• Title/Summary/Keyword: 수의 영상진단

Search Result 1,906, Processing Time 0.038 seconds

Bow Hunter's Syndrome Caused by Bilateral Dynamic Occlusion of the Subaxial Vertebral Arteries during Neck Extension (경추 신전 시 축하 척추동맥의 양측성 동적 폐쇄로 인해 발생한 보우 헌터 증후군)

  • Yi, Jemin;Han, Ho Sung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.85-89
    • /
    • 2020
  • Bow hunter's syndrome is a rare disease that shows the symptoms of vertebrobasilar insufficiency resulting from a dynamic obstruction or stenosis of the vertebral arteries during neck movement. This paper reports a case of a 59-year-old male who visited the emergency room with diplopia, tinnitus, and gait disturbance. Magnetic resonance imaging and angiography revealed a multiple cerebellar infarct, total obstruction of the right vertebral artery, and dynamic obstruction of the left vertebral artery during neck extension. As the infarction worsened, a thrombectomy was done. Posterior decompression and fusion at C5-6 were performed for the left vertebral artery. The left vertebral arterial patency was confirmed by intraoperative and postoperative angiography. No recurrence of the symptoms was observed for six months after surgery. Physicians need to pay attention to the diagnosis of vertebrobasilar insufficiency caused by an obstruction of the vertebral arteries during neck extension in cervical instability patients.

Revision after Instability Surgery (수술 후 재발한 견관절 불안정증의 치료)

  • Kim, Paul Shinil;Jo, Chris Hyunchul
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.5
    • /
    • pp.374-382
    • /
    • 2020
  • Recurrence is the most common complication after shoulder instability surgery, and the main causes of the postoperative recurrence of instability are trauma, misdiagnosis, and technical errors. The risk factors of recurrence may be classified as patient related, anatomical or technical. Causes of failure should be thoroughly evaluated by meticulous history taking, physical examination, and imaging studies, and followed by proper treatment of pathologic lesions. Nonoperative treatment should be considered initially in cases of recurred instability after shoulder instability surgery, but if this fails, repeated recurrence is prevented by performing appropriate anatomical reconstruction of ruptured Bankart lesions, capsular laxities, glenoid deficiencies and humeral head bone defects.

A Case of Septic Arthritis due to Streptococcus intermedius in a Healthy Child (특이 과거력이 없는 소아에서 발생한 Streptococcus intermedius 화농 관절염 1예)

  • Soo Min Yong;Tae Hun Kim;Hyun Joo Jung
    • Pediatric Infection and Vaccine
    • /
    • v.29 no.3
    • /
    • pp.173-178
    • /
    • 2022
  • Streptococcus intermedius is a small, non-motile, Gram-positive, non-sporeforming, and aerotolerant anaerobic coccus. It is a part of the normal microflora in the oral cavity and upper respiratory, gastrointestinal and female urogenital tracts. It is an opportunistic pathogen that causes serious infections in patients with immunocompromised states or cardiac diseases as a result of trauma or invasive procedures. We describe a case of septic arthritis of the hip caused by S. intermedius in an immunocompetent healthy 7-year-old boy without a history of periodontal disease or invasive procedures. He had hip joint pain three weeks ago, and the fever began on the day of the visit. He had been healthy and had not undergone any invasive procedures recently. Septic arthritis of the hip was indicated in the magnetic resonance imaging of the hip. S. intermedius was identified in the hip joint fluid aspiration and blood culture. He was successfully treated with surgical intervention and antibiotic therapy with ceftriaxone followed by amoxicillin for five weeks.

A Study on the Setting of Examination Limits for Radiographers in Medical Institutions (의료기관 내 방사선사의 검사 한도 설정에 관한 연구)

  • Jeong-Ho Kim;Gap-Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.401-410
    • /
    • 2023
  • A radiographer is a job in charge of diagnostic imaging equipment, and must contribute to the promotion of public health by suggesting an appropriate level of work. To this end, we intend to present an appropriate level of work through evaluation of human harm according to work, statistical evaluation through questionnaires, and domestic and international trends. In the case of human harm evaluation, considering radiation exposure, 42.6%, shield work, 69.7%, and in the case of magnetic resonance imaging, the maximum length of stay in the examination room should be adjusted to 15 minutes and not exceed 30 times. According to the survey statistics, it was confirmed that the physical and mental burden increased due to the high workload and difficulty compared to working hours. Based on domestic and international trends, it is necessary to adjust the examination standards for domestic radiographers to 36.8% to promote national health through qualitative improvement of radiological examinations. something to do.

