• Title/Summary/Keyword: 수평부재

Search Result 191, Processing Time 0.023 seconds

Finite Element Analysis of the Reinforced Concrete Boundary-Beam-Wall System Subjected to Axial Load (축하중이 작용하는 RC 경계보-벽체 시스템의 해석적 평가)

  • Son, Hong-Jun;Kim, Seung-Il;Kim, Dae-Jin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.2
    • /
    • pp.93-100
    • /
    • 2021
  • In Korea, one of the most used structural systems for residential apartment buildings is the combination of the reinforced concrete (RC) wall and rahmen structures in the upper and lower floors, respectively. To alleviate the significant difference between the stiffnesses of these two structural systems, large transfer girders are generally required in the transition zone of the structure, which then results in the use of large amounts of construction materials and low economic feasibility. This paper proposes a new RC boundary-beam-wall system that can minimize the disadvantages of the RC transfer girder system. The structural performance of the proposed system subjected to axial loading was evaluated via rigorous three-dimensional nonlinear finite element analysis. Four parameters, namely the ratio of lower wall to upper wall lengths, distance between stirrups, main bar slope ratio, and slab length, were considered in the finite element analysis, and their effects on the maximum axial load were analyzed and discussed.

Analysis on Long Term Behavior in 120-Story High-Rise Buildings according to Lateral-Load-Resisting Systems (120층 규모 초고층 건물에 대한 횡력저항시스템 적용에 따른 장기거동 분석)

  • Kim, Gyeong-Chan;Kim, Jae-Yo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.2
    • /
    • pp.119-129
    • /
    • 2022
  • It is essential to control the lateral displacement and differential axial shortening of the vertical elements in high-rise buildings. The differential axial shortening can cause challenges in the serviceability and safety of non-structural and structural elements, respectively. Hence, in this study, the differential axial shortening of the vertical elements and effects of long term behaviors of concrete are analyzed in 120-story high-rise buildings via the construction sequence analysis. Consequently, the axial shortening of the vertical elements is classified into elastic, creep, and shrinkage shortening, and dominant factors to the maximum axial shortening are analyzed. In addition, the serviceability of the non -structural elements is checked with a differential axial shortening at 30 years after completion of construction, and member forces at design and construction stages in girders and outrigger walls are compared.

Evaluation of Static Strength of Mixed Stud Shear Connection in Double Composite Bridges (이중합성 교량의 복합스터드 전단연결부의 정적강도 평가)

  • Kim, Hyun Ho;Shim, Chang Su;Yun, Kwang Jung;Lee, Pil Goo
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.5 s.78
    • /
    • pp.549-559
    • /
    • 2005
  • A railway bridge with a double composite section is proposed to enhance the structural performance of existing two-girder bridges because the governing design parameter of railway bridges is the flexural stiffness. The concrete deck in negative moment regions is neglected in the design of continuous composite bridges assuming the concrete slab has no resistance to tension. Therefore, the flexural stiffness of the composite section in the negative moment region is reduced resulting in the increase of the depth of the steel section. In order to resolve this disadvantage, several methods are suggested and the double composite section is one of the excellent solutions for extending the span length and increasing the flexural stiffness. In this study, push-out tests on lying studs and mixed stud shear connection with lying and vertical studs were performed to investigate the behavior of the shear connection in the double composite section. Static strength of the shear connection was evaluated through the test results and numerical analyses.

Shear Performance of Post and Beam Construction by Pre-Cut Process (프리컷 방식을 적용한 기둥-보 공법의 수평전단내력)

