• Title/Summary/Keyword: 수직이상점

Search Result 160, Processing Time 0.03 seconds

DECISION OF PROPER PROJECTION ANGLE AND EVALUATION OF REPRODUCIBILITY IN TRANSCRANIAL RADIOGRAPH (악관절규격촬영시 적절한 입사각의 결정 및 재현성의 평가)

  • Ryu Jung-Soo;Choi Soon-Chul;Lee Sang-Han
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.1
    • /
    • pp.99-107
    • /
    • 1991
  • The purpose of this study was to decide the proper projection angle that could avoid the superimposition of the petrous portion of temporal bone and posterior clinoid process in cephalometric lateral and basal view of the 10 dry skulls and to analyze the reproducibility of a modified Accurad-100 head holder device from Denar Co. and a cephalostat head holder in 30 transcranial radiographs of the dry skull. The results were obtained as follows: The vertical angle was 24.5±4.1° and the horizontal angle was 3.0 ±5.7°. The distances between arbitrary 3 points which were on the TMJ area were as follows: AB 16.76±0.27㎜, BC 8.79±0.18㎜ in the transcranial radiographs using modified Accurad-100 head holder, AB 29.03±0.14㎜, AC 19.95±0.24㎜, BC 10.08±0.07㎜ in the transcranial radiographs using cephalostat.

  • PDF

Time-Domain Solutions of the VV, HV, VH Problems at the Surface of a Normally Uniaxial Half-Space Dielectric (수직 단축성을 갖는 반공간 유전체 표면에서 VV, HV, VH 문제의 시간영역 해)

  • Lihh Won-Seok;Nam Sang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.12 s.103
    • /
    • pp.1246-1254
    • /
    • 2005
  • Theoretical investigation is made on the electromagnetic fields generated by an impulsive point current source, fur the VV, HV, and VH problems at the interface between an isotropic upper half-space medium and a normally uniaxial lower half-space medium. The electric fields of these problems are associated only with the extraordinary-wave components in the Fourier-Laplace domain. Applying the Cagniard-de Hoop method to each problem, the time-domain solutions of the wave fields are obtained. The fields of the VV case can be expressed in explicit(integral-free) forms. The fields of the HV and VH cases are not integral-free, but the major singularities implicit in the integral solutions can be analytically extracted. The interfacial far fields in the frequency domain are determined by the singularities in the time domain.

Treatment of Severely Worn Dentition: A Clinical Report (심하게 마모된 치열의 보철수복)

  • Choi, Mee-ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.337-347
    • /
    • 2009
  • The treatment of a patient with severely worn dentition is often challenging due to loss of vertical dimension and an uneven occlusal plane. To establish a correct occlusal plane and space for prostheses, it is necessary to increase vertical dimension. Occlusal vertical dimension is the vertical position of mandible to maxilla in centric occlusion. McAndrew reported that in spite of the change of the vertical dimension, the altered occlusion would be maintained if the equal occlusal contacts were established in centric relation. Centric relation is defined as an anatomically and physiologically stable, repeatable posture of the mandible and can be considered a most acceptable treatment and reference position. In this case we tried to treat patients with severely worn dentition by the use of centric relation and increased vertical dimension for the space of prostheses.

유연성 투명전도막의 전기적 특성에 미치는 CNT 길이의 영향

  • Sin, Ui-Cheol;Jeong, Gu-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.456-456
    • /
    • 2011
  • 최근 차세대 디스플레이, 터치스크린, 전자파 차폐 및 흡수 등의 다양한 응용분야에 적합한 소재를 개발하기 위한 연구가 진행되고 있다. 현재 주로 사용되는 ITO박막은 희소원소인 인듐의 매장량 한계와 높은 비용이 문제시 되고 있기 때문에, 대체 재료의 개발이 시급하게 요구되고 있다. 탄소나노튜브(CNT)는 금속을 능가하는 이론적인 전기전도도를 갖고 있으며 높은 탄성등의 우수한 기계적 성질을 갖고 있어 다양한 차세대 응용에 있어서 최적의 재료로 주목을 받고 있다. 특히, CNT 기반의 투명전도막은 기존의 ITO 박막 보다 우수한 유연성이 기대되어 더욱 기대를 모으고 있다. 본 연구에서는, 최종 고순도 재료를 얻기까지 합성 및 정제에 많은 공정과 시간이 요구되는 고가의 단층벽 나노튜브(SWNT)를 이용하지 않고, 웨이퍼 기판 위에 수직배향 합성한 상태의 다층벽 나노튜브(MWNT)를 별도의 정제과정 없이 초음파 분산한 뒤, 스프레이 코팅법을 이용하여 고분자 기판 위에 투명전도막을 제작하였고, 이때 각기 다른 길이의 수직배향 MWNT를 이용하여 유연성 투명전도막의 전기적 특성에 미치는 MWNT 길이의 영향에 대해 알아보았다. MWNT는 아세틸렌가스를 이용하여 열CVD법으로 합성하였고, 합성시간을 제어함으로써 길이가 다른 MWNT를 얻을 수 있었다. 투명전도막 제조공정의 단순화를 위하여 이용한 MWNT의 초음파 분산 결과, $500{\mu}m$ 이하 길이의 MWNT에서 분산성이 현저히 빨라지는 것을 확인하였다. 한편, 제작한 MWNT 기반의 유연성 투명전도막은 원자간힘현미경 및 면저항 측정기를 이용하여 막 두께에 따른 면저항 특성을 조사하였다. 그 결과 응용 가능한 면저항을 갖는 MWNT 투명전도막의 두께는 최소 50 nm 이상이어야 함을 알았고, 특히 MWNT등의 접촉점(node) 수에 따른 접촉저항 및 전기전도경로(electric conductivity path)를 고려했을 때 최적의 MWNT 길이가 존재하는 것을 확인하였다.

