• Title/Summary/Keyword: 순산도

Search Result 165, Processing Time 0.023 seconds

Experimental Study on the Oxygen Combustion Characteristics with $CO_2$ Feeding ($CO_2$ 첨가에 따른 순산소 연소기의 연소특성에 관한 실험적 연구)

  • Seo, Jeong-Il;Guahk, Young-Tae;Bae, Soo-Ho;Hong, Jung-Goo;Lee, Uen-Do;Shin, Hyun-Dong
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.2
    • /
    • pp.26-34
    • /
    • 2005
  • The performance of oxygen combustion with $CO_2$ feeding was investigated in a pyrex tube furnace. The inverse type multi-hole burner was used for improving mixing and wide operating range. It introduced oxygen, fuel, and oxygen, respectively, from center tube to outer tubes. Oxygen combustion characteristics with excess oxygen ratio, oxygen feeding ratio, and $CO_2$ feeding flow rate were studied to optimize the operating condition and to apply the oxygen combustion with recirculation of flue gas to a real furnace. This paper presents results on the effect of $CO_2$ feeding flow rate on the structure of the flames and concentrations of NO and CO emissions. The visible flame length was shortest due to well mixing between fuel and oxygen when the oxygen feeding ratio was 0.25. The NO emission was reduced drastically regardless of excess oxygen ratio when the $CO_2$ feeding flow rate was larger than 15 lpm. The CO emission is varied by changing the $CO_2$ feeding flow rate but the CO emission characteristics is highly affected by excess oxygen ratio. When the excess oxygen ratio is below $\lambda=1.1$, the CO emission increased as the $CO_2$ feeding flow rate increased.

  • PDF

Analysis of distortion effect of resistivity data due to 3D geometry of fill dam (필댐의 3차원 기하 효과에 따른 전기비저항 왜곡 효과 분석)

  • Oh Seokhoon;Kim Hyoung-Soo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.55-58
    • /
    • 2005
  • Low resistivity zone is observed at the lower part of a CFRD (Concrete Face Rockfill Dam). Generally, CFRD tends not to have any saturated zone within the body, but the result of resistivity survey shows that it is possible for the dam to be saturated under 20m depth with water. The level of reservoir was under 10m from the crest. We suspect that this result may come from the wrong 2D inversion process ignoring the 3D geometry of dams. For the analysis of possibility of distortion by different geometry, we perform the 3D forward modeling for the dam and apply the 2D inversion process. And then we check the point of traditional interpretation of resistivity data. By the analysis, it is found that the result of 2D inversion process of 3D geometry of dams, seems to have deep relation with the reservoir level, and the complex 3D structure hide some internal electrical anomaly of dams from resistivity information.

  • PDF

A Case of Imperforate Hymen with Hydrocolpos in a Holstein Heifer (홀스타인 미경산우에서 질수증을 동반한 무공질판막 일례)

  • Kim, Ill-Hwa;Kang, Hyun-Gu;Hur, Tai-Young
    • Journal of Veterinary Clinics
    • /
    • v.29 no.4
    • /
    • pp.348-351
    • /
    • 2012
  • A vaginal speculum examination of a 17-month-old Holstein heifer with a history of repeated artificial insemination (AI) failures via the cranial vagina revealed the presence of an intact hymen (imperforate hymen) beyond the external urethral orifice, which resembled the vaginal wall. An ultrasonographic examination detected hypoechoic fluid within the vaginal cavity between the intact hymen and the cervix, indicating the presence of hydrocolpos. After sedation and epidural anesthesia, the intact hymen was incised using a scalpel and scissors and removed, while the incised portions were sutured using a simple interrupted method. The heifer became pregnant after three consecutive estruses with the intervals of approximately 20 days and concomitant AIs. The heifer gave birth to a healthy male calf with no complications after a 291-day gestation period. This case reports the presence of an imperforate hymen with hydrocolpos in a Holstein heifer, followed by successful insemination, conception and delivery after removal of the imperforate hymen.

