Study on Hydrogen Embrittlement for API 5L X65 Steel Using Small Punch Test II : Weld Metal (소형펀치 시험을 이용한 API 5L X65 강의 수소취화에 관한 연구 II : 용접부)

  • Jang, Sang-Yup;Yoon, Kee-Bong
    • Journal of Energy Engineering
    • /
    • v.18 no.1
    • /
    • pp.56-62
    • /
    • 2009
  • With weld metal of X65 steel, hydrogen was charged by electro-chemical method and mechanical behavior such as strength was measured by the small punch test. The weld metal was more sensitive to hydrogen charging than the case of base metal. The small punch (SP) strength was decreased as the hydrogen contents increased. Magnitude of strength decrease was dependent on current density, temperature, charging time. Current density and charging time have significant effect on the mechanical properties but temperature of electrolyte has limited effect. Fractured surfaces of the tested specimens were observed by SEM (scanning electron microscope). In the hydrogen charged specimens cleavage fracture were observed, which is consistent with the SP test results. Since the testing procedure for studying hydrogen embrittlement proposed in this study has shown good reproducibility of test results, the proposed method can be assumed to be a reliable test procedure. Using the electrochemical charging and the small punch test, the change of SP strength for X65 weld metal due to hydrogen embritlement could be evaluated sensitively.

Characteristics of the Transverse Fuel Injection into a Supersonic Crossflow using Various Injector Geometries (분사구 형상에 따른 초음속 유동장 내 수직 연료 분사 특성)

  • Kim, Seihwan;Lee, Bok Jik;Jeung, In-Seuck;Lee, Hyoungjin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.3
    • /
    • pp.53-64
    • /
    • 2018
  • In this study, computational simulation was performed to investigate the characteristics of air/fuel mixing according to the shape of the injector exit when the transverse jet was injected into a supersonic flow. Non-reacting flow simulation was conducted with fixed mass flow rate and the same cross-sectional area. To validate the results, free stream Mach number and jet-to-crossflow memetum ratio are set to 3.38 and 1.4, respectively, which is same as the experimental condition. Further, separation region, structure of the under-expended jet, jet penetration height, and flammable region of hydrogen for five different injectors compared.

Development on Antibiotic Concrete Mixed with Antibacterial Metals and Metallic Salts (금속 및 금속염계 항균제가 혼입된 항균 콘크리트 개발)

  • Choi, Hong-Shik;Heo, Kwon;Lee, Ho-Beom;Lee, Si-Woo;Kwak, Hong-Shin
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.2
    • /
    • pp.136-143
    • /
    • 2013
  • In the sewage structures and wastewater facilities, concrete is exposed to hydrogen sulfide ($H_2S$) which acts as an acid material in a solution, and a strongly acidic sulfate ion ($SO{_4}^{-2}$) is generated by a sulfuric bacteria. Hence, a degradation of concrete with biochemical corrosion would be accelerated. Finally, durability of concrete and concrete structures may be greatly reduced. In this study, in order to remove the hydrogen sulfide which is used by the sulfuric bacteria organic-biologically, the antibiotic metal and metallic salt powders were mixed to concrete, and a suppressing performance of the sulfate ion was assessed. For the sulfuric acid bacteria, a comparative evaluation of antimicrobial performance on neutralized concrete specimens were carried out, also by a rapid chloride penetration test, chloride penetration depths and diffusion coefficients were measured for antibiotic concrete in accordance with the amount of metal and metallic salt-based antibacterial agents. Eventually, by an observation of the biochemical state of the surface of concrete specimens exposed outdoors, the performance and applicability of antibiotic concrete were confirmed.

