• Title/Summary/Keyword: 순간온도

Search Result 170, Processing Time 0.024 seconds

Study of spatial temperature distribution during combustion process in a high temperature and pressure constant volume chamber (고온 고압 정적 연소실에서 연소과정에 따른 온도 분포 측정)

  • Kim, Ki-hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.345-350
    • /
    • 2017
  • Downsizing is widely applied to diesel engines in order to improve fuel efficiency and reduce exhaust emissions. Engine sizes are becoming smaller but pressure and temperature inside combustion chambers are increasing. Therefore, research for fuel spray under high pressure and temperature conditions is important. A constant volume chamber which simulates high temperature and pressure likely to be found in diesel engines was developed in this study. Pressure and temperature were increased abruptly because of ignition of the pre-mixture in the constant volume chamber. Then pressure and temperature were gradually decreased due to the heat loss through the chamber wall. Fuel spray occurred when temperature and pressure were reached at the target condition. In this experiment, the temperature condition should be exactly defined to understand the relation between fuel evaporation and ambient temperature. A fast response thermocouple was developed and used to measure the temporal and spatial temperature distribution during the combustion process inside the combustion chamber. In the results, the core temperature was slightly higher than the bulk temperature calculated by the gas equation. Ed-note: do you want to say 'ideal gas equation'? This was attributed to the heat transfer loss through the chamber wall. The vertical temperature deviation was higher than the horizontal temperature deviation by 5% which resulted from the buoyancy effect.

Application of Temperature-compensated Resistivity Probe in the Field (온도보상형 전기저항 프로브의 현장 적용성 평가)

  • Jung, Soon-Hyuck;Yoon, Hyung-Koo;Lee, Jong-Sub
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4C
    • /
    • pp.117-125
    • /
    • 2011
  • The practical use of the electrical resistivity, which can makes the acquirement of the high resolution data in specific area, is increased in order to obtain a reasonable data for a ground investigation. The objective of this study is development of TRPF(Temperature-compensated Resistivity Probe for Field test), and an application in the field test for obtaining a reliable electrical resistivity value about considering the temperature effects. Temperature sensor is attached at 15mm, 30mm, 90mm below from the cone tip in consideration with the results of temperature transient process of cone probe and safety, and the angle of cone tip is $60^{\circ}$ for geometrical reason and minimizing the disturbance during the penetration test. Diameter of the cone probe is equally 35.7mm and penetration rate is 2 cm/sec for a comparison with standard cones such as CPT and SPT, and others. The temperature change is instantly observed around $4^{\circ}C$ when touching the ground, and the comparing results among the other cones indicates that the temperature compensation should be conducted in the ground survey using the electrical resistivity. This study shows that the necessity of temperature effects compensation during penetration test through the development and field verification of TRPF (Temperature-compensated Resistivity Probe for Field test).

Group Ignition of Liquid Fuel Droplets Cloud (액체연료 액적군의 집단 점화)

  • 박용열;김호영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.12
    • /
    • pp.2376-2384
    • /
    • 1992
  • A theoretical analysis is carried out to predict the characteristics of transient ignition phenomena for the spherical fuel droplets cloud with non-uniform droplet size and number density distribution. Numerical calculations are performed for various cases depending on the combinations of the major parameters such as ambient temperature and initial distributions of droplet size and number density. The results of present study show that the ignition delay decreases for higher ambient temperature and smaller droplet size. Droplets cloud of hollow type with outer concentrated distribution ignites most rapidly.

A Study on Dynamic Matrix Control using Spray and Damper to Once-through Boiler Steam Temperature (스프레이와 댐퍼를 이용한 관류 보일러 스팀 온도의 (2X2) 동역학 행렬 제어에 관한 연구)

  • Kim, Woo-Hun;Moon, Un-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.91-97
    • /
    • 2010
  • In this paper, we present simulation results of Dynamic Matrix Control (DMC) to a Once-through boiler steam temperature. In order to control the steam temperatures, we choose spray and damper as two input variables. Then, the step response model is generated for the two major output variables by step test. After that, on-line optimization is performed using $(2\times2)$ step response model. Proposed controller is applied to the APESS (Doosan company's boiler model simulator) and the simulation results show satisfactory performance of proposed control.

Measurement of Food Process Variables with Microcomputer (마이크로컴퓨터를 이용한 식품공정의 변수계측)

  • Kang, Jun-Soo;Suh, Myung-Gyo;Chung, Shin-Kyo;Choi, Jong-Uck
    • Korean Journal of Food Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.524-527
    • /
    • 1992
  • To measure of important variables such as temperature, weight, and relative humidity in food processing process, computer-aided data acquisition system was composed of 16 bit microcomputer and PCL-711S interface board. Process variables in dehydration and storage of food were measured through sensors, converters, and computer system which were operated by the PC-LabDAS software for data acquisition, process control, and data analysis. The relationship between measured values of process variables and the output voltages of ADC showed more than 0.99 in $r^2$ value. Response time of sensors was enough fast to measure minute values changed in a moment.