A Case of Advanced Gastric Cancer with Deep Vein Thrombosis Treated with Low Molecular Weighted Heparin (전이성 위암환자의 심부정맥혈전증에 대한 저분자량 헤파린 투여 사례)

  • Su Jin Heo;Chan Hyuk Park;Sang Kil Lee
    • Journal of Digestive Cancer Research
    • /
    • v.1 no.2
    • /
    • pp.108-110
    • /
    • 2013
  • The relationship between malignancy and venous thromboembolism(VTE) has been well established. About 20% of all VTE cases are associated with cancer and thrombotic events are the second leading cause of death in cancer patients after death from cancer itself. Effective prophylaxis and treatment will reduce morbidity and may decrease overall mortality. We report a case of VTE in a patient with advanced gastric cancer who treated with low-molecular weighted heparin (LMWH). A 49-year-old man with heartburn was admitted to our hospital. On the endoscopic and radiologic imaging, the patient was diagnosed as an advanced gastric cancer with perigastric infiltration and liver metastasis. During the combination chemotherapy, he had pain and swelling of left lower leg. Doppler ultrasonography showed left posterior tibial venous thrombosis and pulmonary embolism CT showed thromboembolism in subsegmental pulmonary artery branch in right lower lobe. He was treated with LMWH, Dalteparin once daily via subcutaneous injection, and his symptoms was subsided.

  • PDF

Clinical Practice Guidelines for Hepatocellular Carcinoma: Current and Future Perspectives (간암 진료가이드라인의 현재와 전망)

  • Bo Hyun Kim;Joong-Won Park
    • Journal of Digestive Cancer Research
    • /
    • v.4 no.1
    • /
    • pp.21-28
    • /
    • 2016
  • Hepatocellular carcinoma (HCC) is rather unique. Most of HCC patients have underlying chronic liver diseases with or without cirrhosis and the prognosis of HCC depends on the liver function, as well as the tumor extent. Non-invasive diagnosis of HCC can be made with certain risk factors and specific imaging findings (e.g. hypervascularity). Patients with HCC can receive surgical resection, radiotherapy, and systemic chemotherapy as other solid malignancies. HCC has more treatment options such as liver transplantation, transarterial chemoembolization (TACE) and radiofrequency ablation (RFA). A variety of practice guidelines for HCC has been published by many academic societies. Different healthcare systems and availability of resources also affect the practice guidelines; therefore, practice guidelines have similarities and dissimilarities. Herein, we review the current status of practice guidelines for HCC and future perspectives for the improvement of guidelines are also discussed.

  • PDF

Evaluation of Classification Models of Mild Left Ventricular Diastolic Dysfunction by Tei Index (Tei Index를 이용한 경도의 좌심실 이완 기능 장애 분류 모델 평가)

  • Su-Min Kim;Soo-Young Ye
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.761-766
    • /
    • 2023
  • In this paper, TI was measured to classify the presence or absence of mild left ventricular diastolic dysfunction. Of the total 306 data, 206 were used as training data and 100 were used as test data, and the machine learning models used for classification used SVM and KNN. As a result, it was confirmed that SVM showed relatively higher accuracy than KNN and was more useful in diagnosing the presence of left ventricular diastolic dysfunction. In future research, it is expected that classification performance can be further improved by adding various indicators that evaluate not only TI but also cardiac function and securing more data. Furthermore, it is expected to be used as basic data to predict and classify other diseases and solve the problem of insufficient medical manpower compared to the increasing number of tests.

Comparison of Image Uniformity Due to Position Shifting in COR on Myocardial SPECT (Myocardial SPECT시 COR에서 위치변화에 따른 Image Uniformity 비교)

  • Lim, Hyun-Jin;Kim, Joong-Hyun;Kim, Jae-Il;Lim, Jung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.70-75
    • /
    • 2012
  • Purpose: It is important to acquire accurate data because the SPECT scan affected by various physical factors. The aim of this study was to compare the uniformity when both centers were matched or mismatched differed from position of heart in COR. Materials and methods: The images were acquired with cylindrical uniform phantom (6.7 cm diameter, 9 cm length) and heart insert phantom using Cardio MD SPECT system (Philips, USA). The phantoms were positioned on COR as well as four different points which were 10 cm above, below, left and right side from the COR. The counts from the both edge of cylindrical uniform phantom and those from the both wall of heart insert phantom were compared by using vertical and horizontal line profile. In addition, the qualitative evaluation was performed with heart insert phantom images and volunteer test. Results: In heart insert phantom study, the differences of counts between COR and 10 cm above, below, left and right point of COR were 1.1, 4.1, 4.9, 2.2 and 0.9% using T-A curve for horizontal view. In case of vertical view of COR 3.9, 21.9, 3.5, 23.9, 14.0% were shown. In cylindrical phantom study, the differences of counts between COR and 10 cm above, below, left and right point of COR were 4.3, 0.3, 3.3, 2.6 and 0.7% using T-A curve for horizontal view. In case of vertical view of COR 2.7, 3.0, 1.0, 0.3, 3.4% were shown. For qualitative evaluation, the images at COR were the most uniform for both of heart insert phantom and volunteer test, whereas other four positions showed somewhat distorted images. Conclusion: It showed the most uniform images when COR is matched with the heart. Therefore, we can expect that distortion which increased or decreased of myocardial perfusion will be prevented by matching the heart and COR when positioning. Furthermore, the accuracy of diagnosis will be improved as well.

