• Title/Summary/Keyword: 수의 영상진단

Search Result 1,908, Processing Time 0.036 seconds

A Patterns of Care Study of the Various Radiation Therapies for Prostate Cancer among Korean Radiation Oncologists in 2006 (Patterns of Care Study를 위한 2006년 한국 방사선종양학과 전문의들의 전립선암 방사선치료원칙 조사연구)

  • Kim, Jin-Hee;Kim, Jae-Sung;Ha, Sung-Whan;Shin, Seong-Soo;Park, Won;Cho, Jae-Ho;Suh, Chang-Ok;Oh, Young-Taek;Shin, Sei-Won;Kim, Jae-Chul;Jang, Ji-Young;Nam, Taek-Keun;Choi, Young-Min;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.96-103
    • /
    • 2008
  • Purpose: To conduct a nationwide academic hospital patterns of the practice status and principles of radiotherapy for prostate cancer. The survey will help develop the framework of a database of Korean in Patterns of Case Study. Materials and Methods: A questionnaire about radiation treatment status and principles was sent to radiation oncologists in charge of prostate cancer treatment at thirteen academic hospitals in Korea. The data was analyzed to find treatment principles among the radiation oncologists when treating prostate cancer. Results: The number of patients with prostate cancer and treated with radiation ranged from 60 to 150 per academic hospital in Seoul City and 10 to 15 outside of Seoul City in 2006. The primary diagnostic methods of prostate cancer included the ultrasound guided biopsy on 6 to 12 prostate sites(mean=9), followed by magnetic resonance imaging and a whole body bone scan. Internal and external immobilizations were used in 61.5% and 76.9%, respectively, with diverse radiation targets. Whole pelvis radiation therapy(dose ranging from 45.0 to 50.4 Gy) was performed in 76.9%, followed by the irradiation of seminal vesicles($54.0{\sim}73.8$ Gy) in 92.3%. The definitive radiotherapy doses were increased as a function of risk group, but the range of radiation doses was wide(60.0 to 78.5 Gy). Intensity modulated radiation therapy using doses greater than 70 Gy, were performed in 53.8% of academic hospitals. In addition, the simultaneous intra-factional boost(SIB) technique was used in three hospitals; however, the target volume and radiation dose were diverse. Radiation therapy to biochemical recurrence after a radical prostatectomy was performed in 84.6%; however, the radiation dose was variable and the radiation field ranged from whole pelvis to prostate bed. Conclusion: The results of this study suggest that a nationwide Korean Patterns of Care Study is necessary for the recommendation of radiation therapy guidelines of prostate cancer.

The Study on the Correlation of the Ejection Fraction of Multi Gated Blood Pool Scan and Echocardiography According to the Condition of Cardiac Function (심장기능상태의 분류에 따른 게이트심장혈액풀 검사와 심장초음파의 심박출계수 상관관계에 관한 고찰)

  • Lee, Dong Hun;Park, Jang Won;Nam, Ki Pyo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.57-61
    • /
    • 2015
  • Purpose We considered the correlation of Ejection Fraction (EF) which was analyzed by Multi Gated Blood Pool Scan (MUGA) and Echocardiography (ECHO) for the patients who were classified according to the condition of cardiac function. Materials and Methods We analyzed the patients (female 60) who were diagnosed with breast cancer and were examined by both MUGA and ECHO. The 30 patients (age: $58.27{\pm}13.48$) who were analyzed into less than 50% to 70% of EF were categorized as normal group and the other 30 patients (age: $53.70{\pm}8.45$) who were analyzed into less than 50% of EF were categorized as abnormal group. Statistical analysis with SPSS ver. 18 was applied. Results Each of the value of mean and standard deviation of normal group was $66.43{\pm}5.80$ (MUGA), $60.50{\pm}4.93$ (ECHO). There was a significant difference (p<0.001). Each of the value of mean and standard deviation of abnormal group was $41.93{\pm}7.58$ (MUGA), $41.70{\pm}11.49$ (ECHO). There was no significant difference (p>0.001). In the result, all 30 cases of normal group showed the same reading. 8 out of 30 cases in abnormal group showed inconsistency of the reading. Conclusion We could confirm the correlation of the EF in MUGA and ECHO statistically. There was difference between abnormal groups from the result of reading. If we are aware of the result according to the different cardiac function categorization, MUGA and ECHO can be used as even more accurate interchangeable test.