  • PDF

Assessment of SCDAP Using the Full-Length High-Temperature FLHT-2 Test (FLHT-2 실험결과를 이용한 SCDAP코드 평가)

  • Park, Choon-Kyung;Park, Jong-Hwa;Yoo, Kun-Jung;Chae, Sung-Ki
    • Nuclear Engineering and Technology
    • /
    • v.20 no.1
    • /
    • pp.54-64
    • /
    • 1988
  • This paper assesses the models in the SCDAP code using the results of the FLHT-2 test. Calculations show that the SCDAP correctly predicts Ire temperatures, oxidation front movement, overall hydrogen generation and peak generation rate, internal fuel rod pressure, and cladding rupture due to ballooning. A comparison of the calculated results with measured data shows that two phase level is underpredicted, and that radiation heat transfer and auto-catalytic reaction temperature of zircaloy are overpredicted. These models are recommended to be modified. The analysis also shows that the simulation of the gap in a fuel rod improves the code prediction on core damage progression.

  • PDF

전극물질에 따른 단전극 대기압 제트 플라즈마 스트리머 동역학 연구

  • Park, Sang-Hu;Lazovic, Sasa;Jeong, Hui-Su;Chae, Gil-Byeong;Cvelbar, Uros;Choe, Won-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.554-554
    • /
    • 2013
  • 대기압 제트 플라즈마를 저주파(수-수십 kHz) 전압에서 구동 시, 일반적으로 '스트리머(streamer)'혹은 '플라즈마 총알(plasma bullet)'로 불리는 현상이 특정 운전조건에서 관찰된다. 본 연구에서는 동일 구조의 Ta, Ti, stainless steel, brass, Cu, Ni 전극을 이용하여 전극물질에 따른 대기압 제트 플라즈마의 특성 변화를 분석하였다. 각각의 물질은 서로 다른 이차전자방출계수, 일함수, 전기전도도 등 고유한 성질이 다르기 때문에 이들 전극을 이용하여 발생시킨 제트 플라즈마 역시 다른 특성을 갖는다. Acton SpectroPro750 분광기를 이용하여 얻은 플라즈마 방출광스펙트럼으로부터 구한 전자 여기온도(Texc=680~720 K)와 OH의 분자 회전온도(Trot=350~380K)는 물질에 따라 큰 변화를 보이지 않았으나, 발생된 스트리머 거동에서 큰 차이를 확인하였다. ICCD 카메라를 이용한 시간 분해된 이미지에서 전극물질에 따른 첫 번째 스트리머의 발생시간 및 스트리머 속력, 두 번째 스트리머의 분리시간이 모두 다른 것을 확인하였다. 제일 차이가 심하게 나타나는 Ti과 Cu의 경우 첫 스트리머의 발생시간 차이는 약 $1{\mu}s$이며, 평균속력 및 순간속력이 약 2 km/s 차이가 났다. 이 결과를 통해 물질의 이차전자방출계수 및 일함수가 대기압 제트 플라즈마에서 스트리머 발생에 영향을 주는 것을 알았고, 다른 전극물질을 사용한 제트 플라즈마의 특성이 다름에 따라 여러 응용에서의 결과에도 영향을 미칠 것이라생각한다.

  • PDF

Effect of Pulse Magnetic Field Stimulus on Blood Flow using Digital Infrared Thermal Imaging (체열진단을 통한 펄스자기장 자극기의 혈류개선효과 고찰)

  • Lee, Hyun-Sook
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.5
    • /
    • pp.180-184
    • /
    • 2011
  • The changes in the blood flow in the peripheral vascular system under strong pulsed magnetic fields (pMF) were studied by digital infrared thermal imaging (DITI). After pMF stimulus temperatures in stimulated area were commonly increased in both groups of age and gender. In order to reduce heat generated from coil in pMF stimulus system plastic moldings were fabricated, so that certain distance was kept between stimulus system and the skin and to prevent direct contact to the skin. It is believed that skin temperature is increased by internal electromagnetic energy stimulated the peripheral vascular system by non-contact method.

