• Title/Summary/Keyword: 수축열시스템

Search Result 37, Processing Time 0.024 seconds

Development of Static Seal for a Liquid Rocket Engine (액체 로켓 엔진 스태틱 실 개발)

  • Jeon, Seong Min;Yoon, Suk-Hwan;Chung, Taegeum
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.4
    • /
    • pp.53-59
    • /
    • 2022
  • Static seals are used to seal high temperature gas and cryogenic fluid under high pressure, at interfaces between liquid rocket engine components such as combustion chamber, turbopump, gas generator, valves, etc. As thermal expansion and contraction at assembly interfaces cause undesirable leakage under cryogenic and high temperature environments, static seals applied for sealing of joint interfaces without relative motion should be designed properly. The additional function of rotation at the sealing face is also required for static seals, when the spherical flange is used for improvement of assembly at misalignment interfaces. In this study, structural analysis and leak tightness test of simulating test rig for several important interfaces are performed, to verify structural integrity of static seals.

THE EFFECT OF C-FACTOR AND VOLUME ON MICROLEAKAGE OF COMPOSITE RESIN RESTORATIONS WITH ENAMEL MARGINS (법랑질 변연으로 이루어진 복합레진 수복물의 체적과 C-factor가 미세누출에 미치는 영향)

  • Koo, Bong-Joo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.6
    • /
    • pp.452-459
    • /
    • 2006
  • Competition will usually develop between the opposing walls as the restorative resin shrinks during polymerization. Magnitude of this phenomenon may be depended upon cavity configuration and volume. The purpose of this sturdy was to evaluate the effect of cavity configuration and volume on microleakage of composite resin restoration that has margins on the enamel site only. The labial enamel of forty bovine teeth was ground using a model trimmer to expose a flat enamel surface. Four groups with cylindrical cavities were defined, according to volume and configuration factor(Depth x Diameter / C-factor) - Group I : 1.5 mm ${\times}$ 2.0 mm / 4.0, Group II : 1.5 mm ${\times}$ 6.0 mm / 2.0, Group III : 2.Omm ${\times}$ 1.72 mm / 5.62, Group IV : 2.0 mm ${\times}$ 5.23 mm / 2.54. After treating with fifth-generation one-bottle adhesive - BC Plus$^{TM}$ (Vericom, AnYang, Korea), cavities were bulk flted with microhybrid composite resin - Denfill$^{TM}$ (Vericom). Teeth were stored in distilled water for one day at room temperature and were finished and polished with Sof-Lex system. Specimens were thermocycled 500 times between 5$^{\circ}$C and 55$^{\circ}$C for 30 second at each temperature. Teeth were isolated with two layers of nail varnish except the restoration surface and 1 mm surrounding margins. Electrical conductivity (${\mu}$A) was recorded in distilled water by electrochemical method. Microleakage scores were compared and analyzed using two-way ANOVA at 95% level. The results were as follows: 1. Small cavity volume showed lower microleakage score than large one, however, there was no statistically significant difference. 2. There was no relationship between cavity configuration and microleakage. Factors of cavity configuration and volume did not affect on microleakage of resin restorations with enamel margins only.

Empirical Research on Application of ICT for Reduction of Energy Consumption of Hospital Buildings (ICT를 활용한 병원건물의 에너지 절감방안 연구)

  • Lee, Junghwan;Han, Youngdo;Kim, Dongwook
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.1
    • /
    • pp.422-430
    • /
    • 2018
  • Increase in oil prices and building energy consumption has been a great burden for Korea which has significant energy dependence on foreign energy sources. In this context, reduction of building energy consumption, which comprises 40% of total energy consumption, is a very important issue. This research therefore empirically analyzed a hospital "P" that implemented ICT-based energy consumption and cost reduction initiative. The hospital first replaced existing water absorber for heating/cooling air and boiler for heating water with water heat storage heat pump system. This was accompanied by subscribing to different electricity price plans to maximize cost reduction. Secondly, the hospital additionally applied ICT-based optimized control algorithm that considers surrounding factors (external temperature, changes in energy demand). The analysis of these mechanisms indicate that the ICT-based energy consumption and cost reduction initiative for hospitals can reduce energy consumption by 53.6% with replacement of low-efficiency equipment and additionally by 18.2% with optimized control algorithm. The mechanisms will provide energy consumption reduction opportunities for other hospitals and buildings with high energy consumption.

Preparation of Chemical and Fouling Resistant Semicrystalline Membranes (내식성, 내오염성 결정성 고분자 분리막의 제조)

  • 유종범;송기국;김성수
    • Polymer(Korea)
    • /
    • v.24 no.3
    • /
    • pp.342-349
    • /
    • 2000
  • Hollow fiber membranes were prepared via thermally-induced phase separation process followed by stretching process from isotactic polypropylene and soybean oil system. Various operating parameters were examined in terms of their effects on the structure variation and performances of the membrane, and were optimized. Melt viscosity of the melt sample had influence on the formation of the microfibrils, and addition of nucleating agent increased the nucleation density to enhance the interspherulitic pore formation by stretching. Annealing the membrane at its stretched state relaxed the stress induced by stretching and helped the membrane maintain the stretched structure without shrinking. Solid-liquid Phase separation is more prevalent when the nucleating agent was added, and coagulation bath temperature determined the nucleation density, which affected the pore formation by stretching. In the absence of nucleating agent, nucleation was not effective and liquid-liquid phase separation governed the structure formation, which showed the opposite trend to that of the case with nucleating agent.

