• Title/Summary/Keyword: 수평전단력

Search Result 114, Processing Time 0.031 seconds

Approximate Analysis of Shear Wall-Frame Structure For Seismic Design (전단벽-골조 시스템의 내진설계를 위한 근사해석법)

  • Yoo, Suk-Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.99-106
    • /
    • 2019
  • A wall-frame structure resists horizontal load by the interaction between the flexural mode of the shear wall and the shear mode of the frame, which implies that the frame deflects only by reverse bending of the columns and girders, and that the columns are axially rigid. However, as the height of frame increases the shear mode of frame changes to flexural mode, which is due to the extension and shortening of the columns. An approximate hand method for estimating horizontal deflection and member forces in high-rise shear wall-frame structures subjected to horizontal loading is presented. The method is developed from the continuous medium theory for coupled walls and expressed in non-dimensional structural parameters. It accounts for bending deformations in all individual members as well as axial deformations in the columns. The deformations calculated from the presented approximate method and matrix analysis by computer program are compared. The presented approximate method is more accurate for the taller structures.

Shear Performance of Post and Beam Construction by Pre-Cut Process (프리컷 방식을 적용한 기둥-보 공법의 수평전단내력)

  • Hwang, Kweonhwan;Park, Joo-Saeng;Park, Moon-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.1-12
    • /
    • 2007
  • For the purpose of effective utilization of domestic second-grown larch as structural members, post and beam construction applying traditional construction to Japanese larch glulam members was adopted with processing by machine pre-cut method. In general, horizontal shear test by KS F 2154 is conducted to assess the horizontal shear properties of the wooden structure by post and beam construction. The frame was consisted of post and beam member with appropriate fasteners, and members have their own processed parts (notch, hole, etc.) that can be well-connected each other. The shear wall was consisted of the frame with screw-nail sheathed panel (OSB). The results of horizontal shear loading tests without vertical loads conducted on the frame and the shear wall structures, the maximum strengths were about 1.9 kN/m and about 9.7 kN/m, the shear rigidities were about 167 kN/rad, 8198 kN/rad, respectively. The strength proportion of the frame specimen was about 20% of the wall's and about 2% in initial stiffness. Nail failures are remarkable on the shear wall specimen with punching shears and shear failures. The shear load factor for the shear wall specimen by the method of Architectural Institute of Japan was 1.5, which was obtained by the bi-linear method. Loading method should be considered to obtain smooth load-deformation relationship. For the better shear performance of the structures, column base and post and beam connections and sheathed panel should be further examined as well.

Shear Capacity Evaluation of Steel Plate Anchors Using Folded Steel Plate in AU-composite Beam (절곡 강판을 이용한 AU합성보 덮개형 강재앵커의 전단성능 평가)

  • Lim, Hwan Taek;Choi, Byong Jeong
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.5
    • /
    • pp.389-400
    • /
    • 2017
  • Based on U-shaped composite beam, the new form of AU-composite beam were developed to create economical and efficient components reducing the cost and shortening the length of construction work. Because the U-shaped sections are open and needs to be fixed by topping concrete securely. Therefore, it is required to maintain the U-shaped sections in a structure and to work in the safe condition through construction. It also requires accessories that resist the horizontal shear force for synthesis between the top and bottom of the U-shaped section. To reinforce these shortcomings, a shear connector has been developed with various purposes of steel plate anchors. In this study, the steel plate anchors were directly tested and the shear force was evaluated by the horizontal shear force. The experiment was divided into two types, depending on the applicable deck plates. As a result of the experiment, the continuous type specimens showed greater resistance in both strength and displacement than the ones of stud anchor specimen. In discontinuous type case, due to shear simulations and simple element analysis, the less increase the ratio of width to height and the more shear strength decreased. Thus, the shear strength equation of the stud anchor was modified to suggest the new shear strength based on the testing results.

