• Title/Summary/Keyword: 수질정화

Search Result 428, Processing Time 0.028 seconds

Development of Environmentally Favorable Porous Concrete and Water Purification Characteristics by the Pavement System (친환경 도로포장용 투수콘크리트의 제조와 이를 이용한 도로포장시스템의 수질정화특성)

  • Hong, Chong-Hyun;Kim, Moon-Hoon;Yang, Churl-Shin
    • Journal of Environmental Science International
    • /
    • v.15 no.11
    • /
    • pp.1045-1052
    • /
    • 2006
  • Stormwater pollution is a major problem in urban areas. Pollutants like heavy metals and harmful chemicals in the runoff can endanger soil and ground water, when they are not sufficiently removed doting infiltration. Strength and infiltration capacity of porous concrete are the major problems that must be considered if permeable pavement system are demanded to be used in a drive way application. In this study, a series of compacted porous concrete mixtures and the system of pavement ate tested for the physical characteristics like compressive strength, flexural strength, unit weight, porosity, water permeability, and the purification capacity of contaminated water. The test results obtained indicate that the strength and infiltration capacity of porous concrete are strongly related to its matrix proportion and compaction energy and providing adequate filter layers underneath pavement surface course is one of the most important design considerations of permeable pavement system for pollution retention purpose.

Evaluation of the Water Purification Efficiency of Waste LCD Glass Media by Using Foaming Technology (발포기술을 이용한 폐 LCD유리 여재의 수질정화능력 평가)

  • Ahn, Tae-Woong;Choi, I-Song;Oh, Jong-Min
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.4
    • /
    • pp.369-376
    • /
    • 2010
  • The purpose of this study is to reprocess Waste-LCD(Liquid Crystal Display), to widely increase specific surface-area by foaming agent in the process of reprocessing and to use as a substrate of water treatment which is increased the ability of biological treatment, as well as to control non-point source pollutants produced by surface run off during rainfall with using this substrate, and to improve water quality of public watershed as developing substrate for water treatment to be able to purify second treated water which is exhausted at the wastewater treatment plant. The average removal efficiency of Waste-LCD that using the foaming technology was SS 71.2%, BOD 55.7%, COD 58.4%, T-N 29.5% and T-P was 50.3%. Almost Media, early stage showed low removal efficiency of SS and BOD. However, it became high when the microorganism adhered the Media. The variation of SS removal efficiency was high by inflow concentration of SS. The reason for the Media 4 showed high SS removal efficiency is that it has wide specific surface-area, and also it has a pore. All in all, it shows floating matter treatment ability not only inside but it also works outside of the substrate.

A Study on Constructed Wetland Ecological Park Design with Multiple-cell FWS Layout -focus on Structural Design of Sustainable Structured wetland Biotope(SSB) Park- (자유수면형 인공습지 환경·생태공원 설계 -생태적 수질정화비오톱 공원의 구조설계를 중심으로-)

  • Byeon, Wooil
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.5
    • /
    • pp.1-9
    • /
    • 2006
  • The purpose of this study is to make a design guideline in designing constructed wetland which can treat water quality both of point and nonpoint source water pollution. It focuses on structural aspects of two case studies of constructed wetland applying SSB(Sustainable Structured wetland Biotope) system in Korea. The constructed wetland of Lake Ju-am which was constructed in 2002 by Environmental Management Corporation, was designed by applying SSB system. It shows higher removal efficiency than expected - 56% of BOD removal efficiency, 60% of T-N removal, and 76% of T-P removal efficiency. In two cases, total wetland areal extents were calculated referred to treatment efficiency. The system is consist of micro-cell structures : inflow channel, forebay, multiple wetland cells and micro-pool. When designing constructed wetland appropriate in local area, the total organic system of vertical and horizontal structure : geology, hydrology, land use, and ecological surroundings of the sites should be considered totally.

