Computer Simulation on the Performance of Air-Cooled Condenser for an Absorption Heat Pump (흡수식 열펌프용 공냉식 응축기의 성능특성에 관한 시뮬레이션)

  • 박윤철;민만기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.8
    • /
    • pp.1999-2011
    • /
    • 1995
  • Computer simulation was conducted to study performance characteristics of air-cooled condenser of a double effect absorption heat pump with variations of saturation pressures and mass flow rates of the refrigerant ; volume flow rates, relative humidities and temperatures of the air The vertically installed condenser had the staggered tube array with continuous plate fins of wavy type. When the saturation pressure of the condenser was decreased from 760 torr to 20 torr, heat transfer rates and condensing rates of refrigerant were decreased. If excess refrigerant flows in the condenser, the pressure and saturation temperature of the condenser were increased which makes the refrigerating capacity of an absorption heat pump reduced.

Hybrid telescopic double crown denture on maxillary few remaining teeth and 2 mandibular implants in case of failed implant overdenture (상악의 소수 잔존치와 실패한 하악의 임플란트 오버덴처의 재수복 임상증례: 프릭션핀을 이용한 하이브리드 텔레스코픽 이중관법)

  • Ha, Seok-Joon;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.246-252
    • /
    • 2016
  • Double crown prostheses can be used in patients who have a few remaining teeth and poor periodontal condition because of secondary splinting of abutments, vertical loading, decrease of the length of lever arm due to fulcrum line located on margin of inner and outer crown. Successful results of treatments using double crown prostheses for the partially edentulous patients who have a few remaining teeth and implant overdenture using a small number of implants have been reported. In this case, there were a few remaining teeth with a very poor periodontal condition in maxilla, and there were a failed implant with severe alveolar bone resorption and shrinkage in the mandible. The main objective of this report is to introduce our case because a double crown partial denture showed satisfactory results in functional and esthetical aspects during more than one-year follow-up period.

The Properties of Microwave Propagation in Discharging Plasma (방전에 의한 프라즈마에서의 마이크로파 전파특성)

  • Yang, In-Eung;No, Bang-Hyeon;Kim, Bong-Yeol
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.5 no.3
    • /
    • pp.31-39
    • /
    • 1968
  • In this paper microwave power propagated through the cold plasma was analyzed and measured with respect to the external magenetic flux density. The d. c discharge plasma was in the rectangular waveguide in which two electrode was inserted, and also the glass diseharge tube inserted in the ractangular wavegside. The direction of microwave pro-pagation, the axis of the discharge tube and external magnetic flux were perpendicular to each other. It showed that the attenuation and absorption of micro wave power propagated in the plasma was increased as the magnetic flux density, the discharge current and the pressure of the gas were increased.

  • PDF

Determination of the Size of Surge Tank with Partition (격벽을 갖는 조압수조의 크기 결정)