  • PDF

Structures and Double Layer Performances of Carbons Pyrolized from Carbon Oxides (산화탄소로부터 열분해한 탄소의 구조 및 전기이중층 거동)

  • Kim, Ick-Jun;Yang, Sunhye;Jeon, Min-Je;Moon, Seong-In;Kim, Hyun-Soo;An, Kye-Hyeok
    • Applied Chemistry for Engineering
    • /
    • v.18 no.5
    • /
    • pp.522-526
    • /
    • 2007
  • Structural features and electrochemical performances of cokes pyrolized from oxidized cokes were examined, and compared with KOH-activated coke. Needle cokes ($d_{002}=3.5{\AA} $), having a graphene layer structure, were changed to a single phase of graphite oxide after oxidation treatment with an acidic solution having an $NaCLO_3$/needle coke composition ratio of above 7.5, and the inter-layer distance of the oxidized coke was expanded to $6.9{\AA} $ with increasing oxygen content. After heating at $200^{\circ}C$, the oxidized coke was pyrolized to the graphene layer structure with inter-layer distance of $3.6{\AA} $. However, the change of the inter-layer distance of the needle coke was not observed in the KOH activation process. On the other hand, an intercalation of electrolyte ions into the pyrolized coke, observed at first charge, occurred at 1.0 V, in which the value was lower than that of KOH-activation coke. The cell capacitor using pyrolized coke exhibited a lower internal resistance of $0.57{\Omega}$ in 1 kHz, and a larger capacitance per weight and volume of 30.3 F/g and 26.9 F/ml at the two-electrode system in the potential range 0~2.5 V than those of the cell capacitor using KOH-activation of coke. This better electrochemical performance may be associated with structure defects in the graphene layer derived from the process of the inter-layer expansion and shrinkage.

A Study on Characteristics of Polymer Organic Hard Mask Synthesis (고분자 유기하드마스크 합성에 따른 특성에 관한 연구)

  • Woo-Sik Lee
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.5
    • /
    • pp.217-222
    • /
    • 2023
  • The purpose of this paper was to synthesize a polymer organic hard mask that simplifies the manufacturing process, reduces process time significantly, and thereby lowers manufacturing costs. The results of measuring residual metals through vapor refining showed that 9-Naphthalen-1-ylcarbazole(9-NC) measured 101.75ppb in the 4th zone, 2-Naphthol (2-NA) measured 306.98ppb in the 5th zone, and 9-Fluorenone(9-F) measured between 129.05ppb across the 4th and 5th zones. After passing through a filtration system, the synthesized organic hard mask measured residual metals in the range of 9 to 7ppb. Additionally, the thermal analysis indicated a decrease of 2.78%, a molecular weight of 942, carbon content of 89.74%, and a yield of 72.4%. The etching rate was measured at an average of 18.22Å/s, and the coating thickness deviation was averaged at 1.19. For particle sizes below 0.2㎛ in the organic hard mask, no particles were observed. By varying the coating speed at 1,000, 1,500, and 1,800rpm and measuring the resulting coating thickness, the shrinkage rate ranged from 17.9% to 20.8%. The coating results demonstrated excellent adhesion to SiON, and it was evident that the organic hard mask was uniformly applied.

Stress Variation Characteristics of Temporary Fixed Steel Rod in FCM Bridge Construction Method (FCM 교량 가설 공법에서 임시 고정 강봉의 응력 변화 특성 )

  • Hyun-Euk Kang;Wan-Shin Park;Young-Il Jang;Sun-Woo Kim;Hyun-Do Yun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.3
    • /
    • pp.21-29
    • /
    • 2023
  • In this study, the stress characteristics of temporary fixed steel rods were analyzed in the "temporary fixing system using internal prestressing tension", which is mainly applied to the construction of superstructures by FCM. It was difficult to confirm the changes in initial tensile force in this system because the steel rod was internally connected to the pier and the PSC BOX. Therefore, measurement was performed before and after the completion of each segment using an FBG sensor to measure the change in the micro length of the steel rod. The results of the analysis showed that 75% to 90% of the maximum vertical contraction of the steel rod that occurred until the completion of the cantilever segment occurred in the fixing ~ 1segment, and the maximum loss of initial prestressing force was 39%. Such excessive loss of tension force to 1 segment means that tension is needed to improve the precision of construction during the fixation, and re-tension is needed to secure stability for conduction of cantilever segments after the completion of 1segment. In the 2 ~ last segment, the stress of the steel rod decreased gradually, and in the summer, the decrease in stress tended to partially recover due to the increase in the length of the steel rod corresponding to the increase in the vertical volume of PSC BOX. The dominant factor in the stress change in 2~ last segment in this phenomenon is judged to be the change in the length of the steel rod according to the temperature. Unlike the change in length, the relaxation was 1.2-2.7%, which was mostly offset by the opposite stress corresponding to the temperature stress. Therefore, a plan was proposed to improve the internal stress, such as adjusting the fixation time.