• Title/Summary/Keyword: 순음도

Search Result 111, Processing Time 0.03 seconds

Development of PureTone Generator with STL (신호 시제 논리를 사용한 순음 생성기 개발)

  • Kwon, Hyuck;Kwon, Gihwon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.1082-1084
    • /
    • 2015
  • 본 논문에서는 신호 시제 논리를 이용하여 순음 생성 시스템을 개발한다. 일반적으로 많이 알려지고 널리 쓰이는 시제 논리는 선형 시제 논리이다. 그러나, 선형 시제 논리로는 다양한 실수 값과 정량적인 시간을 다루지 못하는 문제점이 있다. 그러므로, 본 논문에서는 신호 시제 논리를 이용하여 이러한 문제점을 극복하고, 선형 시제 논리로는 어려웠던 순음 발생기를 신호 시제 논리를 사용하여 개발한다.

The Correlation Between Speech Reception Threshold and Pure Tone Audiometry (어음청취역치와 순음청력검사의 상관관계에 관한 연구)

  • 이철희;선우대활;민양기;백만기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.38.2-39
    • /
    • 1981
  • Speech reception threshold is a base for word discrimination testing, but it also serves as a check for the reliability of pure tone audiogram. In order to investigate the correlation between SRT and PTA these tests were carried out in patients with conductive hearing loss and normal hearing, using Grason-Stadler 1702 Audiometer. The results were as follows; 1) The difference between the scores of SRT and PTA's was 2.4 dB with a range of -3.3 dB∼+8.3 dB in conductive hearing loss, and was 1.9 dB with a range of -6.7 dB∼+5 dB in normal hearing group. 2) The difference between the scores of SRT and each speech frequency of PTA was 6 dB at 500 Hz, 3 dB at 1,000 Hz and 8.8 dB at 2,000 Hz in conductive hearing loss, and 3 dB at 500Hz, 2 dB at 1,000Hz, and 5dB at 2,000Hz in normal hearing group.

  • PDF

Development of Automatic Calibration System for PC-Based Pure Tone Audiometer (PC 기반 순음청력검사기를 위한 자동보정시스템 개발)

  • Kim, Jin-Dong;Kang, Deok-Hun;Song, Bok-Deuk;Lee, Il-Woo;Kong, Soo-Keun;Kwon, Soon-Bok;Jeon, Gye-Rok;Shin, Bum-Joo;Wang, Soo-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2586-2594
    • /
    • 2010
  • A pure tone audiometer should be able to produce both pure tone and masking noise with exact sound pressure level and frequency. For such purpose, it is unavoidable to periodically calibrates pure tone audiometer. However, manual acoustic calibration requires not only attention but also long time. It is possible to execute automatically calibration using software if it is PC-based pure tone audiometer. In this paper, we describe auto-calibration software for PC-based pure tone audiometer and dedicated sound level meter which has been implemented upon PC by us. To verify auto-calibration module, we examine whether output of PC-based audiometer calibrated through auto-calibration of this paper satisfies RETSPL of IEC or not.

A Comparison of Pure-Tone Thresholds to the Pre and Post Fogging after Refractive Correction in Normal Eyes (굴절교정된 정상안에서 운무 전후에 따른 순음청력역치의 비교)

  • Cho, Soo-Jin;Joo, Seok-Hee;Lee, Koon-Ja;Choi, In-Sil;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.89-93
    • /
    • 2009
  • Purpose: To purpose of this study was the pure-tone audimetry changes to compare pre and post fogging after visual correction in normally hearing adults. Methods: The estimated that no ocular and audiolar disesases, we selected (male: 30, female: 20) in corrected visual acuity over the 1.0 eye. Pre and post fogging were measured using the pure-tone audimetry. Results: To compared fre and post fogging, fre fogging was higher than fre fogging. The take value were just about every kind of Hz but 200 Hz, respectively which were statistically significant (p<.05). Low Hz area in 250 and 500 Hz were 6.8${\pm}$8.4dBHL, 4.3${\pm}$6.6dBHL, there is not all the difference between any other area, 2000 Hz in the middle Hz area was 0.8${\pm}$4.5dBHL. Conclusions: The study presents different results of measurements in within normal limits. we thought that pure-tone thresholds to the pre and post fogging after refractive correction in normal adults and would be used basic data.