  • PDF

Correlation of the Deformation of the Kyphotic Angle with the Fat Infiltration Rate of Multifidus and Erector Spinae in Patients with Acute Osteoporotic Fractures of the Lumbar Spine (급성 골다공증성 요추 골절 환자에서 척추 기립근 및 다열근의 지방침투율과 후만각 변형의 연관 관계)

  • Jun, Deuk Soo;Baik, Jong-Min;Baek, Seung Hyun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.208-214
    • /
    • 2021
  • Purpose: Verifying a reliable predictor of the progression of vertebral deformity in patients with acute osteoporotic fractures of the lumbar spine may be useful. A qualitative analysis of the muscle near the spine was performed using magnetic resonance imaging (MRI), and its correlation with a spinal deformity was determined under the hypothesis that the causes of the kyphotic deformity are associated with muscle reduction in the multifidus and erector spinae. Materials and Methods: The study was performed in a retrospective manner using the electronic medical records of patients who presented to the author's institution between January 2007 and March 2018, and were diagnosed with an acute lumbar fracture. The fat infiltration rates of the multifidus and erector spinae were measured using MRI taken at the time of injury, and the mean value was defined as the total fat infiltration rate (TFI). Based on lateral radiographs of the lumbar spine at the one-year follow-up, the loss of height of the vertebral body, the kyphotic angle and the wedge angle were measured. The statistical significance was confirmed by calculating the Pearson correlation coefficient. Results: One hundred twenty-nine patients, of which 30 were male and 99 were female, were examined. The mean age was 71.28 years. The mean T-score was -3.53±0.79 g/cm2, and the mean fat infiltration was 15.20%±11.99%. TFI was positively correlated with age (R=0.373, p<0.001), compression rate (R=0.369, p<0.001), and Cobb's angle (R=0.386, p<0.001) after a one year follow-up, but negatively correlated with the BMD score (R=-0.252, p=0.004). As the fracture progressed to the lower lumbar level, the compression rate (R=-0191, p=0.030) and wedge angle (R=-0.428, p<0.001) at the time of injury tended to decrease. Conclusion: In patients with osteoporotic vertebral fractures, the fat infiltration rate may be an important predictor of conservative treatment. The prognosis of patients with a high-fat infiltration rate should be explained during patient education, and the patients must be monitored closely through short-term outpatient follow-up.

Relationship between Alcohol Use Disorders Identification Test Fractional Anisotropy Value of Diffusion Tensor Image in Brain White Matter Region (알코올 선별 검사법(Alcohol Use Disorders Identification Test)과 뇌 백질 영역의 확산텐서 비등방도 계측 값의 관련성)

  • Lee, Chi Hyung;Kim, Gyeong Rip;Kwak, Jong Hyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.575-583
    • /
    • 2022
  • Magnetic resonance diffusion tensor imaging (DTI) has revealed the disruption of brain white matter microstructure in normal aging and alcoholism undetectable with conventional structural MR imaging. we plan to analyze the FA measurements of the ROI of dangerous drinkers selected from Alcohol Use Disorders Identification Test (AUDIT) and Tract-Based Spatial Statics (TBSS) tool was used to extract FA values in the ROI from the image acquired through the pre-processing process. TBSS has a higher sensitivity of the FA value and MD value in the white matter than the brain gray matter, and has the advantage of quantitatively deriving the unlimited degree of brain nerve fibers, and more specialized in the brain white matter. We plan to analyze the fractional anisotropy (FA) measurement value for damage by selecting the center of the anatomical structure of the white matter region of the brain with high anisotropy among the brain neural networks that are particularly vulnerable to alcohol as the region of interest (ROI). In this study, we expected that alcohol causes damage to the brain white matter microstructure from FA value in various areas including both Choroid plexus. Especially, In the case of the moderate drunker, the mean value of FA in Lt, Rt. Choroid plexus was 0.2831 and 0.2872, whereas, in the case of the severe drunker, the mean value of FA was 0.1972 and 0.1936. We found that the higher the score on the AUDIT scale, the lower the FA value in ROI region of the brain white matter. Using the AUDIT scale, the guideline for the FA value of DTI can be presented, and it is possible to select a significant number of potentially severe drinkers. In other words, AUDIT was proved as useful tool in screening and discrimination of severe drunker through DTI.