선박 접이안용 계선주 성능 평가에 관한 연구

  • Yu, Yong-Ung;Lee, Yun-Seok
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2017.11a
    • /
    • pp.121-123
    • /
    • 2017
  • 계선주는 선박이 접안 중 안전성을 확보하는 설비로서 계류안전성 평가에 필수 설비 중 하나이다. 이러한 계선주는 국내 항만 및 어항설계 기준의 견인력에 따라 규격이 구분되어 설치되나 규격별 성능 확인을 위한 평가 방법이 제시되지 않아 평가 방법 검토가 필요하다. 이 연구에서는 견인력에 따라 설치되는 계선주 규격별 제원을 분석하여 재질과 특성에 따라 견인력에 따라 작용하는 수평력과 수직력을 휨 응력과 전단 응력으로 나누어 분석하고 이에 따른 성능 적정성을 평가하고 살제 허용 견인력을 평가 하고자 하였다. 또한 계선주 설치 후 노후화로 인한 성능 변경을 평가하고 예측하고자 두께를 통한 평가 방안을 검토하고자 하였다.

  • PDF

Effects of Wall Boundary Condition on Velocity Distribution of Shallow Water Flow (벽면경계조건이 천수흐름 유속분포에 미치는 영향)

  • Seo, Il-Won;Song, Chang-Geun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.189-193
    • /
    • 2010
  • RMA-2, Telemac-2D, River2D 등 기존의 대부분 국내외 상용모형에서는 내부 경계인 하천구조물과 외부 경계인 측벽에서의 경계조건을 활동조건(slip condition)으로 가정하여 흐름장을 계산하였다. 그러나 실제로 벽면에서는 마찰력에 의해 흐름이 존재하지 않는 무활조건(no slip condition)이 물리적으로 타당하다. 따라서 본 연구에서는 내부구조물인 교각이 존재하는 영역에서의 수평 2차원 유속분포를 구하기 위해 천수방정식을 Galerkin법과 Newton-Raphson법에 의해 이산화한 수치모형을 개발하였다. Yulistiyanto 등(1998)이 수치모의 및 수리실험에 사용한 조건을 채택하여 벽면에서의 접선방향 유속이 존재하는 활동조건과 벽면에서 유속이 없는 무활조건을 부여하고 교각을 포함한 수로에서 유속, 수위 및 전단분포를 해석하였다. 활동경계조건을 적용한 경우 교각 표면을 따라 큰 유속이 분포하고 후면에서도 관성력에 의해 흐름방향 유속이 두드러지게 나타났으나 무활조건을 적용한 경우 교각 후면에서 와가 형성되고 후류현상이 두드러지게 나타났다. 무활조건을 적용한 경우 교각 전면부에서는 선수파(bow wave)가 4 cm정도 높게 나타났으며 교각 측면부에서는 2 cm 높게 나타났다. 반면 교각 후면에서는 후류의 영향으로 수면이 2 cm 낮게 분포하였다. 교각부에 작용하는 전단력을 분석한 결과 무활조건을 적용한 경우가 활동조건을 적용한 경우에 비해 최대 6배 높은 전단력이 나타났다.

  • PDF

Strengthening of shear resistance of masonry walls (조적벽체의 전단강도 향상 방안에 관한 연구)

  • Kang, Sung-Hun;Hong, Sung-Gul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.193-196
    • /
    • 2008
  • This paper presents an experimental study to investigate enhanced performance of the masonry walls strengthened in shear and ductility using honeycomb steel mesh. The performance of masonry walls strengthened with steel mesh will compare with unreinforced masonry walls to show the performance of reinforced masonry walls. According to the experiment, it is expected that this system is effective to enhance the shear strength and ductility of the masonry walls.

