• Title/Summary/Keyword: 수중 방류

Search Result 71, Processing Time 0.032 seconds

Prediction of Near-Field Dilution Changes Due to Treatment Capacity Expansion of Masan-Changwon Municipal Wastewater Treatment Plant (마산.창원 하수종말처리장 증설에 따른 근역희석률변화 예측)

  • 유승협
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.12 no.2
    • /
    • pp.53-69
    • /
    • 2000
  • For the case of the capacity increase of Masan-Changwon wastewater treatment plant, the changes of near-field dilution rates due to the increased discharges into Masan Bay from the submerged multipart-diffuser were predicted by using CORMIX model. As the increase of wastewater discharges from currently 280,000 m3f day to 720,000 m3fday by 2011, the dilution rates become much lower than the present rates. To enhance the reduced dilution rates, the engineering design changes of diffuser length and alignment were considered as an optimal engineering option. According to the results of the model simulations for these changes, the dilution rates were increased in the strong ambient current of spring tide, but they were not affected by these changes in the weak current of neap tide in Masan Bay. From the analysis of oceanographic survey data, new outfalls sites have been searched. A promising outfalls site is selected and proposed on the basis of maximum obtainable dilution rates predicted by the model simulations.

  • PDF

Analysis of Discharge Characteristics for a Control Gate in a River (하도내 조절수문 방류특성 해석)

  • Son, Kwang Ik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4B
    • /
    • pp.309-314
    • /
    • 2011
  • Analysis of discharge characteristics through control gates at river crossing structures is important for an effective water level control and water resources management. In recent years, many river control structures in four major rivers are under construction but only few researches on discharge characteristics at control gates could be found in Korea. The discharge characteristics depend on both shape of control gates and the effects of downstream water-depth. In this research, classification index for discharge patterns (free weir, submerged weir, free orifice, submerged orifice) through a control gate were reviewed with $h_g/h_1$, $h_3/h_g$, and $h_3/h_1$. Classification criteria of discharge patterns were also suggested. Representative discharge estimation equations for each discharge patterns were adopted and discharge coefficients were developed from a hydraulic model for a specific control gate which will be constructed in Nakdong river. Reliability of the derived discharge equation and coefficients were confirmed by comparisons between the real discharge in a model and the predicted discharge from the results of this research.

Heat Shock Protein 90 Gene Expression in Juvenile Sea Cucumber Apostichopus japonicus (Echinodermata; Holothuroidea) according to Releasing Methods (어린 돌기해삼 Apostichopus japonicus (Echinodermata; Holothuroidea) 방류 방법에 따른 열충격단백질90 유전자의 발현 분석)

  • Lee, Dong-Han;Lee, Seungheon;Jeong, Dong-Bin;Sohn, Young Chang
    • Journal of Marine Life Science
    • /
    • v.7 no.1
    • /
    • pp.29-36
    • /
    • 2022
  • Sea cucumber, Aposticopus japonicus, is a major invertebrate species in the coastal regions of Korea. To evaluate the short-term stress levels according to the releasing methods, this study investigated the gene expression profiles of heat shock protein 90 (HSP90) by real-time quantitative polymerase chain reaction. When the juvenile sea cucumbers were packed in the vinyl bag with oxygen followed by transportation for 30 min or air-exposed for 1 h, the HSP90 gene expression levels in the experimental groups were significantly increased compared to those of the control groups (transported group, p=0.001; air-exposed group, p=0.032). The experimental group at 6 h post-release by seed-spreading method and at 2~6 h post-release by underwater hose-releasing method on board a fishing boat showed that the levels of HSP90 gene expression were not statistically significant but decreased slightly compared to the control group (seed-spreading group, p=0.069; hose-releasing group, p=0.093). On the other hand, the HSP90 gene expression showed an increasing pattern as the time passed (~6 h) after underwater release of juvenile sea cucumbers by divers (p=0.061). These results suggest that HSP90 gene expression can be used to investigate short-term stress response and effective releasing methods of juvenile sea cucumbers.