Environmental Isotope - Aided studies on Sea Water contamination of Eastern Coastal Aquifer in Cheju Island (환경동위원소(環境同位元素)를 이용(利用)한 제주동부지역(濟州東部地域) 대수층(帶水層)의 해수오염(海水汚染)에 관(關)한 연구(硏究))

  • Ahn, Jong-Sung;Kim, Sun-Joon;U, Zang-Kual;Song, Sung-Jun
    • Korean Journal of Environmental Agriculture
    • /
    • v.11 no.1
    • /
    • pp.26-40
    • /
    • 1992
  • Cheju Island formed by Quarternary volcanism provides highly permeable hydrogeological environment. To meet the increasing demand of water in the island, many groundwater wells have been developed. The environmental isotopes(oxygen-18, deuterium, tritium) and chemical analysis of water samples from the eastern part of the island were carried out to ascertain whether groundwater in the eastern part of the island was contaminated by sea water. The result of tritium analysis indicated fast infiltration of meteoric water into underground and rapid mixing process between rain water and groundwater. The results of oxygen-18 and deuterium analysis demonstrated that most of the wells in the eastern part of the island were influenced by sea water intrusion. Chemical analysis of water samples revealed that most groundwater in study area were classified into Na-Cl type and showed high chloride/bicarbonate ratios. Sea water intrusion in the northeastern part of the island has proceeded at least 3 km within the coastaline, and in the south eastern part about 700m.

  • PDF

Numerical Study of Heat Flux and BOG in C-Type Liquefied Hydrogen Tank under Sloshing Excitation at the Saturated State (포화상태에 놓인 C-Type 액체수소 탱크의 슬로싱이 열 유속과 BOG에 미치는 변화의 수치적 분석)

  • Lee, Jin-Ho;Hwang, Se-Yun;Lee, Sung-Je;Lee, Jang Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.5
    • /
    • pp.299-308
    • /
    • 2022
  • This study was conducted to predict the tendency for heat exchange and boil-off gas (BOG) in a liquefied hydrogen tank under sloshing excitation. First, athe fluid domain excited by sloshing was modeled using a multiphase-thermal flow domain in which liquid hydrogen and hydrogen gas are in the saturated state. Both the the volume of fluid (VOF) and Eulerian-based multi-phase flow methods were applied to validate the accuracy of the pressure prediction. Second, it was indirectly shown that the fluid velocity prediction could be accurate by comparing the free surface and impact pressure from the computational fluid dynamics with those from the experimental results. Thereafter, the heat ingress from the external convective heat flux was reflected on the outer surfaces of the hydrogen tank. Eulerian-based multiphase-heat flow analysis was performed for a two-dimensional Type-C cylindrical hydrogen tank under rotational sloshing motion, and an inflation technique was applied to transform the fluid domain into a computational grid model. The heat exchange and heat flux in the hydrogen liquid-gas mixture were calculated throughout the analysis,, whereas the mass transfer and vaporization models were excluded to account for the pure heat exchange between the liquid and gas in the saturated state. In addition, forced convective heat transfer by sloshing on the inner wall of the tank was not reflected so that the heat exchange in the multiphase flow of liquid and gas could only be considered. Finally, the effect of sloshing on the amount of heat exchange between liquid and gas hydrogen was discussed. Considering the heat ingress into liquid hydrogen according to the presence/absence of a sloshing excitation, the amount of heat flux and BOG were discussed for each filling ratio.

The Acid Rock Drainage and Hydraulic Characteristics of the Waste Rock Dump (폐석적치장의 산성배수발생 및 수리특성 분석)

  • Cheong, Young Wook;Ji, Sang Woo;Yim, Gil Jae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.4
    • /
    • pp.13-24
    • /
    • 2004
  • This study was carried out to plan the prevention of the generation and discharge of Acid Rock Drainage (ARD). The Acid Base Accounting(ABA) test was performed for geological materials such as pit wall, waste rock and stream sediments near the Imgi abandoned pyrophyllite mine in Busan, Korea. In addition, hydraulic characteristics were tested with the disk tension infiltrometer around the waste rock dump. Maximum Potential Acidity(MPA) of geological materials near the Imgi mine was 246.942kg $H_2SO_4/t$, and maximum Acid Neutralising Capacity(ANC) was 8.7kg $H_2SO_4/t$. These results indicate the pit wall and waste rock, except most of stream sediments are acid generating geological materials. These have salt and free hydrogen ion which resulted from oxidation of sulfides. Hence they could be convert rain water to acid rock drainage. Although the waste rock dump of the Imgi mine have very low infiltration rate, slopes of the waste rock dump have many "V" type erosion gullies and multi-layers. These gullies and multi-layers have coarse clastic particle layers which have very large hydraulic conductivity. Through this coarse clastic particle layer a large part of rain flow into ground. And also this layer could function as aeration path which induced oxidation of sulfide minerals and generation of ARD continuously.

