• Title/Summary/Keyword: 순환동력

Search Result 115, Processing Time 0.026 seconds

A Study on Application of Mono-Ether Group(Ethylene Glycol Mono-n-Butyl Ether) Oxygenated Fuel in an IDI Diesel Engine (간접분사식 디젤기관에서 Mono-Ether 계열 함산소연료(Ethylene Glycol Mono-n-Butyl Ether)의 적용에 관한 연구)

  • Choi, S.H.;Oh, Y.T.
    • Journal of Power System Engineering
    • /
    • v.9 no.3
    • /
    • pp.15-20
    • /
    • 2005
  • In this paper, the effect of oxygen component in fuel on the exhaust emissions has been investigated for an indirect injection diesel engine. It was tested to estimate change of engine performance and exhaust emission characteristics for the commercial diesel fuel and oxygenated blended fuel which has four kinds of mixed ratio. And, the effects of exhaust gas recirculation(EGR) on the characteristics of NOx emission have been investigated. Ethylene glycol mono-n-butyl ether(EGBE) contains oxygen component 27% in itself, and it is a kind of effective oxygenated fuel of mono-ether group that the smoke emission of EGBE is reduced remarkably compared with commercial diesel fuel, that is, it can supply oxygen component sufficiently at higher loads and speeds in diesel engine. It was found that simultaneous reduction of smoke and NOx was achieved with oxygenated fuel(10vol-%) and cooled EGR method(10%).

  • PDF

A study on flow characteristic of a stand type Kimchi refrigerator for optimum design of air flow passage (서랍식 김치냉장고의 최적 유로 설계를 위한 유동특성에 관한 연구)

  • Han, H.R.;Jung, H.Y.;Park, Y.K.;Choi, Y.H.;Lee, Y.W.
    • Journal of Power System Engineering
    • /
    • v.15 no.5
    • /
    • pp.37-42
    • /
    • 2011
  • The normal cooling system of a refrigerator is applied to indirect a cooling methods. But the Kimchi refrigerator is applied to direct the cooling method. Recently when the model was applied to both direct and indirect the cooling methods, the improvement was considerable. With the development of the living standards in Korea, there has been more sensitive dissatisfaction about the taste and the smell of Kimchi. In order to solve these kinds, there is a need to systematic and scientific approach. Based on these, the purpose of this study is to optimize design for improve the storage period of Kimchi refrigerator. In this research, we concentrate on the temperature change and heat transfer characteristics of interior parts of the Kimchi refrigerator due to control cycle of temperature and flow phenomenon of cooling air.

Design of Multivariable 2-DOF PID for Electrical Power of Flow System by Neural Network Tuning Method (신경망 튜우닝에 의한 유량계통 동력 제어용 다변수 2-자유도 PID의 제어기 설계)

  • 김동화
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.78-84
    • /
    • 1998
  • The fluid system such as, the quantity control of raw water, chemicals control in the purification, the waste water system as well as in the feed water or circulation system of the power plant and the ventilation system is controlled with the valve and moter pump. The system's performance and the energy saving of the fluid systems depend on control of method and delicacy. Until, PI controller use in these system but it cannot control delicately because of the coupling in the system loop. In this paper we configure a single flow system to the multi variable system and suggest the application of 2-DOF PID controller and the tuning methods by the neural network to the electrical power of the flow control system. the 2-DOF controller follows to a setpoint has a robustness against the disturbance in the results of simulation. Keywords Title, Intelligent control, Neuro control, Flow control, 2 - DOF control., 2 - DOF control.

  • PDF

Numerical Analysis on Changes in Flowrate of Draft Water and Power by Changing Design Parameters of a Long-Distance Water Circulation (저층수 흡입식 광역 순환장치의 설계변수에 따른 배출량 및 소비동력 변화 특성에 대한 수치 해석 연구)

  • Song, Dong-Keun;Hong, Won-Seok;Kim, Young-Cheol;Park, Myong-Ha
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.1
    • /
    • pp.23-28
    • /
    • 2010
  • A draft tube which has impeller to elevate bottom water and spread it over surface of lake water, induces convective circulation of lake water, a Long-Distance Circulation (LDC). Circulation of lake water make stratified water mixed and enhance DO (Dissolved Oxygen) of bottom water. Circulation rate of water is determined by draft rate of the tube, which is dependent on design parameters of the draft tube system, i. e. dimension of impeller and diffuser, inclined angle of impeller, impeller shape, and rotational speed. In this study, change in draft rate and power consumption of circulation equipment was investigated numerically with changing impeller dimension, angle and rotational speed. It was found that flowrate of draft water was increased as the dimensions of draft tube and impeller, and rotational speed and inclined angle of impeller increased. The power consumption was also elevated with increasing parameter values, and final selection of parameter values was made to satisfy target flowrates and power consumption.