Ar 및 He기체유입에 따른 저온 대기압 DBD플라즈마에 의한 E.Coli의 노출 효과

  • Lee, Sang-Hak;Baek, Gu-Yeon;Kim, Yong-Hui;Yu, Yeong-Hyo;Choe, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.512-512
    • /
    • 2012
  • 최근 저온 대기압 플라즈마 장치의 개발로 대기 및 수질 환경, 바이오 메디컬분야로의 응용 연구가 활발히 진행되어 공기 중 플라즈마의 살균 및 정화효과에 대한 많은 결과가 발표되어 왔다. 본 연구는 면방전 구조의 DBD플라즈마 소스를 제작하여 He과 Ar 기체를 유입하여 미생물인 E.Coli의 변화를 관찰하였다. 면방전 구조의 DBD플라즈마 소스는 1.8 mm 두께의 유리기판위에 포토리소그라피 공정으로 미소전극을 형성하여 고밀도의 방전 셀을 형성하였으며 방전시 발생하는 열 효과를 제어하기 위하여 냉각장치를 제작하여 장착했다. 또한 유리기판과 포토 리소그라피 공정은 방전영역에 제한없이 다양한 크기의 소스제작이 가능하다. 셀 피치가 $400{\mu}m$이며 $cm^2$ 당 200여개의 방전 셀로 구성되어 있어서 기존 메쉬타입의 DBD플라즈마 장치에 비해 균일하게 플라즈마를 조사할 수 있으며 플라즈마 제트 장치에 비해서는 넓은 면적을 동시에 조사할 수 있게 되었다. Ar 과 He기체를 3 L/min의 유량으로 방전공간에 유입하면서 1kV의 구동전압으로 플라즈마를 발생 하였으며, 플라즈마의 조사시간을 20 s, 40 s, 60 s 간격으로 변화를 주어 E.Coli의 변화를 관찰하였다.

  • PDF

Effectiveness Analysis of Flood Control by Wetland Constructions (습지조성을 통한 홍수조절 효과 분석)

  • Kim, Jung-Wook;Jung, Jae-Won;Choi, Young-Joo;Kim, Hung-Soo
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2016.11a
    • /
    • pp.223-225
    • /
    • 2016
  • 최근 기후변화 및 도시화의 영향으로 홍수와 가뭄과 같은 자연재난이 점점 심화되고 있다. 습지는 유속과 수위를 낮추는 홍수조절 효과가 있으며 가뭄시에는 물을 저장하는 역할을 하여, 인공습지의 조성은 심각해지는 홍수 및 가뭄에 해결방안으로 활용될 수 있다. 기존의 인공습지에 관한 연구는 식생과 수질정화기능과 종 다양성 등 생태적 기능에 관한 연구가 주로 이루어져왔으며, 인공습지의 홍수조절 효과에 관한 연구는 미비한 실정이다. 따라서, 본 연구에서는 경안천 유역에 인공습지 조성에 따른 수문학적 홍수저감효과를 분석하였다. 이를 위해 수리모형인 HEC-RAS를 통하여 가상의 인공습지를 모형화 하여 인공습지 조성 전 후에 대한 홍수위를 비교 분석하였다. 또한 홍수범람을 모의하여 대상유역의 침수심 및 침수면적을 산정하고 이를 다차원홍수피해액산정법을 통하여 인공습지 조성 전 후에 대한 홍수피해액을 추정하였다. 본 연구결과를 바탕으로 인공습지 조성 사업 시 사업의 경제적 타당성을 평가하며, 인공습지 설계의 기초자료로 활용될 수 있을 것으로 기대된다.

  • PDF

Influence of Forest Practices on Soil Physical Properties and Facility of Purifying Water Quality in Pinus rigida Stands (리기다소나무 임분에서 산림관리작업이 토양의 물리성 및 산림의 수질정화기능에 미치는 영향)

  • Park, Jae-Hyeon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.10 no.2
    • /
    • pp.61-70
    • /
    • 2007
  • This study aims to clarify the effect of forest management practices(thinning and pruning) on soil physical properties and water quality to get the fundamental information on the facility of purifying water quality after forestry practices. Rainfall, throughfall, stemflow, soil and stream water were sampled at the study site which consists of Pinus rigida in Jinju National University Experimental Forest for 4 years from Mar. 1, 2002 to Nov. 30, 2006. Averaged tree height of the management site increased by 1.6m, compared to the value of the non-management site in Pinus rigida. Increment of averaged D. B. H. at the management site showed 4.2cm more in Pinus rigida compared with that at non-management sites. Mesopore ratios (pF2.7) and total porosities of A layer soil at the management site increased more than those at the non-management sites in both stands. Otherwise, soil bulk density resulted in being reversely. Water qualities of throughfall, stemflow and buffered soil water were influenced more positively by the management practice. The average electrical conductivity of stream water was $32.9{\mu}S/cm$ within the range of non-polluted stream water.

