Abstract
In the previous research, the effectiveness of resonator was confirmed through the numerical analysis on two cases with the use of existing resonator at the Mukho and Imwon ports located in the eastern coast of South Korea by discussing the reduction rates of 1983 Central East Sea tsunami, and 1993 Hokkaido Southwest off tsunami, respectively. In this study, the reduction rates of tsunami height with three different resonators, Type I, II-1, and II-2, at the Samcheok port were examined respectively through the numerical analysis using COMCOT model under the same condition as the previous study. It was discussed the spatial distribution of maximum height of tsunami, change of water level, and effectiveness of resonator with the presence of new types of resonator, and change of their sizes. As a result, the effectiveness of resonator was verified through the application of new types of resonator reducing about maximum 40% of tsunami height. In order to design the optimal resonator for the variety of site condition, it is necessary to research about the various cases applying different shape, arrangement, and size of resonator as further study.
전편의 연구에서는 기존공진장치를 동해안의 묵호항과 임원항에 적용하여 1983년에 발생한 동해중부지진해일과 1993년에 발생한 북해도남서외해지진해일의 작용 하에 각 항내에서 지진해일고의 저감율을 수치적으로 검토하여 실해역의 지진해일파에 대한 기존공진장치의 유용성을 확인하였다. 후편의 본 연구에서는 전편과 동일한 지지해일파의 작용조건 하에 세 개의 신형공진장치 I, II-1 및 II-2를 동해안의 삼척항에 적용하여 지진해일고의 저감율을 각각 검토하였으며, 또한 수치해석에는 전편과 일관성을 갖도록 COMCOT 모델을 적용하였다. 삼척항에서 각 신형공진장치의 부착여부, 각 신형공진장치의 크기변화에 따른 최대지진해일고의 공간분포와 수위의 시간변동 및 공진장치의 유용성 등을 함께 논의하였다. 이로부터 신형공진장치를 부착함으로서 지진해일고를 최대 40% 정도로 저감시켰으며, 따라서 신형공진장치의 유용성을 확인할 수 있었다. 현장조건에 적합한 최적의 공진장치를 얻기 위해서는 지진해일파의 입사 방향 등을 고려하여 공진장치의 형상, 배치 및 크기에 관해 다각도적인 검토가 수행될 필요가 있는 것으로 판단된다.