Evaluation of the Usefulness of Digital Tomosynthesis in the Chest (흉부영역에서 디지털 토모신테시스의 유용성 평가)

  • Jang, Dong-Hyuk;Shim, Sung-Shine;Choi, Jae-Wook;Choi, Jun-Gu
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.10
    • /
    • pp.340-348
    • /
    • 2012
  • To evaluate the usefulness of tomosynthesis in the chest area, simple radiograph, low-dose CT, and tomosynthesis examinations were performed, and their absorbed doses were compared, and finally the images were evaluated. The absorbed dose recorded with the simple Radiograph examination was $0.33{\pm}0.27$ mGy, that of low-dose CT $1.26{\pm}0.56$ mGy, and that of tomosynthesis $0.55{\pm}0.02$ mGy, which indicate significance differences in absorbed doses among the examinations(p<0.001). Based on the evaluations of the images, The simple radiograph scores were $1.66{\pm}0.72$, $1.61{\pm}0.63$, and $1.57{\pm}0.73$, respectively; low-dose CT scores were $2.92{\pm}0.26$, $2.91{\pm}0.29$, and $2.88{\pm}0.32$, respectively; and tomosynthesis scores were $2.69{\pm}0.51$, $2.76{\pm}0.43$, and $2.66{\pm}0.61$, respectively. That is, there were statistically significant differences among the examinations(p<0.001), although there was no significant difference between low-dose CT and tomosynthesis examinations. Therefore, tomosynthesis is judged to be a useful examination that can minimize radiation doses to patients during chest examinations and enhance diagnostic efficacy.

Analysis for Correlation of Standardized Uptake Value in Fusion Imaging Scanner (융합영상장비의 표준섭취계수 상관관계 분석)

  • Kim, Jin-Eui;Kim, Jung-Soo;Choi, Nam-Gil;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.593-601
    • /
    • 2018
  • Recently in nuclear medicine, to improve diagnostic value, SUV, semi-quantitative indicator used in PET-CT, is adopted in SPECT-CT. Therefore, this research analyzed correlation of $SUV_{max}$ of two scanners through phantom test, and evaluated possibility of clinical application. Radiopharmaceuticals ($^{18}F$, $^{99m}Tc$) were injected with the ratios of 8:1 and 4:1, considering background radioactivity, into the phantom manufactured with 6 globes of different sizes, and, based on clinical protocol, positive phases were acquired with PET-CT and SPECT-CT scanners, and interesting areas were divided into ROI and VOI, and $SUV_{max}$ of them were measured, and analyzed. Tests found out no statistically significant difference in $SUV_{max}$ measured with two scanners (P>0.05). Thus, $SUV_{max}$ of PET-CT and SPECT-CT had a certain correlation within significant levels, and were evaluated as the same. Accordingly, it seems that $SUV_{max}$ quantitative analysis using SPECT-CT can provide significant diagnostic information as the case of PET-CT.

The Comparison of Motion Correction Methods in Myocardial Perfusion SPECT (심근관류 SPECT에서 움직임 보정 방법들의 비교)

  • Park, Jang-Won;Nam, Ki-Pyo;Lee, Hoon-Dong;Kim, Sung-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.28-32
    • /
    • 2014
  • Purpose Patient motion during myocardial perfusion SPECT can produce images that show visual artifacts and perfusion defects. This artifacts and defects remain a significant source of unsatisfactory myocardial perfusion SPECT. Motion correction has been developed as a way to correct and detect the patient motion for reducing artifacts and defects, and each motion correction uses different algorithm. We corrected simulated motion patterns with several motion correction methods and compared those images. Materials and Methods Phantom study was performed. The anthropomorphic torso phantom was made with equal counts from patient's body and simulated defect was added in myocardium phantom for to observe the change in defect. Vertical motion was intentionally generated by moving phantom downward in a returning pattern and in a non-returning pattern throughout the acquisition. In addition, Lateral motion was generated by moving phantom upward in a returning pattern and in a non-returning pattern. The simulated motion patterns were detected and corrected similarly to no-motion pattern image and QPS score, after Motion Detection and Correction Method (MDC), stasis, Hopkins method were applied. Results In phantom study, Changes of perfusion defect were shown in the anterior wall by the simulated phantom motions, and inferior wall's defect was found in some situations. The changes derived from motion were corrected by motion correction methods, but Hopkins and Stasis method showed visual artifact, and this visual artifact did not affect to perfusion score. Conclusion It was confirmed that motion correction method is possible to reduce the motion artifact and artifactual perfusion defect, through the apply on the phantom tests. Motion Detection and Correction Method (MDC) performed better than other method with polar map image and perfusion score result.