  • Hwang, Kweonhwan;Park, Joo-Saeng;Park, Moon-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.1-12
    • /
    • 2007
  • For the purpose of effective utilization of domestic second-grown larch as structural members, post and beam construction applying traditional construction to Japanese larch glulam members was adopted with processing by machine pre-cut method. In general, horizontal shear test by KS F 2154 is conducted to assess the horizontal shear properties of the wooden structure by post and beam construction. The frame was consisted of post and beam member with appropriate fasteners, and members have their own processed parts (notch, hole, etc.) that can be well-connected each other. The shear wall was consisted of the frame with screw-nail sheathed panel (OSB). The results of horizontal shear loading tests without vertical loads conducted on the frame and the shear wall structures, the maximum strengths were about 1.9 kN/m and about 9.7 kN/m, the shear rigidities were about 167 kN/rad, 8198 kN/rad, respectively. The strength proportion of the frame specimen was about 20% of the wall's and about 2% in initial stiffness. Nail failures are remarkable on the shear wall specimen with punching shears and shear failures. The shear load factor for the shear wall specimen by the method of Architectural Institute of Japan was 1.5, which was obtained by the bi-linear method. Loading method should be considered to obtain smooth load-deformation relationship. For the better shear performance of the structures, column base and post and beam connections and sheathed panel should be further examined as well.

Construction of wireless sensor network for structural health monitoring of large-scale buildings (대형 건물의 구조 건전도 모니터링을 위한 무선 센서 네트워크 구성)

  • Lee, Hong-Min;Kim, Jong-Moon;Hong, Jung-Bum;Park, Hyo-Seon
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.221-224
    • /
    • 2009
  • 최근 사회기반시설을 대상으로 900 MHz - 2.45 GHz 대역의 무선 센서 네트워크 시스템을 이용한 구조반응 모니터링 연구가 수행되고 있다. 건물의 경우 수직, 수평으로 구조 부재, 칸막이 벽, 외장재 등에 의해서 공간이 차단되어 있고, 전파 간섭의 영향이 상대적으로 크기 때문에 900 MHz - 2.4 GHz 대역의 무선 네트워크 시스템은 그 한계가 있다. 본 논문에서는 이러한 문제점을 고려하여 장애물에 대한 회절성이 뛰어나고 전파의 간섭이 상대적으로 작은 저주파 대역의 무선 라디오 주파수를 도입한다. 이로부터 특히 지진 또는 바람의 영향 등의 외부 하중에 의하여 대규모 인명 손실을 초래할 수 있는 중요도가 매우 높은 대형 건물을 대상으로 실제 적용이 가능한 무선 센서 네트워크를 구성해 보았다.

  • PDF

Considerations in the Safety Evaluation of the Lateral Structural Members Reinforced with Steel Plate or CFRP Sheet (강판 또는 탄소섬유시트 보강된 수평 구조 부재의 안전성 평가시 고려사항)

  • 강석원;박형철;오보환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.331-334
    • /
    • 2003
  • Since regulation or specification for the reinforcing method are quite ambiguous, structural design for the reinforcement can be subjectively and arbitrarily conducted. Thus, reasonable limitation and guide for the quantity of the reinforcement are required for the safe use of the structure after repair. In order to guarantee the safety of the structural member several items should be considered; reinforcing limit to avoid the brittle failure, least required strength of the existing member before reinforcement in order not to fail under the new serviceability load condition when reinforcing steel plates or CFRP sheets are harmed or subjected to fire.

  • PDF

Seismic Evaluation of Existing Buildings Based on Fuzzy Inference System (퍼지추론방식에 의한 기존시설물 내진성능평가)

  • 김남희;홍성걸;장승필
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.1-11
    • /
    • 2001
  • 내진성능평가 시스템은 구조시스템의 합리적인 분류, 적절한 평가 기준, 그리고 종합적인 평가방법을 포함하여야한다. 외국의 현행 내진성능 평가방법은 데이터의 수집과 주요 평가 항목을 위한 약산식 그리고 평가 점수를 이용하여 전문가의 판단에 근거한 평가 방법을 제시하고 있다. 본 연구는 국내 건축구조물에 예비 내진평가 방법에 중점을 두고 퍼지추론 시스템에 근거한 내진평가방법의 전형을 개발한다. 평가항목의 위계는 건무의 수직, 수평방향을 불규칙성, 비대칭성, 여용성, 그리고 건물 연한을 포함한 전체적인 특성과 부재 단계에서의 상세한 평가 항목으로 구성한다. 퍼지추론방법에 대한 기존의 연구결과를 근허가혀 이용한 내진성능 평가방법에 적절히 적용하기 위하여 4가지 주요 모듈을 설정한다. (1) 퍼지 입력 (2) 퍼지에 근거한 규칙기반 (3) 퍼지추론, 그리고 (4) 퍼지출력으로 구성된다. 더욱이 개별적인 성능 수준에 종합적인 평가지수를 끌어내기 위하여 퍼지추론방법을 적용하였다.

