• Title/Summary/Keyword: 수직선배열

Search Result 63, Processing Time 0.03 seconds

Flow Direction and Source Area of the Ipbong Andesite in Western Yeongdeok, Korea (영덕 서부 입봉안산암의 유향과 공급지역)

  • Hwang, Sang-Koo;Ham, Hee-Soo
    • The Journal of the Petrological Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.293-301
    • /
    • 2010
  • The Ipbong Andesite is a stratigraphic unit which is lain in the lowermost part of the Yucheon Group in the southeastern Yeongyang sbbasin. The Ipbong Andesite is lain on the Sinyangdong Formation and under the dacitic tuff, and consists in its lower andesitic tuffs and upper lavas. The andesitic lavas show some alignments of elongate vesicles filling with calcite amygdules and plagioclase microphenocrysts, and show rare imbrication of the microphenocrysts in vertical sections parallel to them. The flow directions which is measured from the flow indicators are laid along NNW-SSE trend in the eastern part and NNESSW in the southwestern part of the study area. Movement pattern from the flow lineations suggests that the Ipbong Andesite had a fanlike pattern by flowing southwards from the mid-northern part. Accordingly a small diorite stock in the mid-northern part area may probably be a source area of the Ipbong Andesite.

Introduction of Hindfoot Coronal Alignment View (후족부 관상면 배열 영상에 대한 고안)

  • Moon, Il-Bong;Jeon, Ju-Seob;Yoon, Kang-Cheol;Choi, Nam-Kil;Kim, Seung-Kook
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.225-228
    • /
    • 2006
  • Purpose: Accurate clinical evaluation of the alignment of the calcaneus relative to the tibia in the coronal plane is essential in the evaluation and treatment of hindfoot pathologic condition. Previously described standard anteroposterior, lateral, and oblique radiographic methods of the foot or ankle do not demonstrate alignment of the tibia relation to the calcaneus in the coronal plane. The purpose of this study was to introduce hindfoot coronal alignment view. Material : 1) Both feet were imaged simultaneously on an elevated, radiolucent foot stand equipment. 2) Both feet stood on a radiolucent platform with equal weight on both feet. 3) Both feet are located foot axis longitudinal perpendicular to the platform. 4) Silhouette tracing around both feet are made, and line is then drawn to bisect the silhouette of the second toe and the outline of the heel. 5) The x-ray beam is angled down approximately $15^{\circ} to $20^{\circ} Result : 1) This image described tibial axis and medial, lateral tuberosity of calcaneus. 2) Calcaneus do not rotated. 3) The view is showed by talotibial joint space. Conclusion: Although computed tomographic and magnetic resonance imaging techniques are capable of demonstrating coronal hindfoot alignment, they lack usefulness in most clinical situations because the foot is imaged in a non-weight bearing position. But hindfoot coronal alignment view is obtained for evaluating position changing of inversion, eversion of the hindfoot and varus, valgus deformity of calcaneus.

  • PDF

Theory of efficient array observations of microtremors with special reference to the SPAC method (SPAC 방법에 근거한 상시진동의 효과적 배열 관측 이론)

  • Okada, Hiroshi
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.1
    • /
    • pp.73-85
    • /
    • 2006
  • Array observations of the vertical component of microtremors are frequently conducted to estimate a subsurface layered-earth structure on the assumption that microtremors consist predominantly of the fundamental mode Rayleigh waves. As a useful tool in the data collection, processing and analysis, the spatial autocorrelation (SPAC) method is widely used, which in practice requires a circle array consisting of M circumferential stations and one centre station (called "M-station circle array", where M is the number of stations). The present paper considers the minimum number of stations required for a circle array for efficient data collection in terms of analytical efficacy and field effort. This study first rearranges the theoretical background of the SPAC algorithm, in which the SPAC coefficient for a circle array with M infinite is solely expressed as the Bessel function, $J_0(rk)$ (r is the radius and k the wavenumber). Secondly, the SPAC coefficient including error terms independent of the microtremor energy field for an M-station circle array is analytically derived within a constraint for the wave direction across the array, and is numerically evaluated in respect of these error terms. The main results of the evaluation are: 1) that the 3-station circle array when compared with other 4-, 5-, and 9-station arrays is the most efficient and favourable for observation of microtremors if the SPAC coefficients are used up to a frequency at which the coefficient takes the first minimum value, and 2) that the Nyquist wavenumber is the most influential factor that determines the upper limit of the frequency range up to which the valid SPAC coefficient can be estimated.

