• Title/Summary/Keyword: 수평응답

Search Result 195, Processing Time 0.022 seconds

Second Order Elastic Analysis of Superstructures on Very Large Floating Structure with Semi-Rigid Connections (반강접 접합부를 적용한 초대형 부유식 구조물 상부구조체의 2차 탄성해석)

  • Song, Hwa-Cheol;Lee, Eun-Suk
    • Journal of Navigation and Port Research
    • /
    • v.27 no.1
    • /
    • pp.63-70
    • /
    • 2003
  • If semi-rigid connections are used for superstructures of very large floating structures (VLFS), the number of rigid connections can be reduced and more economical construction will be possible. In this study, considering service load and wave load in VLFS, the applicability of mixed use of rigid and semi-rigid connections have been studied using three types of connections for a four-bay eight-story frame. Three types of connections are used; top and seat-angle connections with double web-angle(TSD), extended end plate connections, steel tubular column with square external-diaphragm connections. ABAQUS(Finite element analysis program) is used for conducting second order elastic analysis.

Evaluation of the Strength Required in Current Seismic Design Code (현행 내진설계 규준의 수평강도 요구에 대한 평가)

  • 한상환;오영훈;이리형
    • Computational Structural Engineering
    • /
    • v.10 no.4
    • /
    • pp.281-290
    • /
    • 1997
  • Current seismic design code is based on the assumption that the designed structures would be behaved inelastically during a severe earthquake ground motion. For this reason, seismic design forces calculated by seismic codes are much lower than the forces generated by design earthquakes which makes structures responding elastically. Present procedures for calculating seismic design forces are based on the use of elastic spectra reduced by a strength reduction factors known as "response modificaion factor". Because these factors were determined empirically, it is difficult to know how much inelastic behaviors of the structures exhibit. In this study, lateral strength required to maintain target ductility ratio was first calculated from nonlinear dynamic analysis of the single degree of freedom system. At the following step, base shear foeces specified in seismic design code compare with above results. If the base shear force required to maintain target ductility ratio was higher than the code specified one, the lack of required strength should be filled by overstrength and/or redundancy. Therefore, overstrength of moment resisting frame structure will be estimated from the results of push-over analysis.

  • PDF

Hydroelastic Vibration Analysis of Three Dimensional Submerged Structure (3차원 접수구조물의 유체탄성 진동해석)

  • 정기태;강호승;김영복
    • Computational Structural Engineering
    • /
    • v.4 no.1
    • /
    • pp.20-27
    • /
    • 1991
  • 본 논문에서는 유체-구조 상호작용해석의 일종의 3차원 접수구조물의 진동해석을 효과적으로 수행하기 위한 해석방법을 제시하기 위하여 동적재해석기법을 검토하였다. 접수구조물의 유한구조 상호작용해석 결과는 구조진동의 관심 주파수역에서는 3차원 연성 부가수질량으로 표현되는 관성력으로 나타난다. 따라서 구조질량행렬에 부가수질량 행렬이 더해져서 전체 관성력으로 표현된다. 이 부가수질량을 추가질량으로 보고 재해석기법을 응용하는 방법을 수치실험을 통해 검증하였다. 이 때 재해석기법이 갖추어야 할 조건은 원구조의 질량과 거의 같은 정도의 질량이 추가되고 또한 완전 연성질량이 추가된 경우에도 정확한 해를 주어야 한다는 것이다. 이를 검증하기 위해 직접재해석기법과 섭동법을 이용한 재해석기법으로 4질량 스프링지지구조에 대한 해석을 수행한 결과 직접재해석기법의 응용이 적합함을 쉽게 입증할 수 있었다. 접수구조물의 예로는 3차원 잠수주상체에 대해 접수진동해석을 수행하였으며 그 결과 선체진동해석에 전통적으로 이용되고 있는 2차원 부가수질량과 3차원 수정계수를 사용한 기준차수법에서는 수지모드와 수평-비틔 연성모드와 같이 서로 독립적인 모드에 대해서는 따로 진동해석을 수행해 주어야 하는 단점이 발견되었다. 이 단점을 보완한 각 모드의 3차원 수정계수행렬을 이용한 재해석기법을 도입하여 모드에 상관없이 동시에 해를 구할 수 있었다. 그러나, 이 방법은 3차원 수정계수가 구해져 있는 경우에 한해서만 적용가능하며 실제 선체진동의 경우에는 10Hz 미만의 저차 주선체 진동에 한해서만 적용가능한 방법이다. 고차의 진도옴드에는 3차원 수정계수를 구할 수 없기 때문에 유체-구조 상호작용 해석결과로부터 얻은 3차원 연성 부가수질량을 이용하게 되며 이 때 이 행렬이 접수구조 표면의 전 자유도와 연성되어 있기 때문에 방대한 방정식을 푸어야 하지만 직접재해석기법을 적용함으로써 정확한 해를 구할 수 있었다. 또한 3차원 부가수질량을 이용한 직접재해석기법은 종래의 2차원 부가수질량과 3차원 수정계수를 이용한 방법에 비해 해석시간 면에서도 전혀 불리한 점이 없는 경제적 방법임이 밝혀졌다. 앞으로 Slamming 혹은 수중폭파 등의 충격하중에 의한 천이 구조응답 해석을 위한 효과적인 방법에 대해서도 연구결과를 발표할 계획이다.