A new formulation for unsteady heat transfer of oscillatory flow in a circular tube (원관내 왕복유동에서 비정상 열전달 관계식의 공식화)

  • Park, Sang-Jin;Lee, Dae-Yeong;No, Seung-Tak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.9
    • /
    • pp.2953-2964
    • /
    • 1996
  • Heat Transfer with periodic fluctuation of fluid temperature caused by oscillatory flow or compression expansion can be out of phase with balk fluid-wall temperature difference. Newton's law of convection is inadequate to describe this phenomenon. In order to solve this problem the concept of the complex Nusselt number has been introduced by severla researchers. The complex Nusselt number expresses out of phase excellently while the first harmonic is dominant in the variations of both fluid-wall temperature difference and heat flux. However, in the case of oscillatory flow with non-linear wall temperature distribution, the complex Nusselt number is not appropriate to predict the heat transfer phenomena since the higher order harmonic components appear in periodic temperature variation. Analytic solutions to the heat transfer with an sinusoidal well temperature distribution were obtained to investagate the effect of non-linear wall temperature distribution. A new formula considering the thermal boundary layer was suggested based on the solutions. A comparison was also made with the complex Nusselt number. It was verified that the new formula describes well the heat transfer of oscillating flow even if the first harmonic component is not dominant in the fluid-wall temperature difference.

진공 플라즈마 용사코팅시 분말 이송가스 유량이 적층효율에 미치는 영향

  • Jeong, Yeong-Hun;Nam, Uk-Hui;Byeon, Eung-Seon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.161-161
    • /
    • 2014
  • 열플라즈마는 주로 아크 방전에 의해 발생시킨 전자, 이온, 중성입자(원자 및 분자)로 구성된 부분 이온화된 기체로, 국소열평형상태를 유지하여 구성입자가 모두 수천에서 수만도에 이르는 같은 온도를 갖는 고속의 제트 화염 형태를 이루고 있다. 이렇게 고온, 고열용량, 고속, 다량의 활성입자를 갖는 열플라즈마의 특성을 이용하여, 종래 기술에서는 얻을 수 없는 다양하고 효율적인 산업적 이용이 활발히 진행되고 있다. 용사코팅은 노즐 출구를 통해서 외부로 방출되는 열 플라즈마 화염을 이용하는 것으로 이 화염의 와류 특성으로 인하여 외기의 가스가 화염내부로 침투하는 특성을 가진다. 이러한 현상은 열원의 냉각효과 외에도 외기를 구성하는 기체 분자의 내부 유입을 의미하는 것으로 대기 상태에서 공정이 이루어진다면 열원 내로 유입되는 대기 내의 산소가 모재 표면과 반응하여 산화가 진행된다. 이러한 산화과정은 용사 코팅의 품질을 저하시키는 요인이 되므로, W, Ti 등과 같은 반응성이 높은 재료의 코팅은 산화과정을 방지하기 위하여 진공에서 코팅을 하여야만 한다. 진공 플라즈마용사코팅은 진공 또는 저압의 불활성 분위기 중에서 열플라즈마 화염에 용사재료를 투입하여 플라즈마 화염 내부에서 순간적으로 이를 용융시킨 후 고속으로 분출, 모재에 적층시키는 코팅공정이다. 이때 분말상의 용사재료를 고속으로 화염 중심에 투입하여 최대 에너지 전달이 이루어지도록 하는 것이 적층효율 및 코팅품질을 향상에 필수적이다. 하지만 플라즈마 화염 내부를 고속으로 이동하는 입자의 온도와 속도 및 궤적을 측정하여 제어하는 것은 매우 어렵기 때문에, 통상 형성된 코팅의 구조와 두께로부터 경험적으로 파라미터를 결정하는 것이 일반적이다. 본 연구에서는 초고속 레이저 카메라와 이미지 분석용 소프트웨어를 이용하여 플라즈마 화염내의 비행입자 궤적을 추적하고, 이를 통해 분말 이송가스의 유량이 코팅 효율 및 미세구조에 미치는 영향을 조사하였다. 플라즈마 화염은 중심부가 가장 높은 온도와 속도를 가지고 있기 때문에, 분말 이송가스의 유량이 적을 경우 투입된 분말은 단지 플라즈마 화염의 상부 경계면을 지나는 궤적을 갖게된다. 이로 인해 분말의 용융이 충분히 이루어지지 않아 적층 효율이 낮고 미용융 입자 및 기공이 많은 미세구조를 보였다. 이송가스 유량을 증가시키게 되면, 분말의 궤적은 플라즈마 화염의 중심부를 지나게 되어 적층 효율이 증가하고 미세구조 또한 개선되었다. 하지만 이송가스 유량이 지나치게 클 경우, 투입된 분말 입자는 플라즈마 화염을 조기에 관통하게 되어 비행궤적은 온도와 속도가 낮은 영역에 형성되었다.

  • PDF