• Title/Summary/Keyword: 수위 공진

Search Result 14, Processing Time 0.021 seconds

Effects of the Oscillating Water Channel Length on the Water Surface Elevation within Seawater Exchange Breakwater (진동수로 내장 해수교환방파제의 수로길이 변화에 따른 수위공진)

  • 이달수;오영민;전인식;김창일
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.303-306
    • /
    • 2003
  • 해수교환방파제 설치로 항내의 수질개선 효과를 기대하려면 방파제를 통해 항내로 순유입량이 발생되어야 한다. 순유입량이 발생되기 위해서는 방파제 전면의 최대수위 또는 평균수위가 증대되거나 방파제의 도수로 내에서 항외측으로 발생하는 흐름을 감소시켜야 한다. (중략)

  • PDF

A Diode Bridge-type ZVT Inverter for Induction Motor Drive Applications (유도 전동기 구동용 다이오드 브릿지-타입 ZVT 인버터)

  • 이성룡;고성훈;송인석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.561-569
    • /
    • 1999
  • In this paper, the diode bridge-type ZVT(Zero- Voltage Transition) inverter is proposed. It consists of one a auxiliaI${\gamma}$ switch, three resonant inductors and six blockin당 diodes. So, the main advantage of the proposed t torXJ!ogy is the reduction of the auxiliar${\gamma}$ switch compare to the conventional ZVT inverter. The topology of t the propostxl lVT inverter is analyztxl with a description of the control conditions based on the load current. A And the resonant period control for operating the proposed inverter optimally is discussed by using resonant i inductor current ftxxlback. To verify the proposed topology, the detailed simulation and exJX끼mental results i indicate that zero volta당e operation during transition can be achieved.

  • PDF

Numerical Simulation on Control of Tsunami by Resonator (II) (for Samcheok port) (공진장치에 의한 지진해일파의 제어에 관한 수치시뮬레이션(II) (삼척항에 대해))

  • Lee, Kwang-Ho;Jeon, Jong-Hyeok;Kim, Do-Sam;Lee, Yun-Du
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.6
    • /
    • pp.496-505
    • /
    • 2020
  • In the previous research, the effectiveness of resonator was confirmed through the numerical analysis on two cases with the use of existing resonator at the Mukho and Imwon ports located in the eastern coast of South Korea by discussing the reduction rates of 1983 Central East Sea tsunami, and 1993 Hokkaido Southwest off tsunami, respectively. In this study, the reduction rates of tsunami height with three different resonators, Type I, II-1, and II-2, at the Samcheok port were examined respectively through the numerical analysis using COMCOT model under the same condition as the previous study. It was discussed the spatial distribution of maximum height of tsunami, change of water level, and effectiveness of resonator with the presence of new types of resonator, and change of their sizes. As a result, the effectiveness of resonator was verified through the application of new types of resonator reducing about maximum 40% of tsunami height. In order to design the optimal resonator for the variety of site condition, it is necessary to research about the various cases applying different shape, arrangement, and size of resonator as further study.

A research on Dynamic characteristic of Submerged pipe ; Support, Flange, Upper pump (수위변화에 따른 파이프 시스템의 진동 특성 변화에 대한 연구)

  • Jung, Hwee Kwon;Kim, Jong Yoon;Park, Gyuhae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.699-705
    • /
    • 2013
  • This paper presents vibration testing, control, and finite element analysis of a piping system, which is subjected to the changes in fluid levels. Nuclear power plants typically employ a cooling system that uses sea water. These systems are subjected to dynamic characteristic changes caused by sea-level variations, which introduces failures of cooling system components. Therefore in this study, analytical and experimental studies were performed to understand the effect of sea-level changes on the dynamic characteristics of piping systems. It was shown that, as the sea-level increases, pipe's natural frequencies decreases in relation to its mode shape. A 1/14 scale model was also built to compare the results obtained by the analytical study. A good agreement between experiment and analytical studies were observed. Finally, an on-line resonant frequency identification system was proposed and developed, which utilizes piezoelectric transducers as sensors and actuators, in order to avoid catastrophic failure of piping systems.

  • PDF

Derivation of Correct Solutions for Harbor Oscillations by Depth Discontinuity along Offshore Boundary (외해 경계에서의 수심 불연속에 의한 항만 공진의 정해 유도)

  • 정원무;박우선;서경덕
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.13 no.3
    • /
    • pp.254-261
    • /
    • 2001
  • It is well known that when long waves propagate from deep ocean onto a continental shelf with a very steep continental slope, the waves reflected from the shore can not propagate offshore and are re-reflected from the continental slope so that large water level fluctuations are induced near the shore. Liu(1986) has analyzed this phenomenon by assuming a topography which has a depth discontinuity along a semicircular offshore boundary, but his solution is erroneous. In the present paper, we correct his analytical solutions for a straight shoreline and a rectangular harbor. The corrected solution is then compared with the numerical results of the Galerkin finite element model of Jeong et al.(1998), which is based on the extended mild-slope equation.

