• Title/Summary/Keyword: 수중 조명

Search Result 52, Processing Time 0.022 seconds

PHOTOTAXIS OF FILEFISH, CONGER EEL AND CRUCIAN CARP (어류의 주광성에 관한 연구 -쥐치, 붕장어, 붕어-)

  • YANG Yong-Rhim
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.13 no.1
    • /
    • pp.1-13
    • /
    • 1980
  • The purpose of the present study is to find the light intensity which induces maximum gathering rate and to observe the variation of the gathering rate both in daytime and at night by using three species of commercial fishes: filefish, Stephanolepis cirrhifer (Temminck et Schlegel), conger eel, Astroconger myriaster (Brevoort) and crucian carp, Carassius oarassius (Linnaeus). An experimental tank $(360L\times50W\times55Hcm)$ was set up in a dark room. An illumination system was attached to one end of the tank to control horizontal, light intensity. Six artificial light sources were prepared by combination of two light bulbs (5W, 150W) and seven filters. During the experiment water depth was maintained 50 cm level in the tank. The tank was marked into six longitudinal sections each being 60 cm long to observe the distribution of fish. The fish were acclimatized in dark condition for 40 minutes prior to the main experiment. Upon turning on the light, the number of fish .in each section was counted 40 times every 30 seconds, and the gathering rates were obtain from the average number of fish in each section. In filefish the light intensity inducing maximum gathering rate was 0.7 lx(0.5-1.1 lx), and there nab little difference between day and night. Gathering rate varied propotionally to the length of illumination time. In conger eel the light intensities inducing maximum gathering rate were 1.9 lx(1.2-2.9 lx) in daytime and 5.2 lx (3.2-7.7 lx) at night. Thus, there was a considerable difference between day and night, but the gathering rate remained almost unchanged regardless to the length of illumination time. In crucian carp gathering rate did not show a definite pattern hut fluctuated irregularly. The gathering rate, however, was slightly higher at 16.21 lx, and there was little difference between day and night.

  • PDF

A High Effeciency Functional Water Generation Characteristics by Corona Discharge and Space Charge Control (코로나방전과 공간전하제어에 의한 고효율 기능수 발생특성)

  • 김진규
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.101-107
    • /
    • 2002
  • A novel oxidant generation and ion precipitation cell with slits on parallel plate electrodes was proposed instead of the conventional parallel plate type. An investigation was carried out on the effect of the number and size of slits on ion precipitation and oxidant generation characteristics, evidenced by eliminated space charge limiting action and by elevated electric fields in active interelectrode sparing. Consequently, very high ion precipitation and dense oxidant generation characteristics can be realized by having slits un the electrodes of conventional cells as these slits increase the electric fields and decrease the space charge limiting actions in interelectrode spacing.

Development of 1.2kW LED Light with Water-Air Circulation (수공냉 대류방식을 이용한 1.2kW급 LED 조명등 개발)

  • Yoon, Byung-Woo;Song, Jong-Kwan;Park, Jang-Sik;Kwon, Hong-Bae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.5
    • /
    • pp.615-622
    • /
    • 2015
  • As the development of high efficiency and high flux density LEDs, the trend of illumination lamp industry transfers from conventional-lamps to the LED-lamps. For energy efficiencies, LED lamps are superior to the conventional lamps, but they have heat problems. Especially, the heat problems are severe for the high luminance lamps. They degrade the soldering point of the metal PCB, and shorten the life cycle of LEDs. So, the solution of the heat sinking is very important to develop high luminance LED lamps. This study suggested a new method to solve the heat problems for high luminance LED lamps, and developed a LED lamp which has 1200W power. In this study, a water jacket is installed to the LED lamp, and the cooing water is circulated by a water pump.

A Characteristics on Water Quality Analysis Used the High-Voltage Discharge (고전압 방전을 이용한 수질분식에 관한 특성)

  • Cho, Kook-Hee;Kim, Young-Bae;Cho, Moon-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.156-161
    • /
    • 2004
  • In this research, we used discharge tube without dielectric bead or with dielectric beads(SiO$_2$, $Al_2$O$_3$, or ZrO$_2$), and discharge in water at High-voltage pulse$.$DC power supply for removal of Escherichia coli. At the result of experiments, the removal characteristics of Escherichia coli appeared relation ratio to input voltage. Because, the electric field of discharge tube is increased when input voltage is increased. And, discharge tube used dielectric bead(ZrO$_2$), the removal characteristics of Escherichia coli was better than cases of else. And discharge used DC Power, the removal characteristics of Escherichia coli was better than AC Pulse Power.