  • PDF

Morphological and Photoluminescence Characteristics of Laterally Self-aligned InGaAs/GaAs Quantum-dot Structures (수평 자기정렬 InGaAs/GaAs 양자점의 형태 및 분광 특성 연구)

  • Kim J. O.;Choe J. W.;Lee S. J.;Noh S. K.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.1
    • /
    • pp.81-88
    • /
    • 2006
  • Laterally self-aligned InGaAs/GaAs quantum-dots (QDs) have been fabricated by using a multilayer stacking technique. For the growth optimization, we vary the number of stacks and the growth temperature in the ranges of 1-15 periods and $500-540^{\circ}C$. respectively, Atomic force microscope (AFM) images and photoluminescence (PL) spectra reveal that the lateral alignment of QDs is enhanced in extended length by an increased stack period, but severely degrades into film-like wires above a critical growth temperature. The morphological and the photoluminescence characteristics of laterally self-aligned InGaAs QDs have been analyzed through mutual comparisons among four samples with different parameters. An anisotropic arrangement develops with increasing number of stacks, and high-temperature capping allows isolated QDs to be spontaneously organized into a one-dimensionally aligned chain-like shape over a few ${\mu}m$, Moreover, the migration time allowed by growth interruption plays an additional important role in the chain arrangement of QDs. The QD chains capped at high temperature exhibit blue shifts in the emission energy, which may be attributed to a slight outdiffusion of In from the InGaAs QDs.

Evaluation of Set-up Accuracy for Frame-based and Frameless Lung Stereotactic Body Radiation Therapy (폐암 정위체부방사선치료 시 고정기구(frame) 사용 유무에 따른 셋업 정확성 평가)

  • Ji, Yunseo;Chang, Kyung Hwan;Cho, Byungchul;Kwak, Jungwon;Song, Si Yeol;Choi, Eun Kyung;Lee, Sang-wook
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.286-293
    • /
    • 2015
  • The purpose of this study was to evaluate the set up accuracy using stereotactic body frame and frameless immobilizer for lung stereotactic body radiation therapy (SBRT). For total 40 lung cancer patients treated by SBRT, 20 patients using stereotactic body frame and other 20 patients using frameless immobilizer were separately enrolled in each group. The setup errors of each group depending on the immobilization methods were compared and analyzed. All patients received the dose of 48~60 Gy for 4 or 5 fractions. Before each treatment, a patient was first localized to the treatment isocenter using room lasers, and further aligned with a series of image guidance procedures; orthogonal kV radiographs, cone-beam CT, orthogonal fluoroscopy. The couch shifts during these procedures were recorded and analyzed for systematic and random errors of each group. Student t-test was performed to evaluate significant difference depending on the immobilization methods. The setup reproducibility was further analyzed using F-test with the random errors excluding the systematic setup errors. In addition, the ITV-PTV margin for each group was calculated. The setup errors for SBF were $0.05{\pm}0.25cm$ in vertical direction, $0.20{\pm}0.38cm$ in longitudinal direction, and $0.02{\pm}0.30cm$ in lateral direction, respectively. However the setup errors for frameless immobilizer showed a significant increase of $-0.24{\pm}0.25cm$ in vertical direction while similar results of $0.06{\pm}0.34cm$, $-0.02{\pm}0.25cm$ in longitudinal and lateral directions. ITV-PTV margins for SBF were 0.67 cm (vertical), 0.99 cm (longitudinal), and 0.83 cm (lateral), respectively. On the other hand, ITV-PTV margins for Frameless immobilizer were 0.75 cm (vertical), 0.96 cm (longitudinal), and 0.72 cm (lateral), indicating less than 1 mm difference for all directions. In conclusion, stereotactic body frame improves reproducibility of patient setup, resulted in 0.1~0.2 cm in both vertical and longitudinal directions. However the improvements are not substantial in clinic considering the effort and time consumption required for SBF setup.