  • PDF

Flexural Testing of Asymmetric Hybrid Composite Beams Fabricated from High-strength Steels (고강도강재를 적용한 비대칭 하이브리드 합성보의 휨거동 실험)

  • Jun, Su Chan;Han, Kyu Hong;Lee, Cheol Ho;Kim, Jin Won
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.3
    • /
    • pp.217-228
    • /
    • 2017
  • Full-scale flexural testing of asymmetric H-shape hybrid composite beams was conducted in this study. In fabricating hybrid H-shape sections, high strength steels were utilized for the bottom flange while ordinary strength steels were used for the top flange and web. With adding a fully composite floor slab, a total of 8 hybrid composite beam specimens were tested. The primary objective was to develop the asymmetric hybrid H-shape composite beams with maximized flexural efficiency and investigate their flexural behavior. Not all the hybrid composite specimens tested in this study exhibited the plastic moment and reasonable deformability. In the specimens with high-strength bottom flange, the longitudinal shear crack of the slab along the beam axis often preceded the development of beam plastic moment, although the slab was designed as fully composite. The mechanical reason for this unexpected behavior is discussed. It is emphasized that the longitudinal shear strength of composite slab should be checked in designing hybrid composite beams utilizing high strength steels like in this study.

An Estimation of Shear Capacity of Hexagonal Masonry Walls Under Cyclic Loading (반복하중을 받는 육각형 블록 벽체 전단내력평가)

  • Chang, Gug-Kwan;Seo, Dae-Won;Han, Tae-Kyoung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.205-214
    • /
    • 2010
  • Masonry structures have been used throughout the world for the construction of residential buildings. However, from a structural point of view, the masonry material is characterized by a very low tensile strength. Moreover, the bearing and shear capacity of masonry walls have been found to be vulnerable to earthquakes. In this study, to improve the seismic performance of masonry walls, hexagonal blocks were developed and six masonry walls made with hexagonal block were tested to failure under reversed cyclic lateral loading. This paper focuses on an experimental investigation of different types of wall with hexagonal blocks, i.e. walls with different hexagonal blocks and with different reinforcing bar arrangements, subjected to applied cyclic loads. The cracking, damage patterns and hysteretic feature were evaluated. Results from the hexagonal masonry wall were shown more damage reduction and less brittle failure in comparison to the existing rectangular masonry walls.

Composite Behavior of Perfobond Rib Shear Connector for Steel-concrete Decks (강-콘크리트 합성 바닥판용 전단연결재의 합성 거동 연구)

  • Kim, Hyeong-Yeol;Koo, Hyun-Bon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1A
    • /
    • pp.91-97
    • /
    • 2006
  • This paper presents the results of push-out test conducted for the perfobond rib shear connectors welded onto steel-concrete composite deck. Push-out test specimen consists of profiled steel sheeting, perfobond rib, reinforcement, and concrete. To provide longitudinal shear resistance between the profiled sheeting and the concrete, perfobond rib with a number of holes was used. The parameters considered in the design of perfobond rib were the spacing and location of holes, and effect of reinforcing bars placed in the holes. To validate the effectiveness of the proposed system, twelve specimens were fabricated and tested. Although the scope of test was limited in nature, the results of test have shown that the perfobond ribs can be effectively used for shear connection in the steel-concrete composite decks.

Behavior of Precast Prestressed Concrete Pavements under Post-Tensioning (프리캐스트 프리스트레스트 콘크리트 포장의 긴장에 의한 거동 해석)

  • Kim, Seong-Min;Cho, Byoung-Hooi
    • International Journal of Highway Engineering
    • /
    • v.9 no.3
    • /
    • pp.135-143
    • /
    • 2007
  • The pavement system constructed by tieing a number of precast concrete slabs employing prestressing techniques is called the precast prestressed concrete pavement. The behavior of this type of pavement system under post-tensioning was analyzed using a finite element model. First, the optimal number of anchors was determined by investigating the distribution of compressive stresses in the pavement system due to post-tensioning. Then, the effects of the parameters such as the horizontal resistance of underlying layers, the pavement length, the slab thickness, and the bearing area of the anchorage on the distribution of compressive stresses were analyzed. The horizontal resistance of underlying layers induced the loss of compressive stresses, and the loss increased in the middle of the pavement. As the pavement length increased or the slab thickness decreased, the stress loss due to the horizontal resistance of underlying layers became larger. However, the bearing area of the anchorage where the compressive forces were applied did not much affect the distribution of compressive stresses.

  • PDF