Adsorption Characteristics of Altered Feldspar Porphyry for Heavy Metals (변질 장석반암의 중금속 흡착특성)

  • Park, Sang-Bum;Hwang, Jeong
    • Journal of the Korean earth science society
    • /
    • v.29 no.3
    • /
    • pp.246-254
    • /
    • 2008
  • This study has been performed to evaluate the possibility of utilizing feldspar porphyry as an adsorbent for heavy metals in natural water. The research sample rock 'Maekbansuk' was altered feldspar porphyry which included chlorite, epidote and calcite formed by a prophylitic alteration process. In extraction tests, the majority of extracted elements were Ca and Na, which were extracted in much greater abundance from the groundmass than from the feldspar phenocryst. In adsorption tests, the adsorption capacities of Pb, Fe and Cu within an hour of reaction time were 99, 98 and 97%, respectively, but that of As remained 25% for a full 24 hours. The high adsorption capacities of altered feldspar porphyry for Pb, Fe and Cu suggest its potential utilization as a heavy metal adsorbent fur water purification.

Numerical Study on Behavior of Underground Freshwater Body with Variation of Freshwater Injection in a Coastal Aquifer (염수대수층 내 담수 주입 변화에 따른 지하 담수체 거동에 대한 수치모의)

  • Jeong, Woo Chang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.249-249
    • /
    • 2015
  • ASR(Aquifer Storage Recharge) 또는 ASTR(Aquifer Storage Transfer Recharge)과 같은 직접적인 지하수 인공함양기법은 대수층을 활용하여 수자원을 공급하고 관리하기 위한 적극적인 방안으로 고려될 수 있다. 이 중 ASTR 기법은 대규모 충적층이 발달한 강변 또는 하구에서 저류지 수생식물의 정화작용과 층적층의 물리/화학/생물학적 여과 기능을 활용하여 양질의 상수원수를 확보할 수 있는 기법이며, 수질이 나쁜 하천수를 직접 취수하여 정수처리하는 것에 비해 정수비용이 상대적으로 적게 들어 투자대비 경제적인 상수원수 확보기술이라 할 수 있다. 본 연구에서는 하구에 염수 대수층이 위치해 있다고 가정하였으며, 이러한 염수 대수층 내에 담수 주입 변화에 따른 지하 담수체의 거동을 4가지 시나리오에 따라 모의 및 분석을 통해 조사하였다. 염수 대수층 내에서 8개의 주입정과 1개의 양수정이 설치되어 있다고 가정하였으며, 주입정은 동심원 상에 등간격으로 위치해 있으며, 양수정은 동심원 중에 위치해 있다고 가정하였다. 본 연구에서 구성된 시나리오로 첫 번째는 주입정 8개 모두에서 동시에 주입되며, 1개의 양수정을 통해 양수되는 것이며, 두 번째는 7개의 주입정에 주입 그리고 1개의 주입정 폐쇄, 세 번째는 6개 주입정에 주입 및 양수정과 서로 마주보는 2개 주입정 폐쇄, 그리고 마지막으로 6개 주입정에 주입 및 서로 이웃한 2개 주입정 폐쇄이다.

  • PDF

Removal of Heavy Metal Ions from Wastewater by Polyacrylonitrile based Fibers: A Review (폴리아크릴로나이트릴 섬유를 기반으로 한 폐수에서의 중금속 이온 제거: 총설)

  • Oh, Hyunyoung;Lee, Jae Hun;Patel, Rajkumar
    • Membrane Journal
    • /
    • v.29 no.3
    • /
    • pp.123-129
    • /
    • 2019
  • Environmental pollution caused by the presence of heavy metal ion from growing industrialization or from leaching is increasing area of concern. There are several area of water purifications but among them adsorption on the functionalized polymer fibers is efficient and cost-effective method. Polyacrylonitrile (PAN) is exciting polymer due to the presence of excessive functional group which can be easily transformed for metal ion adsorption. PAN can be easily electrospun to prepare nanofiber that have higher surface area leading to better metal ion removal. Composite PAN fiber is yet another type of polymer covered in this review for waste water treatment.