  • Kim, Kyoung Ho;Yang, Hai Ryong;Oh, Hyun Sik;Lee, Ho Jin
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.159-159
    • /
    • 2011
  • 수자원 공급의 시 공간적 편차가 큰 우리나라에서는 수자원을 이용하기 위해서 다수의 댐을 건설하고 있다. 특히, 생활수준의 향상으로 용수 수요가 급증하였기 때문에 용수가 부족한 곳에는 광역상수도 사업 등을 통하여 용수를 공급하고 있다. 댐에서 용수가 공급되기까지의 과정은 일종의 관수로 흐름으로 생각할 수 있다. 관수로 내를 흐르는 유체가 갑자기 정지하게 되면, 유체 운동 에너지의 변화가 유발되고, 그로 인해 관내에 급격한 압력의 상승이 일어나게 된다. 반대로 정지하고 있던 유체가 빠른 속도로 흐르게 되면 압력 감소가 급격하게 발생한다. 이와 같이 유체 운동 상태의 급변에 의한 압력변화와 그에 따른 압력파가 음속의 속도로 상 하류로 전파되는 현상을 수격작용(waterhammer)이라 한다. 통상적으로 수격작용은 밸브 개폐 정도가 갑자기 바뀔 때, 펌프의 급격한 기동이나 정지 시, 터빈 내 전력소요가 갑자기 바뀔 때, 댐 수위의 갑작스런 변화, 펌프 임펠러의 진동, 물 수요의 급격한 변화 등에 의해 발생하며, 수격작용은 유체의 질량과 운동량 때문에 관 벽에 큰 힘을 가하게 되어 정상적인 동수압 보다 몇 배나 큰 압력을 발생시킴으로 관 자체는 물론 펌프, 밸브, 터빈 등 관 시설물을 파손시키거나 진동, 소음 등을 야기시킴으로 대규모 건물, 공장, 발전소 등을 설계할 경우 그에 대한 적절한 대책을 강구하여야 한다. 특히 댐에 연결된 저수지 또는 조정지로부터의 도수로가 압력수로이며 그 길이가 상당히 크면 수차가 급정지했을 경우 수격작용에 의해서 압력터널 내에 과도한 압력상승이 일어난다. 이 압력상승을 방지함과 함께 발전소 부하의 증감에 따라서 수량을 공급하거나, 흡수할 목적으로 압력도수로와 수압관과의 접합부에 자유수면이 있는 수조를 설치한다. 이것을 조압수조(surge tank)라 한다(최영박, 1979). 조압수조에서 부하의 급속한 차단에 의해서 수차로 유입될 수량이 차단되면 도수로 내로 흘러 들어온 물은 관성 때문에 수조 내의 수위를 상승시키고, 수조 수위가 어느 정도 이상으로 되어 저수지 수위 보다 상승하면 수조로의 유입이 정지하고 반대로 수조에서 저수지로 역류하여 수조수위는 하강한다. 즉, 조압수조는 도수로 내에 발생한 과도한 압력을 수조 내 수면의 승강운동을 이용하여 감소시키고 원래의 안정적인 수위로 회복시킨다. 본 연구에서는 수격작용에 대한 댐 안정성을 확보하는 수단 중의 하나인 조압수조에 대해 살펴보았다. 연구대상으로 용담댐을 선정하였다. 용담댐에 대한 기존의 검토결과 수직 갱의 지름이 5m 이상이면 조압수조의 동적안정조건을 만족 시키는 것으로 조사되었다. 댐의 설계홍수위인 EL. 265.5m를 기준으로 조압수조의 안정성을 감소시키지 않는 범위 내에서 조압수조 내 격벽 설치 유 무에 따른 수조의 최적 크기를 산정하였다. 산정결과를 분석한 결과 동일 조건에서 격벽을 설치한 경우가 격벽을 설치하지 않은 경우에 비해서 조압수조의 면적이 약 21% 감소하는 것으로 나타났다.

  • PDF

Comparison of Solid Circulation Characteristics with Change of Lower Loop Seal Geometry in a Circulating Fluidized Bed (순환유동층에서 하부 루프실 형태 변화에 따른 고체순환 특성 비교)

  • Lee, Dong-Ho;Jo, Sung-Ho;Jin, Gyoung-Tae;Yi, Chang-Keun;Ryu, Ho-Jung;Park, Seung Bin
    • Korean Chemical Engineering Research
    • /
    • v.52 no.4
    • /
    • pp.522-529
    • /
    • 2014
  • Circulating fluidized bed system consists of SEWGS reactor - lower loop seal - regeneration reactor - riser - cyclone - upper loop seal has been used for solid circulation between the SEWGS reactor and the regeneration reactor in a SEWGS system for pre-combustion $CO_2$ capture. A vertical type lower loop seal has been used in current system but this lower loop seal requires high gas flow rate through the lower loop seal for fluidization and smooth solid circulation, and consequently, causes slugging behavior sometimes. To overcome these disadvantages, inclined type lower loop seal was proposed by this study. Solid circulation characteristics with change of lower loop seal geometry were measured and compared in a bubbling - bubbling - riser type circulating fluidized bed using $CO_2$ absorbent (P-78) as bed material at ambient temperature and pressure. We could conclude that the inclined lower loop seal is better than the vertical type lower loop seal from the viewpoints of minimum flow rate requirement for stable solid circulation and solid height change during solid circulation.