하수 수중방류에 의한 확산영향 예측

  • Song, Hyeon-U;Kim, Gang-Min;Lee, Jung-U
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2018.05a
    • /
    • pp.191-192
    • /
    • 2018
  • 해안을 따라 인구밀도가 증가하고 임해지역공단 등 산업시설이 밀집하여 처리되지 않은 하 폐수가 증가하고 있다. 특히, 최근엔 필리핀 보라카이와 같이 관광 위락시설에 의한 하수가 대량으로 발생하고 있다. 또한, 세계적으로 거의 모든 국가의 주요 해안도시는 이러한 도시하수를 바다로 방류하고 있다. 현재로선 이러한 하 폐수의 처리는 바다의 자정능력(self-purification capacity) 한계를 고려한 하수의 해양으로의 방류가 최선의 방법으로 판단된다. 현재 국내에서는 지역에 따른 배출허용기준에 따라 하수의 처리수 방류가 규제되고 있지만, 확산영역에 대한 법적 기준치는 제시되지 않고 있으며, 인근에 위치한 권리자들과의 이해관계 해결에만 몰두하고 있는 실정이다. 또한 확산영향예측이 원역 해석모형(Far Field analysis model)에 의해 수행되기 때문에 근역(Near Field)에서의 영향을 간과하고 있다고 판단된다. 따라서 금회 연구에서는 기존 연구결과를 기준하여 특정해역에 대한 원역과 근역 해석에 따른 확산영향 예측을 수행하고 그 결과를 비교하여 앞으로의 해석방법을 제시하고자 한다.

  • PDF

Seasonal Variations of Near-Field Dilutions of Submerged Multiport-Diffuser Discharges in Masan Bay (마산만 수중 방류수의 계절별 근역희석률 변화)

  • 강시환;박광순
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.11 no.2
    • /
    • pp.116-126
    • /
    • 1999
  • In this paper, we have studied the seasonal vanatIons of near-field dilutions of wastewater discharged from the submerged mutiport-diffuser in Masan Bay. Seasonal changes of temperature and salinity, and tidal currents were measured at 16 stations in Masan Bay. Based on the observed ambient field data, the seasonal changes of near-field dilutions due to ambient current and density fields were calculated by CORMIX model. Because of the shallow ambient water depth of 15 m, the density profiles are isopycnal in autumn and winter seasons, in which the dilution factors were the highest, 168 with the strong spring-tidal current and 110-120 with the weak neap-tidal current. As the season changes from spring to summer, the dilution factors are considerably reduced by the factor of 2 as the thermocline is getting deepened up to Sm in depth in summer. In the case of a weak ambient current, the dilution factor in summer was reduced to 1/4 of the dilution in winter. However, with strong ambient current the difference between summer and winter dilutions becomes relatively small by 30%. The results indicate that the seasonal variation of near-field dilution is very large up to 4 times with a weak neap-tidal current, but its variations become small under a strong ambient current of spring tide in MasanBay.

  • PDF

Design of the Submerged Outlet Structure for Reducing Foam at a Power Plant using a Numerical Model Simulating Air Entrainment (공기연행 수치모형을 이용한 발전소 거품저감 수중방류구조 설계)

  • Kim, Ji-Young;Kang, Keum-Seok;Oh, Young-Min;Oh, Sang-Ho
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.5
    • /
    • pp.452-460
    • /
    • 2008
  • Anti-foaming agents and foam fences have been used to remove the foam at the outfall of power plants, but there are some problems as consumption of maintenance costs and insufficiency of effect. Therefore, development of the methods how to remove the foam by stable coastal structure has been required. In this study, numerical simulation of air entrainment was carried out to design the submerged outlet structure for reducing foam using curtain walls. The air entrainment rate and the discharge of entrained air change according to the shape of weir and curtain wall. Hence, it is necessary to design the optimum section through comparison of each case. The optimum section which has the maximum rate of foam reduction was determined by the simulation results. In addition, it was found that the flow velocity at the submerged outlet is to be smaller than 1 m/s and the submerged depth of curtain wall is to be taller than height of the submerged outlet section.

Cause Diagnosis and Reduction Measures of Foaming in the Treated Wastewater Outlet of D Wastewater Treatment Plant (하수처리수 방류구의 거품발생 원인진단 및 저감방안: 국내 하수처리장 사례를 중심으로)

  • Shin, Jae-Ki;Cho, Youngsoo;Kim, Youngsung;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.49 no.2
    • /
    • pp.124-129
    • /
    • 2016
  • This study was conducted to suggest the cause analysis and mitigation measures of foaming generated in the effluent of wastewater treatment plant. The foam generated in the outlet connected with the tidal river system was identified as structural problems. And the main cause of foaming was air entrainment by an impinging jet and the internal accumulation by the diffusion barrier. In consideration of these conditions, it present the effective ways such as micro-screen and submerged outlet, to mitigate the foaming generated in the water channel and outlet end.