Effects of weir on the change of sediments (하천의 보가 퇴적물에 미치는 영향)

  • Cho, Yong-Chul;Kim, Kyung-Hee;Woo, Hyo-Seop;Oh, Jong-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1083-1087
    • /
    • 2006
  • 과거 50 년 동안 국내 보 설치 수는 매년 증가하여 왔으나, 그 증가비율은 근래 들어 감소하는 추세로, 이는 보 보다는 용수공급능력이 큰 양수장, 저수지 등 타 시설물에 의존하는 것으로 판단 할 수 있다. 더욱이 인구의 도시 집중화에 따른 농경지의 도시화, 경작 방식의 변화에 의한 비닐하우스 단지로의 변화, 시설의 노후화 등으로 매년 $50{\sim}150$개 정도의 보가 폐기되고 있다. 그러나 이렇게 폐기되는 보는 하천에 그대로 존치되어 하천생태통로의 단절, 수질악화, 수변 서식처 악화 등의 문제를 지속적으로 야기 시키고 있다. 실험은 문산천 검전보, 안양천 안양대교보, 기철거된 경안천 무명보에서 자연시료를 채취하여 실행 하였다. 문산천 검전보는 하천환경이 안정되고 양호한 대조구간으로 선정하였다. 안양 대교보는 도심화로 인하여 원기능을 상실하였으며 수차례에 걸친 개수가 이루어졌고 수년전까지만 해도 러브보로 인한 수질정화장치가 있었으나 효능이 약화되어 철거할 계획을 가지고 있는 것으로 알려져 있다. 경안천 무명보는 현재는 완전 철거된 상태이다. 경안천 무명보는 기 철거된 보의 대조구간으 로 선정하였다. 보 상류의 수질 오염도가 높은 것은 정체구역에 의한 용존산소 부족과 오염저니에 의한 것으로 판단되므로, 각각의 대상보의 퇴적물 오염도를 조사하였다. 각각의 조사 지점은 검전보의 경우, 만장교를 최상류 지점으로, 검전보 상/하류, 광탄교를 최하류 지점으로 선정하여, 총 4 지점에서 채취했으며, 안양대교보의 경우 최상류지점, 보 상/하류 지점으로 총 3지점, 무명보의 경우 보 상/하류로 총 2 지점에서 채취했으며, 실험은 $\ulcorner$Soil Method$\lrcorner$에 준하여, 각각 입도분포, 함수율, 강열감량, COD, T-N, T-P 등을 시행하였다. 문산천 검전보 퇴적물 오염도 조사 결과, 강열감량, COD, T-N, T-P 항목에서 보 상류가 보 하류에 비해 높게 나타났으며, 각각 하류에 비해 상류가 30.76%, 16.69%, 73.13%, 18.91% 더 높게 나타났다. 안양대교보 퇴적물 조사 결과, 검전보와 마찬가지로, 강열감량, COD, T-N, T-P 항목에서 보 상류가 보 하류에 비해 33.33%, 9.23%, 24.78%, 18.56% 높게 나타났다. 기 철거된 무명보의 경우, 무명보 상류, 무명보 하류 2개 지점을 채취하였으며, 강열감량, COD, T-N 항목에서 보 상류가 보 하류에 비해 18.75%, 412.6%, 25.75% 높게 나타났다. 퇴적물 조사 결과, 강열감량, COD, T-N 항목에서 검전보, 안양대교보, 무명보 모두 보 상류의 오염도가 높게 나타났으며, 무명보를 제외한 검전보, 안양대교보는 T-P 항목에서도 보 상류의 오염도가 높게 나타나, 보 상류의 퇴적물 오염농도가 심화된 것으로 나타났다. 그러나 기철거된 무명보의 경우, 강열감량, COD, T-N, 항목에서 보 상류가 높게 나타났으나, 철거되지 않은 검전보나 안양대교보에 비해 그 차이가 크지 않은 것으로 나타났다.

  • PDF