Potential Reduction and Energy Dispersion Due to Ionization Around the Submerged Ground Rod (수중에 잠긴 접지전극 주변에서의 이온화에 의한 전위저감 및 에너지방출)

  • Choi, Jong-Hyuk;Ahn, Sang-Duk;Yang, Soon-Man;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.92-99
    • /
    • 2009
  • Deeply-driven ground rod in the rainy season may contact with rainwater and ground water. When surge voltages are applied to the submerged ground rods, the ionization around the ground rods are occurred. Ionization in soil and/or water is affected in dynamic performance of ground rod systems. This work aims at studying the transient performance of ground rod system under impulse voltage using scale model in an electrolytic tank. The potential reduction and energy dispersion caused by ionization were treasured and quantitatively analyzed using the Matlab Program. As a result, the peak voltage at the terminal of ground rod was varied with water resistivity and charging voltage of Marx generator. The potential at the terminal of the ground rod was approximately reduced to a half of the applied voltage just below breakdown voltage. Also the energy more than half of the applied energy was dispersed through the ground rod due to ionization just below breakdown voltage.

A Study on a Visible Light Communication using LED in Under-water Environment (LED조명을 이용한 수중환경에서의 VLC 연구)

  • Jung, Hui-Sok;Yang, Yeon-Mo;Huh, Kyung-Moo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.5
    • /
    • pp.1-6
    • /
    • 2011
  • LED(Light Emitting Diode) components have advantages of longer lifetime, lower power consumption and easy-to-control, compare to normal lamp and fluorescent light, according to the development of recent technologies. Thus, lots of illuminations which utilize LED components could be used. Recently, Visible Light Communication(VLC) which is a part of communication technologies, utilizing high speed response characteristic of LED components, started receiving public attention. In case of VLC, there is no need of frequency allocation due to no use of radio, but also no interference exists during data transmission, much different in ISM((Industrial Scientific Medical band). This is the reason why a lot of research results about VLC are becoming issued. In this paper, a survey of feasibility for using VLC utilizing an original LED illumination for underwater applications has been done and a primitive possibility of its application has been examined.

ATPDraw Simulation for Transient Phenomena Analysis of Electrical Shock Underwater (수중 전격 과도현상 해석을 위한 ATPDraw 시뮬레이션)

  • Jung, Jong-Wook;Jung, Jin-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.6
    • /
    • pp.48-54
    • /
    • 2007
  • This paper describes the analysis of transient phenomena on the point that a human body suffers an electrical shock. A couple of case studies were discussed by using an ATPDraw simulation tool. Two models for the case studies were constructed on the assumption that the electrical shock event takes place under water to simulate the severest condition ; the first model that the human body contacts with an energized part exposed to water ; the second model that both hands and feet simultaneously contact with the ground under water. After modeling, the transient phenomena for the models were analyzed by comparing the voltages and currents calculated at each part of the human body. As a result steep front kicks in voltage and current were observed as transient phenomena on the point that the human body contacts with the energized part exposed to water in the first model and the magnitudes of the kicks considerably increased. It was considered however, the effect of the kicks due to the commercial power source on the human body could be neglected because the product of the current through the body and the short duration is less than the safety limit. When both hands and feet simultaneously contact with the ground in the second model, the voltage generally decreased all over the body parts, while the current flowing through the chest abruptly increased. The duration of this current was very shot, as well, thus its effect on the electrical shock is considered insignificant. After all, it was confirmed through the simulation results that the electrical shock depends on the magnitude in voltage and the body impedance.

Experimental Studies on the Risk Assessment of Electrical Fire and Shock of LED Lighting for Outdoor (옥외용 LED 조명의 전기화재 및 감전 위험성 평가에 대한 실험적 고찰)

  • Kim, Hyang-Kon;Gil, Hyoung-Jun;Kim, Dong-Ook;Kim, Dong-Woo;Lee, Ki-Yoen;Moon, Hyun-Wook;Kim, Hyeog-Soo;Kim, Myung-Soo;Kim, Man-Geon
    • Congress of the korean instutite of fire investigation
    • /
    • 2011.04a
    • /
    • pp.77-97
    • /
    • 2011
  • In this paper, we studied risk assessments of electrical fire and shock of LED lightings for outdoor. We examined national regulations about the LED lighting for outdoor and analyzed the appearances and compositions of LED lightings. And, We experimented about water proof, line to line fault, line to line breakdowm, overvoltage, line to line leakage in overhead line or water of LED lighting. From experimental results, we know that there are risks of electrical fire and shock by abnormal conditions at the LED lighting. Therefore, the uses of protective devices and insulated type of converter are required for the electrical safety. We expect that the results of this study would be helpful for the improvement of regulations and standards for electrical safety and for the investigations of electrical accidents of LED lightings.

  • PDF

Discharge Characteristics near the tip of needle in water (수중에서 침전극 끝단의 방전특성)

  • Lee, Bok-Hee;Choi, Jong-Hyuk;Park, Geon-Hun;Jun, Byung-Wook;Kim, Hoe-Gu;Beak, Young-Hwan;Lee, Kyu-Sun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.239-241
    • /
    • 2007
  • In this paper we describe streamer propagations characterizing underwater pre-breakdown and breakdown behaviour under impulse voltages. Streamer corona branches in lower resistivities are much thicker and brighter than those in higher resistivities. The negative streamer channels not only have more branches but also widely spread out than the positive streamer channels. The succession of streamer coronas during re-breakdown produces a stepwise propagation. The pre-breakdown currents consist of the conduction current and streamer corona current pulses.

  • PDF