  • PDF

Quantitative Study of Annular Single-Crystal Brain SPECT (원형단일결정을 이용한 SPECT의 정량화 연구)

  • 김희중;김한명;소수길;봉정균;이종두
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.163-173
    • /
    • 1998
  • Nuclear medicine emission computed tomography(ECT) can be very useful to diagnose early stage of neuronal diseases and to measure theraputic results objectively, if we can quantitate energy metabolism, blood flow, biochemical processes, or dopamine receptor and transporter using ECT. However, physical factors including attenuation, scatter, partial volume effect, noise, and reconstruction algorithm make it very difficult to quantitate independent of type of SPECT. In this study, we quantitated the effects of attenuation and scatter using brain SPECT and three-dimensional brain phantom with and without applying their correction methods. Dual energy window method was applied for scatter correction. The photopeak energy window and scatter energy window were set to 140ke${\pm}$10% and 119ke${\pm}$6% and 100% of scatter window data were subtracted from the photopeak window prior to reconstruction. The projection data were reconstructed using Butterworth filter with cutoff frequency of 0.95cycles/cm and order of 10. Attenuation correction was done by Chang's method with attenuation coefficients of 0.12/cm and 0.15/cm for the reconstruction data without scatter correction and with scatter correction, respectively. For quantitation, regions of interest (ROIs) were drawn on the three slices selected at the level of the basal ganglia. Without scatter correction, the ratios of ROI average values between basal ganglia and background with attenuation correction and without attenuation correction were 2.2 and 2.1, respectively. However, the ratios between basal ganglia and background were very similar for with and without attenuation correction. With scatter correction, the ratios of ROI average values between basal ganglia and background with attenuation correction and without attenuation correction were 2.69 and 2.64, respectively. These results indicate that the attenuation correction is necessary for the quantitation. When true ratios between basal ganglia and background were 6.58, 4.68, 1.86, the measured ratios with scatter and attenuation correction were 76%, 80%, 82% of their true ratios, respectively. The approximate 20% underestimation could be partially due to the effect of partial volume and reconstruction algorithm which we have not investigated in this study, and partially due to imperfect scatter and attenuation correction methods that we have applied in consideration of clinical applications.

  • PDF

Comparison of Horizontal and Vertical Noise Power Spectrum in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료 시 전자포털 영상장치를 이용한 잡음전력스펙트럼 수평 및 수직 측정비교)

  • Kim, Ki-Won;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Kwon, Kyung-Tae;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.171-176
    • /
    • 2016
  • The quality assurance (QA) is very important for diagnostic field and radiation therapy field to evaluate the characteristic of devices. The purpose of this study was to compare different NPS methodologies results which are measuring NPS with regard to horizontal and vertical directions by using megavoltage X-ray energies. The NPS evaluation methods were applied to the International Electro-technical Commission standard (IEC 62220-1). The electronic portal imaging devices (EPID) devices such as Siemens BEAMVIEW$^{PLUS}$, Elekta iViewGT and Varian Clinac$^R$ iX aS1000 were used. NPS data were expressed by corresponding each frequency about average of noise value corresponding the each frequency, and NPS were evaluated quantitatively by totaling up the noise values of average frequency which are on horizontal and vertical directions. In NPS results for Elekta iViewGT, NPS of horizontal and vertical by using 4 methods were indicated the difference of 3~5% between horizontal and vertical direction. In the results of Siemens BEAMVIEW$^{PLUS}$ and Varian Clinac$^R$ iX aS1000, the NPS of horizontal and vertical direction were indicated the difference of 15% when averaging the whole values. This study were evaluated the NPS of each devices by totaling up the noise values of average frequency which are on horizontal and vertical directions suggesting the quantitative evaluation method using the data.