• Title/Summary/Keyword: 순시

Search Result 514, Processing Time 0.023 seconds

BER Performance Analysis for Adaptive Cooperation Scheme with Decode-and-Forward Relay-Selection (복호 후 전달 릴레이 선택을 이용한 적응형 협력 기법의 BER 성능분석)

  • Vu, Ha Nguyen;Kong, Hyung-Yun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.11A
    • /
    • pp.831-843
    • /
    • 2009
  • In this paper, we propose a new adaptive cooperation scheme with multi-relay nodes which achieves higher performance and spectral efficiency than that of some conventional cooperative schemes. The relay-selection is applied to choose the most potential relay among K ones. Afterward, the instantaneous signal-to-noise ratio (SNR) differences between S-D, S-R and R-D channels are considered for adaptive selection between the direct and the cooperation transmission strategy. In the proposed adaptive protocol, if the direct link is of high quality, the source will transmit to destination directly with all power consumption. Otherwise, the source broadcasts the signal with a lower power and requires the help of the chosen relay if it decodes correctly, else the source will transmit again with remaining power. Firstly, the spectral efficiency is derived by calculating the probability of each mode. Subsequently, the BER performance for the adaptive cooperation scheme is analyzed by considering each event that one of K relays is selected and then making the summation of all. Finally, the numerical results are presented to confirm the performance enhancement offered by the proposed schemes.

Adaptive K-best Sphere Decoding Algorithm Using the Characteristics of Path Metric (Path Metric의 특성을 이용한 적응형 K-best Sphere Decoding 기법)

  • Kim, Bong-Seok;Choi, Kwon-Hue
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.11A
    • /
    • pp.862-869
    • /
    • 2009
  • We propose a new adaptive K-best Sphere Decoding (SD) algorithm for Multiple Input Multiple Output (MIMO) systems where the number of survivor paths, K is changed based on the characteristics of path metrics which contain the instantaneous channel condition. In order to overcome a major drawback of Maximum Likelihood Detection (MLD) which exponentially increases the computational complexity with the number of transmit antennas, the conventional adaptive K-best SD algorithms which achieve near to MLD performance have been proposed. However, they still have redundant computation complexity since they only employ the channel fading gain as a channel condition indicator without instantaneous Signal to Noise Ratio (SNR) information. hi order to complement this drawback, the proposed algorithm use the characteristics of path metrics as a simple channel indicator. It is found that the ratio of the minimum path metric to the other path metrics reflects SNR information as well as channel fading gain. By adaptively changing K based on this ratio, the proposed algorithm more effectively reduce the computation complexity compared to the conventional K-best algorithms which achieve same performance.

Calculation of the Harmonic Emission Limit for low-Voltage Electrical Equipment (국내 저압 전기기기의 고조파 유출 제한값 산정)

  • Kang, Moon-Ho;Song, Yang-Hoi;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.56-61
    • /
    • 2008
  • Because the harmonic disturbance characteristic which makes voltage drop and the deterioration of instantaneous power quality in electrical power system overheats the NGR and the customer capacitor and malfunctions the OCGR and AMR, it is necessary for electric power company to take active measures to reduce this disturbance. International Electrotechnical Commission(IEC) 61000-3-2 specifies limits for harmonic current emissions generated by low voltage(LV) electrical equipment whose input current $\leq$ 16(A) per phase. Analysis shows that limits for Class A equipment in IEC are calculated using the reference impedance of LV system and maximum permissible voltage and limits for other Classes are also calculated based on limits for Class A. Therefore we have calculated four(4) internal limits for LV electrical equipment using the korea reference impedance and maximum permissible voltage in this paper.

Discharging Voltage Control with Error Detecting for Search light of Ship (선박용 탐사조명 전원장치의 방전개시전압 제어와 조명 이상검출)

  • Park, Noh-Sik;Kwon, Soon-Jae;Lee, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.8-17
    • /
    • 2008
  • This paper presents a stable lighting method for HID lamp for ship from initial discharging current limit with discharging voltage control. The output voltage of the proposed control scheme is boosted for ignition, and the charging voltage is decreased by the resistor discharging. The proposed controller fires the initial discharge at the designed discharging voltage to limit the discharge current. After the discharging, constant current controller is used for brightness in steady state. The proposed control scheme can limit the initial discharge current using the starting point control without a complex voltage controller. so it can improve the life-time of HID lamp and get a stable discharge from restricted the initial discharge current. In order to improve the protection of the system, a simple instantaneous error detecting circuit for open state and short state of HID lamp is used. The proposed error detecting of HID lamp can protect the power system of lamp control. The effectiveness of the proposed controller is verified from the experiments of practical 2.5[kW] HID search light for ship.

Low Complexity QRD-M Detection Algorithm Based on Adaptive Search Area for MIMO Systems (MIMO 시스템을 위한 적응형 검색범위 기반 저복잡도 QRD-M 검출기법)

  • Kim, Bong-Seok;Choi, Kwonhue
    • Journal of Satellite, Information and Communications
    • /
    • v.7 no.2
    • /
    • pp.97-103
    • /
    • 2012
  • A very low complexity QRD-M algorithm based on limited search area is proposed for MIMO systems. The conventional QRD-M algorithm calculates Euclidean distance between all constellation symbols and the temporary detection symbol at each layer. We found that performance will not be degraded even if we adaptively restrict the search area of the candidate symbols only to the neighboring points of temporary detection symbol according to the channel condition at each layer. As a channel condition indicator, we employ the channel gain ratio among the layers without necessity of SNR estimation. The simulation results show that the proposed scheme effectively achieves near optimal performance while maintaining the overall average computation complexity much smaller than the conventional QRD-M algorithm.

