Abstract
If semi-rigid connections are used for superstructures of very large floating structures (VLFS), the number of rigid connections can be reduced and more economical construction will be possible. In this study, considering service load and wave load in VLFS, the applicability of mixed use of rigid and semi-rigid connections have been studied using three types of connections for a four-bay eight-story frame. Three types of connections are used; top and seat-angle connections with double web-angle(TSD), extended end plate connections, steel tubular column with square external-diaphragm connections. ABAQUS(Finite element analysis program) is used for conducting second order elastic analysis.
Keywords
Semi-Rigid Connections; Wave Load; Second Order Elastic Analysis; Very Large Floating Structures;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Chan, S. L. and Chui, P. P. T.(2000). "Non-Linear Static and Cyclic Analysis of Steel Frames with Semi-Rigid Connections", Amsterdam; New York: Elsevier
2 Chen, W.F., and Kishi, N.(1986). "Data Base of Steel Beam -to-Column Connections", Structural Engineering Report No. CE-STR-86-26, Vol 2, West Lafayette, IN: School of Civil Engineering, Purdue University
3 Faella, C. and Piluso, V. and Rizzano, G.(2000). "Structural Steel Semirigid Connections", CRC Press LLC
4 Kishi, N. and Chen, W. F. and Goto, Y. and Hasan, R.(1996). "Behavior of Tall Buildings with Mixed Use of Rigid and Semi-Rigid Connections", Computer & Structures, Vol 61, No 6, pp 1193-1206   DOI   ScienceOn
5 Richard, R.M. and Gillet, P.E. and Kreigh, J.D. and Lewis, B.A.,(1980). "The Analysis and Design of Single Plate Framing Connections", AISC Engineering Journal, 2nd Quarter, pp 38-52
6 송화철, 곽영하(2001). “초대형 부유식 구조물 상부구조체의 시간이력해석", 대한건축학회 추계학술발표논문집 제21권 제2호
7 이상훈(1997). "직각 외다이아프램 형식을 이용한 각형 강관 접합부 해석을 위한 실험적 연구", 서울대학교 석사학위논문
8 채용수, 최성모, 김동규(2001). "직각판 외다이아프램형식 각형강관기둥-H형강보 반강접접합부를 가진 골조의 탄소성 거동에 관한 해석적 연구", 대한건축학회 논문집(구조계), Vol 17, No 10   과학기술학회마을