A Field Application Case of Direct Ice Slurry Transporting System for District Cooling (지역냉방용 직접순환식 아이스슬러리 시스템의 현장적용 사례)

  • Yoo, Ho-Seon;Lee, Sang-Hoon;Lee, Yoon-Pyo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.9
    • /
    • pp.496-504
    • /
    • 2009
  • In order to investigate the feasibility of a direct ice slurry transporting system for the purpose of district cooling, a case study of field application is performed. The research aims include the field measurement of ice packing factor, the performance of coldness delivery, and the branching characteristics of ice slurry. Two representative types of pipe branch are dealt with in this work. For the slurry flow with ice volume fraction of 0.16 or less, the pipe blocking due to aggregation is not observed. Based on the time-wise variation of temperature in the storage tank, a calculating method of ice packing factor is newly developed, which seems to be useful when the brine concentration is unknown. It is confirmed that the mass flow rate of ice slurry per unit cooling load is markedly reduced with increasing the ice content. The pumping power also decreases, but remains unchanged for high ice fractions. The distribution of ice particle before and after branching shows a good uniformity within the range of 5% difference, but yields a unique trend depending on the flow rate.

Cooling Performance on the Small Diesel Engine (소형(小型)디젤기관(機關)의 냉각성능(冷却性能)에 관(關)한 연구(硏究))

  • Kim, Sung Rai;Myung, Byung Soo
    • Korean Journal of Agricultural Science
    • /
    • v.17 no.1
    • /
    • pp.45-51
    • /
    • 1990
  • This study was conducted to obtain basic data for the design of cooling system by the test of engine performance of the power tiller being used widely in the rural area. Among the various factors affecting engine performance, the flow rate of cooling water was considered as the major factor in this study. Motoring loss, output, fuel consumption ratio, torque, heat absorption of cooling water, and thermal efficiency were measured and analyzed based on three flow rates of cooling water such as 15, 20, and $25{\ell}/min$. The results obtained were as follows : 1. Motoring loss of the engine was 1.371 kW at 2,200 rpm., and mechanical efficiency was 79.1% at rated output level. 2. Output power of the engine increased with the flow rate of cooling water increased. 3. BSFC was 282.9g/kW-h at the flow rate of $20{\ell}/min$, and the temperature of cooling water at outlet was $80.9^{\circ}C$. 4. There was a little variation of torque of the engine depending on the flow rate of cooling water. 5. Absorption of heat by cooling water was increased with the increase of flow rate. 6. The highest thermal efficiency of 32.3% at the flow rate of $20{\ell}/min$ was observed.

  • PDF

Income-led Growth and Legacy of the Korean Welfare Regime (소득주도성장과 한국 복지체제의 유산 : 분배와 성장의 선순환을 만들 수 있을까?)

  • Yoon, Hong-Sik
    • 한국사회정책
    • /
    • v.25 no.2
    • /
    • pp.243-280
    • /
    • 2018
  • This paper examines the discussion on the income-led growth known as the core economic strategy of Moon's administration in terms of Korean welfare regime. Although the income-led growth strategies have presented various issues, the income-led growth strategy seems to be a timely alternative discourse that emphasizes the demand side, considering supply-oriented growth strategies have caused long-term recession and deepening of inequality. It is important that the income-led growth strategy places social expenditures as an important growth engine for virtuous cycle of production and consumption. However, this paper has confirmed that simply raising wages and increasing social expenditure do not increase the aggregate demand and production. Moreover, empirical studies have shown that the inclusion of external sectors and liabilities into the analysis weakens the wage-led growth of the Korean economy. For this reason, this study concluded that the government's sophisticated policy intervention is necessary for the increase of real wages and social spending to be economic growth.