A Numerical Model of Three-dimensional Soil Water Distribution for Drip Irrigation Management under Cropped Conditions (작물 흡수를 고려한 3차원 토양수분 분포 모델 개발을 통한 최적 점적 관개 연구)

  • Kwon, Jae-Phil;Kim, Seung-Hyun;Yoo, Sun-Ho;Ro, Hee-Myong
    • Applied Biological Chemistry
    • /
    • v.43 no.2
    • /
    • pp.116-123
    • /
    • 2000
  • A numerical model of three-dimensional soil water distribution for drip irrigation management under cropped conditions was developed using Richards equation in Cartesian coordinates. The model accounts for both seasonal and diurnal changes in evaporation and transpiration, and the growth of plant root and the shape of root zone. Solutions were numerically approximated using the Crank-Nicolson implicit finite difference technique on the block-centered grid system and the Gauss-Seidel elimination in tandem. The model was tested under several conditions to allow the flow rates and configurations of drip emitters vary. In general, simulation results agreed well with experimental results and were as follows. The velocity of soil-water flow decreased drastically with distance from the drip source, and the rate of expansion of the wetted zone decreased rapidly during irrigation. The wetting front of wetted zone from a surface drip emitter traveled farther in vertical direction than in horizontal direction. Under this experimental weather condition, water use efficiency of a drip-irrigated apple field was greatest for 4-drip-emitter system buried at 25 cm, resulting from 10% increase in transpiration but 20% reduction in soil evaporation compared to those for surface 1-drip emitter system. Soil moisture retention curve obtained using disk tension infiltrometer showed significant difference from the curve obtained with pressure plate extractor.

  • PDF

Full mouth rehabilitation of the patient with crossed occlusion using implant fixed prosthesis: A case report (엇갈린 교합 환자에서 임플란트 고정성 보철물을 이용한 수복증례)

  • Jung, Byung-Suk;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.338-346
    • /
    • 2018
  • Crossed occlusion can be treated either by overdenture and telescopic denture or by placing an implant at the edentulous area to reestablish the support on the occlusion. If alveolar bony support is sufficient and an the environment where an implant is inserted is favorable to restoring the masticatory and aesthetic function of a patient, the implant-supported fixed prosthesis can provide more definitive occlusal support and more aid for other oral functions. In this case report, a patient with a severe residual alveolar bone resorption following the extraction of teeth and who had a crossed occlusion was treated with sinus bone graft and alveolar bone augmentation in order to place the implants at prosthetically position. The definitive restoration was made to reflect the patient's occlusal and aesthetic function using the CAD/CAM double scanning method. Finally, the treatment had the masticatory and aesthetic function adequately restored, which is reported here.

Studies on the Characteristics of Phosphorus in the Upland Soil -II. Relation of Soil Phosphorus and Some Soil Chemical Properties (경작지(耕作地) 전토양(田土壤)의 인산특성(燐酸特性)에 관(關)한 연구(硏究) -II. 토양(土壤) 인산함량(燐酸含量)과 몇가지 토양(土壤) 화학성(化學性)과의 관계(關係))

  • Shin, Cheol-Woo;Kim, Jeong-Je
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.21 no.2
    • /
    • pp.195-201
    • /
    • 1988
  • A laboratory experiment was coducted to investigate the relation of various soil phosphorus and some soil chemical properties which affect the composition of inoganic phosphorus and soil phosphorus with 149 phosphorus accumulated soil samples. Soil pH and exchangeable Ca were showed positively high significant correlation with 1.25 $N-NH_4$ OAc-P, Saloid-P, Ca-P and Total-P, however the soil pH was not showed significant relationship with $0.01M-CaCl_2-P$, Al-P, and Fe-P, respectively. Active Al and available phosphorus, water soluble P, and inoganic phosphorus were showed negatively high significant correlation, but Al-P and Fe-P were not. Also active Fe were showed positively significant correlation at 1% level for Fe-P and total-P. In the relationahips between soil pH and active Al, and exchangeable Ca, active Al were showed negatively high significant correlation with log regression equation, and exchangeable Ca were showed positively high significant correlation with liner regression equation. P sorbed by soil from p 20ppm solution was showed negatively high significant correlation with available phosphorus, water soluble P and $0.01M-CaCl_2-P$ in soil and positively with active Al, but was not significant with Ca-P.