Treatment of Paper Mill Wastewater by the Deep Shaft Activated Sludge Process (심층폭기(深層曝氣) 활성(活性)슬러지법(法)을 이용(利用)한 제지폐수(製紙廢水)의 생물학적(生物學的) 처리(處理)에 관한 연구(研究))

  • Kim, Hwan Gi;Yang, Bong Yong;Lee, Bok Yul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.275-284
    • /
    • 1992
  • A generated problem in treated highly concentrated organic wastewater by activated sludge process is the limitation of biomass concentration and oxygen transfer capability in aeration tank. To overcome the limitation, the deep shaft activated sludge process which has high oxygen transfer capability was applied to the wastewater treatment process. This paper investigated the characteristics of liquid circulation, oxygen transfer and biological treatment of paper mill wastewater by the deep shaft activated sludge process. From the obtained results, it was found that the oxygen transfer capability in the deep shaft system was much greater than those in the conventional aeration systems and almost tantamount to the pure oxygen system. The deep shaft system could treat highly concentrated organic wastewater by higher biomass concentration and organic loading rate.

  • PDF

Oxygen Transfer Characteristics & Pure Oxygen Application Study on Circulation Flow Rate of the JLB (Jet Loop Bioreactor) (Jet 폭기 시스템의 순환유량에 따른 산소전달 특성 및 순산소 적용성 검토)

  • Park, Noh-Back;Song, Yong-Hyo;Pack, June-Gue;Jun, Hang-Bae
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.896-901
    • /
    • 2009
  • In this study, in order to apply the air and pure oxygen in the Jet Loop Reactor (JLB) in which the oxygen transfer rate is high, differentiate the operation mode according to each air flowrate and liquid flowrate and investigate the oxygen transfer characteristic, an experiment was carried out. The oxygen concentration with the air flowrate ($Q_g$) and liquid flowrate ($Q_L$) was identical but the oxygen transfer coefficient ($K_L{\cdot}a$) is linear depending on degree of two factors. The width of an increase is small in $0.1min^{-1}$ when the air flowrate is 0.2 L/min with increasing the liquid flowrate. Whereas, the increment was exposed to be very high for $1.5min^{-1}$ when the air flowrate was 5 L/min. In the experiments using the pure oxygen, it was 30 mg/L of oxygen concentration finally and it was 3.5 times than using the air. But the time reached the saturated concentration was similar to using the air, and $K_L{\cdot}a$ was similar to using the air too. Analysis between two independent variable and oxygen transfer of the correlation is the same model like $K_L{\cdot}a={0.0161Q_L}^{1.5371}{Q_g}^{0.5433}$ using with coefficient non linear regression analysis. It was resulted that the liquid flowrate were approximately three times than air flowrate on effect to oxygen transfer rate.

Comparison of Overall Oxygen Transfer Coefficient in the Membrane Coupled High Performance Reactor for a High Organic Loading Wastewater Treatment (고부하 유기성 폐수처리를 위한 분리막 결합형 순산소 고효율 포기장치의 총괄 산소전달효율 평가)

  • Kang, Bum-Hee;Lim, Kyeong-Ho;Lee, Sang-Min
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.1
    • /
    • pp.81-88
    • /
    • 2010
  • This study was conducted to find the capability of comparison of overall oxygen transfer coefficient in the membrane coupled high performance reactor (MPHCR) in treating high organic loading wastewater. Effluent quality had been analyzed while the influent organic loading rate was changed from 2 to $7kg\;COD/m^3{\cdot}day$. The oxygen transfer coefficients had been investigated using two-phase nozzle for operating variables which were internal circulation flowrate (5~8 L/min), air flow rate (0.0125~0.2 L/min), liquid temperature ($10{\sim}20^{\circ}C$), and pure-oxygen flow rate (0.0125~0.2 L/min). The overall oxygen transfer coefficient was increased with flowrate of internal circulation and air and high temperature. Especially, internal circulation flow rate showed distinct effect on overall oxygen transfer coefficient due to an increase of gas holdup and air-liquid contract area by two-phase nozzle. In the high range of organic loading rate from 4 to $7kg\;COD/m^3{\cdot}day$, the removable efficiency of COD was 91%. Conventional activated sludge process usually treat organic loading from 0.32 to $0.64kg\;COD/m^3{\cdot}day$ however, the MPHCR can treat 10 to 20 times higher if it would be compared to the conventional activated sludge process. Foaming problem often happened and caused biomass wash out of the reactor, therefore, the foaming should be controlled for the enhanced operation.

