.6%(Timmons and Aho, 1998)의 경비가 추가된다고 한다. (중략)

  • PDF

유연성 섬유사 필터 모듈을 이용한 육상수조식 양식장 수처리

  • 최광수;한기백;이해군;김지원
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.05a
    • /
    • pp.81-82
    • /
    • 2003
  • 육상수조식 양식장 수처리를 위한 순환여과 시스템으로서의 유연성 섬유사 필터 모듈의 적용성을 평가하기 위하여, 여과기의 운전주기에 따른 처리성능의 변화 추이 및 넙치사육조의 급이주기에 따른 여과성능의 변화를 검토한 결과, 유기물 농도의 경우 20~70%의 제거육을 보였으며, 탁도는 평균 50% 이상의 제거율을 보여주었다.

  • PDF

CTA gel을 세포 포획용 matrix로 이용한 고밀도 순환여과식 양식장 순환수 처리

  • 정병곤;김문태;김광균
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2002.10a
    • /
    • pp.154-155
    • /
    • 2002
  • 미생물 능동 포획기술은 원하는 미생물을 Gel matrix내에 포획시켜 수중의 오염물질을 제거하는 방법이다. 미생물을 포획시키기 위한 Gel 물질로는 종래에는 alginate나 carrageenan 같은 천연고분자 물질이 사용되어져 왔으나 최근 들어 PVA나 PEG와 같은 합성고분자 물질을 사용하는 방법이 많이 시도되고 있다. (중략)

  • PDF

Optimum Conditions for the Removal of External Organic Carbon Sources in a Submerged Denitrification Biofilter (탈질 여과조에서 외부 탄소원 제거를 위한 적정 체류 시간과 외부 탄소원 종류 및 질산염 농도에 대한 외부 탄소원의 적정 비율)

  • 오승용;조재윤;윤길하
    • Journal of Aquaculture
    • /
    • v.12 no.1
    • /
    • pp.47-56
    • /
    • 1999
  • Denitrification by anaerobic bacteria is one of the most common processes of removing nitrate from recirculating aquaculture systems. This process is affected by many factors such as external carbon sources, hydraulic retention time (HRT), and $COD/NO_3-N$ ratio. Although external organic carbon sources are essential for the denitrification process, these also contribute to increase dissolved organic carbon concentration in recirculating aquaculture systems. So these external organic carbons must be removed from the systems. This study was conducted to find out the optimum operating conditions for the removal of external organic carbons in a submerged denitrification biofilter. Combinations of two external carbon sources (glucose and methanol), two HRT (4- and 8-hour), and four different C:N ratios (3, 4, 5, and 6) were used in this experiment. The removal efficiencies of organic carbon sources at 8-hour HRT were always better than those at 4-hour's (P<0.05). Maximum removal efficiencies were achieved when C:N ratio was 5 in both glucose and methanol. The removal efficiencies of methanol were always better than those of glucose. The maximum removal efficiencies of glucose and methanol were 76.5% and 84.0%, respectively and the removal rates were 223.5 $g/m^2/day$ and 247.1$g/m^2/day$. The maximum removal rates of glucose (290.9 $g/m^2/day$) and methanol (355.6 $g/m^2/day$) were achieved at 4-hour HRT and 5 C:N ratio. But the concentrations of SCOD in the effluent of both glucose ($52.5 mg/\ell$) and methanol ($40.9 mg/\ell$) were too high for rearing fish. Therefore, the optimum operating conditions for the removal of external carbon in a submerged denitrification biofilter were 8-hour HRT and 5 C:N ratio. And methanol showed better efficiency as an external carbon sources.

  • PDF

Feasibility Study of Applying EMMC Process to Recirculation Water Treatment System in High Density Seawater Aquaculture Farm through Laboratory Scale Reactor Operation (실험실규모 반응조 운전을 통한 고밀도 해산어 양식장 순환수 처리공정으로서 EMMC공정의 적용 가능성 연구)