Development of a Vertical polarized Leaky-wave Waveguide Slot Array Antenna for Receiving the Ku-band Direct Broadcasting Satellite Signals

  • Lim, Gye-Jae
    • Journal of Satellite, Information and Communications
    • /
    • v.2 no.2
    • /
    • pp.10-15
    • /
    • 2007
  • Small size and low profile antenna for mobile vehicular-top-mounted is needed in satellite communication services such as DBS, Satellite Internet and VSAT. In middle latitudes, the development of an array antenna which has the conformal, low profile and 45 degree beam tilted configuration, and has the high gain with sharp beamwidth, low sidelobe and low loss is required for Ku-band satellite communication. In this paper, in order to meet with these performances, an array antenna consisting of the vertical polarized waveguide longitudinal slots based on the leaky-wave mode of traveling wave antenna is proposed. An array antenna consisting of 16 leaky-wave elements is showing 30 dBi of gain, 4.9 degree of beamwidth, below than -20 dB of sidelobe level, 45 degree of beam tilt angle in center frequency. Feed network designed by waveguide cooperated feed shows good performance of wideband and low loss.

  • PDF

A Study on the Electromagnetic Interference from 765kV Test Line (765kV 시험선로에서의 전자파 장해에 관한 연구)

  • 김정부;이동일;신구용;양광호;안희성;구자윤
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.7 no.1
    • /
    • pp.36-42
    • /
    • 1996
  • In general, EMI(electromagnetic interference) from EHV(extra high voltage) power lines above 50kV cause interference to AM radio and low VHF television reception. This paper describes the results of long-term measurement of RI and TV1 in 765kV, double circule of $6\times29.59mm$(1.65k inches) diammer $480mm^{2}$(Rail) ACSR conductors in suitable for 766kV transmission lines to provide acceptable EMI at 15m fro the beneath of outmost phase.

  • PDF

Time-Domain Geoacoustic Inversion via Light Bulb Source Signal Matching (전구음원 신호를 이용한 시간영역 지음향학적 인자 역산)

  • Kim Kyungseop;Park Cheolsoo;Kim Seongil;Seong Woojae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.6
    • /
    • pp.334-342
    • /
    • 2005
  • In this Paper. a time-domain geoacoustic inversion was performed using the bulb signals measured during MがU. 04 experiment conducted in the East Sea of Korea in 2004. An obiective function was defined as a direct cross-correlation between the measured and the simulated signals in time domain. The ray theory was used to model the wave propagation in time domain and optimizations were Performed using VFSA (very fast simulated annealing) algorithm. Comparison of inversion results with those from transmission loss matching (an accompanying paper in this issue of the Journal of the Acoustical Society of Korea) shows that Parameters are consistently inverted. Direct time series comparisons between the measured signals and the simulated signals are Presented based on inversion results.

Analysis of the electrostatic induction effects on Parallel Circuit in 765kV test Line Analysis of electrostatic effects at 765kV test Line (수직 2회선 765kV 송전선로의 1회선 휴전작업 안전성검토)

  • Lee, S.D.;Lee, D.I.;Kwak, J.S.;Jeon, M.R.;Kweon, T.W.;Kim, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.358-360
    • /
    • 2002
  • 한국전력은 당진화력발전소로부터 신안성 변전소까지의 세계 최초로 수직배열 2회선의 765kV 송전선로를 건설하여 2002년 4월부터 1회선을 765kV로 가압하고 1회선은 345kV로 상업운전을 시작하였으며 2003년 이후 2회선을 모두 765kV 전압으로 가압 예정이다. 이러한 765kV 송전선로는 계통운영 측면에서 2회선 동시 휴전이 어려워 1회선 휴전 작업 및 향후 활선작업이 요구되는 중요선로이다. 765kV 1회선 휴전작업을 위해서는 765kV로 가압된 선로로부터 휴전선로의 작업자에게 발생될 수 있는 전기적 유도량에 대해 사전 검토하여 안전성을 확보하는 것이 필수적이다. 한국전력공사와 전력연구원은 1회선 휴전작업에 대한 안정성 검토를 위해 고창 실증시험선로를 이용하여 전기적 유도현상에 대한 시험을 실시하였다. 이 논문에서는 실증시험 선로를 모델로한 정전유도의 계산 결과와 실측치를 각각 비교, 검토하였다.