  • PDF

Tonality Design for Sound Quality Evaluation for Gear Whine Sound (승합차량의 액슬기어 음질의 평가를 위한 새로운 순음도 모델 개발과 응용)

  • Kim, Eui-Youl;Jang, Ji-Uk;Lee, Sang-Kwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.12
    • /
    • pp.1172-1183
    • /
    • 2012
  • Aure's tonality was considered as the sound metrics for the expression of the tonality of gear whine sound in a previous research. It was failed to use the Aure's tonality as a sound metric for the tonal impression. Thus Aures's tonality, was developed for tonal impression in previous research. However, this metric did not express well the tonality of gear whine sound since the whine sound is a non-stationary signal with frequency modulation and amplitude modulation. In this study, the new method for the tonality evaluation for a non-stationary signal is presented. It is developed based on the prominence ratio, tonality impression function, and lower threshold level. It improves the accuracy and reliability of the sound quality index being used for the sound quality evaluation of the axle-gear whine sound.

A Response of the Shoal of Chub Mackerel ( Scomber Japonics , HOVTTYUN ) to Underwater Sound (수중음에 대한 고등어 어군의 반응)

  • 서두옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.25 no.1
    • /
    • pp.12-17
    • /
    • 1989
  • A field experiment was carried out of confirm the effect of underwater sound on the luring of fish school of chub mackerel in the coast of Idousyo Island. Underwater sound that was made use of luring of fish school was pure sound and interval pure sound which the frequencies of the sound were 150Hz and 200Hz, respectively. The results of the observation of hooking and recording paper of fish finder indicate that the effect of emitting sound at 20m in the depth of water was remarkable for the luring of fish school of chub mackerel. The vertical pure sound pressure level at 150Hz and 200Hz of the water layer that was lured the fish school of chub mackerel were 140.1dB and 146.dB at 30m, 121.0dB and 126.6dB at 70m and 141.9dB and 120.5dB at 120m in the depth of water, respectively.

  • PDF

Auditory Thresholds of Black Rock Fish (조피볼락의 청각문턱치)

  • Park, Yong-Seok;Lee, Chang-Heon;Moon, Jong-Wook;Ahn, Jang-Young;Seo, Du-Ok
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.11 no.1
    • /
    • pp.88-97
    • /
    • 1999
  • Auditory thresholds were determined by means of a conditioned response to sound stimuli at frequencies 80, 100, 200, 300, 500 and 800 Hz for a 10 black rock fish, Sebastes schlegeli. The conditioned response was a change of a cardiac rhythm. It was established through an electric shock as unconditioned stimulus, and could be monitored on an oscilloscope. A stable acoustic condition was obtained by suspending the fish in a small cage at fixed position in the test tank. The sensitive frequencies ranged from 80 Hz to about 800 Hz, showing the best frequency around 100 Hz where the mean threshold value was 90.5 dB. A gradual rise below 300 Hz and a relatively sharp turn above 500 Hz were indicated in the audiogram. The method presented here seemed to be useful for a rapid determination of the audiogram of fishes.

  • PDF

Active Tonal Noise Control to Reduce the Low Frequency Tonal Sound (저주파 순음소음저감을 위한 능동 순음 소음제어)

  • 나희승;박영진
    • Journal of KSNVE
    • /
    • v.8 no.6
    • /
    • pp.1037-1042
    • /
    • 1998
  • This paper discusses the dependence of the convergence rate on the acoustic error path in these popular algorithms and introduces new algorithms which increase the convergence region regardless of the time-delay in the acoustic error path. We also Propose a novel control algorithm (AFC/CAFC) for tonal noise cancellation. The proposed algorithm estimates the magnitude and phase of the tonal noise. The algorithm uses the steepest descent method for the phase/magnitude estimation. Performances of tile CAFC algorithm are presented in comparison with those by the AFC algorithm based on computer simulations and experiments.

  • PDF

The Study for Noisy Speech Improvement with Noise Perception Pattern Suppression (잡음 신호의 지각 패턴 제어를 통한 음질 개선 알고리즘 개발에 관한 연구)

  • Kim Hunjoong;Cha Hyungtai
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.199-202
    • /
    • 2002
  • 본 논문에서는 사람의 청각 모델을 기반으로 잡음에 의해 손상된 음성 신호로부터 잡음 신호의 마스킹 특성과 신호에너지의 지각(知覺)을 나타내는 임계대역(critical band)에서의 잡음 에너지에 대한 지각 패턴인 noise excitation pattern을 이용한 잡음 에너지 차감과 잡음 추정 오차에 의한 변형된 음성신호 내의 순음(tonal) 성분과 비순음(non-tonal)성분의 보정을 통해 효과적인 음성 품질의 개선을 위한 연구를 하였다.

  • PDF