  • PDF

PRML detection scheme with modified trellis for a MTR code (MTR 코드를 위한 변형된 트렐리스를 갖는 PRML 검출 방법)

  • Lee Joo hyun;Lee Jea jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.12C
    • /
    • pp.1601-1605
    • /
    • 2004
  • When codeword sequence has two or less successive transitions, the performance of 4th-order partial response maximum-likelihood (PRML) detector can be improved. However, the code leads to an unacceptable loss of performance due to the low code rate. For a rate 718 code that MTR constraint (i) of each codeword is limited to 2, and j is allowed to be 3 when codewords are connected, we modified the trellis of PRML detector to combine j=2 with J=3. We confirmed that the rate 718 coded 4th-order PRML detection with combined trellis achieves the SNR gain more than 2dB compared to the rate 819 coded 4u_order PRML detection at 10-s BER in high-density longitudinal or perpendicular magnetic recording systems.

Study on the Rolling Noise Model Using an Analysis of Wheel and Rail Vibration Characteristics (철도 차륜 및 레일 진동 특성 해석을 통한 전동 소음 모델 연구)

  • Jang, Seungho;Ryue, Jungsoo
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.3
    • /
    • pp.175-182
    • /
    • 2013
  • Rolling noise is an important source of noise from railways; it is caused by wheel and rail vibrations induced by acoustic roughness at the wheel/rail contact. To reduce rolling noise, it is necessary to have a reliable prediction model that can be used to investigate the effects of various parameters related to the rolling noise. This paper deals with modeling rolling noise from wheel and rail vibrations. In this study, the track is modeled as a discretely supported beam by regarding concrete slab tracks, and the wheel vibration is simulated by using the finite element method. The vertical and lateral wheel/rail contact forces are modeled using the linearized Hertzian contact theory, and then the vibration responses of the wheel and rail are calculated to predict the radiated noise. To validate the proposed model, a field measurement was carried out for a test vehicle. It was found that the predicted result agrees well with the measured one, showing similar behavior in the frequency range between 200 and 4000 Hz where the rolling noise is prominent.

A Study on the Characteristics of Bi-directional Responses by Ground Motions of Moderate Magnitude Earthquakes Recorded in Korea (우리나라에서 계측된 중규모 지진 지반운동의 수평 양방향 응답 특성 분석)

  • Kim, Jung Han;Kim, Jae Kwan;Heo, Tae Min;Lee, Jin Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.5
    • /
    • pp.269-277
    • /
    • 2019
  • In a seismic design, a structural demand by an earthquake load is determined by design response spectra. The ground motion is a three-dimensional movement; therefore, the design response spectra in each direction need to be assigned. However, in most design codes, an identical design response spectrum is used in two horizontal directions. Unlike these design criteria, a realistic seismic input motion should be applied for a seismic evaluation of structures. In this study, the definition of horizontal spectral acceleration representing the two-horizontal spectral acceleration is reviewed. Based on these methodologies, the horizontal responses of observed ground motions are calculated. The data used in the analysis are recorded accelerograms at the stations near the epicenters of recent earthquakes which are the 2007 Odeasan earthquake, 2016 Gyeongju earthquake, and 2017 Pohang earthquake. Geometric mean-based horizontal response spectra and maximum directional response spectrum are evaluated and their differences are compared over the period range. Statistical representation of the relations between geometric mean and maximum directional spectral acceleration for horizontal direction and spectral acceleration for vertical direction are also evaluated. Finally, discussions and suggestions to consider these different two horizontal directional spectral accelerations in the seismic performance evaluation are presented.

Electro-optical characteristic analysis of liquid crystal cell using UV-treated self assembled monolayer (UV 처리된 자기 조립 단분자막을 사용한 액정 셀의 전기광학특성 분석)

  • Chan-Woo Oh;Hong-Gyu Park
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.2
    • /
    • pp.109-115
    • /
    • 2023
  • In this paper, we demonstrated the orientation characteristics of liquid crystals using UV-treated FSAM as alignment layer. Moreover we confirmed the FSAM properties before and after UV treatment on indium tin oxide (ITO) glass substrates using physicochemical analysis. The hydrophobic property of the FSAM surface is change to hydrophilic through UV treatment. After UV treatment the LC molecules also were uniformly and horizontally aligned on the FSAM surfaces and the pretilt angle was obviously changed 90° degrees to 0° degrees. EO characteristic of TN cell which was fabricated with UV-treated FSAM was faster response time compare to conventional PI layer. The FSAM before and after UV treatment has a superior application potential as the LC alignment layer for LCD, potentially replacing the conventional polyimide layer.