Analysis of Distortion Effect of Resistivity Data Due to 3D Geometry of Fill Dam (필댐의 3차원 기하 효과에 따른 전기비저항 왜곡 효과 분석)

  • Oh, Seok-Hoon;Kim, Hyoung-Soo
    • Journal of the Korean Geophysical Society
    • /
    • v.8 no.4
    • /
    • pp.211-214
    • /
    • 2005
  • Low resistivity zone is observed at the lower part of a CFRD (Concrete Face Rockfill Dam). Generally, CFRD tends not to have any saturated zone within the body, but the result of resistivity survey shows that it is possible for the dam to be saturated under 20m depth with water. The level of reservoir was under 10 m from the crest. We suspect that this result may come from the wrong 2D inversion process ignoring the 3D geometry of dams. For the analysis of possibility of distortion by different geometry, we perform the 3D forward modeling for the dam and apply the 2D inversion process. And then we check the point of traditional interpretation of resistivity data. By the analysis, it is found that the result of 2D inversion process of 3D geometry of dams, seems to have deep relation with the reservoir level, and the complex 3D structure hide some internal electrical anomaly of dams from resistivity information.

  • PDF

NOx Formation Characteristics with Oxygen Enrichment in Nonpremixed Counterflow Flames (비예혼합 대향류화염에서 산소부화에 따른 NOx 생성특성)

  • Lee, Chang-Eon;Hwang, Cheol-Hong;Yoo, Byung-Hun;Han, Ji-Woong
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.17-22
    • /
    • 2007
  • The NOx emission characteristics with oxygen enrichment in non-premixed counterflow flames were investigated numerically. To consider systematically the situation of inevitable $N_2$ contamination by air infiltration in the process of pure-oxygen combustion, the volume ratio of $O_2$ in an oxidizer was changed from 21% to 100%. As a result the NO emission index $(EI_{NO})$ has the highest value under condition of 75% oxygen enrichment. This result can be explained by the change of $N_2$ destruction rate with oxygen enrichment rather than flame temperature, flame thickness and residence time. In particular, it was found that the reaction of N+NO=$N_2+O$ has the largest contribution on NOx production in oxygen-enrichment flames.

  • PDF

Influence of Surrounding Gas and Coal Characteristics on Flame Propagation in Oxy-Fuel Combustion of Pulverized Coal (미분탄 순산소 연소에서 주위 기체와 석탄 특성이 화염전파에 미치는 영향)

  • Kang, Young-Min;Shim, Young-Sam;Moon, Cheor-Eon;Sung, Yon-Mo;Seo, Sang-Il;Kim, Tae-Hyung;Choi, Gyung-Min;Kim, Duck-Jool
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.1
    • /
    • pp.38-45
    • /
    • 2009
  • Oxy-fuel combustion of pulverized coal is one of the promising new technologies to reduce $CO_2$ and NOx from coal combustion. However, the stability of pulverized coal flame is reduced in the oxy-fuel combustion. This flame stability is concerned with the flame propagation that is affected by surrounding gas and coal characteristics, such as gas temperature, gas composition, coal volatile, coal activation energy and coal size. In this paper, a study on the influence of surrounding gas and coal characteristics on the flame propagation velocity in oxy-fuel combustion of pulverized coal was preformed. One dimensional model was used to calculate the flame propagation velocity of pulverized coal clouds. In this model, the radiation is considered to be the main source of heat exchange, and Monte Carlo method was adopted for accurate calculation of radiation heat flux. It was found that the flame propagation velocity become higher with the decrease of coal activation energy and the increase of coal volatile. Also, according to the increase of gas temperature and $O_2$ concentration, flame propagation velocity increased.

Selection of the Best Oxygen Carrier for Chemical Looping Combustion in a Bubbling Fluidized Bed Reactor (기포유동층에서 케미컬루핑 연소시스템을 위한 최적 산소전달입자 선정)

  • Kim, Hana;Kim, Jung-Hwan;Yoon, Joo-Young;Lee, Doyeon;Baek, Jeom-In;Ryu, Ho-Jung
    • Clean Technology
    • /
    • v.24 no.1
    • /
    • pp.63-69
    • /
    • 2018
  • The reduction reaction characteristics and physicochemical properties were studied for the selection of oxygen carrier, which is the core of the chemical looping combustion (CLC) technology. Fuel conversion and $CO_2$ selectivity of oxygen carrier according to the concentration of reducing gas and the reduction temperature using three kinds of oxygen carrier (SDN70, N018-R2, N016-R4) were measured and compared. In addition, Attrition Index (AI) and BET surface area were measured to analyze the attrition resistance and the surface characteristics of the oxygen carrier. As a result, it was confirmed that all three kinds of oxygen carrier were suitable for use in chemical roofing combustion system, and the best particle was determined to be N016-R4.