Working principle & application of comprex pressure wave super charger (Comprex 압력파 과급기의 작동 및 응용)

  • Gyarmathy, George
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.7 no.4
    • /
    • pp.24-31
    • /
    • 1985
  • 본 논문은 Comprex압력파 과급기(Pressure-wave Supercharger;이하 PWS)의 공기 역학적인 원 리에 대해 기술하였으며, 또 기체 동력학적인 현상들이 별도의 제어장치없이도 우수한 운전성과 낮은 연료소모율, 적은 배기 배출물을 형성하는 차량들에 대해 기계적으로는 간단하면서도 완벽 한 boosting장치를 만들어 내는데 어떻게 사용될 수 있는지를 설명하였다. 근본적인 목적은 종 래의 turbo charger와 동일이지만 Comprex PWS는 현재 응용되고 있는 승용차가 요구하는 여러 가지면, 즉 1) 부하변동에 대한 충진공기압의 빠른 응답성 2) 엔진속도 전영역에 걸친 높은 boost 효과 3) 배기배출물특성을 좋게할 수 있는 배기가스 재순환(EGR)효과 등에서 종래의 것과 구별된다. 따라서 PWS의 중요한 특징들을 기술하였으며 마지막으로 최근 자동차용 Diesel Engine에의 몇 가지 예를 보았다.

  • PDF

Modeling and Analysis of Soil Moisture Dynamics in the Large River Basin (넓은 유역에 있어서의 토양 수분 동력학의 모델링과 분석)

  • 이재수
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 1994.02a
    • /
    • pp.449-456
    • /
    • 1994
  • 넓은 지역(Arkansas River Basin)에 대하여 토양 수분을 기본으로한 물 수지 모델이 계절별 년별 시간단위로 연구되었다. 지표면과 대기 수분사이의 상호 작용과 재순환 효과에 대한 연구가 유역의 매개 변수화 과정에서 수행되었으며 대규모의 지표면과 대기사이의 상호 작용에 의하여 넓은 지역의 지표 수문은 장기간의 확률분포함수에 있어서 두가지 즉 건조와 습한 안정상태의 영향을 받는다. 토양수분 균형 방정식에서 추계학적 변동은 주위환경 변동에 의하여 야기되는 안정상태 사이의 변이와 함께 분리된 선호하는 통계학적 안정상태를 초래한다. 과거의 자료를 바탕으로 비선형 물수지 모델이 Arkansas강 유역에 대하여 검정되었다. 모델에서 안정상태 사이의 평균 변이시간이 물리과정의 추계학적 표현과 검정된 모델변수들로부터 계산되었다. 본 연구는 안정상태 사이의 변이시간 혹은 거주시간, 즉 시스템이 주어진 안정상태에 머무는 시간(가뭄이나 홍수상태의 지속기간)의 예측과 밀접한 관계가 있다.

  • PDF

Heating Performance of Ground source Heat Pump using Extruding Ground Water (유출지하수 열원 지열히트펌프시스템의 난방성능)

  • Park, Geun-Woo;Lee, Eung-Youl
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.460-465
    • /
    • 2007
  • 유출지하수는 지하공간이 깊고 넓게 분포하는 건물에서 자연적으로 유출되어 배출되는 낮은 심도의 지하수이다. 본 연구에서는 신축된 교회건물에서 유출되는 지하수를 열원으로 밀폐형태와 개방형태의 열교환기를 활용하여 각각 5RT급 히트펌프시스템을 난방모드로 운전한 결과를 정리하였다. 실험은 난방순환수의 온도를 $43{\sim}49$ $^{\cdot}C$ 범위에서 제어하면서 진행하였으며, 시스템 COP에 있어서 밀폐형은 $4.12{\sim}4.75$, 개방형은 $3.42{\sim}3.98$의 범위에서 측정되었다. 이는 기존의 지열히트펌프시스템의 COP와 대동 소이한 우수한 성능이라고 판단된다. 또한 펌프동력을 제외한 히트펌프 자체 난방COP에 있어서 밀폐형은 $4.69{\sim}5.81$, 개방형은 $4.38{\sim}5.43$의 범위에서 나타났다. 유출지하수의 온도가 겨울철에도 약 $12{\sim}14^{\cdot}C$를 유지하므로 히트펌프와 시스템전체의 COP가 매우 우수한 값을 나타내고 있음이 확인되었다.

  • PDF