  • PDF

Geophysical and Geochemical Studies for the Saline Water Intrusion under the Paddy Field in Kyoung-gi area, Korea (경기 지역 농경지 하부로의 해수 침투에 관한 지구물리 및 지구화학적 연구)

  • Lee Sang-Ho;Kim Kyoung-Woong;Lee Sang-Kyu
    • Geophysics and Geophysical Exploration
    • /
    • v.2 no.2
    • /
    • pp.96-103
    • /
    • 1999
  • Most of saline water inousions have been diagnosed by geophysical or geochemical approach independently. The objective of this study is to provide the effective method to detect the saline water intrusion on the ground water in the vicinity of seashore using these two methods. Schulumberger sounding, frequency domain electromagnetic sounding and geochemical analysis of ground water were carried out to explore saline water intrusion. Schulumberger sounding was implemented in dry surface condition before irrigation water was introduced into the field, while electromagnetic sounding was carried out in wet ground condition after the irrigation. The purpose of duplicated measurements on the equivalent spot at different times was to investigate the variation of anomaly zone depending on the amount of ground water. It was possible to discriminate the anomalous zone due to high water saturation from the low electric resistivity zone by high salt concentrations through this way. For the verification of the geophysical result, the ground water samples in the study area were collected and analysed at the 23 points near the measuring spots. The groundwater at the spot nearest to the sea water intrusion identified by geophysical method indicates higher salinity than the standard limit concentration for agricultural irrigation water (250 mg/1). Isotope analysis of $D({^2}H)$ vs. is ${^18}O$ and PCA analysis were used to discriminate the anthropogenic pollution from those of high salinity from sea water intrusion.

  • PDF

Characteristics of Groundwater Contamination Caused by Seawater Intrusion and Agricultural Activity in Sacheon and Hadong Areas, Republic of Korea (해수침투와 농업활동에 의한 사천-하동 해안지역 지하수의 오염 특성)

  • Kim, Hyun-Ji;Hamm, Se-Yeong;Kim, Nam-Hoon;Cheong, Jae-Yeol;Lee, Jeong-Hwan;Jang, Sung
    • Economic and Environmental Geology
    • /
    • v.42 no.6
    • /
    • pp.575-589
    • /
    • 2009
  • Groundwater has been extracted for irrigation in Sacheon-Hadong area, which is close to the South Sea. We analyzed chemical components of groundwater to examine the effects of seawater intrusion and agricultural activities in the study area. Most groundwater samples displayed the Na/Cl concentration ratios similar to that of seawater (0.55) with an increasing tendency of electrical conductivity ($227-7,910\;{\mu}S/cm$) towards the coast. In addition, statistical interpretation of the cumulative frequency curves of Cl and $HCO_3$ showed that 30.1% of the groundwater samples were highly affected by seawater intrusion. Groundwaters in the study area mostly belonged to the Ca-Cl and Na-Cl type, demonstrating that they were highly influenced by seawater intrusion and cation exchange. The result of oxygen-hydrogen isotope analysis demonstrated slightly higher $\delta^{18}O$ ((-8.53)-(-6.13)‰) and ${\delta}D$ ((-58.7)-(-43.7)‰) comparing to mean oxygen-hydrogen isotope ratios in Korea. As a result of nitrogen isotope analysis, the $\delta^{15}N-NO_3$ values ((-0.5)-(19.1)‰) indicate two major sources of nitrate pollution (organic nitrogen in soil and animal and human wastes) and mixed source of the two. However, denitrification may partly contribute as a source of nitrogen. According to factor analysis, four factors were identified among which factor 1 with an eigenvalue of 6.21 reflected the influence of seawater intrusion. Cluster analysis indicated the classification of groundwater into fresh, saline, and mixed ones.

