Property Analysis of Waterproofing and Corrosion-Resistant Performance in Concrete Water Supply Facilities (상수도시설 콘크리트 수조구조물에서의 염화이온 침투저항 특성분석)

  • Kwak, Kyu-Sung;Ma, Seung-Jae;Choi, Sung-Min;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.2
    • /
    • pp.122-131
    • /
    • 2015
  • The purpose of this study is to understand the necessity for waterproofing and corrosion-resistant technique application on concrete water tank used in water supply. Relevant research materials and regulation were collected, reviewing for the case studies of sample structures aged over 20 years, and experimental studies on chloride conduction for the high performance concrete and penetration properties of water repellency of liquid type materials. The result is that the concrete water tank in the water supply is needed for waterproofing and corrosion-resistant material coating to maintain long term durability due to the constant environmentally induced degradation deterioration often caused by chloride attack.

A Study on Performance Test Method of Polyurea Waterproofing System Applied to the Concrete Water Tank (콘크리트 수조에 적용되는 폴리우레아 방수방식 공법의 내구성 향상을 위한 시험 평가 방법에 관한 연구)

  • DO, Kwang-Ku;Song, Je-Young;Kim, Byoungil;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.12-13
    • /
    • 2020
  • Construction projects and buildings are becoming taller and larger, and the size of water tanks of production facilities and high-rise buildings is also gradually increasing. Most large water tanks apply a waterproofing layer to the water tank type concrete structure. The application of polyurea coating materials, which are excellent in water resistance, chemical resistance, physical performance, rapid hardening, and workability is gradually increasing as waterproofing and anticorrosion layer for water tank. As a result, defects such as water leakage and damage to the waterproofing layer are continuously occurring, causing production disruption, setback to users. Therefore, it is required to review suitability through performance verification of the waterproofing and anticorrosion system.

  • PDF

A Study on the Inventory Estimation for the Activated Bioshield Concrete of KRR-2 (연구로 2호기 방사화 수조 콘크리트의 재고량 평가에 관한 연구)

  • Hong, Sang Bum;Seo, Bum Kyoung;Cho, Dong Keun;Jeong, Gyeong Hwan;Moon, Jei Kwon
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.202-207
    • /
    • 2012
  • The radioactivity inventory significantly affects all steps of decommissioning projects including planning, cost estimation, risk assessment, waste management and site remediation. The decommissioning project of the KRR-2 was completed in 2009 and a large amount of activated concrete waste was generated. The bioshield concrete, containing minute amount of impurity elements, was activated by neutron reaction during the operation of the reactor. A variety radionuclides was generated in the concrete, including $^3H$, $^{14}C$, $^{55}Fe$, $^{60}Co$ $^{63}Ni$, $^{134}Cs$, $^{152}Eu$ and $^{154}Eu$. In this paper, the comparison between the calculated results and previous measured results was carried out to estimate the inventory of the bioshield concrete of the KRR-2. The combined computer codes of MCNP5 and ORIGEN 2.1 for calculation of the distribution of neutron flux, cross-section and generation of radionuclides were used. The results were shown that 99.8% of the total radioactivity of $^3H$, $^{55}Fe$, $^{60}Co$ and $^{152}Eu$ in the bioshield concrete 12 years after shutdown. The effects on the variation of inventory were analysed depending on the operation periods and the cooling times in the bioshield concrete.

A Study on Safety Blasting Design with Blast Vibration Analysis Urban Area (도심지 미진동 제어 발파에서 진동분석을 통한 안전발파설계에 관한 연구)

  • 안명석;박종남;배상근
    • Explosives and Blasting
    • /
    • v.17 no.2
    • /
    • pp.36-44
    • /
    • 1999
  • A study was made on the design of the prediction model concerning blasting vibration in a constraction site, Namgu, Daegu City. The geology in this area consists of hornfels of shale and mud underlain by quartize, of which the main strike of the geological structure is NW direction. Measurements were carried out on the top of the wall concrete water storage tank, which is burried in the ground earth. The attenuation due to the vertical wall of the concrete structure may be experted because of spherical divergency at the bottom corner of the wall by the Huygens principle. For design of blasting prediction model, thus among scaled distance(SD) may be preferable to use in the regression model, since they represents most likely the average ground condition. Judging from the regression results, the cube root method may be more suitable for this area. The SD values for the maximum allowable vibration velocity of 0.5 cm/s, in this area are 22.5, 28.0 and 30.6 for the significance level of 50%, 95% and 99%, respectively.

  • PDF

Spatial Distributions of $^3H$ and $^{14}C$ in the Shielding Concrete of KRR-2 (연구로 2호기 수조 콘크리트의 $^3H$$^{14}C$ 공간분포)

  • Hong, Sang-Bum;Kim, Hee-Reyoung;Chung, Kun-Ho;Kang, Mun-Ja;Jeong, Gyeong-Hwan;Chung, Un-Soo;Park, Jin-Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.4
    • /
    • pp.329-334
    • /
    • 2006
  • The depth distributions of total $^3H$ and $^{14}C$ activities were characterized for the activated shielding concrete from a decommissioning of KRR-2 using the commercially available tube furnace and a liquid scintillation counter. The correlation of measurement results between $^3H,\;^{14}C$ and gammer emitter was evaluated to apply for estimating radionuclide inventory of the concrete waste generated from decommissioning KRR-2. The detection limits for $^3H$ and $^{14}C$ are 0.048 and 0.028 Bq/g respectively. The specific activities of the $^3H$ and $^{14}C$ tend to decrease exponentially as the depth of the concrete becomes deeper from the surface. In addition, the $^3H$ and $^{14}C$ activities were in good correlation with the $^{60}CO$ activities analysed for the shielding concrete of KRR-2.

  • PDF

Evaluation of Crack Monitoring Field Application of Self-healing Concrete Water Tank Using Image Processing Techniques (이미지 처리 기법을 이용한 자기치유 콘크리트 수조의 균열 모니터링 현장적용 평가)

  • Sang-Hyuk, Oh;Dae-Joong, Moon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.4
    • /
    • pp.593-599
    • /
    • 2022
  • In this study, a crack monitoring system capable of detecting cracks based on image processing techniques was developed to effectively check cracks, which are the main damage of concrete structures, and a program capable of imaging and analyzing cracks was developed using machine vision. This system provides objective and quantitative data by replacing the appearance inspection that checks cracks with the naked eye. The verification of the development system was applied to the construction site of a self-healing concrete water tank to monitor the crack and the amount of change in the crack width according to age. In the case of crack width detected by image analysis, the difference from the measured value using a digital microscope was up to 0.036 mm, and the crack healing effect of self-healing concrete could be confirmed through the reduction of crack width.