  • PDF

Steroid Responsive Tremor Syndrome in a Maltese Dog (말티즈 견에서 발생한 스테로이드 반응성 진전 증후군)

  • Kang, Byeong-Teck;Jung, Dong-In;Park, Chul;Kim, Ju-Won;Kim, Ha-Jung;Lim, Chae-Young;Ko, Ki-Jin;Cho, Sue-Kyung;Lee, So-Young;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.23 no.3
    • /
    • pp.337-339
    • /
    • 2006
  • A 4-year-old, spayed female Maltese dog was presented for evaluation of acute onset of generalized tremor, right-sided head tilt, horizontal nystagmus, and mild ataxia with 4-day duration. However, the dog was bright, alert, and responsive. The neurological examinations revealed that bilateral horizontal-, positional nystagmus, and mild ataxia. Menace responses were also absent in both eyes. Typically, moderate generalized intension tremors were noted in four limbs and the head. No abnormalities were found in hemogram, radiography, and magnetic resonance imaging(MRI). Cytologic examination of cerebrospinal fluid(CSF) revealed a mild nonsuppurative inflammation. Thus, steroid responsive tremor syndrome(SRTS) was strongly suspected because of its inflammatory and idiopathic features. The dog excellently responded to immunosuppressive doses of corticosteroid. Therefore, we definitively diagnosed the dog as SRTS based on the exclusion of other causes of the tremor, clinical signs, and response to treatment. This is a first case report of SRTS in our country and we here describe clinical and neurological features in SRTS.

Surgical Repair of Coxofemoral Joint Luxation in a Wild Black-Crowned Night Heron (Nycticorax nycticorax) (야생 검은댕기해오라기에서 대퇴관절 탈골의 수술적 교정)

  • Kim, Eun-Ju;Lee, Jong-Hyun;Kim, Min-Su;Lee, Ki-Chang;Kim, Nam-Soo;Shin, Gee-Wook;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.30 no.1
    • /
    • pp.49-52
    • /
    • 2013
  • A wild black-crowned night heron (Nycticorax nycticorax) with dehydration and a non-weight bearing lameness of the left leg was rescued. On physical examination, the left knee was displaced laterally at almost a $90^{\circ}$ angle with firm swelling and crepitus in the area of the coxofemoral joint. Radiographs confirmed cranio-dorsal coxofemoral luxation. A closed reduction attempt failed. The coxofemoral joint luxation was reduced surgically by placement of the femoral neck next to the pelvis with a suture. Ten days after surgery, radiographs and computed tomography showed the femoral neck and head were positioned well within the acetabulum. At 20 days, the bird was using the affected limb normally, and could hunt and forage for food in a rehabilitation housing unit with a small pond. The bird was successfully released into the wild. The placement of the femoral neck adjacent to the pelvis with a suture can be successfully performed for cases of avian coxofemoral joint luxation. Furthermore, this procedure can provide sufficient stabilization of the coxofemoral joint and acceptable limb function.

Blood Flow Measurement with Phase Contrast MRI According to Flip Angle in the Ascending Aorta (위상대조도 MRI에서 숙임각에 따른 상행대동맥의 혈류 측정)

  • Kim, Moon Sun;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.4
    • /
    • pp.142-148
    • /
    • 2016
  • To evaluate the effect of flip angle on flow rate measurements obtained with phase contrast MRI according to the flip angle degree in ascending aorta and velocity encoding (VENC) was (150 m/s). 1.5T MRI in patients 17 (female: 8, male: 9, mean age $57.9{\pm}15.4$) as a target by applying a non-breath holding techniques to flip angle VENC (150 cm/s) in each of the ascending aorta was measured by changing $20^{\circ}$, $30^{\circ}$ and $40^{\circ}$. Blood was obtained a peak velocity, average velocity, net forward volume, net forward volume/body surface area. Ascending aorta from average velocity (AV) measured the average value of the flip angle $20^{\circ}$ (9.87 cm/s), $30^{\circ}$ (9.6 cm/s) and $40^{\circ}$ (10.05 cm/s). Blood flow VENC in was blood flow change in flip angle change was high most blood flow measurement when the flip angle $30^{\circ}$ in VENC, crouching each blood flow is also proportional to the increases in the $20^{\circ}$ to $40^{\circ}$ and was increased, the deviation of the peak velocity and the average velocity is the smallest deviation from the flip angle $30^{\circ}$. Flip angle $20^{\circ}$, $30^{\circ}$ and $40^{\circ}$ in peak velocity, average velocity, net forward volume, net forward volume/body surface area was no statistically significant difference (p > .05). Blood flow velocity and blood flow is measured by applying to adjust the flip angle accurately calculate the blood flow is important information for diagnosis and treatment of cardiovascular diseases, and can help in the examination on the blood flow measurement.