A zero-voltage zero-current switching power conversion system for fuel cell (영전압 영전류 스위칭을 이용한 연료전지용 전력변환시스템)

  • Son, Gyoung-Jong;Song, Sung-Geun;Moon, Chae-Joo;Kim, Kwang-Heon;Lim, Young-Cheol;Choi, Joon-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.385-394
    • /
    • 2006
  • The application areas of traditional push-pull converters are limited because the voltage stress of switches is high (twice of the input voltage). But the push - pull converter topology is suitable for unregulated low-voltage to high-voltage power conversion such as the fuel cell. This paper presents a novel power converter structure that is very suitable for the DC/DC converter in fuel cell systems. Based on this structure, a ZVS- ZCS push-pull converter is proposed. The switches of the proposed push-pull converter can operate under ZVS or ZCS condition with the help of a new passive clamping circuit. The passive clamping techniques solves the voltage overshoot problem. Because the buck converter circuit operates at twice the synchronous switching frequency of the push-pull converter, the peak current in the current-fed inductor and transformer is reduced. The operation principle of the proposed converter is analyzed and verified by simulations and experimental results. A 1 kW DC/DC converter was implemented with DSP TMS320F2812, from which experimental results have shown that efficiency improvement and surge suppression can be achieved effectively.

Inrush Current Control of Matching Transformer for Dynamic Voltage Restorer (동적전압보상기를 위한 정합 변압기의 돌입전류 제어)

  • Seo, Il-Dong;Jeon, Hee-Jong;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.340-348
    • /
    • 2006
  • This paper proposes an inrush current control technique of matching transformer for configuration of dynamic voltage restorer(DVR). The DVR system consist of PWM inverter to inject arbitrary voltage, LC low pass filter as harmonic eliminator and matching transformer for isolation. However, the matching transformer has an excess of inrush current by magnetic flux saturation in the core. Due to this inrush current, the rating of matching transformers is double for needed nominal rating for protection of DVR. Therefore, in this paper, the modeling method of magnetic flux saturation is used to analyze a magnitude of inrush current, and additional current controller is used for PWM inverter output regulation. Simulation and experimental results are provided to demonstrate the validity of the proposed control method.

Design of the Fuel Cell Powered Line-Interactive UPS System (연료전지 시스템을 이용한 Line-Interactive 방식의 무정전 전원 공급 장치의 설계)

  • Choi, Woo-Jin;Jeon, Hee-Jong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.205-212
    • /
    • 2004
  • In this paper the design of a 1-[KVA] fuel cell powered line-interactive UPS system employing modular (fuel cell & DC/DC converter) blocks is proposed. The proposed system employs the two fuel cell modules along with suitable DC/DC converters and these modules share the DC-Link of the DC/AC inverter. A supercapacitor module is also employed to compensate for the instantaneous power fluctuations and to overcome the slow dynamics of the fuel processor. The energy stored in the supercapacitor can also be utilized to handle the overload conditions for a short time period. Due to the absence of batteries, the system satisfies the demand for an environmentally friendly and dean source of the energy. A complete design example illustrating the amount of hydrogen storage required for 1hr power outage, and sizing of supercacpacitor for transient load demand is presented for a 1-[KVA] UPS.

Study on Implementation of a Digital Frequency Discriminator using 4 channel Delay line (4채널 지연선로를 이용한 디지털 주파수 판별기 구현에 관한 연구)

  • Kook, Chan-Ho;Kwon, Ik-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.512-515
    • /
    • 2010
  • SIGINT(SIGnal INTelligence) includes several parameters intercepted by measurement and analysis of the RF(Radio frequency) signal from free space. One of the important parameters is frequency information. Expecially, in order to perform instantaneous frequency measurement of Radar and Missile seeker's RF signals, we use dedicated RF modules as a DFD(Digital Frequency Discriminator) to provide frequency information by measurement of the relative phase difference between signals via intended RF delay lines. It must measure and provide realtime based frequency information on short pulsed RF signal up to 100 nSec or less. This document proposes Ultra wideband DFD consisted of a RF input section of Wideband 4 channel RF delay line and correlator, a digital processing section to measure and provide frequency information from I/Q signal, and a frequency calibration section. Also, it will show design suitability based on test results measured under test condition of very short input pulse signals.

  • PDF

Design of the Robust Active Power Filter under the Unbalanced and Distorted Source Voltages in Three-phase Four-wire Systems (전원전압의 불평형 및 왜곡에 강인한 3상 4선식 전력용 능동 필터의 설계)

  • Min Joon-Ki;Kim HyoSung;Choi Jaeho;Kim Kyung-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.420-429
    • /
    • 2004
  • This paper proposes a novel current control strategy on active power filters using PQR instantaneous power theory which can compensate the line current harmonics and the neutral line current under the unbalanced and/or distorted source conditions in three-phase four-wire systems. The characteristics of the inverter ac filters are analyzed and a novel digital controller are proposed to overcome the inherent time delay problem in digital controllers with designed control gain in this paper. The proposed current control method is based on a sinusoidal PWM for fully-digital implementation compared with a conventional hysteresis PWM. PSiM simulation results verify the good performance of the proposed current control strategy on shunt type APFs.