  • PDF

Verification of Drag Reduction Effect of Outer-layer Vertical Blades based on Model Test (모형선 시험을 통한 외부경계층 수직 날 배열의 저항저감효과 검증)

  • Lee, Seong Hoon;Lee, Inwon
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.3
    • /
    • pp.26-34
    • /
    • 2018
  • In the present study, an experimental assessment has been made of the drag reducing efficiency of the outer-layer vertical blades, which were first devised by Hutchins(1). A detailed flow field measurements have been performed using 2-D time resolved PIV with a view to enabling the identification of drag reduction mechanism. In addition, an experimental investigation has been made of the applicability of outer-layer vertical blades to real ship model. The arrays of outer-layer vertical blades have been installed onto the flat side and flat bottom of a 300k KVLCC model. A series of towing tank test has been carried out to investigate resistance (CTM) reduction efficiency with various geometric parameters and installed places of blades. The installation of vertical blades led to the CTM reduction of 1.44~3.17% near the service speed.

Electrical Resistivity-Measurements for the Detection of Fracture Zones in the Woraksan Granitic-Bodies (월악산화강암체의 파쇄대규명을 위한 전기비저항탐사)

  • 김지수;권일룡
    • The Journal of Engineering Geology
    • /
    • v.7 no.2
    • /
    • pp.113-126
    • /
    • 1997
  • Electrical resistivity methods of dipole - dipole array profiling and Schiumberger array sounding were tested on a segment of the Woraksan granitic batholith for the research into the imaging of irregular attitudes of fracture zones in the crystaaline rock in terms of processing and interpretation schemes. By the dipole - dipole array method, inhomogeneities such as small scale of fracture zones were properly delineated down at some depth even within hard rock environment. Fracture zones were interpreted to be at the boundaries between the high amplitude zone and very low amplitude zone in the resistivity plot and they were also successfully outlined in two - dimensional layer and pseudo - three - dimensional volume constructed by the incorporation of vertical sounding data. The surface location of the fracture zones was correlated by the zero - crossing point in the VLF(very low frequency) electromagnetic data. Pseudo - three - dimensional attitudes of fracture zones were efficiently illuminated by optimum projection angle. The mean of bulk resistivity for the Woraksan granite and the near fracture zones is estimated to be approximately of 4,000 ohm - m which is much higher than the value of 700 ohm - m for the Rwachunri limesilicate environment. This difference is due to both the rock type, i.e., biotite granite vs limesilicate, and the occurrence of secondary openings of fold and fault associated with the intrusion of granite. In this study statistical analyses on the resistivity color plot were performed in terms of three representative statistical moments, i.e., standard deviation, skewness, and kurtosis. The fracture zones in the standard deviation plot were characterized by the higher value, compared to the value of homogeneous portion. The upper boundary of the high resistivity zone was also successfully delineated in the skewness and kurtosis plots.

  • PDF

Study on Optimization of Detection System of Prompt Gamma Distribution for Proton Dose Verification (양성자 선량 분포 검증을 위한 즉발감마선 분포측정 장치 최적화 연구)

  • Lee, Han Rim;Min, Chul Hee;Park, Jong Hoon;Kim, Seong Hoon;Kim, Chan Hyeong
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.162-168
    • /
    • 2012
  • In proton therapy, in vivo dose verification is one of the most important parts to fully utilize characteristics of proton dose distribution concentrating high dose with steep gradient and guarantee the patient safety. Currently, in order to image the proton dose distribution, a prompt gamma distribution detection system, which consists of an array of multiple CsI(Tl) scintillation detectors in the vertical direction, a collimator, and a multi-channel DAQ system is under development. In the present study, the optimal design of prompt gamma distribution detection system was studied by Monte Carlo simulations using the MCNPX code. For effective measurement of high-energy prompt gammas with enough imaging resolution, the dimensions of the CsI(Tl) scintillator was determined to be $6{\times}6{\times}50mm^3$. In order to maximize the detection efficiency for prompt gammas while minimizing the contribution of background gammas generated by neutron captures, the hole size and the length of the collimator were optimized as $6{\times}6mm^2$ and 150 mm, respectively. Finally, the performance of the detection system optimized in the present study was predicted by Monte Carlo simulations for a 150 MeV proton beam. Our result shows that the detection system in the optimal dimensions can effectively measure the 2D prompt gamma distribution and determine the beam range within 1 mm errors for 150 MeV proton beam.