Concentration Changes of Wastewater Effluent Discharge in the Mixing Bone of Masan Sea Outfall (마산만 해양방류 혼합구역에서의 하수농도 분포 변화)

  • Kang See-Whan;You Seung-Hyup;Kim Sang-Ik;Oh Byung-Cheol;Park Kwang-Soon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.4 no.2
    • /
    • pp.15-24
    • /
    • 2001
  • The concentration changes of discharged wastewater effluents due to ambient current flows and density stratifications in an outfall mixing zone have been investigated by using the outfall mixing zone analysis of Huang et al.[1996]. This analysis was applied to Masan sea outfall case and the concentration distributions of wastewater effluent discharges were simulated using three month period of current-meter data measured in the outfall site. Hourly concentration distributions of wastewater effluents were averaged for the period of 15 days which covers the flow conditions of the neap and the spring tidal currents in Masan Bay. The results show that the wastewater concentrations in the Masan outfall mixing zone were very low due to the higher dilution rates during the period of strong ambient currents and less density stratifications. The higher concentrations in the mixing zone were found in August because of strong density stratifications with low ambient currents. The mixing zone was extended to the west coast beach area because of major tidal current directions. This result can be used to explain the dynamical reasons for the depositional distribution of the contaminated sediments in Masan sea outfall area.

  • PDF

Study on the characteristics of the Tamjin River basin by the verification of the Jangheung Dam discharge (장흥댐 방류량 검증을 통한 탐진강 유역 유출 특성 변화 연구)

  • Park, Jun Su;Seol, Myung Su;Kim, Sung Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.351-351
    • /
    • 2022
  • 현재 우리나라는 기후변화가 심화되고 강우의 불확실성이 높아지면서 자연 재해와 홍수 피해가 증가하고 있고 이에 따른 댐이나 보 운영의 고도화가 요구되고 있다. 특히 댐의 경우 다양한 원인에 의해 상류와 하류에서 홍수 피해가 빈번하게 발생하기도 하며, 방류 조절에 따라 담수 유입으로 인한 해수의 염도 변화나 수질 오염 등의 결과를 야기시킨다. 따라서 효율적인 댐 운영을 위해서는 방류량에 대한 지속적인 검증 측정이 필요하며, 유역 내 상하류 유출 특성 변화에 대한 모니터링이 요구된다. 따라서 본 연구에서는 탐진강 유역에 위치한 장흥군(별천교)관측소와 장흥군(예양교)관측소를 대상으로 가동보 운영과 식생영향, 취수영향, 공사에 따른 수위-유량관계 변화를 분석하였다. 탐진강 최상류에 위치한 장흥군(별천교)관측소의 경우 2013년 이후 유량조사가 이루어지지 않아 2021년 하류 가동보 수문 운영 조건과 수중식생 영향, 취입보 운영 조건에 따른 변화를 모니터링하고 유량측정을 실시하여 수위-유량관계의 변동성을 분석하였다. 또한 탐진강 하류에 위치한 장흥군(예양교)관측소는 기존 설치되어 있던 상하류 가동보에 대해 철거공사가 금년 진행되었으며, 이에 따른 지속적인 모니터링과 유량측정을 통해 흐름 특성 변화를 분석하였다. 추가로 저평수기와 홍수기에 장흥댐 수문 방류량에 대한 검증 측정을 수행하여 고시된 방류량과 실측된 방류량을 각각 적용하여 탐진강 유역 유출 특성 변화에 대해 분석하였다. 결과적으로 본 연구에서는 탐진강 유역 하천 내의 보 운영과 식생, 취수, 공사영향에 따른 모니터링과 유량측정을 통해 신뢰도 높은 수위-유량관계곡선식을 개발하였고, 이를 통해 생산된 유량자료는 정확도가 매우 높은 것으로 분석되었다. 또한 장흥댐 수문 방류량에 대해 실제 측정된 방류량을 유출 분석에 적용한 결과 향상된 결과를 보였으며 정상적인 상하류 관계를 나타냈다.

  • PDF

Sensitivity Analysis to the Design Factor of Ocean Outfall System (방류관 설계인자에 대한 민감도 분석)

  • 김지연;이중우
    • Journal of Korean Port Research
    • /
    • v.14 no.3
    • /
    • pp.361-371
    • /
    • 2000
  • A demand of marine outfall system has been much increased for the effective disposal of the wastewater due to population and industrial development at the coastal areas. The outfall system discharges primary or secondary treated effluent into the coastline, or at the deep water, or between these two. The discharge is carried out by constructing a pipeline on the sea bed with a diffuser or with a tunnel, risers and appropriate. The effluent, which has a density similar to that of fresh water, rises to the sea surface forming plume or jet, together with entraining the surrounding salt water and becomes very dilute. Thus there have been growing interests about plume behaviour around the outfall system. Plume or jet discharged from single-port or multi-port diffuser might cause certain impacts on coastal environment. Near field mixing characteristics of discharged water field using CORMIX model have been studied for effective outfall design various conditions on ambient current, depth, flow rate, effluent concentration, diffuser specification, port specification etc.. This kind of analysis is necessary to deal with water quality problems caused by the ocean discharge. The analyzed result was applied to the Pusan Jungang effluent outfall system plan.

  • PDF