A Parametric Study on the Seismic Response Analysis of LNG Storage Tank with Disconnected Pile Foundation Subjected to Horizontal Seismic Input Considering Fluid-Structure-Soil Interaction (유체-구조물-지반 상호작용을 고려한 비결합 말뚝기초에 지지된 LNG 저장탱크의 수평지진입력에 대한 지진응답 매개변수해석)

  • Son, Il-Min;Kim, Jae-Min
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.1
    • /
    • pp.21-32
    • /
    • 2024
  • This study performed the seismic response analysis of an LNG storage tank supported by a disconnected piled raft foundation (DPRF) with a load transfer platform (LTP). For this purpose, a precise analytical model with simultaneous consideration of Fluid-Structure Interaction (FSI) and Soil-Structure Interaction (SSI) was used. The effect of the LTP characteristics (thickness, stiffness) of the DPRF system on the seismic response of the superstructure (inner and outer tanks) and piles was analyzed. The analytical results were compared with the response of the piled raft foundation (PRF) system. The following conclusions can be drawn from the numerical results: (1) The DPRF system has a smaller bending moment and axial force at the head of the pile than the PRF system, even if the thickness and stiffness of the LTP change; (2) The DPRF system has a slight stiffness of the LTP and the superstructure member force can increase with increasing thickness. This is because as the stiffness of the LTP decreases and the thickness increases, the natural frequency of the LTP becomes closer to the natural frequency of the superstructure, which may affect the response of the superstructure. Therefore, when applying the DPRF system, it is recommended that the sensitivity analysis of the seismic response to the thickness and stiffness of the LTP must be performed.

A Study on the Dynamic Behavior Characteristics of a Small Fishing Crane (소형 어로 크레인의 동적 거동 특성에 관한 연구)

  • 이원섭;이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.163-173
    • /
    • 2001
  • The dynamic behavior characteristics of a small fishing crane for inshore and coastal fishing vessels was experimentally analyzed in order to improve the fishing operation and to reduce considerably manual work of fisherman. The small fishing crane was designed to be controlled electro-hydraulically by means of proportional valves and solenoid valves, and also to be controlled the speed of each operation. The dynamic behavior characteristics was investigated by measuring the changes of parameters such as oil pressure, swing angle of load, load tension, the lifting angle and the swing angle of crane arm when the arms extended in a side way was given a test load. The results obtained are summarized as follows: 1. The designed small fishing crane can be proportionally controlled by means of proportional valves and rapidly by operating the solenoid valves, respectively. The capacity, turning angle, maximum reach of crane were 2 T-M, $180^\circ$, 3.7m, respectively. 2. The vertical change of crane arm on the extension of lifting cylinder was $1.2^\circ$/cm, and the swing speed of crane arm due to the extension of swing cylinder by on/off operations of solenoid valves was $15^\circ$/sec, with the swing period of 1.4 sec and the angle fluctuation of $\pm$11.0$^{\circ}$. 3. When changing simultaneously the horizontal and vertical positions of the lifting load by on/off operations of solenoid valves, the swing and lifting speeds of crane arm were $4.46^\circ$/sec and $6.4^\circ$/sec, respectively. 4. The movements of the designed crane were particularly smooth as they are controlled with the aid of proportional valves than by means of solenoid valves.

  • PDF

Seismic response characteristics of the hypothetical subsea tunnel in the fault zone with various material properties (다양한 물성의 단층대를 통과하는 가상해저터널의 지진 시 응답 특성)

  • Jang, Dong In;Kwak, Chang-Won;Park, Inn-Joon;Kim, Chang-Yong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1061-1071
    • /
    • 2018
  • A subsea tunnel, being a super-sized underground structure must ensure safety at the time of earthquake, as well as at ordinary times. At the time of earthquake, in particular, of a subsea tunnel, a variety of response behaviors are induced owing to relative rigidity to the surrounding ground, or difference of displacement, so that the behavior characteristics can be hardly anticipated. The investigation aims to understand the behavior characteristics switched by earthquake of an imaginary subsea tunnel which passes through a fault zone having different physical properties from those of the surrounding ground. In order to achieve the aim, dynamic response behaviors of a subsea tunnel which passes through a fault zone were observed by means of indoor experiments. For the sake of improved earthquake resistance, a shape of subsea tunnel to which flexible segments have been applied was considered. Afterward, it is believed that a D/B can be established through 3-dimensional earthquake resistance interpretation of various grounds, on the basis of verified results from the experiments and interpretations under various conditions. The present investigation performed 1 g shaking table test in order to verify the result of 3-dimensional earthquake resistance interpretation. A model considering the similitude (1:100) of a scale-down model test was manufactured, and tests for three (3) Cases were carried out. Incident seismic wave was introduced by artificial seismic wave having both long-period and short-period earthquake properties in the horizontal direction which is rectangular to the processing direction of the tunnel, so that a fault zone was modeled. For numerical analysis, elastic modulus of the fault zone was assumed 1/5 value of the modulus of individual grounds surround the tunnel, in order to simulate a fault zone. Resultantly, reduced acceleration was confirmed with increase of physical properties of the fault zone, and the result from the shaking table test showed the same tendency as the result from 3-dimensional interpretation.