  • PDF

TECHNICAL STUDY ON THE CONTROLLING MECHANIQUES OF THE ENVIRONMENTAL FACTORS IN THE MUSHROOM GROWING HOUSE IN CHONNAM PROVINCE (전남지방(全南地方)에 있어서의 양송이 재배(栽培)에 최적(最適)한 환경조건(環境條件) 조절법분석(調節法分析)에 관(關)한 연구(硏究))

  • Lee, Eun Chol
    • Journal of Korean Society of Forest Science
    • /
    • v.9 no.1
    • /
    • pp.1-44
    • /
    • 1969
  • The important results which have been obtained in the investigation can be recapitulated as follows. 1. As demostrated by the experimental results and analyses concerning their effects in the on-ground type mushroom house, the constructions in relation to the side wall and ceiling of the experimental houses showed a sufficient heat insulation on effect to protect insides of the houses from outside climatic conditions. 2. As the effect on the solar type experimental mushroom house which was constructed in a half basement has been shown by the experimental results and analyses, it has been proved to be effective for making use of solar heat. However there were found two problems to be improved for putting solar houses to practical use in the farm mushroom growing: (1) the construction of the roof and ceiling should be the same as for the on-ground type house, and (2) the solar heat generating system should be reconstructed properly. A trial solar heat generating system is shown in Fig. 40. 3. Among several ventilation systems which have been studied in the experiments, the underground earthen pipe and ceiling ventilation, and vertical side wall and ceiling ventilation systems have been proved to be most effective for natural ventilation. 4. The experimental results have shown that ventilation systems such as the vertical side wall and underground ventilation systems are suitable to put to practical use as natural ventilation systems for farm mushroom houses. These ventilation systems can remarkably improve the temperature of fresh air which is introduced into the house by heat transfers within the ventilation passages, so as to approach to the desired temperature of the house without any cooling or heating operation. For example, if it is assuming that x is the outside temperature and y is the amount of temperature adjustment made by the influence of the ventilation system, the relationships that exist between x and y can be expressed by the following regression lines. Underground iron pipe ventilation system ${\cdots}{\cdots}$ y=0.9x-12.8 Underground earthen pipe ventilation system ${\cdots}{\cdots}$y=0.96x-15.11 Vertical side wall ventilation system${\cdots}{\cdots}$ y=0.94x-17.57 5. The experimental results have shown that the relationships existing between the admitted and expelled air and the $Co_2$ concentration can be described with experimental regression lines or an exponent equation as follows: 1) If it is assumed that x is an air speed cm/sec. and y is an expelled air speed in cm/sec. in a natural ventilation system, since the y is a function of the x, the relationships that exist between x and y can be expressed by the regression lines shown below: 2) If it is assumed that x is an admitted volume of air in $m^3/hr$ and y is an expelled volume of air in $m^3/hr$ in a natural ventilation system, since the y is a function of the x, the relationships that exist between x and y can be expressed by the regression lines shown below. 3) If it is assumed that the expelled air speed in cm/sec and replacement air speed in cm/sec. at the bed surface in a natural ventilation system are shown as x and y, respectively, since the y is a function of the x, the relationships that exist between x and y can be expressed by the following regression line: G.E. (100%)- C.V. (50%) ventilation system${\cdots}$ y=0.54X+0.84 4) If it is assumed that the replacement air speed in cm/sec. at the bed surface is shown as x, and $CO_2$ concentration which is expressed by multiplying 1000 times the actual value of $CO_2$ % is shown as y, in a natural ventilation system, since the y is a function of the x the relationships that exist between x and y can be expressed by the following regression line: G.E. (100%)- C.V. (50%) ventilation system${\cdots}{\cdots}$ y=114.53-6.42x 5) If it is assumed that the expelled volume of air is shown as x and the $CO_2$ concentration which is expressed by multiplying 1000 times the actual of $CO_2$ % is shown as y in a natural ventilation system, since the y is a function of of the x, the relationships that exist between x and y can be expressed by the following exponent equation: G.E. (100%)-C.V. (50%) ventilation system${\cdots}{\cdots}$ $$y=127.18{\times}1.0093^{-X}$$ 6. The experimental results have shown that the ratios of the crass sectional area of the G.E. and C.V. vent to the total cubic capacity of the house, required for providing an adequate amount of air in a natural ventilation system, can be estimated as follows: G.E. (admitting vent of the underground ventilation)${\cdots}{\cdots}$ 0.30-0.5% (controllable) C.V. (expelling vent of the ceiling ventilation)${\cdots}{\cdots}$ 0.8-1.0% (controllable) 7. Among several heating devices which were studied in the experiments, the hot-water boilor which was modified to be fitted both as hot-water toiler and as a pressureless steam-water was found most suitable for farm mushroom growing.

  • PDF