  • PDF

Development of Crankshaft for Marine Medium Engine by the TR Forging Method (TR 단조공법을 이용한 선박 중형엔진용 크랭크샤프트 개발)

  • 조봉환;박승희;이원재;김인호;김응성
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1995.06a
    • /
    • pp.35-46
    • /
    • 1995
  • TR 단조공법은 기존의 프레스에 특수장치를 장착하여 프레스의 수직힘과 수평함을 동시에 갖도록 하여 일체형의 크랭크샤프트를 제작하는 공법으로, 연속입자흐름의 크랭크쓰 로우를 제작할 수 있기 때문에 보다 우수한 특성의 크랭크샤프트를 제작할 수 있다. TR 단 조공법을 이용한 크랭크샤프트의 제작은 하나의 소재로 단조하여 제작하기 때문에 기존과는 다른 작업공법 및 전용장비가 필요하나 국내에서는 이러한 공법이나 설비의 부재로 인해 생 산되지 못한 제품이었다. 본 개발에서는 중형엔진용 크랭크샤프트의 국산화를 실현한 측면 에서 TR 단조공법 및 장치에 대한 소개와 본 단조공법을 적용하여 제작된 크랭크샤프트의 제반 특성평가를 수행하여 균일한 물성 및 연속입자흐름에 따른 피로강도의 향상 여부를 확 인하였다.

상하지진동을 받는 편평구형쉘의 응답해석례

  • 정명채
    • Computational Structural Engineering
    • /
    • v.10 no.1
    • /
    • pp.37-45
    • /
    • 1997
  • 대규모의 쉘 구조물 설계에서는 고정하중이 지배적이므로 구조물을 구성하는 부재단면은 거의 고정하중에 의해 결정되는 경우가 많다. 이미 보고된 정적하중에 대한 쉘의 좌굴에 관한 연구결과들이 말해주고 있듯이 구조물의 안전율이 어느정도 확보되어 있는가를 평가하는 일이 우선적으로 중요하다. 그러나 고정하중에 대한 안전율을 확보하여 설계된 쉘이 지진동을 받았을 경우 어떻게 거동할까, 어느정도의 지진동에 견딜 수 있는지를 조사하여 그 구조물의 내진성능을 파악하는 일은 설계상 반드시 필요한 일이라 생각된다. 지진응답에 관한 많은 연구들이 주로 수평지진동을 받는 구조물을 대상으로 하고 있다. 그러나 지진동은 원래가 3차원적인 것이고 따라서 직하형의 지진동을 받을 가능성도 있다. 특히 장span구조물은 상하지진동의 영향이 클 것으로 생각된다. 본 고에서는 상하지진동을 받는 단순지지된 편평쉘의 응답해석례를 소개하고자 한다.

  • PDF

Behavior of C-Shaped Beam to Square Hollow Section Column Connection in Modular Frame (모듈러 골조의 각형강관 기둥과 C형강 보 접합부의 거동 평가)

  • Lee, Sang Sup;Park, Keum Sung;Hong, Sung Yub;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.5
    • /
    • pp.471-481
    • /
    • 2015
  • Modular building is a prefabricated construction system for building where factory-produced pre-engineered modular units are delivered to site and assembled as substantial elements of a building. There are two basic kinds of modular structures. One is a load-bearing wall structure designed to transfer the load through longitudinal walls. The other is a frame structure composed of columns and beams. For frame structure, square hollow section is often used as a column member and channel as a beam member in modular unit. Lower and upper modules are fasten with bolts via a pre-installed access hole in the SHS column. However, the access holes can weaken the panel zone that would affect the behavior of beam to column connection. The 5 specimens of beam to column connections with parameters of access hole, column thickness and diaphragm were made and this paper describes the test results.