Fossil Saline Groundwater and Their Flushing Out At Gilsan Stream Catchment in the Western Coastal Area of Seocheon, Korea (서천 해안지역 길산천 소유역에서의 고염분 지하수와 씻김 현상)

  • Sang-Ho Moon;Yoon Yeol Yoon;Jin-Yong Lee
    • Economic and Environmental Geology
    • /
    • v.55 no.6
    • /
    • pp.671-687
    • /
    • 2022
  • It has been reported that about 47% of groundwater wells within 10 km from the coastline in the western/southern coastal areas of Korea were affected by seawater. It has been interpreted that the cause of groundwater salinization is seawater intrusion. The Gilsan stream in the Seocheon area was a tidal stream until the Geumgang estuary dam was constructed and operated. Therefore, it is likely that the Gilsan stream catchment was deposited with sediments containing high-saline formation water prior to the use of landfill farmland at this catchment area. The groundwater in this study area showed EC values ranging from 111 to 21,000 µS/cm, and the water quality types were diverse including Ca(or Na)-HCO3, Ca(or Na)-HCO3(Cl), Na-Cl(HCO3), Na-Cl types. It is believed that this diversity of water quality is due to the mixing of seawater and fresh groundwater generated by infiltration of precipitation and surface water through soil and weathered part. In this study, we discussed whether this water quality diversity and the presence of saline groundwater are due to present seawater intrusion or to remnant high-saline pore water in sediments during flushing out process. For this, rain water, surface water, seawater, and groundwater were compared regarding the water quality characteristics, tritium content, oxygen/hydrogen stable isotopic composition, and 87Sr/86Sr ratio. The oxygen/hydrogen stable isotopic compositions indicated that water composition of saline groundwaters with large EC values are composed of a mixture of those of fresh groundwater and surface water. Also, the young groundwater estimated by tritium content has generally higher NO3 content. All these characteristics showed that fresh groundwater and surface water have continued to affect the high-saline groundwater quality in the study area. In addition, considering the deviation pattern in the diagrams of Na/Cl ratio versus Cl content and SAR (sodium adsorption ratio) versus Cl content, in which two end members of fresh surface-ground water and seawater are assumed, it is interpreted that the groundwater in the study area is not experiencing present seawater intrusion, but flush out and retreating from ancient saline formation water.

Low Temperature Optical Properties of NiO coated ZnO Nanorods (NiO 코팅 두께에 따른 ZnO 나노막대의 저온분광특성)

  • Shin, Y.H.;Park, Y.H.;Kim, Yong-Min
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.4
    • /
    • pp.286-290
    • /
    • 2007
  • We fabricated NiO coated ZnO nanorods using ZnO nanorods grown on a Si substrate. After thermal hydrogenation process of these NiO-ZnO core-shell nanorods, we confirm that Ni nanodots were built up on the surface of ZnO nanorods. Photoluminescence (PL) measurements at T=5 K were made to understand the optical properties of these various nanorods. As samples sequencially transformed into $ZnO{\rightarrow}NiO-ZnO{\rightarrow}Ni$ nanodot-ZnO, PL transition energies and intensities are varied as well. In comparison to pure ZnO nanorod, the acceptor bound exciton ($A^0X$) became the minor peak for NiO-ZnO nanorods. On the other hand, for Ni nanodot-ZnO sample, ($A^0X$) transition peak intensity became the most dominant peak. This is due to the fact that during thermal hydrogenation process, appreciable amounts of Ni and hydrogen ions defused into ZnO nanorod which played as accepters.