  • Jeong Byung Gon;Kim Byung Hyo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.7 no.3
    • /
    • pp.116-121
    • /
    • 2004
  • Treatability tests were conducted to study the feasibility of EMMC process as a recycling-water treatment system in high density seawater aquaculture farm. To study the effect of organic and ammonia nitrogen loading rate on system performance, hydraulic retention time was reduced gradually from 12hr to 10min. The conclusions are can be summarized as follows. When the system HRT was reduced from 12hr to 2hr gradually, there was little noticeable change(reduction) in ammonia nitrogen removal efficiencies. However, removal efficiencies were decreased dramatically when the system was operated under the HRT of less than 2hr. In case of organics(COD), there was no dramatic change in removal efficiencies depending on HRT reduction. COD removal efficiencies were maintained successfully higher than 9% when the system was operated at tile HRT of 10 min. System performances depending on media packing ratio in the reactors were also evaluated. There were little differences in each reactor performances depending on media packing ratio in reactor when the reactors were operated under the HRT of longer than 1hr. However, differences in reactor performances were considerably evident when the reactors were operated under the HRT of shorter than 1hr. When comparing reactor performance among 25%, 50%,7 5% packed reactor, it can be judged that media packing ratio more than 50% plays no significant role in increasing reactor performance. For this reason, packing the media less than 50% is more reasonable way in view of economic. Such a tendency shown in COD removal efficiencies well agreed with the variation of ammonia-nitrogen removal efficiencies according to the media packing ratio in reactors at each HRT. Difference in effluent ammonia-nitrogen concentration between 50% media packing reactor and 75% media packing reactor was negligible. When comparing with the results of 25% packing reactor, difference was not so great.

  • PDF

Removal of Suspended Solids Using a Flexible Fiber Filter in a Recirculating Aquaculture System (유연성 섬유사 여과기를 이용한 순환여과식 양식장의 부유고형물 제거)

  • Choi, Kwang-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.40 no.2
    • /
    • pp.73-78
    • /
    • 2007
  • The suitability of a flexible fiber filter for removing suspended solid (SS) in a recirculating aquaculture system was evaluated. This study focused on variation in the performance with a change in filtering time, influent water quality, and filtering mode duration. The particle distribution diagram of the filter effluent showed that the number of particles bigger than $5-8{\mu}m$ decreased dramatically, and the removal efficiency exceeded 80%. Although the removal efficiencies of SS and chemical oxygen demand (COD) were dependent on the quality of the influent, the SS and COD concentrations of the effluent were not affected by the influent concentrations. This was despite the deterioration if water quality after feeding in the rearing tank. The performance of the filter was not affected by the filtering mode duration, feeding conditions, or filtering time. The SS concentration and turbidity of the recirculating-type rearing tank were 30% and 50% lower, respectively, than of the a non-recirculating-type rearing tank under the same operating conditions. The flexible fiber filter was applicable to a recirculating aquaculture system that uses plenty of seawater, based on its low filtering resistance $(2kg_f/cm^2)$, high flux $(330m^3/m^2/hr)$, and high fine particle removal efficiency (80%, $5-8{\mu}m$).

Removal of Suspended Solids and Nitrification by Floating Bead Filter in Recirculating Aquaculture System (Floating Bead Filter에 의한 순환여과식 양식장의 부유고형물 제거와 질산화)

  • KIM Byong Jin;KIM Sung Koo;SUH Kuen Hack
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.2
    • /
    • pp.163-169
    • /
    • 2003
  • The floating bead filter was tested for treatment of aquacultural water in a pilot-scale recirculating aquaculture system. Performance of floating bead filter on the removal of total suspended solids (TSS) and the treatment of nitrogen sourer such as total ammonia nitrogen (TAN), nitrite nitrogen and nitrate nitrogen were evaluated. The system was stocked with Nile tilapia at an initial rearing densities of $5\%\;and\;7\%$ over 30 days. The average TSS removal rates were $43.0\;g/m^2{\cdot}day\;and\;39.5\;g/m^2{\cdot}day$ for rearing density of $5\%\;and\;7\%$, respectively. As rearing density increased from $5\%\;to\;7\%$. the TAN removal efficiency decreased from $22.0\%\;to\;17.7\%$. At the rearing densities of $5\%\;and\;7\%$, the average TAN removal rates and removal efficiencies were $38.8\;g/m^2{\cdot}day,\;15.6\%\;and\;37.8\;g/m^2{\cdot}day.\;17.7\%,$ respectively. The average TAN removal rate was $37.8-38.8\;g/m^3{\cdot}day.$ The oxygen consumption by floating bead filter was higher than theoretical oxygen consumption rate by nitrification.