Geometric Correction of Vehicle Fish-eye Lens Images (차량용 어안렌즈영상의 기하학적 왜곡 보정)

  • Kim, Sung-Hee;Cho, Young-Ju;Son, Jin-Woo;Lee, Joong-Ryoul;Kim, Myoung-Hee
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.601-605
    • /
    • 2009
  • Due to the fact that fish-eye lens can provide super wide angles with the minimum number of cameras, field-of-view over 180 degrees, many vehicles are attempting to mount the camera system. Camera calibration should be preceded, and geometrical correction on the radial distortion is needed to provide the images for the driver's assistance. However, vehicle fish-eye cameras have diagonal output images rather than circular images and have asymmetric distortion beyond the horizontal angle. In this paper, we introduce a camera model and metric calibration method for vehicle cameras which uses feature points of the image. And undistort the input image through a perspective projection, where straight lines should appear straight. The method fitted vehicle fish-eye lens with different field of views.

  • PDF

레이저산업의 부활 (II. 산업용 레이저)

  • Lee, Min-Gyeong
    • The Optical Journal
    • /
    • s.153
    • /
    • pp.47-62
    • /
    • 2014
  • ${\blacksquare}$ 목적 * 우리나라 주력산업분야(자동차, 조선, 항공, 기계, 로봇, 반도체 등)에 절단, 가공, 용접, 리소그라피, 마킹, 열처리, 합성, 표면처리 등의 방식으로 활용되고, 융 복합산업(의료, 에너지, 영상, 군수, 신소재, 센서)에 광원으로 응용되는 산업용 고출력 레이저의 산업 생태계 분석을 통하여 기존 산업의 고부가화와 신산업의 경쟁력을 견인 ${\blacksquare}$ 주요현황 * (시장현황) 2011년부터 2014년까지 고출력 레이저의 시장규모는 4,452백만불(5조 463억원)에서 5,255백만불(5조 9,565억원)으로 연평균 5.7% 성장 전망 * (제품기술동향) 3세대 레이저인 광섬유 레이저와 고출력 다이오드 레이저, DPSS 레이저 등이 기술혁신을 거듭하면서 1, 2세대 레이저를 대체해 가면서 높은 수준의 성장을 거듭할 것으로 전망. 산업용레이저의 주요선진국 대비 국내 기술수준은 전체적으로 44.5%정도로 취약 * (기업동향) Coherent, Trumpf, Cymer, IPG Photonics, Rofin-Sinar 5개사가 전체시장의 55%이상을 점유하고 있으며 대부분 수직계열화를 통해 경쟁력 확보. 최근 중국의 Han's 사가 자국정부의 지원을 통해 급 부상 ${\blacksquare}$ 시사점 * 산업용 레이저를 이용한 응용기술 부분 투자가 과거에는 단기 경제적 성취는 이로웠으나, 현재에 이르러 레이저 혹은 레이저 시스템이 필요할 때마다 외국에서 관련 핵심부품, 모듈 등을 수입해야하는 실정에 이르렀음. 향후 레이저 국산화를 위한 노력과 함께 후방 소재.부품의 전략적 투자를 통해 산업의 건강한 선순환생태 환경을 조성하여 산업 경쟁력을 갖추어야 함.

  • PDF

Developing an Assessment Model for Major Cost-Increasing Factors in Skyscraper Construction Using FMEA (FMEA 기법을 이용한 초고층 건축시공의 원가 증가요인 평가모델의 개발 방법론 연구)

  • Kim, Ki-Kook;Gang, Ji-Sun;Kim, Han-Soo
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2006.11a
    • /
    • pp.507-510
    • /
    • 2006
  • Recently, the skyscrapers are increasing. There are major cost-increasing factors to management in the skyscraper construction. The more projects are large like the skyscraper construction, the more systematic methods and tools are needed for cost control. This study proposes an assessment model for major cost-increasing factors in skyscraper construction using FMEA.

  • PDF

Relationship Between Vergence Facility and Fusional Vergence (버전스용이와 융합버전스의 관계)

  • Shin, Hoy-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.37-42
    • /
    • 2009
  • Purpose: There is uncertainty if the vergence facility would provide clinically significant supplementary information to the fusional vergence measurements. The purpose of this study was to determine the relationship between vergence facility and fusional vergence in a group of symptomatic subjects. Methods: A total of 114 symptomatic subjects aged 9 to 13 years, who passed the vision screening test, participated in this study. Vergence facility was measured with 8$\Delta$ BI/8$\Delta$ BO flipper lenses and a suppression control target, the 20/30 letter line on Vectogram 9 (Bernell, USA). Near fusional vergence was measured with a single 20/30 vertical line target by Von Graefe technique. In order to avoid excessive convergence stimulation, negative fusional vergence (NFV) range (blur, break and recovery) was measured followed by positive fusional vergence (PFV) ranges (blur, break and recovery). Results: Pearson correlations were calculated and showed no correlations between vergence facility and any of fusional vergence measurements (p>0.05). Also, there were no significant differences of vergence facility measurements on the compensating vergence that passed or failed Sheard and Morgan's criterion for comfortable vision (p>0.05). Conclusions: There was no correlation between vergence facility and fusional vergence among symptomatic subjects. Hence, both vergence facility and fusional vergence should be assessed for those with binocular dysfunction in order to make an accurate diagnosis and management plan.

  • PDF