  • PDF

Effects of the Oscillating Water Channel Length on the Water Surface Elevation within Seawater Exchange Breakwater (진동수로 내장 해수교환방파제의 수로길이 변화에 따른 수위공진)

  • Lee, Dal-Soo;Oh, Young-Min;Chun, In-Sik;Kim, Chang-Il
    • Ocean and Polar Research
    • /
    • v.25 no.spc3
    • /
    • pp.423-426
    • /
    • 2003
  • The seawater exchange breakwater equipped with an oscillating water channel and water transmitting pipes has a very spectacular function that seawater supply can be greatly increased due to the upsurge of the water surface inside the channel at resonance condition which can be reached when the incident wave period becomes close to the natural period of the channel. The variations of the water level and period inside the channel are very important factors in enhancing the efficiency of sea water exchange, especially when designing the breakwater cross-section in shallow water zone which requires longer resonance period with the elongated horizontal projection of the channel. In the present study, a hydraulic experiment was performed varying the length of the oscillating channel, and the resonance periods and water surface variations are analyzed in terms of water transmission through the pipes.

Analysis of Abnormal Wave at the West Coast on 31 March 2007 (2007년 3월 31일 서해안에 발생한 이상파랑에 대한 원인 분석)

  • Eom, Hyun-Min;Seung, Young-Ho;Woo, Seung-Buhm;You, Sung-Hyup
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.3
    • /
    • pp.217-227
    • /
    • 2012
  • On 31 March 2007, the abnormal wave occurred along western coast of Korean including Yeonggwang. In this paper, this event is studied using available field measurement data for the event analysis and numerical model for reproducing the unknown waves. We found several 1-min interval tidal elevation and mean sea level pressure (MSLP) data along the western coast of Korea and analyzed it using wavelet technique. We computed the arrival time and the propagation direction of abnormal wave using wavelet results and performed the numerical simulation using 2 dimensional shallow water wave model. The sea level under the forcing of air pressure jump was obviously amplified by the Proudman resonant effect. The computed sea levels compared with observations are underestimated, but the order of arrival time at the tidal station showed good agreement.

Numerical Simulation of Irregular Airflow within Wave Power Converter Using OWC by Action of 3-Dimensional Irregular Waves (3차원불규칙파동장하의 진동수주형 파력발전구조물에서 불규칙공기흐름의 수치시뮬레이션)

  • Lee, Kwang-Ho;Park, Jung-Hyun;Kim, Do-Sam
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.3
    • /
    • pp.189-202
    • /
    • 2012
  • An Oscillating Water Column (OWC) wave generation system uses the air flow induced by the vertical motion of water column in the air chamber as a driving force of turbine. It is well known that OWC is one of the most efficient devices to harness wave power. This study estimated the air flow velocity from the time variation of the water level fluctuation in the air chamber under regular wave conditions using 3-dimensional numerical irregular wave tank (3D-NIT) model that can simulate the 3-dimensional irregular wave field. The applicability of the 3D-NIT model was validated by comparing numerically predicted air flow velocities with hydraulic experimental results. In addition, the characteristics of air flow frequency spectrum variation due to the incident frequency spectrum change, and the variations of frequency spectrum and wave reflection due to the existence of converter inside the air chamber were discussed. It is found that the phase difference exists in between the air flow velocity and the water level fluctuation inside the air chamber, and the peak frequency of the spectrum in water level fluctuation is amplified by the resonance in the air chamber.

An Integrated Single-Stage Zero Current Switched Quasi-Resonant Power Factor Correnction Converter with Active Clamp Circuit (능동 클램프 회로를 적용한 단상 ZCS 공진형 역률개선 컨버터)

  • 문건우;구관본;윤명중
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.6
    • /
    • pp.539-546
    • /
    • 1999
  • A new integrated single-stage zero current switched(ZCS) quasi resonant convertedQRC) for the IX)wer f factor correction(PFCl converter is introduced in this paper. The power factor correction can be achieved by t the discontinuous conduction mod$\varepsilon$(DCM) operation of an input current. The proposed converter has the c characteristics of the good IX)wer factor, 10씨 line current harmonics, and tight output regulation. Furthern10re, t the ringing effect due to the output capacitance of the main switch can be eliminated by use of‘ active clamp c circuit. Therefore, the proIX)sed converter is expecttc'(] to be suitable for a compact power converter with a t tightly regulated output voltage requiring a switching frequency of more than several hundrtc'(]s kHz.

  • PDF